Product Guide
Page 3
Contents 1 Description Server Board Features ...7 Server Board Connector and Component Locations 8 Back Panel Connectors 9 Processor ...10 Memory ...10 PCI Riser Slots ...10 Video ...11 SCSI Controller ...11 ATA-100 Controller...11 IDE RAID...11 Network Controller...12 Network Teaming Features 12 Keyboard and Mouse ...14 RJ-45 Serial Port ...14 ...
Contents 1 Description Server Board Features ...7 Server Board Connector and Component Locations 8 Back Panel Connectors 9 Processor ...10 Memory ...10 PCI Riser Slots ...10 Video ...11 SCSI Controller ...11 ATA-100 Controller...11 IDE RAID...11 Network Controller...12 Network Teaming Features 12 Keyboard and Mouse ...14 RJ-45 Serial Port ...14 ...
Product Guide
Page 4
... If BIOS Setup Is Inaccessible 44 BIOS Setup Menus...44 Main Menu...45 Advanced Menu...46 Security Menu...49 Server Menu ...50 Boot Menu ...52 Exit Menu ...53 Temporarily Changing the Boot Device Priority 53 Permanently Changing the... When to Run the Adaptec SCSISelect Utility 54 Running the SCSISelect Utility 54 Configuring the Adaptec AIC-7899 SCSI Adapter 55 Running the Promise FastBuild Utility 55 When to Run the Promise FastBuild Utility 56 Running the ... 77 Firmware Update Utility Description 79 FRU/SDR Load Utility Description 79 iv Intel Server Board SCB2 Product Guide
... If BIOS Setup Is Inaccessible 44 BIOS Setup Menus...44 Main Menu...45 Advanced Menu...46 Security Menu...49 Server Menu ...50 Boot Menu ...52 Exit Menu ...53 Temporarily Changing the Boot Device Priority 53 Permanently Changing the... When to Run the Adaptec SCSISelect Utility 54 Running the SCSISelect Utility 54 Configuring the Adaptec AIC-7899 SCSI Adapter 55 Running the Promise FastBuild Utility 55 When to Run the Promise FastBuild Utility 56 Running the ... 77 Firmware Update Utility Description 79 FRU/SDR Load Utility Description 79 iv Intel Server Board SCB2 Product Guide
Product Guide
Page 7
...; One external SCSI port (SCSI server board only), one Low Profile (LP) 64-bit/66-MHz PCI riser slot. • 2U configuration-three full-length, full-height 64-bit/66-MHz PCI riser slots and three LP 64-bit/66-MHz PCI riser slots. 1 Description Server Board Features The SCB2 is available in either the 1U Intel®...; SR1200 or the 2U Intel® SR2200 server chassis.
...; One external SCSI port (SCSI server board only), one Low Profile (LP) 64-bit/66-MHz PCI riser slot. • 2U configuration-three full-length, full-height 64-bit/66-MHz PCI riser slots and three LP 64-bit/66-MHz PCI riser slots. 1 Description Server Board Features The SCB2 is available in either the 1U Intel®...; SR1200 or the 2U Intel® SR2200 server chassis.
Product Guide
Page 8
... connector M. CPU 2 fan connector EE. Primary processor socket GG. Server Board Connector and Component Locations 8 Intel Server Board SCB2 Product Guide ID LED S. Aux fan connector D. Fan module connector ...F. COM 1 serial header Z. ATA-100 connectors (ATA version only) O. Hard Disk Drive LED header Q. ICMB connector Y. Sys fan 3 connector DD. Diagnostic LEDs (POST code) U. Sys fan 2 connector Figure 1. Figure 1 is a composite view of both SCSI...
... connector M. CPU 2 fan connector EE. Primary processor socket GG. Server Board Connector and Component Locations 8 Intel Server Board SCB2 Product Guide ID LED S. Aux fan connector D. Fan module connector ...F. COM 1 serial header Z. ATA-100 connectors (ATA version only) O. Hard Disk Drive LED header Q. ICMB connector Y. Sys fan 3 connector DD. Diagnostic LEDs (POST code) U. Sys fan 2 connector Figure 1. Figure 1 is a composite view of both SCSI...
