MatchPort b/g - User Guide
Page 18
... search for the list of Lantronix's CoBos operating system. In the right window, click the Web Configuration tab. 4. MatchPort User Guide 18 The unit performs a reset after the configuration is retained without power. Note: Alternatively, if the MatchPort is stored in a Web ...Web-Manager This chapter describes how to configure the MatchPort using DeviceInstaller Note: For more information on a standard release of available Lantronix device servers. 2. The unit's configuration is connected to a WLAN. The MatchPort NR supports only wired Ethernet interfaces; Accessing Web-...
... search for the list of Lantronix's CoBos operating system. In the right window, click the Web Configuration tab. 4. MatchPort User Guide 18 The unit performs a reset after the configuration is retained without power. Note: Alternatively, if the MatchPort is stored in a Web ...Web-Manager This chapter describes how to configure the MatchPort using DeviceInstaller Note: For more information on a standard release of available Lantronix device servers. 2. The unit's configuration is connected to a WLAN. The MatchPort NR supports only wired Ethernet interfaces; Accessing Web-...
MatchPort b/g - User Guide
Page 40
...channel 2. When you are finished, click the OK button. 4. MatchPort User Guide 40 Select whether the pin inputs or outputs. Usable as a trigger condition for at least 7 seconds resets the configuration back to factory defaults. Select whether the GPIO input ...the connection (and disconnection) of improper configuration. 3. Modem Ctrl Channel 2 In Allows for at least 7 seconds resets the configuration back to Defaults (Ethernet) *MatchPort b/g/ only Asserting during bootup for email. Serial Channel 2 Status Indicates channel 2 status and extended diagnostics when ...
...channel 2. When you are finished, click the OK button. 4. MatchPort User Guide 40 Select whether the pin inputs or outputs. Usable as a trigger condition for at least 7 seconds resets the configuration back to factory defaults. Select whether the GPIO input ...the connection (and disconnection) of improper configuration. 3. Modem Ctrl Channel 2 In Allows for at least 7 seconds resets the configuration back to Defaults (Ethernet) *MatchPort b/g/ only Asserting during bootup for email. Serial Channel 2 Status Indicates channel 2 status and extended diagnostics when ...
MatchPort b/g - User Guide
Page 42
.... From the Windows Start menu, click Run. 2. If using a terminal program to access serial port 1 locally. Click OK. The unit performs a reset after the configuration has been changed and stored. To enter the Setup Mode, press Enter within 5 seconds. 5. Note: The connection fails if you can...via Serial Mode or Telnet Port As an alternative to Web-Manager, you do not press Enter within 5 seconds. You can configure the MatchPort unit using Telnet from the main page list, and click the Telnet Configuration tab in the right page. Not all devices display information in ...
.... From the Windows Start menu, click Run. 2. If using a terminal program to access serial port 1 locally. Click OK. The unit performs a reset after the configuration has been changed and stored. To enter the Setup Mode, press Enter within 5 seconds. 5. Note: The connection fails if you can...via Serial Mode or Telnet Port As an alternative to Web-Manager, you do not press Enter within 5 seconds. You can configure the MatchPort unit using Telnet from the main page list, and click the Telnet Configuration tab in the right page. Not all devices display information in ...
MatchPort b/g - User Guide
Page 43
...in the Your choice ? To confirm a current value, press Enter (without save the new configurations (9 Save and exit). Reset the MatchPort unit by pressing Enter from the Change Setup menu. Connect a console terminal or PC running a terminal emulation program to ...V6.8.0.2 (120903) AES library version 1.8.2.1 Press Enter for a parameter, type the value and press Enter. To select a menu option, enter the number of resetting the MatchPort. Change Setup Menu Options Change Setup: 0 Server 1 Channel 1 2 Channel 2 3 E-mail 4 WLAN 5 Expert 6 Security 7 Defaults 8 Exit without ...
