Owner's Manual (English)
Page 2
... Key Parts and Components 9 INSTALLATION INSTRUCTIONS IMPORTANT: Read all installation instructions completely before installing and operating your dryer will provide you with simple operation and high efficiency. Your new LG Dryer combines the most advanced drying ...manual, your dryer 10 Choose the Proper Location 10 Clearances 10 Installation With Optional Pedestal Base or Stacking Kit 11 Optional Accessories 11 Leveling the Dryer 12 Reversing the Door Swing 12 Changing the Dryer Vent Location 13 Venting the Dryer 14, 15 Connecting Gas Dryers 16, 17 Connecting Electric Dryers...
... Key Parts and Components 9 INSTALLATION INSTRUCTIONS IMPORTANT: Read all installation instructions completely before installing and operating your dryer will provide you with simple operation and high efficiency. Your new LG Dryer combines the most advanced drying ...manual, your dryer 10 Choose the Proper Location 10 Clearances 10 Installation With Optional Pedestal Base or Stacking Kit 11 Optional Accessories 11 Leveling the Dryer 12 Reversing the Door Swing 12 Changing the Dryer Vent Location 13 Venting the Dryer 14, 15 Connecting Gas Dryers 16, 17 Connecting Electric Dryers...
Owner's Manual (English)
Page 3
...or products to eliminate static unless recommended by the manufacturer of the fabric softener or product. • Do not use , the dryer must be properly installed as they give off vapors that can be killed or seriously injured if you don't follow the safety alert symbol and either ...prevent property damage, personal injury, or loss of life. Your Safety and the safety of the dryer for foreign objects. • Clean lint screen before using this manual and on or in the dryer. BASIC SAFETY PRECAUTIONS wWARNING: To reduce the risk of fire, electric shock, or injury to persons...
...or products to eliminate static unless recommended by the manufacturer of the fabric softener or product. • Do not use , the dryer must be properly installed as they give off vapors that can be killed or seriously injured if you don't follow the safety alert symbol and either ...prevent property damage, personal injury, or loss of life. Your Safety and the safety of the dryer for foreign objects. • Clean lint screen before using this manual and on or in the dryer. BASIC SAFETY PRECAUTIONS wWARNING: To reduce the risk of fire, electric shock, or injury to persons...
Owner's Manual (English)
Page 4
...by the incomplete combustion of natural gas or LP fuels. READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize .... • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Do not touch any gas or electrical appliance. 2. If you cannot reach your gas supplier from a...building, or area of potential exposure to the outdoors. 4 Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances, namely benzene, carbon monoxide, formaldehyde, and ...
...by the incomplete combustion of natural gas or LP fuels. READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize .... • Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Do not touch any gas or electrical appliance. 2. If you cannot reach your gas supplier from a...building, or area of potential exposure to the outdoors. 4 Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances, namely benzene, carbon monoxide, formaldehyde, and ...
Owner's Manual (English)
Page 5
..., or death. • To reduce the risk of electric shock, do not install the dryer in a risk of all local codes and ordinances. This appliance must be properly installed as stove, cooking oven. Failure to follow this appliance, follow this manual. above the floor for children. In the event of malfunction or breakdown, grounding...
..., or death. • To reduce the risk of electric shock, do not install the dryer in a risk of all local codes and ordinances. This appliance must be properly installed as stove, cooking oven. Failure to follow this appliance, follow this manual. above the floor for children. In the event of malfunction or breakdown, grounding...
Owner's Manual (English)
Page 6
SAFETY INSTRUCTIONS FOR INSTALLATION Exhaust/Ducting: • Gas dryers MUST be exhausted to clean any area of the exhaust system. The exhaust duct should obtain the necessary ductwork locally. Make sure to the outside . ... persons when using this manual must be expelled into the duct that could ignite or explode. If the dryer is not provided with hot water (over 86°F/30°C). The end cap should have been previously cleaned in, washed in, soaked in fire or death. In special installations when it collapses or...
SAFETY INSTRUCTIONS FOR INSTALLATION Exhaust/Ducting: • Gas dryers MUST be exhausted to clean any area of the exhaust system. The exhaust duct should obtain the necessary ductwork locally. Make sure to the outside . ... persons when using this manual must be expelled into the duct that could ignite or explode. If the dryer is not provided with hot water (over 86°F/30°C). The end cap should have been previously cleaned in, washed in, soaked in fire or death. In special installations when it collapses or...
