User Guide
Page 1
Intel® Compute Module MFS5000SI User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D90834-005
Intel® Compute Module MFS5000SI User Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D90834-005
User Guide
Page 3
...Intel® Compute Module MFS5000SI User Guide iii See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Consultez Intel® Server Boards and Server Chassis Safety Information sur le site http://support.intel.com/support/motherboards/ server...eine der Anweisungen ausführen. Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Instrucciones de seguridad importantes Lea todas ...
...Intel® Compute Module MFS5000SI User Guide iii See also Intel® Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Consultez Intel® Server Boards and Server Chassis Safety Information sur le site http://support.intel.com/support/motherboards/ server...eine der Anweisungen ausführen. Beachten Sie hierzu auch die Intel® Server Boards and Server Chassis Safety Information unter http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm. Instrucciones de seguridad importantes Lea todas ...
User Guide
Page 4
...the jumper with the function controlled by wearing an anti-static wrist strap attached to chassis ground (any components. iv Intel® Compute Module MFS5000SI User Guide Make sure the AC power cord is sold. Warnings These warnings and cautions apply whenever you are using needle nosed ...in which the product is unplugged before opening it without the enclosure cover in place can grip with your server product, whether you remove the compute module enclosure cover to access components inside the jumper, causing intermittent problems with the pliers, never the wide ...
...the jumper with the function controlled by wearing an anti-static wrist strap attached to chassis ground (any components. iv Intel® Compute Module MFS5000SI User Guide Make sure the AC power cord is sold. Warnings These warnings and cautions apply whenever you are using needle nosed ...in which the product is unplugged before opening it without the enclosure cover in place can grip with your server product, whether you remove the compute module enclosure cover to access components inside the jumper, causing intermittent problems with the pliers, never the wide ...
User Guide
Page 5
... Needed ...7 Installation Guidelines ...7 Removing and Installing an Intel® Compute Module MFS5000SI 7 Removing a Compute Module from the Server System 7 Installing a Compute Module into the Server System 8 Opening and Closing the Top Cover 8 ...Modules 24 Supported Memory ...24 Memory Sparing and Mirroring 24 Installing DIMMs ...25 Removing DIMMs ...29 Installing and Removing Mezzanine Card 32 Installing the Mezzanine Card 32 Removing a Mezzanine Card 35 Replacing the CMOS Battery 39 Troubleshooting ...41 First Steps Checklist ...41 Intel® Compute Module MFS5000SI User Guide...
... Needed ...7 Installation Guidelines ...7 Removing and Installing an Intel® Compute Module MFS5000SI 7 Removing a Compute Module from the Server System 7 Installing a Compute Module into the Server System 8 Opening and Closing the Top Cover 8 ...Modules 24 Supported Memory ...24 Memory Sparing and Mirroring 24 Installing DIMMs ...25 Removing DIMMs ...29 Installing and Removing Mezzanine Card 32 Installing the Mezzanine Card 32 Removing a Mezzanine Card 35 Replacing the CMOS Battery 39 Troubleshooting ...41 First Steps Checklist ...41 Intel® Compute Module MFS5000SI User Guide...
User Guide
Page 6
... Magnetic Compatibility (EMC) / Harmonic Requirements 57 Product Ecology Requirements 57 Component Regulatory Requirements Needed to a Compute Module 44 Problems with Newly Installed Application Software 45 Problems with Application Software that Previously Functioned Properly 45 Devices ... ...61 Server Safety Information ...61 Safety Warnings and Cautions 61 Intended Application Uses ...62 Site Selection ...62 Equipment Handling Practices 62 Power and Electrical Warnings 62 System Access Warnings ...63 Rack Mount Warnings ...64 vi Intel® Compute Module MFS5000SI User Guide
... Magnetic Compatibility (EMC) / Harmonic Requirements 57 Product Ecology Requirements 57 Component Regulatory Requirements Needed to a Compute Module 44 Problems with Newly Installed Application Software 45 Problems with Application Software that Previously Functioned Properly 45 Devices ... ...61 Server Safety Information ...61 Safety Warnings and Cautions 61 Intended Application Uses ...62 Site Selection ...62 Equipment Handling Practices 62 Power and Electrical Warnings 62 System Access Warnings ...63 Rack Mount Warnings ...64 vi Intel® Compute Module MFS5000SI User Guide
User Guide
Page 9
List of Tables Table 1. POST Error Beep Codes 47 Intel® Compute Module MFS5000SI User Guide ix Compute Module Features 2 Table 2. Diagnostic LED Information 46 Table 3.