...in the Your choice ? To confirm a current value, press Enter (without save the new configurations (9 Save and exit). Reset the MatchPort unit by pressing Enter from the Change Setup menu. Connect a console terminal or PC running a terminal emulation program to ...V6.8.0.2 (120903) AES library version 1.8.2.1 Press Enter for a parameter, type the value and press Enter. To select a menu option, enter the number of resetting the MatchPort. Change Setup Menu Options Change Setup: 0 Server 1 Channel 1 2 Channel 2 3 E-mail 4 WLAN 5 Expert 6 Security 7 Defaults 8 Exit without ...
MatchPort b/g - User Guide
Page 73
... for protecting Telnet and Web Page access. The server configuration settings for the MatchPort b/g, wireless enable, infrastructure or ad hoc settings, and wireless security settings remain unchanged. Note: To reset network settings to factory defaults, use one of Telnet and web pages. Channel... default settings. Default Settings Select 7 Defaults from the Change Setup menu to reset the unit's Channel 1 configuration, Channel 2 configuration, Email settings, and Expert settings to set the eight MatchPort configurable pins when they are functioning as general purpose I /F Mode Port No...
... for protecting Telnet and Web Page access. The server configuration settings for the MatchPort b/g, wireless enable, infrastructure or ad hoc settings, and wireless security settings remain unchanged. Note: To reset network settings to factory defaults, use one of Telnet and web pages. Channel... default settings. Default Settings Select 7 Defaults from the Change Setup menu to reset the unit's Channel 1 configuration, Channel 2 configuration, Email settings, and Expert settings to set the eight MatchPort configurable pins when they are functioning as general purpose I /F Mode Port No...
MatchPort b/g - User Guide
Page 74
... Connection Type 0 (auto negotiate) 1 This is included in the 7 Defaults menu reset on Configurable Pins, see Configurable Pins. MatchPort User Guide 74 To reset the other parameters 5: Configuration via Serial Mode or Telnet Port 250 (msec) 0x0D (CR) 0 WLAN Settings (MatchPort b/g Only) Topology Network Name Channel Security TX Data Rate Auto Fallback1 TX...Port Number 25 MTU Size 1400 TCP Re-transmission Timeout (500- 500 (msec) 4000) Enable Alternate MAC N (No) ( for OEM use one of the "Reset to Defaults" Configurable Pin settings. For more information on the MatchPort b/g.
... Connection Type 0 (auto negotiate) 1 This is included in the 7 Defaults menu reset on Configurable Pins, see Configurable Pins. MatchPort User Guide 74 To reset the other parameters 5: Configuration via Serial Mode or Telnet Port 250 (msec) 0x0D (CR) 0 WLAN Settings (MatchPort b/g Only) Topology Network Name Channel Security TX Data Rate Auto Fallback1 TX...Port Number 25 MTU Size 1400 TCP Re-transmission Timeout (500- 500 (msec) 4000) Enable Alternate MAC N (No) ( for OEM use one of the "Reset to Defaults" Configurable Pin settings. For more information on the MatchPort b/g.
MatchPort b/g - User Guide
Page 82
... for Ethernet or BSSID, encryption, authentication for wireless interfaces, where applicable. Reports any stations found, including BSSID, SSID, and RSSI. MatchPort User Guide 82 Resets the unit. If the BSS does not broadcast its SSID, only the BSSID and RSSI are not overwritten). Pings unit with 192.168....0.10 = IP address of the MatchPort 8 = number of host bits 192.168.0.1 = gateway IP address 10001 = port number of the MatchPort 192.168.1.10...
... for Ethernet or BSSID, encryption, authentication for wireless interfaces, where applicable. Reports any stations found, including BSSID, SSID, and RSSI. MatchPort User Guide 82 Resets the unit. If the BSS does not broadcast its SSID, only the BSSID and RSSI are not overwritten). Pings unit with 192.168....0.10 = IP address of the MatchPort 8 = number of host bits 192.168.0.1 = gateway IP address 10001 = port number of the MatchPort 192.168.1.10...
