Instruction Manual
Page 19
...6 • Audio output power is of 1.5:1 or less. VII) Connects a 50 Ω antenna with a PL-259 connector and a 50 Ω coaxial cable for data cloning. (pgs. 155, 156) 8 y POWER RECEPTACLE [DC13.8V] 9 Accepts 13.8 V DC ±15% with the cloning software CS-80/880 ...lighter socket as a 11 power source when operating in the FUNC set mode (SET). (p. 129) e DATA JACK [DATA] ±Connect a PC through the optional data communication cable OPC-1529R, for data 3 communications. w COOLING FAN Rotates while transmitting. The transceiver accepts a 50 Ω antenna and a ...
...6 • Audio output power is of 1.5:1 or less. VII) Connects a 50 Ω antenna with a PL-259 connector and a 50 Ω coaxial cable for data cloning. (pgs. 155, 156) 8 y POWER RECEPTACLE [DC13.8V] 9 Accepts 13.8 V DC ±15% with the cloning software CS-80/880 ...lighter socket as a 11 power source when operating in the FUNC set mode (SET). (p. 129) e DATA JACK [DATA] ±Connect a PC through the optional data communication cable OPC-1529R, for data 3 communications. w COOLING FAN Rotates while transmitting. The transceiver accepts a 50 Ω antenna and a ...
Instruction Manual
Page 88
... condition setting at right. Use the optional OPC-1529R DATA COMMUNICATION CABLE with the optional OPC-1529R as described in "Current call signs, etc. to [DATA] to RS-232C port OPC-1529R (optional) 70 D Low-speed data communication application setting Configure the serial data communication software as your PC using with third-party...
... condition setting at right. Use the optional OPC-1529R DATA COMMUNICATION CABLE with the optional OPC-1529R as described in "Current call signs, etc. to [DATA] to RS-232C port OPC-1529R (optional) 70 D Low-speed data communication application setting Configure the serial data communication software as your PC using with third-party...
Instruction Manual
Page 173
...OFF, then ON to another. • A optional OPC-474 CLONING CABLE is completed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 155 OTHER FUNCTIONS 13 Data cloning AT POWER ON D Cloning between transceivers The ID-880H has transceiver-to enter cloning mode (master transceiver only- power on only...'s display and the bar meter shows that data is being received from one ID-880H to exit cloning mode. • "CL END" appears automatically in the sub-transceiver's display after the cloning is required. q Connect the optional OPC-474 cloning cable to the [SP] jack of the programmed...
...OFF, then ON to another. • A optional OPC-474 CLONING CABLE is completed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 155 OTHER FUNCTIONS 13 Data cloning AT POWER ON D Cloning between transceivers The ID-880H has transceiver-to enter cloning mode (master transceiver only- power on only...'s display and the bar meter shows that data is being received from one ID-880H to exit cloning mode. • "CL END" appears automatically in the sub-transceiver's display after the cloning is required. q Connect the optional OPC-474 cloning cable to the [SP] jack of the programmed...
Instruction Manual
Page 174
...NOTE: If you want to clone by connecting the optional data communication cable (OPC-1529R) to the [DATA] jack, set "DATATX" (DV data TX) to "PTT" (p. 134). To connect the transceiver and a PC, either the optional data communication cable; Otherwise data cloning may not work properly. D Cloning error NOTE: ...DO NOT push any key on the transceiver (to be cloned) power OFF then ON again and cloning must be cloned) during cloning. OPC-1529R or cloning cable; When the display ...
...NOTE: If you want to clone by connecting the optional data communication cable (OPC-1529R) to the [DATA] jack, set "DATATX" (DV data TX) to "PTT" (p. 134). To connect the transceiver and a PC, either the optional data communication cable; Otherwise data cloning may not work properly. D Cloning error NOTE: ...DO NOT push any key on the transceiver (to be cloned) power OFF then ON again and cloning must be cloned) during cloning. OPC-1529R or cloning cable; When the display ...
Instruction Manual
Page 186
...-440: 5.0 m; 16.4 ft† OPC-647: 2.5 m; 8.2 ft† OPC-441 SPEAKER EXTENSION CABLE 5.0 m; 16.4 ft† OPC-474 CLONING CABLE Used for data cloning between transceivers. 168 OPC-478/OPC-478UC CLONING CABLE Used for mounting. †Approx. http://www.icom.co.jp/world/support/index.html HM-103/154 HAND MICROPHONE HM-133 REMOTE...
...-440: 5.0 m; 16.4 ft† OPC-647: 2.5 m; 8.2 ft† OPC-441 SPEAKER EXTENSION CABLE 5.0 m; 16.4 ft† OPC-474 CLONING CABLE Used for data cloning between transceivers. 168 OPC-478/OPC-478UC CLONING CABLE Used for mounting. †Approx. http://www.icom.co.jp/world/support/index.html HM-103/154 HAND MICROPHONE HM-133 REMOTE...
Instruction Manual
Page 192
... RPT1/RPT2 call sign programming 33 RX call sign auto write (CALL W 135 RX call sign programming 32 Saving own position data 78 Saving received position data 78 Scan edges programming 103 SCAN mode items 123 Scan name (SCAN N 132 Scan operation 100 Scan pause timer (PAUSE 109...setting (GSA 74, 139 Sentence formatter setting (GSV 74, 139 Sentence formatter setting (RMC 74, 139 Sentence formatter setting (VTG 74, 139 Separation cable connection IV Set condition guide guides 6 SET mode - FUNC items 127 SET mode - SOUNDS items 132 Setting a memory channel XI Setting DTCS ...
... RPT1/RPT2 call sign programming 33 RX call sign auto write (CALL W 135 RX call sign programming 32 Saving own position data 78 Saving received position data 78 Scan edges programming 103 SCAN mode items 123 Scan name (SCAN N 132 Scan operation 100 Scan pause timer (PAUSE 109...setting (GSA 74, 139 Sentence formatter setting (GSV 74, 139 Sentence formatter setting (RMC 74, 139 Sentence formatter setting (VTG 74, 139 Separation cable connection IV Set condition guide guides 6 SET mode - FUNC items 127 SET mode - SOUNDS items 132 Setting a memory channel XI Setting DTCS ...