Page 12
... Not Rotate Properly 50 CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light 50 Cannot Connect to a Server 51 Problems with Network 51 System Boots when Installing PCI Card 52 Problems with Newly Installed Application Software 52 Problems with Application Software that Ran Correctly Earlier 53 Devices are not...-ROM Disk Is Not Detected 54 LED Information ...54 BIOS POST Beep Codes 54 Appendix B: Regulatory and Compliance Information 57 Product Regulatory Compliance 57 xii Intel® Server Board S5000PSL
... Not Rotate Properly 50 CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light 50 Cannot Connect to a Server 51 Problems with Network 51 System Boots when Installing PCI Card 52 Problems with Newly Installed Application Software 52 Problems with Application Software that Ran Correctly Earlier 53 Devices are not...-ROM Disk Is Not Detected 54 LED Information ...54 BIOS POST Beep Codes 54 Appendix B: Regulatory and Compliance Information 57 Product Regulatory Compliance 57 xii Intel® Server Board S5000PSL
User Guide
Page 20
...; Sys Fan 6 Sys Fan 3 and Sys Fan 4 are compatible with all fan headers. 4-pin fans should be used only with the following list • Two PCI Express* x4 slots (product code S5000PSLSAS or S5000PSLSASR) • Two PCI Express x8 slots (product code S5000PSLSATA, S5000PSLSATAR, S5000XSLSATA, or S5000XSLSATAR) 2 Intel® Server Board S5000PSL
...; Sys Fan 6 Sys Fan 3 and Sys Fan 4 are compatible with all fan headers. 4-pin fans should be used only with the following list • Two PCI Express* x4 slots (product code S5000PSLSAS or S5000PSLSASR) • Two PCI Express x8 slots (product code S5000PSLSATA, S5000PSLSATAR, S5000XSLSATA, or S5000XSLSATAR) 2 Intel® Server Board S5000PSL
User Guide
Page 22
.... Uses specially keyed PCI Express slot, add-in card slot 4. - When the optional Intel® Activation KEY AXXRAK18E and RAM are installed, hardware RAID support is available for Intel® System Management software • Intel® Light-Guided Diagnostics on field replaceable units 4 Intel® Server Board S5000PSL Product code S5000PSLSAS and S5000PSLSASR: Intel® Embedded Server RAID Technology II...
.... Uses specially keyed PCI Express slot, add-in card slot 4. - When the optional Intel® Activation KEY AXXRAK18E and RAM are installed, hardware RAID support is available for Intel® System Management software • Intel® Light-Guided Diagnostics on field replaceable units 4 Intel® Server Board S5000PSL Product code S5000PSLSAS and S5000PSLSASR: Intel® Embedded Server RAID Technology II...
User Guide
Page 23
... NN MM LL KK JJ II HH GG FF DD BB Z X V EE CC AA Y W P Q R S T U AF000247 A. PCI-X 64-bit, 100-/133-MHz R. Processor 1 fan header JJ. DIMM sockets (see Figure 5 FF. PCI Express* x4 or x8 slot 3 S. SATA 1 Intel® Server Board S5000PSL 5 Enclosure management SAS SES2 (product codes S5000PSLSAS and S5000PSLSASR only) C. Hot-swap backplane A header...
... NN MM LL KK JJ II HH GG FF DD BB Z X V EE CC AA Y W P Q R S T U AF000247 A. PCI-X 64-bit, 100-/133-MHz R. Processor 1 fan header JJ. DIMM sockets (see Figure 5 FF. PCI Express* x4 or x8 slot 3 S. SATA 1 Intel® Server Board S5000PSL 5 Enclosure management SAS SES2 (product codes S5000PSLSAS and S5000PSLSASR only) C. Hot-swap backplane A header...
User Guide
Page 24
...or SAS 3 (SAS 3 is available only on product codes S5000PSLSAS and S5000PSLSASR) OO. Chassis intrusion header Figure 2. Server Board Connector and Component Locations 6 Intel® Server Board S5000PSL CMOS battery I /O ports (see Figure 4 on page 12) L. System fan 2 header Z. SATA 4 or... SAS 2 (SAS 2 is available only on product codes S5000PSLSAS, and S5000PSLSASR) NN. Serial B / emergency management port header TT. PCI Express x8 slot...