List of Tables Table 1. POST Error Beep Codes 47 Intel® Compute Module MFS5000SI User Guide ix Compute Module Features 2 Table 2. Diagnostic LED Information 46 Table 3.
User Guide
Page 11
...Duct 26 Figure 30. Securing Mezzanine Card to Standoffs 35 Figure 39. Removing Screws from Server Board 32 Figure 36. CMOS Battery Location 40 Intel® Compute Module MFS5000SI User Guide xi Removing Top Cover 9 Figure 7. Removing Screws from Mezzanine Card 36 Figure 40. Front... Air Duct 29 Figure 33. Installing Standoffs for Mezzanine Card 33 Figure 37. List of Figures Figure 1. Intel® Compute Module MFS5000SI 1 Figure 2. Server Board ...1 Figure 3. Lifting Processor Socket Handle 12 Figure 10. Orienting and Installing Processor 13 Figure 13. ...
...Duct 26 Figure 30. Securing Mezzanine Card to Standoffs 35 Figure 39. Removing Screws from Server Board 32 Figure 36. CMOS Battery Location 40 Intel® Compute Module MFS5000SI User Guide xi Removing Top Cover 9 Figure 7. Removing Screws from Mezzanine Card 36 Figure 40. Front... Air Duct 29 Figure 33. Installing Standoffs for Mezzanine Card 33 Figure 37. List of Figures Figure 1. Intel® Compute Module MFS5000SI 1 Figure 2. Server Board ...1 Figure 3. Lifting Processor Socket Handle 12 Figure 10. Orienting and Installing Processor 13 Figure 13. ...
User Guide
Page 13
Server Board Intel® Compute Module MFS5000SI User Guide 1 The Intel® Compute Module MFS5000SI is shown in the following pictures. Figure 1. 1 Compute Module Features This chapter briefly describes the main features of the Intel® Compute Module MFS5000SI, as well as provides illustrations showing the location of important components and connections on the compute module. Intel® Compute Module MFS5000SI Figure 2.
Server Board Intel® Compute Module MFS5000SI User Guide 1 The Intel® Compute Module MFS5000SI is shown in the following pictures. Figure 1. 1 Compute Module Features This chapter briefly describes the main features of the Intel® Compute Module MFS5000SI, as well as provides illustrations showing the location of important components and connections on the compute module. Intel® Compute Module MFS5000SI Figure 2.
User Guide
Page 14
...; Intel® 5000P Memory Controller Hub (MCH) • Intel® 6321ESB I/O Controller Hub External connections: • Two USB 2.0 ports • Video connector Internal connections: • One connector to the chassis I/O mezzanine card ATI* ES1000 controller with 16MB onboard memory LSI* 1064e SAS controller Intel® 8256EB dual port controller Trusted Platform Module, version 1.2 2 Intel® Compute Module MFS5000SI User Guide
...; Intel® 5000P Memory Controller Hub (MCH) • Intel® 6321ESB I/O Controller Hub External connections: • Two USB 2.0 ports • Video connector Internal connections: • One connector to the chassis I/O mezzanine card ATI* ES1000 controller with 16MB onboard memory LSI* 1064e SAS controller Intel® 8256EB dual port controller Trusted Platform Module, version 1.2 2 Intel® Compute Module MFS5000SI User Guide
User Guide
Page 15
... Locations Intel® Compute Module MFS5000SI User Guide 3 Connector and Component Locations S R Q P O N M B A C D E L K J I H F G AF002219 A Mezzanine Card Connector B Midplane Power Connector C Midplane Signal Connector D SAS Connector E FBDIMM Slots F CPU1 Socket G Power/Fault LEDs H Power Switch I Activity and ID LEDs J Video Connector K USB2 Port L USB1 Port M CMOS Battery N Test Connector (manufacturing only) O CPU #2 Heatsink P Intel® 6321ESB I/O Controller Hub Q Intel®...
