...liftmaster.com MAINTENANCE & OPERATION 1 INSTALLATION TABLE OF CONTENTS Features and Specifications Role of Specifiers and Designers Role of Dealers, Installers and Trained System Technicians UL Gate Classifications Role of End Users Overhead Gate / Door Systems Safety Installation Instructions Steps 1-2 Installation of Operator Steps 3-5 Mounting the Operator...Reversing Sensor Step 10 Adjustable Timer Step 11 Terminal Input Connections Steps 12-13 IMPORTANT INFORMATION Operating Instructions for Optional Systems Three Push Button System House Alarm / Proximity Switch Connections Optional ...
...liftmaster.com MAINTENANCE & OPERATION 1 INSTALLATION TABLE OF CONTENTS Features and Specifications Role of Specifiers and Designers Role of Dealers, Installers and Trained System Technicians UL Gate Classifications Role of End Users Overhead Gate / Door Systems Safety Installation Instructions Steps 1-2 Installation of Operator Steps 3-5 Mounting the Operator...Reversing Sensor Step 10 Adjustable Timer Step 11 Terminal Input Connections Steps 12-13 IMPORTANT INFORMATION Operating Instructions for Optional Systems Three Push Button System House Alarm / Proximity Switch Connections Optional ...
HCT501130 Manual
Page 4
...ASSEMBLY - In case of gate to prevent injury to children. FEATURES AND SPECIFICATIONS 8.25" 4" 141" VARIABLE OPERATING LENGTHS Door Height 8 ft. NOISE ISOLATOR - ENTRAPMENT ALARM SYSTEM - Door Operator Length 141 in. 165 in. 189 in. 22.01" 8.36" 18.875" CONTINUOUS CYCLE 240 LBS. ...single board. All electronic parts are gold-zinc plated and/or powder coated for a long, quiet life. MANUAL RELEASE - PULL COMMERCIAL DOOR AND GATE OPERATOR 1/2 HP - 120 VAC 1PH - 60HZ - 4.8 AMPS WEIGHT 123 LBS MOTOR - 120VAC 4.8 Amp 1/2 HP instant reversing parking gate Leeson Motor ...
...ASSEMBLY - In case of gate to prevent injury to children. FEATURES AND SPECIFICATIONS 8.25" 4" 141" VARIABLE OPERATING LENGTHS Door Height 8 ft. NOISE ISOLATOR - ENTRAPMENT ALARM SYSTEM - Door Operator Length 141 in. 165 in. 189 in. 22.01" 8.36" 18.875" CONTINUOUS CYCLE 240 LBS. ...single board. All electronic parts are gold-zinc plated and/or powder coated for a long, quiet life. MANUAL RELEASE - PULL COMMERCIAL DOOR AND GATE OPERATOR 1/2 HP - 120 VAC 1PH - 60HZ - 4.8 AMPS WEIGHT 123 LBS MOTOR - 120VAC 4.8 Amp 1/2 HP instant reversing parking gate Leeson Motor ...
HCT501130 Manual
Page 5
...features of the installation steps for each job, should: • Read and fully understand the manual. • Confirm that the operator being installed is appropriate for the application. • Confirm that the gate/door is designed and built according to current published industry... setting that this testing is performed routinely. • Offer the owner/end user a maintenance contract, or contact them regularly to operate the manual disconnect feature. • Leave safety instructions, product literature, installation manual and maintenance manual with DASMA's Automatic Gate Opener ...
...features of the installation steps for each job, should: • Read and fully understand the manual. • Confirm that the operator being installed is appropriate for the application. • Confirm that the gate/door is designed and built according to current published industry... setting that this testing is performed routinely. • Offer the owner/end user a maintenance contract, or contact them regularly to operate the manual disconnect feature. • Leave safety instructions, product literature, installation manual and maintenance manual with DASMA's Automatic Gate Opener ...
