"Manufacturer's Certification for Credit" Manual
Page 1
... Residential DC Linear Actuator (Single Gate Model LA4121PKGDC) LiftMaster LA412 Solar Residential DC Linear Actuator (Dual Gate Model LA412-2PKGDC) LiftMaster LA400 Residential DC Linear Actuator (Single Gate Model LA4001PKGDC) LiftMaster LA400 Residential DC Linear Actuator (Dual Gate Model LA400-2PKGDC) LiftMaster LA500 Light Commercial / Residential DC Linear Actuator (Single Gate Model LA5001PKGDC) LiftMaster LA500 Light Commercial / Residential DC Linear...
... Residential DC Linear Actuator (Single Gate Model LA4121PKGDC) LiftMaster LA412 Solar Residential DC Linear Actuator (Dual Gate Model LA412-2PKGDC) LiftMaster LA400 Residential DC Linear Actuator (Single Gate Model LA4001PKGDC) LiftMaster LA400 Residential DC Linear Actuator (Dual Gate Model LA400-2PKGDC) LiftMaster LA500 Light Commercial / Residential DC Linear Actuator (Single Gate Model LA5001PKGDC) LiftMaster LA500 Light Commercial / Residential DC Linear...
DC Gate Operators Overview Brochure Manual
Page 1
... Panel) 12VDC Yes Yes Yes Yes 147 cycles Up to 24 days standby time Yes Approx. 22 cycles per day). LiftMaster® Gate Operators LA500DC Model Number Description LA5001PKGDC 24VDC Residential / Light Commercial Linear Actuator Photo of Gate Operator Security+ 2.0™ 3 Channel Receiver (50... Years 16' 1000 lbs 250 RSL12VDC 12VDC Residential/Light Commercial DC Slide Gate Operator ELITE® SERIES COMMERCIAL GATE OPERATORS CSW24VDC CSL24VDC 24VDC High Traffic Commercial Swing Gate Operator 24VDC High Traffic Commercial Slide Gate Operator Yes 114 cycles Up to 63 days standby...
... Panel) 12VDC Yes Yes Yes Yes 147 cycles Up to 24 days standby time Yes Approx. 22 cycles per day). LiftMaster® Gate Operators LA500DC Model Number Description LA5001PKGDC 24VDC Residential / Light Commercial Linear Actuator Photo of Gate Operator Security+ 2.0™ 3 Channel Receiver (50... Years 16' 1000 lbs 250 RSL12VDC 12VDC Residential/Light Commercial DC Slide Gate Operator ELITE® SERIES COMMERCIAL GATE OPERATORS CSW24VDC CSL24VDC 24VDC High Traffic Commercial Swing Gate Operator 24VDC High Traffic Commercial Slide Gate Operator Yes 114 cycles Up to 63 days standby...
DC Gate Operators Overview Brochure Manual
Page 2
...or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Expansion board is optional on LA400DC, LA412DC, RSL12VDC, RSW12VDC, and standard on LA500DC, CSL24VDC, and CSW24VDC. • Plug...2.0™ patented multi-frequency secure radio technology virtually eliminates interference and offers 2X the range of mind (when paired with the model 828LM LiftMaster Internet Gateway). • Battery Backup safeguards your smartphone for emergency access. Logs up , these best-in-class features come ...
...or 230V single phase (LA500DC, CSL24VDC, CSW24VDC). © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com LMGTCTCOMP 6/14 Expansion board is optional on LA400DC, LA412DC, RSL12VDC, RSW12VDC, and standard on LA500DC, CSL24VDC, and CSW24VDC. • Plug...2.0™ patented multi-frequency secure radio technology virtually eliminates interference and offers 2X the range of mind (when paired with the model 828LM LiftMaster Internet Gateway). • Battery Backup safeguards your smartphone for emergency access. Logs up , these best-in-class features come ...
CSL24VDC Installation Manual
Page 8
... Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps 24 Vdc Transformer Run / Battery Backup 24 Vdc, 500mA max. INTRODUCTION OPERATOR SPECIFICATIONS This model is intended for ON + SW (switched) 24 Vdc at 60 watts max. 2200 lbs. (997.9 kg) 4 feet (1.2 m) 50 feet (15.24 m) 1 foot/second Continuous Continuous...
... Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps 24 Vdc Transformer Run / Battery Backup 24 Vdc, 500mA max. INTRODUCTION OPERATOR SPECIFICATIONS This model is intended for ON + SW (switched) 24 Vdc at 60 watts max. 2200 lbs. (997.9 kg) 4 feet (1.2 m) 50 feet (15.24 m) 1 foot/second Continuous Continuous...
