... connect at the appropriate speed • Internally bridged 10 and 100 Mbps network segments to run at 10 or 100 Mbps, making network configuration and upgrade effortless. Start Here The NETGEAR Model DS508, Model DS516, and Model DS524 Dual Speed Stackable Hubs are network hubs that enable users to 240 V AC power supply • Dual cooling...
... connect at the appropriate speed • Internally bridged 10 and 100 Mbps network segments to run at 10 or 100 Mbps, making network configuration and upgrade effortless. Start Here The NETGEAR Model DS508, Model DS516, and Model DS524 Dual Speed Stackable Hubs are network hubs that enable users to 240 V AC power supply • Dual cooling...
DS508 Installation Guide
Page 4
... in a mixed 10/100 Mbps environment. Typical Applications The Model DS508, Model DS516, and Model DS524 hubs can be used for easy migration from 10 Mbps to shared network resources such as servers, printers, and routers. Users connected at 10 Mbps can coexist with power users...=Receive 5 100 10 17 On=Link, Blinking=Receive 100 10 MODEL DS524 On=Link, Blinking=Receive 12 Normal/Uplink 24 Model DS524 hub Model DS508 hubs Model DS516 hub Model RT328 ISDN Router 100 Mbps 10 Mbps Servers PCs Power user 8673FA Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide
... in a mixed 10/100 Mbps environment. Typical Applications The Model DS508, Model DS516, and Model DS524 hubs can be used for easy migration from 10 Mbps to shared network resources such as servers, printers, and routers. Users connected at 10 Mbps can coexist with power users...=Receive 5 100 10 17 On=Link, Blinking=Receive 100 10 MODEL DS524 On=Link, Blinking=Receive 12 Normal/Uplink 24 Model DS524 hub Model DS508 hubs Model DS516 hub Model RT328 ISDN Router 100 Mbps 10 Mbps Servers PCs Power user 8673FA Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide
DS508 Installation Guide
Page 5
... MODEL DS516 On=Link, Blinking=Receive 8 Normal/Uplink 16 Front Panel of the Model DS524 Hub 100 Mbps Collision LED 100 Mbps Utilization LEDs vista RJ-45 network ports Auto 10/100 MbpsDUAL SPEED 16PORT 10/100Mbps Dual Speed Stackable Hub Collision Utilization% 100 Mbps Power Data 1 10 20 >40 10 Mbps 1 100 10 13...
... MODEL DS516 On=Link, Blinking=Receive 8 Normal/Uplink 16 Front Panel of the Model DS524 Hub 100 Mbps Collision LED 100 Mbps Utilization LEDs vista RJ-45 network ports Auto 10/100 MbpsDUAL SPEED 16PORT 10/100Mbps Dual Speed Stackable Hub Collision Utilization% 100 Mbps Power Data 1 10 20 >40 10 Mbps 1 100 10 13...
DS508 Installation Guide
Page 6
... (only two pairs are positioned at the top corners of each Off vista RJ-45 network port) Blinking Power is occurring on the port. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide There is established successfully between the hub and the PC. The RJ-45 connector uses an 8-pin interface. Two LEDs are...
... (only two pairs are positioned at the top corners of each Off vista RJ-45 network port) Blinking Power is occurring on the port. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide There is established successfully between the hub and the PC. The RJ-45 connector uses an 8-pin interface. Two LEDs are...
DS508 Installation Guide
Page 7
...inches (20.3 cm). Adequate power source within 6 feet (1.83 m). vista RJ-45 network ports 100M 10M 8152FA Rear Panel of the Model DS508, Model DS516, and Model DS524 Hubs Cascade Up connector Terminator LED 10/100 Mbps Bridge LED Power receptacle Cascade Up Cascade ...DS524 hub has two LEDs, one labeled Terminator and one labeled 10/100 Mbps Bridge. Front and back clearance for an external terminator). The Terminator LED indicates whether or not the built-in terminator in that hub is active (the built-in room or wiring closet. Model DS508/DS516/DS524 Dual Speed Stackable Hub...