HCT501130 Manual
Page 6
... the general public. Class III - UL GATE CLASSIFICATIONS Class II - Class IV - Industrial/Limited access vehicular gate operator A vehicular gate operator (or system) intended for use in which unauthorized access is prevented via supervision by security personnel. 4 Commercial/General access vehicular ...gate operator A vehicular gate operator (or system) intended for use in a commercial location or building such as a factory or loading dock area or...
... the general public. Class III - UL GATE CLASSIFICATIONS Class II - Class IV - Industrial/Limited access vehicular gate operator A vehicular gate operator (or system) intended for use in which unauthorized access is prevented via supervision by security personnel. 4 Commercial/General access vehicular ...gate operator A vehicular gate operator (or system) intended for use in a commercial location or building such as a factory or loading dock area or...
HCT501130 Manual
Page 7
... that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. • Vehicular Vertical Pivot-Gate/Door Operator (or System) - Body parts may have arms that is intended for vehicular entrances or exits to move . • Prominently display and maintain...the system. • Never allow anyone to climb under, over or through a gate or the adjacent fence area. • Never allow children to operate system. • Keep portable controls out of reach of children. • Never allow anyone from playing near any other place where danger exists. ...
... that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. • Vehicular Vertical Pivot-Gate/Door Operator (or System) - Body parts may have arms that is intended for vehicular entrances or exits to move . • Prominently display and maintain...the system. • Never allow anyone to climb under, over or through a gate or the adjacent fence area. • Never allow children to operate system. • Keep portable controls out of reach of children. • Never allow anyone from playing near any other place where danger exists. ...
HCT501130 Manual
Page 8
... gate during the entire path of 4' (1.2 m) above the ground at any moving gate or barrier. 12) For a gate operator utilizing a contact sensor such as the perimeter reachable by building structures, natural landscaping or similar obstruction. Additionally, if the bottom edge...8226; Photoelectric Sensors • Screen Mesh • Vertical Posts • Instructional and Precautionary Signage 4) Install the gate operator only when: A) The operator is prevented from passing through the gate to prevent unauthorized use conditions. E) A wireless contact sensor such as the one ...
... gate during the entire path of 4' (1.2 m) above the ground at any moving gate or barrier. 12) For a gate operator utilizing a contact sensor such as the perimeter reachable by building structures, natural landscaping or similar obstruction. Additionally, if the bottom edge...8226; Photoelectric Sensors • Screen Mesh • Vertical Posts • Instructional and Precautionary Signage 4) Install the gate operator only when: A) The operator is prevented from passing through the gate to prevent unauthorized use conditions. E) A wireless contact sensor such as the one ...
HCT501130 Manual
Page 9
CL CL Gate Door STEP 2 Open the gate/door and mark the center point of the gate/door. STEP 1 With the gate/door closed, mark the center of the gate/door on the ceiling. 7 Gate/door should stay in the open position when springs are properly balanced. INSTALLATION OF OPERATOR Make sure the gate/door opens and closes smoothly.
CL CL Gate Door STEP 2 Open the gate/door and mark the center point of the gate/door. STEP 1 With the gate/door closed, mark the center of the gate/door on the ceiling. 7 Gate/door should stay in the open position when springs are properly balanced. INSTALLATION OF OPERATOR Make sure the gate/door opens and closes smoothly.
