Installation Instructions
Page 1
...Read these instructions. 62-0273-05 After installation is suitable for instructions regarding recycling and the proper disposal of an old control. Dispose of properly. Failure to 2 Heat, 1 Cool) Manual or automatic changeover selectable Heat-Off-Cool... is complete, check out product operation as provided in the trash. TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat APPLICATION INSTALLATION INSTRUCTIONS The TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat provides electronic control of 24 Vac heating and cooling systems. See Table...
...Read these instructions. 62-0273-05 After installation is suitable for instructions regarding recycling and the proper disposal of an old control. Dispose of properly. Failure to 2 Heat, 1 Cool) Manual or automatic changeover selectable Heat-Off-Cool... is complete, check out product operation as provided in the trash. TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat APPLICATION INSTALLATION INSTRUCTIONS The TB7100A1000 MultiPRO™ Multispeed and Multipurpose Thermostat provides electronic control of 24 Vac heating and cooling systems. See Table...
Installation Instructions
Page 10
...select a particular fan mode: Auto is only available for CNV, HP, PTAC and 4 pipe fan coil (ISU 0170). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 4. Sensor/Remote program Setback/ mable) Changeover Input 0-None 1-Remote 10K Indoor 2-Remote 20K Indoor 3-Changeover 2 pipe ... 1-Enabled available for fan coil or PTAC applications. 62-0273-05 10 Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name Default Setting All Settings Notes 0300 Changeover 1 0-Manual 1-Auto Only shown if system has both heat and cool stages (ISU...
...select a particular fan mode: Auto is only available for CNV, HP, PTAC and 4 pipe fan coil (ISU 0170). TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Table 4. Sensor/Remote program Setback/ mable) Changeover Input 0-None 1-Remote 10K Indoor 2-Remote 20K Indoor 3-Changeover 2 pipe ... 1-Enabled available for fan coil or PTAC applications. 62-0273-05 10 Installer Setup Menu. (Continued) Installer Setup Number Installer Setup Name Default Setting All Settings Notes 0300 Changeover 1 0-Manual 1-Auto Only shown if system has both heat and cool stages (ISU...
Installation Instructions
Page 13
... setback the thermostat. Occupancy sensors, manual time clock inputs, and DDC night setback can provide restrictions on the auxiliary heat. OPERATION TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Fan Sequence Operations (ISU 347, 348, 349) If heat pump or conventional application modes are enabled in ISU 170, then ISU 347 is available for installer setup selection...
... setback the thermostat. Occupancy sensors, manual time clock inputs, and DDC night setback can provide restrictions on the auxiliary heat. OPERATION TB7100A1000 MULTIPRO™ MULTISPEED AND MULTIPURPOSE THERMOSTAT Fan Sequence Operations (ISU 347, 348, 349) If heat pump or conventional application modes are enabled in ISU 170, then ISU 347 is available for installer setup selection...