... Locations Intel® Compute Module MFS5000SI User Guide 3 Connector and Component Locations S R Q P O N M B A C D E L K J I H F G AF002219 A Mezzanine Card Connector B Midplane Power Connector C Midplane Signal Connector D SAS Connector E FBDIMM Slots F CPU1 Socket G Power/Fault LEDs H Power Switch I Activity and ID LEDs J Video Connector K USB2 Port L USB1 Port M CMOS Battery N Test Connector (manufacturing only) O CPU #2 Heatsink P Intel® 6321ESB I/O Controller Hub Q Intel®...
User Guide
Page 16
Enabled BMC Firmware Force Update Mode - These pins should not be jumpered for normal operation. These pins should not be jumpered for normal operation. 4 Intel® Compute Module MFS5000SI User Guide Configuration Jumper Locations Jumper Name Pins What happens at system reset... Disabled (Default) These pins should have a jumper in place for normal system operation (Default) ...
Enabled BMC Firmware Force Update Mode - These pins should not be jumpered for normal operation. These pins should not be jumpered for normal operation. 4 Intel® Compute Module MFS5000SI User Guide Configuration Jumper Locations Jumper Name Pins What happens at system reset... Disabled (Default) These pins should have a jumper in place for normal system operation (Default) ...
User Guide
Page 17
... up to eight total. Memory A minimum of two fully-buffered DDR2 667 MHz DIMM(s) (FB-DIMM) should be installed in place for normal operation. Intel® Compute Module MFS5000SI User Guide 5 Additional DIMMs must meet the requirements outlined below. These pins should have a jumper in pairs, up to boot from the lower bank. Front Panel Connectors... G ID LED I Fault LED B USB2 Port D I/O 1 and I/O 2 Activity LEDs F Drive Activity LED H Power Button J Power LED Figure 5. These pins should not be forced to two Multi-Core Intel® Xeon® Processors 5xxx Series.
... up to eight total. Memory A minimum of two fully-buffered DDR2 667 MHz DIMM(s) (FB-DIMM) should be installed in place for normal operation. Intel® Compute Module MFS5000SI User Guide 5 Additional DIMMs must meet the requirements outlined below. These pins should have a jumper in pairs, up to boot from the lower bank. Front Panel Connectors... G ID LED I Fault LED B USB2 Port D I/O 1 and I/O 2 Activity LEDs F Drive Activity LED H Power Button J Power LED Figure 5. These pins should not be forced to two Multi-Core Intel® Xeon® Processors 5xxx Series.
User Guide
Page 18
Power Supply A minimum of one 1000-Watt power supply is required to 3 compute modules (in any slot) plus all other modules in the system. Three power supplies will support 4 to 6 compute modules (in any slot) plus all other modules in the system. Any additional power supplies above minimum required (based on a compute module. Two power supplies will support 1 compute module plus all other modules in the system. One power supply will support 2 to turn on configuration) provides redundancy. 6 Intel® Compute Module MFS5000SI User Guide
Power Supply A minimum of one 1000-Watt power supply is required to 3 compute modules (in any slot) plus all other modules in the system. Three power supplies will support 4 to 6 compute modules (in any slot) plus all other modules in the system. Any additional power supplies above minimum required (based on a compute module. Two power supplies will support 1 compute module plus all other modules in the system. One power supply will support 2 to turn on configuration) provides redundancy. 6 Intel® Compute Module MFS5000SI User Guide
User Guide
Page 19
... hot-swapped. If the compute module is operating, shut down the operating system and turn off the compute module. Removing and Installing an Intel® Compute Module MFS5000SI Removing a Compute Module from the chassis; Remove the compute module from the Server System 1. Observe the safety and ESD information at the beginning of this manual and in the appendices. 2. Intel® Compute Module MFS5000SI User Guide 7 See the instructions included...
... hot-swapped. If the compute module is operating, shut down the operating system and turn off the compute module. Removing and Installing an Intel® Compute Module MFS5000SI Removing a Compute Module from the chassis; Remove the compute module from the Server System 1. Observe the safety and ESD information at the beginning of this manual and in the appendices. 2. Intel® Compute Module MFS5000SI User Guide 7 See the instructions included...
User Guide
Page 20
... the two retention levers by pressing on a flat, non-conductive surface, with the cover side up. 8 Intel® Compute Module MFS5000SI User Guide Rotate the two lever handles outward and pull the compute module from the Server System" on the compute module are in the appendices 2. Installing a Compute Module into the bay within one minute; do not attempt to ensure proper system cooling.
... the two retention levers by pressing on a flat, non-conductive surface, with the cover side up. 8 Intel® Compute Module MFS5000SI User Guide Rotate the two lever handles outward and pull the compute module from the Server System" on the compute module are in the appendices 2. Installing a Compute Module into the bay within one minute; do not attempt to ensure proper system cooling.
User Guide
Page 21
Caution: Always replace the top cover before installing the compute module into a server system. B A 1 I/O 2 1 2 ID Figure 6. Press the top cover release button (see letter "A" in the following figure) and slide the top cover back, away from the compute module bezel (see letter "B"). Removing Top Cover AF002402 Intel® Compute Module MFS5000SI User Guide 9 4. Lift the top cover up and off the compute module.
Caution: Always replace the top cover before installing the compute module into a server system. B A 1 I/O 2 1 2 ID Figure 6. Press the top cover release button (see letter "A" in the following figure) and slide the top cover back, away from the compute module bezel (see letter "B"). Removing Top Cover AF002402 Intel® Compute Module MFS5000SI User Guide 9 4. Lift the top cover up and off the compute module.
User Guide
Page 22
... the top cover, check that all components are inside the compute module. Installing Top Cover AF002403 10 Intel® Compute Module MFS5000SI User Guide Place the top cover on the compute module so that no loose tools or parts are installed and seated correctly and that it engages the cover guide notches. Slide the top cover forward to the closed position...
... the top cover, check that all components are inside the compute module. Installing Top Cover AF002403 10 Intel® Compute Module MFS5000SI User Guide Place the top cover on the compute module so that no loose tools or parts are installed and seated correctly and that it engages the cover guide notches. Slide the top cover forward to the closed position...
User Guide
Page 23
.... Observe the safety and ESD information at the beginning of this manual and in a server system, see "Opening and Removing the Top Cover" on page 7 for use in the Intel® Compute Module MFS5000SI should be installed. Removing Processor Air Duct Intel® Compute Module MFS5000SI User Guide AF002404 11 Remove the top cover. Remove the processor air duct. 1 I/O 2 1 2 ID Figure...
.... Observe the safety and ESD information at the beginning of this manual and in a server system, see "Opening and Removing the Top Cover" on page 7 for use in the Intel® Compute Module MFS5000SI should be installed. Removing Processor Air Duct Intel® Compute Module MFS5000SI User Guide AF002404 11 Remove the top cover. Remove the processor air duct. 1 I/O 2 1 2 ID Figure...
User Guide
Page 24
Fully raise the socket handle. Note: Do not touch the socket pins; 5. they are very sensitive and easily damaged. Opening Load Plate TP02075 12 Intel® Compute Module MFS5000SI User Guide Open the load plate (see letter "A" in the following figure) to release it. Push the rear tab of the load plate up slightly. A B Figure 10. TP02074 Figure 9. Locate the processor socket. Lifting Processor Socket Handle 6. Push the lever handle down and away from the socket to bring the front end of the load plate with your finger tip (see letter "B").
Fully raise the socket handle. Note: Do not touch the socket pins; 5. they are very sensitive and easily damaged. Opening Load Plate TP02075 12 Intel® Compute Module MFS5000SI User Guide Open the load plate (see letter "A" in the following figure) to release it. Push the rear tab of the load plate up slightly. A B Figure 10. TP02074 Figure 9. Locate the processor socket. Lifting Processor Socket Handle 6. Push the lever handle down and away from the socket to bring the front end of the load plate with your finger tip (see letter "B").
User Guide
Page 25
... opening before installation. Processor must align correctly with the processor socket so that may damage the socket pins if installed improperly. Orienting and Installing Processor Intel® Compute Module MFS5000SI User Guide 13 Removing Protective Shipping Cover 8. DO NOT DROP processor into socket. If present, remove the protective shipping cover from the processor. Install the processor...
... opening before installation. Processor must align correctly with the processor socket so that may damage the socket pins if installed improperly. Orienting and Installing Processor Intel® Compute Module MFS5000SI User Guide 13 Removing Protective Shipping Cover 8. DO NOT DROP processor into socket. If present, remove the protective shipping cover from the processor. Install the processor...