Updated S1200BTS info and BIOS setup page. Corrected typos. Intel®Server Board S1200BT TPS ii Revision 1.0 Intel order number G13326-003 Updated the hardware info and SE SKU. Updated S1200BT video mode. Revision History Revision History Date July 2010 November 2010 January 2011 January 2011 March 2011 Revision Number 0.3 0.5 0.7 0.9 1.0 Modifications Initial release.
Updated S1200BTS info and BIOS setup page. Corrected typos. Intel®Server Board S1200BT TPS ii Revision 1.0 Intel order number G13326-003 Updated the hardware info and SE SKU. Updated S1200BT video mode. Revision History Revision History Date July 2010 November 2010 January 2011 January 2011 March 2011 Revision Number 0.3 0.5 0.7 0.9 1.0 Modifications Initial release.
Product Specification
Page 7
...8.2 Integrated BMC Force Update Procedure (Only for S1200BTL 109 9.2 Post Code Diagnostic LEDs 109 10. Intel® Light Guided Diagnostics 109 9.1 System Status LED (Only for The Intel® Server Board S1200BTL) ...107 8.3 ME Force Update Jumper 107 8.4 BIOS Recovery Jumper 108 9.... Design and Environmental Specifications 111 10.1 Intel® Server Board S1200BT Design Specifications 111 10.2 Board...
...8.2 Integrated BMC Force Update Procedure (Only for S1200BTL 109 9.2 Post Code Diagnostic LEDs 109 10. Intel® Light Guided Diagnostics 109 9.1 System Status LED (Only for The Intel® Server Board S1200BTL) ...107 8.3 ME Force Update Jumper 107 8.4 BIOS Recovery Jumper 108 9.... Design and Environmental Specifications 111 10.1 Intel® Server Board S1200BT Design Specifications 111 10.2 Board...
Product Specification
Page 45
...supply redundancy monitoring and support Hot-swap fan support Acoustic management: Support for multiple fan profiles Revision 1.0 33 Intel order number G13326-003 It polls sensors to monitor and report system health. IPMI interfaces o Host interfaces include system ...Interface Specification Second Generation v2.0 for future enhancements or additions. In-circuit BMC firmware update Fault resilient booting (FRB): FRB2 is supported by the BIOS. BMC self test: The BMC performs initialization and run-time self-tests and makes...
...supply redundancy monitoring and support Hot-swap fan support Acoustic management: Support for multiple fan profiles Revision 1.0 33 Intel order number G13326-003 It polls sensors to monitor and report system health. IPMI interfaces o Host interfaces include system ...Interface Specification Second Generation v2.0 for future enhancements or additions. In-circuit BMC firmware update Fault resilient booting (FRB): FRB2 is supported by the BIOS. BMC self test: The BMC performs initialization and run-time self-tests and makes...
Product Specification
Page 49
...It is powered up, the remote KVM session displays the complete BIOS boot process. KVM sessions persist across an AC power loss. 4.2.2.5 Timeout The remote KVM session will automatically timeout after Integrated BMC firmware update) will degrade performance. Remote KVM is not deactivated by mode...'s capabilities. 4.2.2.4 Availability The remote KVM session is available even when the server is powered-off . An Integrated BMC reset (e.g. Intel®Server Board S1200BT TPS Platform Management The Remote Console window is a Java Applet that is run over IP is performed in...
...It is powered up, the remote KVM session displays the complete BIOS boot process. KVM sessions persist across an AC power loss. 4.2.2.5 Timeout The remote KVM session will automatically timeout after Integrated BMC firmware update) will degrade performance. Remote KVM is not deactivated by mode...'s capabilities. 4.2.2.4 Availability The remote KVM session is available even when the server is powered-off . An Integrated BMC reset (e.g. Intel®Server Board S1200BT TPS Platform Management The Remote Console window is a Java Applet that is run over IP is performed in...
Product Specification
Page 50
...CD-ROM, floppy drive, or a USB flash disk as a standalone applet. The media redirection feature is possible to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from the remotely mounted device and to the server. Both remote and local devices are useable in the... KVM-r to configure the OS during a server reset or power on a bare metal server (no OS present) using the remotely mounted device. Platform Management Intel®Server Board S1200BT TPS 4.2.3 Media Redirection The embedded web server provides a Java applet to the system...
...CD-ROM, floppy drive, or a USB flash disk as a standalone applet. The media redirection feature is possible to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from the remotely mounted device and to the server. Both remote and local devices are useable in the... KVM-r to configure the OS during a server reset or power on a bare metal server (no OS present) using the remotely mounted device. Platform Management Intel®Server Board S1200BT TPS 4.2.3 Media Redirection The embedded web server provides a Java applet to the system...