Product Guide
Page 9
PS/2 keyboard/mouse connector K. Yellow Status LED G. Video connector C. NIC 2 RJ-45 connector E. NIC 1 RJ-45 connector H. Yellow Status LED J. USB 1 connector B. Green Status LED I G OM11713 A. USB 2 connector Figure 2. RJ-45 serial port L. Back Panel Connectors A B C JK L D E F H I . Back Panel Connectors Description 9 Green Status LED F. SCSI connector (SCSI server board only) D.
PS/2 keyboard/mouse connector K. Yellow Status LED G. Video connector C. NIC 2 RJ-45 connector E. NIC 1 RJ-45 connector H. Yellow Status LED J. USB 1 connector B. Green Status LED I G OM11713 A. USB 2 connector Figure 2. RJ-45 serial port L. Back Panel Connectors A B C JK L D E F H I . Back Panel Connectors Description 9 Green Status LED F. SCSI connector (SCSI server board only) D.
Product Guide
Page 11
Video The SCB2 uses an ATI RAGE XL PCI graphics accelerator with 8 MB of the Promise Technology† PDC20267 ATA-100 controller. ATA-100 Controller The ATA version of the server board provides an embedded dual channel ATA-100 bus through the use of video SDRAM that supports all standard IBM... array is seen as an independent disk, though the array may include one end of the bus. The SCSI bus is installed in and need to have termination built-in any of the server board includes an embedded Adaptec† AIC-7899W controller providing dual Ultra160 Low Voltage Differential (LVD...
Video The SCB2 uses an ATI RAGE XL PCI graphics accelerator with 8 MB of the Promise Technology† PDC20267 ATA-100 controller. ATA-100 Controller The ATA version of the server board provides an embedded dual channel ATA-100 bus through the use of video SDRAM that supports all standard IBM... array is seen as an independent disk, though the array may include one end of the bus. The SCSI bus is installed in and need to have termination built-in any of the server board includes an embedded Adaptec† AIC-7899W controller providing dual Ultra160 Low Voltage Differential (LVD...
Product Guide
Page 30
... only) K. COM 1 header L. Front panel connector (For use in a non Intel chassis only) E. A S C S I . Combined Floppy/Front Panel/IDE connector (For use in an Intel chassis only) 30 Intel Server Board SCB2 Product Guide Fan module connector (7-pin) H. SCSI connector (SCSI server board only) B. USB header J. Main power connector G. Fan connectors (system and processor) I AB T A 1 0 0 C D A E T A 6 6 G F H C O M K 1 J U SI B OM11717 Figure 16. Connect Cables...
... only) K. COM 1 header L. Front panel connector (For use in a non Intel chassis only) E. A S C S I . Combined Floppy/Front Panel/IDE connector (For use in an Intel chassis only) 30 Intel Server Board SCB2 Product Guide Fan module connector (7-pin) H. SCSI connector (SCSI server board only) B. USB header J. Main power connector G. Fan connectors (system and processor) I AB T A 1 0 0 C D A E T A 6 6 G F H C O M K 1 J U SI B OM11717 Figure 16. Connect Cables...
Product Guide
Page 42
... Enter the Promise Technology IDE RAID Utility. The CSSU is updating memory size on the system board from the CD. Firmware Update Utility Use to access and monitor the server remotely. Enter BIOS Setup during POST. Table 5. To remove the splash screen. FRU/SDR ...setting system security options. The SSU can move the CMOS jumper on screen.) (Press anytime after memory check.) 42 Intel Server Board SCB2 Product Guide Enter the Adaptec SCSI Utility during POST. It provides the same functionality as the SSU, but from a set of onboard resources, setting ...
... Enter the Promise Technology IDE RAID Utility. The CSSU is updating memory size on the system board from the CD. Firmware Update Utility Use to access and monitor the server remotely. Enter BIOS Setup during POST. Table 5. To remove the splash screen. FRU/SDR ...setting system security options. The SSU can move the CMOS jumper on screen.) (Press anytime after memory check.) 42 Intel Server Board SCB2 Product Guide Enter the Adaptec SCSI Utility during POST. It provides the same functionality as the SSU, but from a set of onboard resources, setting ...