HCT501130 Manual
Page 10
CL Header Bracket CL Header Bracket CL CL STEP 4 Lift the operator and align with center mark on ceiling. Bolt or weld the end of the opening. Use only for installation.) Concrete CL Anchor 1/2" x 3 1/2" STEP 5 Bolt or weld arm to wall. MOUNTING THE OPERATOR STEP 3 Make sure the header bracket is not part of the operator. Have someone hold the operator in place or use something as a support post, and bolt to ceiling. (A support post is in the center of the track (header bracket) to gate/door. Support Post Door Arm Gate Arm 8
CL Header Bracket CL Header Bracket CL CL STEP 4 Lift the operator and align with center mark on ceiling. Bolt or weld the end of the opening. Use only for installation.) Concrete CL Anchor 1/2" x 3 1/2" STEP 5 Bolt or weld arm to wall. MOUNTING THE OPERATOR STEP 3 Make sure the header bracket is not part of the operator. Have someone hold the operator in place or use something as a support post, and bolt to ceiling. (A support post is in the center of the track (header bracket) to gate/door. Support Post Door Arm Gate Arm 8
HCT501130 Manual
Page 11
... gas, power, or other underground utility lines, contact local underground utility locating companies before digging. Minimum 12 Gauge Ground Wire connected to HCT Earth Ground Wire Black = 120 Vac Wire White = Neutral Wire Green = Earth Ground Wire Use UL Listed conduit to enclose power wires... pipes may come near lightning strike, a path from an electrical static discharge or a near a moving gate/door. installed to do the operator without consulting the wiring so may result in most cases. The ground wire must be visible and local electrical codes. HOW TO CONNECT POWER...
... gas, power, or other underground utility lines, contact local underground utility locating companies before digging. Minimum 12 Gauge Ground Wire connected to HCT Earth Ground Wire Black = 120 Vac Wire White = Neutral Wire Green = Earth Ground Wire Use UL Listed conduit to enclose power wires... pipes may come near lightning strike, a path from an electrical static discharge or a near a moving gate/door. installed to do the operator without consulting the wiring so may result in most cases. The ground wire must be visible and local electrical codes. HOW TO CONNECT POWER...
HCT501130 Manual
Page 12
... 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT POWER OVERLOAD MADE IN USA Plug Reset Switch Connector to operator BEFORE installing. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR J5 DC-BACKUP CENTER SAFETY EXIT 10 ALL electrical.... 1. Connect like wires from the gate/door jambs (Figure 1). 3. When such an event occurs the alarm will continuously sound and the operator will not have any functionality until the board is not provided. Disconnect power to the interface cable. Mount reset switch at a minimum of ...
... 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT POWER OVERLOAD MADE IN USA Plug Reset Switch Connector to operator BEFORE installing. STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR J5 DC-BACKUP CENTER SAFETY EXIT 10 ALL electrical.... 1. Connect like wires from the gate/door jambs (Figure 1). 3. When such an event occurs the alarm will continuously sound and the operator will not have any functionality until the board is not provided. Disconnect power to the interface cable. Mount reset switch at a minimum of ...
HCT501130 Manual
Page 13
Push the limit nut lock plate inward. Reapply power to the operator. 2. Push Plate 11 If further adjustment is needed, repeat the process. ADJUSTING TRAVELING DISTANCE STEP 8 Before Adjusting, Do the Following: 1. Place the plate back in the notch. 4. Disconnect power to operator. 5. Roll the nut to the direction desired. 3.
Push the limit nut lock plate inward. Reapply power to the operator. 2. Push Plate 11 If further adjustment is needed, repeat the process. ADJUSTING TRAVELING DISTANCE STEP 8 Before Adjusting, Do the Following: 1. Place the plate back in the notch. 4. Disconnect power to operator. 5. Roll the nut to the direction desired. 3.
HCT501130 Manual
Page 14
... CENTER SAFETY EXIT DO NOT TOUCH ALARM SENSOR The level of reverse sensitivity has to 60 seconds (Timer ON), For push open/push close type operation (Timer OFF).
... CENTER SAFETY EXIT DO NOT TOUCH ALARM SENSOR The level of reverse sensitivity has to 60 seconds (Timer ON), For push open/push close type operation (Timer OFF).
HCT501130 Manual
Page 15
... 2 Supply 24 Volts DC Master/Second Link: Not used in normal installation Wire 13 + Radio Power 12 Relay 11 - 24 Volt WARNING: To ENSURE proper operation of a button. Grey 3 Wire 24 Vdc Radio Receiver 4 Wire 24 Vdc Radio Receiver 3 4 External "Safety" Loop Detector Card Reader 10 9 ® ® 11 Ground (-) 13...