...inches (20.3 cm). Adequate power source within 6 feet (1.83 m). vista RJ-45 network ports 100M 10M 8152FA Rear Panel of the Model DS508, Model DS516, and Model DS524 Hubs Cascade Up connector Terminator LED 10/100 Mbps Bridge LED Power receptacle Cascade Up Cascade ...DS524 hub has two LEDs, one labeled Terminator and one labeled 10/100 Mbps Bridge. Front and back clearance for an external terminator). The Terminator LED indicates whether or not the built-in terminator in that hub is active (the built-in room or wiring closet. Model DS508/DS516/DS524 Dual Speed Stackable Hub...
DS508 Installation Guide
Page 10
... DS508, Model DS516, and Model DS524 hubs use a shared circuit. If power is disconnected from one hub in a single repeater (or collision) domain. Build a Larger Network Cascade up to Eight Hubs to Build a Larger Network As many as they would in the stack, the hub above it takes over the bridge ...Hz 0.5A Bridge LED On Terminator LED On 8099FA The cascade connectors on . Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide The stack of eight hubs can connect through the network to any combination of 192 ports in the stack. Any device connected to one of the 192...
... DS508, Model DS516, and Model DS524 hubs use a shared circuit. If power is disconnected from one hub in a single repeater (or collision) domain. Build a Larger Network Cascade up to Eight Hubs to Build a Larger Network As many as they would in the stack, the hub above it takes over the bridge ...Hz 0.5A Bridge LED On Terminator LED On 8099FA The cascade connectors on . Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide The stack of eight hubs can connect through the network to any combination of 192 ports in the stack. Any device connected to one of the 192...
DS508 Installation Guide
Page 11
... each connected port is on. • Utilization LEDs on the front panel are on the Model DS524 hub. Connect a PC to PCs. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Select Uplink if connecting a hub or switch. The Bridge LED in the rear panel are any port in the... With a single hub, the Terminator and Bridge LEDs in the bottom hub is on . • With a stack of the hub allows you to the Troubleshooting table. The Normal/Uplink push button eliminates the need to the port. NETGEAR highly recommends using Category 5 cable so your network can operate at ...
... each connected port is on. • Utilization LEDs on the front panel are on the Model DS524 hub. Connect a PC to PCs. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Select Uplink if connecting a hub or switch. The Bridge LED in the rear panel are any port in the... With a single hub, the Terminator and Bridge LEDs in the bottom hub is on . • With a stack of the hub allows you to the Troubleshooting table. The Normal/Uplink push button eliminates the need to the port. NETGEAR highly recommends using Category 5 cable so your network can operate at ...
DS508 Installation Guide
Page 13
... 100 Mbps capable. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Check installation of a Cascade cable not Check for proper connection. Make sure cables and connectors are normal on and the remaining hubs in the wrong position Check the Normal/Uplink push button on the network adapter card and PC or workstation. Excessive...
... 100 Mbps capable. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Check installation of a Cascade cable not Check for proper connection. Make sure cables and connectors are normal on and the remaining hubs in the wrong position Check the Normal/Uplink push button on the network adapter card and PC or workstation. Excessive...
DS508 Installation Guide
Page 14
... Dimensions Width: Height: Depth: Weight AC Power Input Voltage Standards Compliance Status LEDs Unit: 10 Mbps network segment: 100 Mbps network segment: Per UTP port: Rear panel: Environmental Specifications Operating temperature: Operating humidity: Electromagnetic Emissions Safety Agency Approvals Model DS508 8 Ports Model DS516 16 ... (CISPR 22), Class A VCCI Class 1 CE mark, commercial UL listed (UL 1950) CSA certified (CSA 22.2 #950) TUV licensed (EN 60 950) Model DS524 24 Ports 5.1 lb (2.3 kg) Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide
... Dimensions Width: Height: Depth: Weight AC Power Input Voltage Standards Compliance Status LEDs Unit: 10 Mbps network segment: 100 Mbps network segment: Per UTP port: Rear panel: Environmental Specifications Operating temperature: Operating humidity: Electromagnetic Emissions Safety Agency Approvals Model DS508 8 Ports Model DS516 16 ... (CISPR 22), Class A VCCI Class 1 CE mark, commercial UL listed (UL 1950) CSA certified (CSA 22.2 #950) TUV licensed (EN 60 950) Model DS524 24 Ports 5.1 lb (2.3 kg) Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide