Owner's Manual
Page 12
... Batttery MCR29409 Insert fresh alkaline batteries, then reinstall battery holder. AAA alkaline batteries. All settings are optional (to provide backup power) if your thermostat was wired to run on AC power when installed. TH5110D - Install fresh batteries immediately when the REPLACE BATTERY warning begins flashing. Even if the warning does not...
... Batttery MCR29409 Insert fresh alkaline batteries, then reinstall battery holder. AAA alkaline batteries. All settings are optional (to provide backup power) if your thermostat was wired to run on AC power when installed. TH5110D - Install fresh batteries immediately when the REPLACE BATTERY warning begins flashing. Even if the warning does not...
Installation Guide
Page 1
...wire zone valves (Series 20), and normally open zone valves • Heat only with fan • Cool only • 750 mV heating systems Must be installed by a trained, experienced technician Read these instructions can damage the product or cause a hazardous condition. All rights reserved. 69-1922EFS-01 Copyright © 2009 Honeywell...model number) System Types • Gas, oil, or electric heat with this product please visit http://customer.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 ® U.S. Installation Guide FocusPRO® TH5000 Series Non...
...wire zone valves (Series 20), and normally open zone valves • Heat only with fan • Cool only • 750 mV heating systems Must be installed by a trained, experienced technician Read these instructions can damage the product or cause a hazardous condition. All rights reserved. 69-1922EFS-01 Copyright © 2009 Honeywell...model number) System Types • Gas, oil, or electric heat with this product please visit http://customer.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 ® U.S. Installation Guide FocusPRO® TH5000 Series Non...
Installation Guide
Page 2
M29368 Wire hole Mounting screws Wall anchors Wallplate M29369 ! It's easier to remove wallplate from thermostat. 2. Separate wallplate from new thermostat. Drill 7/32" holes for drywall. MERCURY ...
M29368 Wire hole Mounting screws Wall anchors Wallplate M29369 ! It's easier to remove wallplate from thermostat. 2. Separate wallplate from new thermostat. Drill 7/32" holes for drywall. MERCURY ...
Installation Guide
Page 3
... Conventional Terminals: Rc 24VAC power from cooling transformer R 24VAC power from cooling transformer. For 2 transformer systems, use common wire from heating transformer W Heat relay (stage 1) W2 Heat relay (stage 2) Y Compressor contactor (stage 1) Y2 Compressor contactor (stage 2)... G Fan relay C 24VAC common. M29370 Wiring Terminal designations Shaded areas below apply only to Em. Heat C 24VAC common *Aux and E terminals combined on TH5320U only. TH5110D Rc R Y C ...
... Conventional Terminals: Rc 24VAC power from cooling transformer R 24VAC power from cooling transformer. For 2 transformer systems, use common wire from heating transformer W Heat relay (stage 1) W2 Heat relay (stage 2) Y Compressor contactor (stage 1) Y2 Compressor contactor (stage 2)... G Fan relay C 24VAC common. M29370 Wiring Terminal designations Shaded areas below apply only to Em. Heat C 24VAC common *Aux and E terminals combined on TH5320U only. TH5110D Rc R Y C ...
Installation Guide
Page 4
conventional systems Shaded areas below NOTES Wire specifications: Use 18- Heat. to Emergency Heat. [12] Install field jumper between Aux and E if there is no emergency heat relay. 4 Provide disconnect means and ... changeover valve to O or B. [8] In Installer Setup, set to 2Heat/1Cool Heat Pump. [1] Power supply. Shielded cable is set system type to Em. Connect to Honeywell zoning panels to switch the panel to 22-gauge thermostat wire. Installation Guide Wiring Wiring guide -
conventional systems Shaded areas below NOTES Wire specifications: Use 18- Heat. to Emergency Heat. [12] Install field jumper between Aux and E if there is no emergency heat relay. 4 Provide disconnect means and ... changeover valve to O or B. [8] In Installer Setup, set to 2Heat/1Cool Heat Pump. [1] Power supply. Shielded cable is set system type to Em. Connect to Honeywell zoning panels to switch the panel to 22-gauge thermostat wire. Installation Guide Wiring Wiring guide -
Installation Guide
Page 5
... of the thermostat, then push gently until the thermostat snaps in place. ENGLISH M29386 5 69-1922EFS-01 Push excess wire back into the wall opening with slots on page 4. FocusPRO® TH5000 Series Wiring Wiring guide - Thermostat mounting Align the 4 tabs on the wallplate with non-flammable insulation. Heat [11] 2H/1C Heat...
... of the thermostat, then push gently until the thermostat snaps in place. ENGLISH M29386 5 69-1922EFS-01 Push excess wire back into the wall opening with slots on page 4. FocusPRO® TH5000 Series Wiring Wiring guide - Thermostat mounting Align the 4 tabs on the wallplate with non-flammable insulation. Heat [11] 2H/1C Heat...