MatchPort b/g - User Guide
Page 85
Note: See also Recovering Firmware in the DeviceInstaller User Guide. 1. MatchPort User Guide 85 8: Updating Firmware 6. The unit performs a power reset after the firmware has been loaded and stored. Start DeviceInstaller. 2. Using TFTP: Command Line Interface To download new firmware from a ...by using serial port 1 to download the file. From the Tools menu, select Advanced/Recover Firmware. Make sure Device Model indicates either MatchPort b/g or MatchPort NR. 4. Click OK to download the *.ROM file. Click the Upload Now button to transfer the file to the unit. The...
Note: See also Recovering Firmware in the DeviceInstaller User Guide. 1. MatchPort User Guide 85 8: Updating Firmware 6. The unit performs a power reset after the firmware has been loaded and stored. Start DeviceInstaller. 2. Using TFTP: Command Line Interface To download new firmware from a ...by using serial port 1 to download the file. From the Tools menu, select Advanced/Recover Firmware. Make sure Device Model indicates either MatchPort b/g or MatchPort NR. 4. Click OK to download the *.ROM file. Click the Upload Now button to transfer the file to the unit. The...
MatchPort b/g - Integration Guide
Page 4
... Diagram 8 PCB Interface 9 Mating Connector 9 Serial Input/Output 10 Sample Layouts for RS-485 Connectivity 11 WLAN Input/Output 12 MatchPort b/g 12 Power, Ground, and Reset 13 Absolute Maximum Ratings 13 Recommended Operating Conditions 13 Wireless Specifications 14 Technical Specifications 15 Dimensions 16 Recommended PCB Layout 18 Product Information Label 19... 21 Configuration Switch Bank 21 Demo Board Layout 23 Demo Board Schematics 24 A: Compliance and Warranty Information 28 Compliance Information 28 Warranty 29 MatchPort b/g Integration Guide 4
... Diagram 8 PCB Interface 9 Mating Connector 9 Serial Input/Output 10 Sample Layouts for RS-485 Connectivity 11 WLAN Input/Output 12 MatchPort b/g 12 Power, Ground, and Reset 13 Absolute Maximum Ratings 13 Recommended Operating Conditions 13 Wireless Specifications 14 Technical Specifications 15 Dimensions 16 Recommended PCB Layout 18 Product Information Label 19... 21 Configuration Switch Bank 21 Demo Board Layout 23 Demo Board Schematics 24 A: Compliance and Warranty Information 28 Compliance Information 28 Warranty 29 MatchPort b/g Integration Guide 4
MatchPort b/g - Integration Guide
Page 5
...WLAN Signals 12 Table 2-5. Operating Conditions, Serial Ports, & Configurable Pins 13 Table 2-8. Demo Board JP7 Jumper Configuration for CON2 22 Table 3-6. MatchPort b/g Block Diagram 8 Figure 2-2. Wireless Connector Dimensions 18 Figure 2-11. Technical Specifications 15 Table 3-1. Bottom View 17 Figure 2-10. JP9 ... 17 Figure 2-9. Separate RS-422 Transceivers for 2-Wire and 4-Wire Setups 12 Figure 2-7. Power, Ground, and Reset Pins 13 Table 2-6. Reverse-SMA to U.FL Cable (P/N 500-181-R 10 Figure 2-4. PCB Interface Signals 9 Table 2-2. Wireless Specifications 14 Table...
...WLAN Signals 12 Table 2-5. Operating Conditions, Serial Ports, & Configurable Pins 13 Table 2-8. Demo Board JP7 Jumper Configuration for CON2 22 Table 3-6. MatchPort b/g Block Diagram 8 Figure 2-2. Wireless Connector Dimensions 18 Figure 2-11. Technical Specifications 15 Table 3-1. Bottom View 17 Figure 2-10. JP9 ... 17 Figure 2-9. Separate RS-422 Transceivers for 2-Wire and 4-Wire Setups 12 Figure 2-7. Power, Ground, and Reset Pins 13 Table 2-6. Reverse-SMA to U.FL Cable (P/N 500-181-R 10 Figure 2-4. PCB Interface Signals 9 Table 2-2. Wireless Specifications 14 Table...