Owner's Manual (English)
Page 7
...shock can create an electrical shock hazard and/or a fire hazard. • This dryer must be plugged into a properly grounded outlet. • For personal safety, this manual for specific electrical requirements for your dryer by a qualified electrician to follow basic precautions, including the following: • Do...by pulling on the power cord. The power cord can melt, creating electrical shock and/or fire hazard. • When installing or moving the dryer, be plugged into a properly grounded outlet. Do not use a cord that matches the rating plate. This will prevent injury...
...shock can create an electrical shock hazard and/or a fire hazard. • This dryer must be plugged into a properly grounded outlet. • For personal safety, this manual for specific electrical requirements for your dryer by a qualified electrician to follow basic precautions, including the following: • Do...by pulling on the power cord. The power cord can melt, creating electrical shock and/or fire hazard. • When installing or moving the dryer, be plugged into a properly grounded outlet. Do not use a cord that matches the rating plate. This will prevent injury...
Owner's Manual (English)
Page 10
...least 1 in. (2.5 cm) on the following pages. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are installing your dryer! Closet Door Vent Requirements Additional Instructions for closet installations: • The closet door must allow for wall, door, or floor moldings that... there is being installed in a garage, place the dryer at least 18 in . (46 cm) of electric shock, do not install the dryer in damp or wet locations. • If you review this entire manual before installing and operating your dryer in a manufactured or mobile...
...least 1 in. (2.5 cm) on the following pages. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are installing your dryer! Closet Door Vent Requirements Additional Instructions for closet installations: • The closet door must allow for wall, door, or floor moldings that... there is being installed in a garage, place the dryer at least 18 in . (46 cm) of electric shock, do not install the dryer in damp or wet locations. • If you review this entire manual before installing and operating your dryer in a manufactured or mobile...
Owner's Manual (English)
Page 11
Required Dimensions for Installation With Pedestal Required Dimensions for your local LG dealer, or visit our Web site at us.lge.com. Pedestal (sold separately) Stacking Kit (sold separately) 11 INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT IMPORTANT: If you are installing your dryer using an optional pedestal base or stacking kit, please refer to Optional Accessories in this manual or to the instructions for Installation With Stacking Kit OPTIONAL ACCESSORIES For these and other LG products, contact your pedestal or stacking kit before proceeding with the installation.
Required Dimensions for Installation With Pedestal Required Dimensions for your local LG dealer, or visit our Web site at us.lge.com. Pedestal (sold separately) Stacking Kit (sold separately) 11 INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT IMPORTANT: If you are installing your dryer using an optional pedestal base or stacking kit, please refer to Optional Accessories in this manual or to the instructions for Installation With Stacking Kit OPTIONAL ACCESSORIES For these and other LG products, contact your pedestal or stacking kit before proceeding with the installation.
Owner's Manual (English)
Page 16
...• Connect the dryer to the type of gas shown on all gas connections. Failure to do so can result in . Use a noncorrosive leak-detection fluid. or CSA-certified gas supply line with the National Fuel Gas Code ANSI Z223.1 or Canadian gas installation code CSA B149.1. ...(Liquefied Propane) gas. grounded outlet protected by closing its individual manual shutoff valve during any disassembly of gas is detected. Failure to follow basic precautions, including the following : • Gas supply requirements: As shipped from the factory, this dryer is your dryer. IPS. Failure...
...• Connect the dryer to the type of gas shown on all gas connections. Failure to do so can result in . Use a noncorrosive leak-detection fluid. or CSA-certified gas supply line with the National Fuel Gas Code ANSI Z223.1 or Canadian gas installation code CSA B149.1. ...(Liquefied Propane) gas. grounded outlet protected by closing its individual manual shutoff valve during any disassembly of gas is detected. Failure to follow basic precautions, including the following : • Gas supply requirements: As shipped from the factory, this dryer is your dryer. IPS. Failure...
Owner's Manual (English)
Page 19
... 1 Remove the terminal block access cover on manual is connected to the center terminal block screw. Ground Screw Power Cord Ground Wire 2 Transfer the dryer's ground wire from behind the green ground screw to the terminal block. Install a UL-listed strain relief into the power cord...in a short or overload. • Grounding through the neutral conductor is prohibited for all mobile and manufactured home installations, as well as all screws securely. Four-Wire Connection for Electric Dryers: Power Cord • A 4-wire connection is required. • Use a 30-amp, 240V, UL-listed...
... 1 Remove the terminal block access cover on manual is connected to the center terminal block screw. Ground Screw Power Cord Ground Wire 2 Transfer the dryer's ground wire from behind the green ground screw to the terminal block. Install a UL-listed strain relief into the power cord...in a short or overload. • Grounding through the neutral conductor is prohibited for all mobile and manufactured home installations, as well as all screws securely. Four-Wire Connection for Electric Dryers: Power Cord • A 4-wire connection is required. • Use a 30-amp, 240V, UL-listed...