...or SAS 3 (SAS 3 is available only on product codes S5000PSLSAS and S5000PSLSASR) OO. Chassis intrusion header Figure 2. Server Board Connector and Component Locations 6 Intel® Server Board S5000PSL CMOS battery I /O ports (see Figure 4 on page 12) L. System fan 2 header Z. SATA 4 or... SAS 2 (SAS 2 is available only on product codes S5000PSLSAS, and S5000PSLSASR) NN. Serial B / emergency management port header TT. PCI Express x8 slot...
User Guide
Page 33
... DIMM, and an expander are installed, the Intel® Integrated Server RAID module supports up to 16 physical drives and up to 64 logical arrays when an expander is installed into a specially keyed PCI Express* x8 slot (slot 4). See the ... such as described in "SATA Server Board". ROMB Server Board The Intel® Server Board S5000PSL with Hot-swap Drive Bacplanes. Because the RAID features have firmware installed in the Software User's Guide: Intel® Embedded Server RAID Technology II, Intel® Integrated Server RAID, and Intel® RAID Controllers SRCSAS18E and ...
... DIMM, and an expander are installed, the Intel® Integrated Server RAID module supports up to 16 physical drives and up to 64 logical arrays when an expander is installed into a specially keyed PCI Express* x8 slot (slot 4). See the ... such as described in "SATA Server Board". ROMB Server Board The Intel® Server Board S5000PSL with Hot-swap Drive Bacplanes. Because the RAID features have firmware installed in the Software User's Guide: Intel® Embedded Server RAID Technology II, Intel® Integrated Server RAID, and Intel® RAID Controllers SRCSAS18E and ...
User Guide
Page 64
...and not touching any components, causing a potential short? • Are all add-in PCI boards fully seated in their slots on the server board? • Are all jumper settings on the server board correct? • Are all jumper and switch settings on page viii for example, two ...from the tested components lists? If applicable, ensure that there are no conflicts-for links to the tested component lists. 46 Intel® Server Board S5000PSL See the operating system documentation. • Did you are experiencing is a less frequent cause. Problems following Initial System Installation ...
...and not touching any components, causing a potential short? • Are all add-in PCI boards fully seated in their slots on the server board? • Are all jumper settings on the server board correct? • Are all jumper and switch settings on page viii for example, two ...from the tested components lists? If applicable, ensure that there are no conflicts-for links to the tested component lists. 46 Intel® Server Board S5000PSL See the operating system documentation. • Did you are experiencing is a less frequent cause. Problems following Initial System Installation ...
User Guide
Page 69
...PCI drivers. For these drivers, it may require interrupts that interrupts are using the correct and the current drivers. Diagnostics pass but the connection fails • Make sure the network cable is securely attached. • Make sure you are not shared. Problems with other adapter supports shared interrupts. Intel® Server Board S5000PSL... 51 Cannot Connect to a Server • Make sure the network cable is securely attached to the port from the...
...PCI drivers. For these drivers, it may require interrupts that interrupts are using the correct and the current drivers. Diagnostics pass but the connection fails • Make sure the network cable is securely attached. • Make sure you are not shared. Problems with other adapter supports shared interrupts. Intel® Server Board S5000PSL... 51 Cannot Connect to a Server • Make sure the network cable is securely attached to the port from the...
User Guide
Page 70
... requirements for the system. If the problems persist, contact the software vendor's customer service representative. 52 Intel® Server Board S5000PSL System Boots when Installing PCI Card System management features require full-time "standby" power. If you install a PCI card with the power button on the front of the system have power going to boot. Before...
... requirements for the system. If the problems persist, contact the software vendor's customer service representative. 52 Intel® Server Board S5000PSL System Boots when Installing PCI Card System management features require full-time "standby" power. If you install a PCI card with the power button on the front of the system have power going to boot. Before...