Product Guide
Page 43
... run BIOS Setup to be stored in RTC) • Configure hard drive(s) • Specify boot device sequence • Enable SCSI BIOS • Enable Server Management Features • Setup system passwords Configuration Software and Utilities 43 POST is displayed: • Press to enter the BIOS Setup... battery-backed CMOS; Turn on page 53.) 3. After pressing or during POST, you can run the SCSISelect Utility. The system searches all server board features, such as: • Defining the diskette drive • Defining the serial port(s) • Set time/date (to specify the ...
... run BIOS Setup to be stored in RTC) • Configure hard drive(s) • Specify boot device sequence • Enable SCSI BIOS • Enable Server Management Features • Setup system passwords Configuration Software and Utilities 43 POST is displayed: • Press to enter the BIOS Setup... battery-backed CMOS; Turn on page 53.) 3. After pressing or during POST, you can run the SCSISelect Utility. The system searches all server board features, such as: • Defining the diskette drive • Defining the serial port(s) • Set time/date (to specify the ...
Product Guide
Page 47
...Press Enabled Disabled Description Enters Submenu Enters Submenu Enters Submenu Enters Submenu (SCSI model only) Enters Submenu (ATA model only) Enters Submenu This option will only be displayed if a non-Intel chassis is turned off and the device resources are hidden from the... Disabled Description If disabled, the embedded R-IDE device is used. Onboard SCSI Submenu Feature Onboard SCSI Embedded LVD SCSI ROM Choices Enabled Disabled Enabled Disabled Description Enables or disables embedded legacy SCSI controller hardware. Enables the device option ROM. If enabled, all six ...
...Press Enabled Disabled Description Enters Submenu Enters Submenu Enters Submenu Enters Submenu (SCSI model only) Enters Submenu (ATA model only) Enters Submenu This option will only be displayed if a non-Intel chassis is turned off and the device resources are hidden from the... Disabled Description If disabled, the embedded R-IDE device is used. Onboard SCSI Submenu Feature Onboard SCSI Embedded LVD SCSI ROM Choices Enabled Disabled Enabled Disabled Description Enables or disables embedded legacy SCSI controller hardware. Enables the device option ROM. If enabled, all six ...
Product Guide
Page 54
...step 4. 6. Enter Setup. 2. When this time allows you to configure the Adaptec AIC-7899 SCSI host adapter. These changes are saved from , then press the key to move it to 15 devices. 54 Intel Server Board SCB2 Product Guide In the Boot Device Priority screen, use the up to the top of the... host adapter and devices in the server. The system finds the Adaptec AIC-7899 SCSI host adapter and displays the message Adaptec AIC-7899...
...step 4. 6. Enter Setup. 2. When this time allows you to configure the Adaptec AIC-7899 SCSI host adapter. These changes are saved from , then press the key to move it to 15 devices. 54 Intel Server Board SCB2 Product Guide In the Boot Device Priority screen, use the up to the top of the... host adapter and devices in the server. The system finds the Adaptec AIC-7899 SCSI host adapter and displays the message Adaptec AIC-7899...
Product Guide
Page 55
... the FastBuild†configuration utility that allows you to reboot Press any key, and the server reboots. SCSI Disk Utilities Press to view the Configuration Menu. The Promise ATA-100 host adapter is only found on the SCB2 ATA model only. Bus:Device:Channel 01:06:A 01:06:B - This menu allows you ...to configure/view the settings of the one for each SCSI Channel Host Adapter Option Comment AIC-7899 at Bus:Device:Channel 01:06...
... the FastBuild†configuration utility that allows you to reboot Press any key, and the server reboots. SCSI Disk Utilities Press to view the Configuration Menu. The Promise ATA-100 host adapter is only found on the SCB2 ATA model only. Bus:Device:Channel 01:06:A 01:06:B - This menu allows you ...to configure/view the settings of the one for each SCSI Channel Host Adapter Option Comment AIC-7899 at Bus:Device:Channel 01:06...