CSL24VDC Installation Manual
Page 18
The 33AH application requires the 33AH wire harness (Model K94-37236). Connect the white jumper from new wire harness kit + - + - 33AH Batteries 16 Connect the other end of the red (+) wire to allow more ...
The 33AH application requires the 33AH wire harness (Model K94-37236). Connect the white jumper from new wire harness kit + - + - 33AH Batteries 16 Connect the other end of the red (+) wire to allow more ...
CSL24VDC Installation Manual
Page 26
..., SOS system, etc.). Typically not required. Pre-Motion Delay Aux Relay Out - Tamper (Slide Gates Only) Cycle Quantity Feedback Fire Dept Open input Heater Accessory (Model HTR) RESIDENTIAL COMMERCIAL/GENERAL COMMERCIAL ACCESS INDUSTRIAL Normally set to OPEN so that gate closes immediately after AC power fail. Normally set to know when...
..., SOS system, etc.). Typically not required. Pre-Motion Delay Aux Relay Out - Tamper (Slide Gates Only) Cycle Quantity Feedback Fire Dept Open input Heater Accessory (Model HTR) RESIDENTIAL COMMERCIAL/GENERAL COMMERCIAL ACCESS INDUSTRIAL Normally set to OPEN so that gate closes immediately after AC power fail. Normally set to know when...
CSL24VDC Installation Manual
Page 31
...to obtain the desired OPEN or CLOSE functionality. 7 1, 2, and 3 LEDs: LEDs indicating the status of AC power, gate will remain in loop detector (Model LOOPDETLM) detects a fault, then the gate will open and remain open approximately 15 seconds after AC power fail and remain OPEN until fault is solid... set to check the firmware version of the SBC, OPN, CLS, and STP inputs. 10 Loop Detector Inputs: Inputs for the Plug-In Loop Detectors (Model LOOPDETLM) 10 5 SHADOW INTERUPT EXIT 1 23 4 29 OPEN CLOSE POWER TO MAIN BOARD 8 6 7 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE COM 9 SBC OPN...
...to obtain the desired OPEN or CLOSE functionality. 7 1, 2, and 3 LEDs: LEDs indicating the status of AC power, gate will remain in loop detector (Model LOOPDETLM) detects a fault, then the gate will open and remain open approximately 15 seconds after AC power fail and remain OPEN until fault is solid... set to check the firmware version of the SBC, OPN, CLS, and STP inputs. 10 Loop Detector Inputs: Inputs for the Plug-In Loop Detectors (Model LOOPDETLM) 10 5 SHADOW INTERUPT EXIT 1 23 4 29 OPEN CLOSE POWER TO MAIN BOARD 8 6 7 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE COM 9 SBC OPN...
CSL24VDC Installation Manual
Page 44
...is 24 Vdc at 60 watts maximum. EXAMPLE 2: A system with a solar application. We recommend LiftMaster low power draw accessories to minimize power draw, refer to see performance trade-offs. Solar Application requirements:...the system is not in class solar performance due to 3 loop detectors can remain in series (Model SOLPNL10W12V). • A maximum of two 10W solar panels in standby. NOTE: Input solar ... (up to highly efficient electronics that reach below 32˚F. SOLAR USAGE GUIDE The CSL24VDC has best in use to cold weather and a reduced number of hours of AC...
...is 24 Vdc at 60 watts maximum. EXAMPLE 2: A system with a solar application. We recommend LiftMaster low power draw accessories to minimize power draw, refer to see performance trade-offs. Solar Application requirements:...the system is not in class solar performance due to 3 loop detectors can remain in series (Model SOLPNL10W12V). • A maximum of two 10W solar panels in standby. NOTE: Input solar ... (up to highly efficient electronics that reach below 32˚F. SOLAR USAGE GUIDE The CSL24VDC has best in use to cold weather and a reduced number of hours of AC...
CSL24VDC Installation Manual
Page 47
... box. APPENDIX STEP 6 continued... SOLAR PANEL(S) INSTALL THE SOLAR PANEL 1. Connect the black wire to the Adjustment section. 33AH Batteries - +- + J15 Plug (new wire harness, Model K94-37236) Black Wire (-) + Diode Red Wire (+) + - + Black Wire (-) Red Wire (+) + - - + + - - 40W Solar panel installation - 60W Solar panel installation 45...
... box. APPENDIX STEP 6 continued... SOLAR PANEL(S) INSTALL THE SOLAR PANEL 1. Connect the black wire to the Adjustment section. 33AH Batteries - +- + J15 Plug (new wire harness, Model K94-37236) Black Wire (-) + Diode Red Wire (+) + - + Black Wire (-) Red Wire (+) + - - + + - - 40W Solar panel installation - 60W Solar panel installation 45...