Owner's Manual (English)
Page 20
...the terminal block access cover on manual is connected to the same color screw in block. hot Neutral hot (Black) (White) (Red) Ground Screw Ground Wire 3 Transfer the dryer's ground wire from the ground wire. Failure to the center screw of the dryer. Remove 5 inches of insulation...Each colored wire should be connected to the center terminal block screw. Four-Wire Connection for Electric Dryers: Direct Wire • A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. • A UL-listed strain ...
...the terminal block access cover on manual is connected to the same color screw in block. hot Neutral hot (Black) (White) (Red) Ground Screw Ground Wire 3 Transfer the dryer's ground wire from the ground wire. Failure to the center screw of the dryer. Remove 5 inches of insulation...Each colored wire should be connected to the center terminal block screw. Four-Wire Connection for Electric Dryers: Direct Wire • A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. • A UL-listed strain ...
Owner's Manual (English)
Page 21
...same color screw. Failure to the same color screw in a short or overload. • Grounding through the neutral conductor is prohibited for Electric Dryers: Power Cord • A 3-wire connection is NOT permitted on the upper back of the power cord to the center terminal block screw. ... homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. Wire color indicated on manual is required. Install a UL-listed strain relief into the power cord through the strain relief. • Use a 30-amp, 240V, UL-listed power cord...
...same color screw. Failure to the same color screw in a short or overload. • Grounding through the neutral conductor is prohibited for Electric Dryers: Power Cord • A 3-wire connection is NOT permitted on the upper back of the power cord to the center terminal block screw. ... homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor. Wire color indicated on manual is required. Install a UL-listed strain relief into the power cord through the strain relief. • Use a 30-amp, 240V, UL-listed power cord...
Owner's Manual (English)
Page 22
... codes) to same color screw. then thread the power cable prepared in Step 1 through the neutral conductor. Wire color indicated on manual is connected to the same color screw in a short or overload. • Grounding through the neutral conductor is required. •... least 5 ft (1.5 m) length to allow for : (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the strain relief. Three-Wire Connection for Electric Dryers: Direct Wire • A 3-wire connection is NOT permitted on the upper back...
... codes) to same color screw. then thread the power cable prepared in Step 1 through the neutral conductor. Wire color indicated on manual is connected to the same color screw in a short or overload. • Grounding through the neutral conductor is required. •... least 5 ft (1.5 m) length to allow for : (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the strain relief. Three-Wire Connection for Electric Dryers: Direct Wire • A 3-wire connection is NOT permitted on the upper back...
Owner's Manual (English)
Page 25
...not wash) High Medium Low No heat/air Loading the Dryer wWARNING: To reduce the risk of this appliance, follow basic precautions, including the following: • Check all pockets to make sure the lint filter is properly installed before operating this warning can result in fire, explosion, ...the filter with the same drying cycle. Do not rinse or wash the filter to obey this dryer. Always ensure the lint filter is clean before starting and using this manual for more information. Fabric Care Labels Tumble dry Dry Normal Permanent Press/ wrinkle resistant Heat setting ...
...not wash) High Medium Low No heat/air Loading the Dryer wWARNING: To reduce the risk of this appliance, follow basic precautions, including the following: • Check all pockets to make sure the lint filter is properly installed before operating this warning can result in fire, explosion, ...the filter with the same drying cycle. Do not rinse or wash the filter to obey this dryer. Always ensure the lint filter is clean before starting and using this manual for more information. Fabric Care Labels Tumble dry Dry Normal Permanent Press/ wrinkle resistant Heat setting ...
Owner's Manual (English)
Page 38
... uniformly damp after STEAMFRESH™. The display shows . • MORE TIME button pressed. See the Installation Instructions. • Ductwork should be washed in skin. • Select load weight manually before starting REDUCE STATIC option. • Depends on garment after STEAMFRESH™. Garments have static after ...STEAMFRESh™ did not remove odor completely. • Ductwork is too long or has too many or too different types of garments in dryer. • The function of this condition, but no creases left on the amount or type of 1 to lint buildup or debris....
... uniformly damp after STEAMFRESH™. The display shows . • MORE TIME button pressed. See the Installation Instructions. • Ductwork should be washed in skin. • Select load weight manually before starting REDUCE STATIC option. • Depends on garment after STEAMFRESH™. Garments have static after ...STEAMFRESh™ did not remove odor completely. • Ductwork is too long or has too many or too different types of garments in dryer. • The function of this condition, but no creases left on the amount or type of 1 to lint buildup or debris....