XChip - User Guide
Page 10
...XP1001000-05R XP1002000-05R XP100200S-05R It provides the information needed to factory default values. Chapter Summary The remaining chapters in this guide include: Chapter Description 2: Introduction Describes the main features of the XPort and the protocols it supports. 3: Using DeviceInstaller Provides information for...Details the serial port settings. 8: Setup Mode: Advanced Settings Details email, expert, and security settings and explains how to reset the unit to configure, use, and update the XPort firmware and is intended for OEMs and system integrators who are embedding the...
...XP1001000-05R XP1002000-05R XP100200S-05R It provides the information needed to factory default values. Chapter Summary The remaining chapters in this guide include: Chapter Description 2: Introduction Describes the main features of the XPort and the protocols it supports. 3: Using DeviceInstaller Provides information for...Details the serial port settings. 8: Setup Mode: Advanced Settings Details email, expert, and security settings and explains how to reset the unit to configure, use, and update the XPort firmware and is intended for OEMs and system integrators who are embedding the...
APS: Modbus Protocol User Guide
Page 4
... Web Server 19 Enable Enhanced Password 19 Port 77F0 (Hex 19 Default Security Settings 19 4: Monitor Mode and Firmware 20 5: WiPort and WiBox Implementation 21 6: XPort Implementation 24 7: xPico Implementation 25 8: Micro125 Implementation 27 9: Factory Defaults with Reset Pin/Default Pin 28 Modbus Protocol User Guide 4
... Web Server 19 Enable Enhanced Password 19 Port 77F0 (Hex 19 Default Security Settings 19 4: Monitor Mode and Firmware 20 5: WiPort and WiBox Implementation 21 6: XPort Implementation 24 7: xPico Implementation 25 8: Micro125 Implementation 27 9: Factory Defaults with Reset Pin/Default Pin 28 Modbus Protocol User Guide 4
APS: Modbus Protocol User Guide
Page 10
...Device Server's Setup (configuration) screens (you enter the Monitor Mode and from the DHCP server. Using the Setup Mode Screen 1. To reset the parameters to the factory defaults, type D on the command line and press Enter. however if you will then get an IP address, a gateway address,... and a subnet mask from 0> prompt, type NC (upper case), the IP configuration of the IAP Device Server will display. . Lantronix Inc. - You have...
...Device Server's Setup (configuration) screens (you enter the Monitor Mode and from the DHCP server. Using the Setup Mode Screen 1. To reset the parameters to the factory defaults, type D on the command line and press Enter. however if you will then get an IP address, a gateway address,... and a subnet mask from 0> prompt, type NC (upper case), the IP configuration of the IAP Device Server will display. . Lantronix Inc. - You have...
APS: Modbus Protocol User Guide
Page 11
...auto-mapped to the factory default as shown above. Setup (Configuration) Mode Screen shows the main IAP Device Server configuration menu. Quit Without Saving (Q) Entering Q cancels any parameter changes you have made and exits configuration mode. This option triggers a reset. Setup (Configuration) ... offers three basic options. Although not required, selecting this option immediately after reloading the firmware and saving it ensures that the unit resets. Only the IP address does not change : Basic Commands (D/S/Q) Figure 3-1. Enabled (new MB/TCP requests queued in FIFO) MB...
...auto-mapped to the factory default as shown above. Setup (Configuration) Mode Screen shows the main IAP Device Server configuration menu. Quit Without Saving (Q) Entering Q cancels any parameter changes you have made and exits configuration mode. This option triggers a reset. Setup (Configuration) ... offers three basic options. Although not required, selecting this option immediately after reloading the firmware and saving it ensures that the unit resets. Only the IP address does not change : Basic Commands (D/S/Q) Figure 3-1. Enabled (new MB/TCP requests queued in FIFO) MB...
APS: Modbus Protocol User Guide
Page 21
.... GPIO assigns the pin as the UDS1100 or XPress-DR. The difference is an input read at startup that tells the firmware to reset configuration to toggle) GPIO (In) Invert (active low) (Y) ? Choose the serial port the firmware uses for Modem Control Settings is inverted (...or any key other platforms such as a general purpose input or output. Use serial connector (1=CH1 2=CH2) (1) ? CP0 Function (hit space to factory defaults. GPIO (Input) should be the default for each configurable pin. The options are then asked if the pin is replaced with Modem/Configurable Pin...
.... GPIO assigns the pin as the UDS1100 or XPress-DR. The difference is an input read at startup that tells the firmware to reset configuration to toggle) GPIO (In) Invert (active low) (Y) ? Choose the serial port the firmware uses for Modem Control Settings is inverted (...or any key other platforms such as a general purpose input or output. Use serial connector (1=CH1 2=CH2) (1) ? CP0 Function (hit space to factory defaults. GPIO (Input) should be the default for each configurable pin. The options are then asked if the pin is replaced with Modem/Configurable Pin...
APS: Modbus Protocol User Guide
Page 28
...factory default configuration. If the user presses the reset button for 3 to 5 seconds. 9: Factory Defaults with Reset Pin/Default Pin xPico Factory Defaults To restore the factory default configuration of the device server, press the reset pin for more than 10 seconds. The device server will load the factory...Modbus Protocol User Guide 28 Note: With factory default configuration, IP address, Gateway and Netmask are set to 5 seconds. Micro125 Factory Defaults To restore the factory default configuration of the device server, press the reset pin and then press the default pin for...
...factory default configuration. If the user presses the reset button for 3 to 5 seconds. 9: Factory Defaults with Reset Pin/Default Pin xPico Factory Defaults To restore the factory default configuration of the device server, press the reset pin for more than 10 seconds. The device server will load the factory...Modbus Protocol User Guide 28 Note: With factory default configuration, IP address, Gateway and Netmask are set to 5 seconds. Micro125 Factory Defaults To restore the factory default configuration of the device server, press the reset pin and then press the default pin for...