... 2 Supply 24 Volts DC Master/Second Link: Not used in normal installation Wire 13 + Radio Power 12 Relay 11 - 24 Volt WARNING: To ENSURE proper operation of a button. Grey 3 Wire 24 Vdc Radio Receiver 4 Wire 24 Vdc Radio Receiver 3 4 External "Safety" Loop Detector Card Reader 10 9 ® ® 11 Ground (-) 13...
HCT501130 Manual
Page 17
... Omni "Option Board" Needed to # 1 . N.C. Step 3 - Connect OPEN push button to Perform This Function OPEN STOP CLOSE WARNING: For proper operation, cut , the stop button will not function. Connect STOP push button to # 5 . QCC W4 OPEN GBAA B SMTOSPLINKCLOSE MAGLOCK ALARM ARMED M/S LINK...page 3 & 4 - Close Command 12 & 13 - Normally Open 1 Amp - 24 Vdc 14 - Note: If this jumper is designed for slide gate operators only! STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA 1 2 3 4 5 6...
... Omni "Option Board" Needed to # 1 . N.C. Step 3 - Connect OPEN push button to Perform This Function OPEN STOP CLOSE WARNING: For proper operation, cut , the stop button will not function. Connect STOP push button to # 5 . QCC W4 OPEN GBAA B SMTOSPLINKCLOSE MAGLOCK ALARM ARMED M/S LINK...page 3 & 4 - Close Command 12 & 13 - Normally Open 1 Amp - 24 Vdc 14 - Note: If this jumper is designed for slide gate operators only! STRIKE OPEN RADIO RECEIVER GATE LOCKED EXIT LOOP SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA 1 2 3 4 5 6...
HCT501130 Manual
Page 20
SECONDARY ENTRAPMENT PROTECTION Secondary Entrapment Protection (Contact Sensor) Edge Sensor Wiring When touched, the electrically activated edge sensors immediately signal the door/gate operator to test edges regularly. ®OmniControl Surge Suppressor P/N Q410 Patent Pending 123456 7 8 9 10 11 12 13 G BA M/S Link... Note: If multiple sensors are being used, all of the edge sensors are to be connected in class I or class II gate operator. 18 Property owners are going to use a contact sensor as a secondary entrapment protection, you should use a recognized component to comply ...
SECONDARY ENTRAPMENT PROTECTION Secondary Entrapment Protection (Contact Sensor) Edge Sensor Wiring When touched, the electrically activated edge sensors immediately signal the door/gate operator to test edges regularly. ®OmniControl Surge Suppressor P/N Q410 Patent Pending 123456 7 8 9 10 11 12 13 G BA M/S Link... Note: If multiple sensors are being used, all of the edge sensors are to be connected in class I or class II gate operator. 18 Property owners are going to use a contact sensor as a secondary entrapment protection, you should use a recognized component to comply ...
HCT501130 Manual
Page 21
... safety devices. 19 Patent Pending Center Loop Safety Loop Exit F Loop Ke - + Strike Open Push Button Radio Receiver ® OmniControl Surge Suppressor P/N Q410 Patent Pending (LiftMaster Commercial Protector System shown) 3 4 GBA M/S Link Center Loop Safety Loop - Exit Fire Dept Strike Open Loop Key Switch Push Button + Radio Receiver Class 2 Supply 24... the light beam while the door is OmniControl Surge S closing, the door will stop and reverse to be used in class I or class II gate operator.
... safety devices. 19 Patent Pending Center Loop Safety Loop Exit F Loop Ke - + Strike Open Push Button Radio Receiver ® OmniControl Surge Suppressor P/N Q410 Patent Pending (LiftMaster Commercial Protector System shown) 3 4 GBA M/S Link Center Loop Safety Loop - Exit Fire Dept Strike Open Loop Key Switch Push Button + Radio Receiver Class 2 Supply 24... the light beam while the door is OmniControl Surge S closing, the door will stop and reverse to be used in class I or class II gate operator.