MatchPort b/g - Integration Guide
Page 9
...all the configurable pins, see the MatchPort b/g User Guide for selectable functions. Figure 2-2. PCB Interface Signals Name Reset IN# NC TXD1 RTS1 RXD1 CTS1 CP1 CP2 CP3 CP4 TXD2 RTS2 RXD2 CTS2 CP5 CP6 CP7 CP8 3.3V GND Function Active low Reset. Lantronix offers two cable options, reverse-SMA... to U.FL (P/N 500-180-R) or U.FL to U.FL (P/N 500-180-R) MatchPort b/g Integration Guide 9 No Connect Transmit data output (logic level), port 0 Request to Send...
...all the configurable pins, see the MatchPort b/g User Guide for selectable functions. Figure 2-2. PCB Interface Signals Name Reset IN# NC TXD1 RTS1 RXD1 CTS1 CP1 CP2 CP3 CP4 TXD2 RTS2 RXD2 CTS2 CP5 CP6 CP7 CP8 3.3V GND Function Active low Reset. Lantronix offers two cable options, reverse-SMA... to U.FL (P/N 500-180-R) or U.FL to U.FL (P/N 500-180-R) MatchPort b/g Integration Guide 9 No Connect Transmit data output (logic level), port 0 Request to Send...
MatchPort b/g - Integration Guide
Page 13
...Max 3.45 2 0.8 5.5 +/- 1 µA 0.4 4.3 Units V % V V V V mA 7.1 8.5 mA -6.4 -10.0 mA -6.4 -10.0 mA MatchPort b/g Integration Guide 13 Table 2-7. 2: Description and Specifications Power, Ground, and Reset Table 2-5. Absolute Maximum Ratings Table 2-6. Absolute Maximum Ratings Parameter Supply Voltage Input Voltage Output Voltage Operating Temperature Storage Temperature Min... Operating Conditions The following table illustrates the optimal and recommended operating conditions for the MatchPort b/g device. Power, Ground, and Reset Pins Power Pin 37 Ground Pin 2 Pin 39...
...Max 3.45 2 0.8 5.5 +/- 1 µA 0.4 4.3 Units V % V V V V mA 7.1 8.5 mA -6.4 -10.0 mA -6.4 -10.0 mA MatchPort b/g Integration Guide 13 Table 2-7. 2: Description and Specifications Power, Ground, and Reset Table 2-5. Absolute Maximum Ratings Table 2-6. Absolute Maximum Ratings Parameter Supply Voltage Input Voltage Output Voltage Operating Temperature Storage Temperature Min... Operating Conditions The following table illustrates the optimal and recommended operating conditions for the MatchPort b/g device. Power, Ground, and Reset Pins Power Pin 37 Ground Pin 2 Pin 39...
MatchPort b/g - Integration Guide
Page 15
... 3.3V) Security Weight Cover Material Temperature Warranty Included Software MatchPort b/g Lantronix DSTni-EX 186 CPU, 256 KB zero wait state SRAM 2048 KB Flash,16 KB Boot ROM Upgradeable via TFTP and serial port Reset In is 2 ms at IIL = -500 µA CMOS (Asynchronous) 3.3V - MatchPort b/g Integration Guide 15 2: Description and Specifications Technical Specifications...
... 3.3V) Security Weight Cover Material Temperature Warranty Included Software MatchPort b/g Lantronix DSTni-EX 186 CPU, 256 KB zero wait state SRAM 2048 KB Flash,16 KB Boot ROM Upgradeable via TFTP and serial port Reset In is 2 ms at IIL = -500 µA CMOS (Asynchronous) 3.3V - MatchPort b/g Integration Guide 15 2: Description and Specifications Technical Specifications...