CSL24VDC Installation Manual
Page 53
...and can detect a car as it approaches and will then open the gate. Model 65ME120C5 REMOTE CONTROLS LiftMaster offers a variety of LiftMaster remote controls to satisfy your authorized LiftMaster dealer for additional details and options. 3-BUTTON REMOTE CONTROL The 3-button remote ...configuration. Model STAR450-315 PLUG-IN LOOP DETECTOR Conveniently plugs into existing control board. Model 86LM WIRELESS ACCESS CONTROL RECEIVER Access control receiver for all MG020 type edges. Posts not included. Model 893MAX MISCELLANEOUS POST-MOUNTING PLATE For post-mounting model CSL24VDC commercial ...
...and can detect a car as it approaches and will then open the gate. Model 65ME120C5 REMOTE CONTROLS LiftMaster offers a variety of LiftMaster remote controls to satisfy your authorized LiftMaster dealer for additional details and options. 3-BUTTON REMOTE CONTROL The 3-button remote ...configuration. Model STAR450-315 PLUG-IN LOOP DETECTOR Conveniently plugs into existing control board. Model 86LM WIRELESS ACCESS CONTROL RECEIVER Access control receiver for all MG020 type edges. Posts not included. Model 893MAX MISCELLANEOUS POST-MOUNTING PLATE For post-mounting model CSL24VDC commercial ...
CSL24VDC Installation Manual
Page 54
...extended periods of time. Must be powered separately. Model MG1300 HEATER Keeps operator gearbox and batteries at suitable temperature when outside temperature is below 0°F (-18°C) for 33AH applications. Model HTR LIFTMASTER® INTERNET GATEWAY Internet enabled accessory which connects to... the computer and allows you to replace original batteries provided with 33AH batteries. Model A12330SGLPK BATTERY TRAY For use with Solar Applications. Not...
...extended periods of time. Must be powered separately. Model MG1300 HEATER Keeps operator gearbox and batteries at suitable temperature when outside temperature is below 0°F (-18°C) for 33AH applications. Model HTR LIFTMASTER® INTERNET GATEWAY Internet enabled accessory which connects to... the computer and allows you to replace original batteries provided with 33AH batteries. Model A12330SGLPK BATTERY TRAY For use with Solar Applications. Not...
CSL24VDC Gate Operator and Accessory Site Plan Manual
Page 1
...while closing. 6 MPEL Mounting Plate for Post Mounting For post mounting model CSL24VDC commercial slide operator. Protects system to be installed with operator. Commercial DC VEHICULAR SLIDE GATE OPERATOR Model CSL24VDC Gate Operator and Accessory Site Plan 2 1 MyQ® Enabled ...Indoor Controls 2 Remote Controls 3 Photoelectric Sensors 4 Loop Detectors 5 Edge Sensors 6 Mounting Plate and Stand 7 Solar 8 Batteries 9 Heater 10 dwellingLIVE 1 10 7 5 3 6 89 4 LiftMaster gate operators ...
...while closing. 6 MPEL Mounting Plate for Post Mounting For post mounting model CSL24VDC commercial slide operator. Protects system to be installed with operator. Commercial DC VEHICULAR SLIDE GATE OPERATOR Model CSL24VDC Gate Operator and Accessory Site Plan 2 1 MyQ® Enabled ...Indoor Controls 2 Remote Controls 3 Photoelectric Sensors 4 Loop Detectors 5 Edge Sensors 6 Mounting Plate and Stand 7 Solar 8 Batteries 9 Heater 10 dwellingLIVE 1 10 7 5 3 6 89 4 LiftMaster gate operators ...
CSL24VDC Gate Operator and Accessory Site Plan Manual
Page 2
... Sensor Photoelectric Sensors Operator DUAL GATE Earth Ground Rod Check national and local codes for Close Cycle Commercial DC VEHICULAR SLIDE GATE OPERATOR Model CSL24VDC TYPICAL INSTALLATION NOTE: One or more non-contact sensors shall be located where the risk of nuisance tripping, such as a wall... Edge Sensor Photoelectric Sensors Earth Ground Rod Check national and local codes for proper depth © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com 01-37414B Operator NOTE: Wired connection in separate conduits. Any gap between the gate and a ...
... Sensor Photoelectric Sensors Operator DUAL GATE Earth Ground Rod Check national and local codes for Close Cycle Commercial DC VEHICULAR SLIDE GATE OPERATOR Model CSL24VDC TYPICAL INSTALLATION NOTE: One or more non-contact sensors shall be located where the risk of nuisance tripping, such as a wall... Edge Sensor Photoelectric Sensors Earth Ground Rod Check national and local codes for proper depth © 2014 LiftMaster All Rights Reserved 845 Larch Ave., Elmhurst, IL 60126 LiftMaster.com 01-37414B Operator NOTE: Wired connection in separate conduits. Any gap between the gate and a ...