HCT501130 Manual
Page 22
... SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA CAUTION: Use different frequencies for every single loop detector. Turn off operator power (breaker switch from main power source) before installatioAnir.(1) Off On Refer. Rm Eug. Serve 2 Air (2) Conditioner Comp. Bus 1, 2, 3 Off On Conditioner Off Off Conference... GBA MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS 1 3 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. Rm Oper. Manu. 1 Rm Main Dept. Serve 1 Off Off Gate...
... SAFETY LOOP CENTER LOOP RESET MOTOR CLOSE STOP OPEN POWER OVERLOAD MADE IN USA CAUTION: Use different frequencies for every single loop detector. Turn off operator power (breaker switch from main power source) before installatioAnir.(1) Off On Refer. Rm Eug. Serve 2 Air (2) Conditioner Comp. Bus 1, 2, 3 Off On Conditioner Off Off Conference... GBA MS LINK ALARM SENSOR DC-BACKUP SYSTEM ON SENSORS 1 3 1 3 REVERSE SENSOR TIMER 60 3 OFF OPEN LEFT 1 3 ON OPEN RIGHT COMMAND PROCESSED FIRE DEPT. Rm Oper. Manu. 1 Rm Main Dept. Serve 1 Off Off Gate...
HCT501130 Manual
Page 23
... 12 13 G BA M/S Link Center Loop Safety Loop - Caution: To PREVENT damage to vehicles shorter than 14 feet, a center loop system should be installed. Allows operator to automatically open when vehicles are connected to the same loop detector: • They should be series connected to stay open for exiting vehicles. Exit...
... 12 13 G BA M/S Link Center Loop Safety Loop - Caution: To PREVENT damage to vehicles shorter than 14 feet, a center loop system should be installed. Allows operator to automatically open when vehicles are connected to the same loop detector: • They should be series connected to stay open for exiting vehicles. Exit...
HCT501130 Manual
Page 24
...• Be sure power is properly adjusted, and there are prohibited, except for each remote control in use . NEVER permit children to operate, or play with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are no obstructions to ... to HIGH security mode, any interference received, including interference that may not cause harmful interference, and (2) this device may cause undesired operation. 22 Operation is factory set at the HIGH position for home or office use . THERE ARE NO OTHER USER SERVICEABLE PARTS. The receiver is ...
...• Be sure power is properly adjusted, and there are prohibited, except for each remote control in use . NEVER permit children to operate, or play with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are no obstructions to ... to HIGH security mode, any interference received, including interference that may not cause harmful interference, and (2) this device may cause undesired operation. 22 Operation is factory set at the HIGH position for home or office use . THERE ARE NO OTHER USER SERVICEABLE PARTS. The receiver is ...
HCT501130 Manual
Page 25
... contacts will glow steadily for 1/4 second regardless of the length of constant closure is PROHIBITED. Pry open the front panel of CONSTANT OPERATION on residential openers is prohibited on the receiver. The learn " button on the receiver panel until the indicator light turns off (about...Learn Button indicator light will close for 30 seconds. 3. Press and release the reprogram each remote control that you wish to M operate your operator. The receiver is factory set for each remote control. With the jumper in "C" (Constant) position, the contacts will be ...
... contacts will glow steadily for 1/4 second regardless of the length of constant closure is PROHIBITED. Pry open the front panel of CONSTANT OPERATION on residential openers is prohibited on the receiver. The learn " button on the receiver panel until the indicator light turns off (about...Learn Button indicator light will close for 30 seconds. 3. Press and release the reprogram each remote control that you wish to M operate your operator. The receiver is factory set for each remote control. With the jumper in "C" (Constant) position, the contacts will be ...