Product Specification
Page 54
...-Intel) and platform chassis configuration is a program used to write platform-specific configuration data to NVRAM on the server board. Otherwise, the system does not change any of the throttling control registers in the embedded memory controller during runtime. 4.3.2 Fan Speed Control BIOS ...read each time the system is run time. 4.3.2.1 System Configuration Using the FRUSDR Utility The Field Replaceable Unit and Sensor Data Record Update Utility (FRUSDR utility) is used for the platform. The following terminology is a platform resident technology that can be used . ...
...-Intel) and platform chassis configuration is a program used to write platform-specific configuration data to NVRAM on the server board. Otherwise, the system does not change any of the throttling control registers in the embedded memory controller during runtime. 4.3.2 Fan Speed Control BIOS ...read each time the system is run time. 4.3.2.1 System Configuration Using the FRUSDR Utility The Field Replaceable Unit and Sensor Data Record Update Utility (FRUSDR utility) is used for the platform. The following terminology is a platform resident technology that can be used . ...
Product Specification
Page 116
...pins should not be jumpered for normal operation. Integrated BMC Firmware Force Update Mode - Figure 46. ME Firmware Force Update Mode - Disabled (Default) ME Firmware Force Update Mode - Jumper Blocks Intel®Server Board S1200BT TPS 8. These pins should have a jumper... Board Jumpers (J1F1, J1F2, J1F3, J1E2, and J4A2) on S1200BTL Jumper Name Pins J1E2: CMOS 1-2 Clear 2-3 J1F2: ME 1-2 Force Update 2-3 J1F1: 1-2 Password Clear 2-3 J1F3: BIOS 1-2 Recovery 2-3 J4A2: BMC 1-2 Force Update 2-3 System Results These pins should not be used to configure, protect...
...pins should not be jumpered for normal operation. Integrated BMC Firmware Force Update Mode - Figure 46. ME Firmware Force Update Mode - Disabled (Default) ME Firmware Force Update Mode - Jumper Blocks Intel®Server Board S1200BT TPS 8. These pins should have a jumper... Board Jumpers (J1F1, J1F2, J1F3, J1E2, and J4A2) on S1200BTL Jumper Name Pins J1E2: CMOS 1-2 Clear 2-3 J1F2: ME 1-2 Force Update 2-3 J1F1: 1-2 Password Clear 2-3 J1F3: BIOS 1-2 Recovery 2-3 J4A2: BMC 1-2 Force Update 2-3 System Results These pins should not be used to configure, protect...
Product Specification
Page 117
...J1G1, J1H3, and J2J1) on S1200BTS Jumper Name Pins J1H3: CMOS 1-2 Clear 2-3 J1J2: ME Force 1-2 Update 2-3 J1G1: 1-2 Password Clear 2-3 J2G1: BIOS 1-2 Recovery 2-3 System Results These pins should have a jumper in place for normal system operation. (Default) ...If these pins are jumpered with minimal system downtime. ME Firmware Force Update Mode - These pins should not be jumpered for normal system operation. (Default) If these two Revision 1.0 105 Intel...
...J1G1, J1H3, and J2J1) on S1200BTS Jumper Name Pins J1H3: CMOS 1-2 Clear 2-3 J1J2: ME Force 1-2 Update 2-3 J1G1: 1-2 Password Clear 2-3 J2G1: BIOS 1-2 Recovery 2-3 System Results These pins should have a jumper in place for normal system operation. (Default) ...If these pins are jumpered with minimal system downtime. ME Firmware Force Update Mode - These pins should not be jumpered for normal system operation. (Default) If these two Revision 1.0 105 Intel...
Product Specification
Page 120
... Restore the jumper to the enabled position (covering pins 2 and 3). 4. When the flash update completes: 1. Open the server chassis. Close the server chassis. 5. Re-flash any custom blocks, such as BIOS). 7. Turn on the system power. Power down and remove the AC power cord. 8. ... AC cord and power up the server. 6. Move the BIOS recovery jumper to its original position. 4. Jumper Blocks Intel®Server Board S1200BT TPS 1. The user should now boot using the updated system BIOS. 108 Revision 1.0 Intel order number G13326-003 Turn off the system power. 2. The...