Product Guide
Page 105
See utilities configuring server board jumpers location on server board, 91 configuring system BIOS Setup, 42 System Setup Utility, 42 controller, 92, 94 keyboard/mouse, 14 network, 7 SCSI, 11 video, 7, 11 D diagnostics, preparing system for testing, 85 Direct Platform Control, 56 modes of safely, 39 ...changing permanently, 54 changing priority, 42 changing temporarily, 53 setting in Setup, 19 booting cold, 83 BSP, 92 bus termination requirements, SCSI devices, 11 C Caution avoid damaging jumpers when changing, 32 avoid touching processor pins, 33 selecting correct processor, 33 Checksum, 92 ...
See utilities configuring server board jumpers location on server board, 91 configuring system BIOS Setup, 42 System Setup Utility, 42 controller, 92, 94 keyboard/mouse, 14 network, 7 SCSI, 11 video, 7, 11 D diagnostics, preparing system for testing, 85 Direct Platform Control, 56 modes of safely, 39 ...changing permanently, 54 changing priority, 42 changing temporarily, 53 setting in Setup, 19 booting cold, 83 BSP, 92 bus termination requirements, SCSI devices, 11 C Caution avoid damaging jumpers when changing, 32 avoid touching processor pins, 33 selecting correct processor, 33 Checksum, 92 ...
Product Guide
Page 106
... Setup, 53 F fan, heat sink, disconnecting, 34, 37, 38 Fast EtherChannel, 13, 14 FEC. E Embedded Legacy SCSI submenu, configuring in BIOS Setup, 47 Embedded NIC submenu, configuring in BIOS Setup, 47 Embedded Video Controller submenu, configuring in BIOS...48 Emergency Management Port Console, 42 Emergency Management Port Dialog, 72 equipment log, 99 Error, 94, 95 ESD add-in boards, 31 avoiding damage to reactivate keyboard/mouse, 14 Password, 94 PCI embedded devices, 7 expansion slots, 7 PGA370, 10... DC power, 102 Power-on Self-Test, See POST, 94, 95 106 Intel Server Board SCB2 Product Guide
... Setup, 53 F fan, heat sink, disconnecting, 34, 37, 38 Fast EtherChannel, 13, 14 FEC. E Embedded Legacy SCSI submenu, configuring in BIOS Setup, 47 Embedded NIC submenu, configuring in BIOS Setup, 47 Embedded Video Controller submenu, configuring in BIOS...48 Emergency Management Port Console, 42 Emergency Management Port Dialog, 72 equipment log, 99 Error, 94, 95 ESD add-in boards, 31 avoiding damage to reactivate keyboard/mouse, 14 Password, 94 PCI embedded devices, 7 expansion slots, 7 PGA370, 10... DC power, 102 Power-on Self-Test, See POST, 94, 95 106 Intel Server Board SCB2 Product Guide
Product Guide
Page 107
... Platform Control Removable Devices Selection submenu, configuring in BIOS Setup, 52, 53 removing termination board, 34, 38 Reset, 93 reset system, 83 RTC, 93 S SCSI bus termination requirements, 11 SCSISelect utility, 54 SCSI controller, 11 SCU administrative password limits access to, 19 inactivity (lockout) timer, 14 ...Add-in, 60 Security menu, configuring in BIOS Setup, 49 SEL, See System Event Log, 62 SEL Manager Add-in, 62 server board, configurations, 91 server management, intrusion detection, 17 Signal Data Terminal Ready, 15 DCD, 15 DSR, 15 Received Data, 15 Request to run SSU, 42...
... Platform Control Removable Devices Selection submenu, configuring in BIOS Setup, 52, 53 removing termination board, 34, 38 Reset, 93 reset system, 83 RTC, 93 S SCSI bus termination requirements, 11 SCSISelect utility, 54 SCSI controller, 11 SCU administrative password limits access to, 19 inactivity (lockout) timer, 14 ...Add-in, 60 Security menu, configuring in BIOS Setup, 49 SEL, See System Event Log, 62 SEL Manager Add-in, 62 server board, configurations, 91 server management, intrusion detection, 17 Signal Data Terminal Ready, 15 DCD, 15 DSR, 15 Received Data, 15 Request to run SSU, 42...