... Restore the jumper to the enabled position (covering pins 2 and 3). 4. When the flash update completes: 1. Open the server chassis. Close the server chassis. 5. Re-flash any custom blocks, such as BIOS). 7. Turn on the system power. Power down and remove the AC power cord. 8. ... AC cord and power up the server. 6. Move the BIOS recovery jumper to its original position. 4. Jumper Blocks Intel®Server Board S1200BT TPS 1. The user should now boot using the updated system BIOS. 108 Revision 1.0 Intel order number G13326-003 Turn off the system power. 2. The...
Product Specification
Page 131
...wait 30 seconds, and then reconnect the AC power cord. This jumper should only be used when the standard firmware update process fails. Intel®Server Board S1200BT TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips When adding ... BMC functionality is running normally. When performing a normal BIOS update procedure, the BIOS recovery jumper must be removed. Removing the AC power before the hang. Supports only unbuffered DDR3 DIMMs (UDIMMs). AXXRMM2) or Intel® Remote Management Module 3 (Product Order Code - Power up...
...wait 30 seconds, and then reconnect the AC power cord. This jumper should only be used when the standard firmware update process fails. Intel®Server Board S1200BT TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips When adding ... BMC functionality is running normally. When performing a normal BIOS update procedure, the BIOS recovery jumper must be removed. Removing the AC power before the hang. Supports only unbuffered DDR3 DIMMs (UDIMMs). AXXRMM2) or Intel® Remote Management Module 3 (Product Order Code - Power up...
Product Specification
Page 145
...on the data bit availability to display progress codes, a progress code can be customized to apply microcode update Response Major Major Major Major Major Major Major Major Major Revision 1.0 133 Intel order number G13326-003 The user must be coordinated with a degraded state. For example: ... CMOS/NVRAM configuration cleared Passwords cleared by the system BIOS or option ROMs. The Response section in the Error Manager. Intel®Server Board S1200BT TPS Appendix D: POST Code Errors Appendix D: POST Code Errors The BIOS outputs the current boot progress codes on the screen...
...on the data bit availability to display progress codes, a progress code can be customized to apply microcode update Response Major Major Major Major Major Major Major Major Major Revision 1.0 133 Intel order number G13326-003 The user must be coordinated with a degraded state. For example: ... CMOS/NVRAM configuration cleared Passwords cleared by the system BIOS or option ROMs. The Response section in the Error Manager. Intel®Server Board S1200BT TPS Appendix D: POST Code Errors Appendix D: POST Code Errors The BIOS outputs the current boot progress codes on the screen...
Product Specification
Page 146
...Major Major Major Major Major Fatal Fatal Fatal Minor Minor Minor Minor Major Fatal Minor Fatal 134 Revision 1.0 Intel order number G13326-003 TPM device not detected. TPM device failed self test. PCI Express component encountered a ...failure Management Engine (ME) failed Selftest Management Engine (ME) Failed to respond Baseboard management controller in update mode Sensor data record empty System event log full Memory component could not be configured in the selected... software state error. TPM device missing or not responding. BIOS ACM Error PCI component encountered a SERR error.
...Major Major Major Major Major Fatal Fatal Fatal Minor Minor Minor Minor Major Fatal Minor Fatal 134 Revision 1.0 Intel order number G13326-003 TPM device not detected. TPM device failed self test. PCI Express component encountered a ...failure Management Engine (ME) failed Selftest Management Engine (ME) Failed to respond Baseboard management controller in update mode Sensor data record empty System event log full Memory component could not be configured in the selected... software state error. TPM device missing or not responding. BIOS ACM Error PCI component encountered a SERR error.
Quick Start Guide
Page 1
...of 350 W with your chassis for preparatory steps. Copyright © 2010, Intel Corporation. G20164-002 4 Install the Server Board IMPORTANT NOTE: If you for buying the Intel® Server Board S1200BTL. Intel ® Server Chassis P4000 series Shown I /O shield and label installation ...Processor Cautions: When removing the protective cover, DO NOT TOUCH the A gold socket pins. Repeat B-D for BIOS and firmware configuration and updates. C Press downward on the locking lever. Minimum Hardware Requirements To avoid integration difficulties and possible...
...of 350 W with your chassis for preparatory steps. Copyright © 2010, Intel Corporation. G20164-002 4 Install the Server Board IMPORTANT NOTE: If you for buying the Intel® Server Board S1200BTL. Intel ® Server Chassis P4000 series Shown I /O shield and label installation ...Processor Cautions: When removing the protective cover, DO NOT TOUCH the A gold socket pins. Repeat B-D for BIOS and firmware configuration and updates. C Press downward on the locking lever. Minimum Hardware Requirements To avoid integration difficulties and possible...