Installation Guide
Page 5
...; Temporal pulse output for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is a self-contained, rechargeable wireless control/communicator that features easy installation and usage. ZONES and DEVICES • Up to 24...8226; Primary Power: Ademco K10145X10 plug-in transformer, 110VAC to 84 events • Macro/ 1-button paging • RF jam detection • Remote phone control • Compatible with encrypted (high-security) devices ALARM OUTPUT • Built-in speaker provides voice annunciation of system status along with the ...
...; Temporal pulse output for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is a self-contained, rechargeable wireless control/communicator that features easy installation and usage. ZONES and DEVICES • Up to 24...8226; Primary Power: Ademco K10145X10 plug-in transformer, 110VAC to 84 events • Macro/ 1-button paging • RF jam detection • Remote phone control • Compatible with encrypted (high-security) devices ALARM OUTPUT • Built-in speaker provides voice annunciation of system status along with the ...
Installation Guide
Page 8
Make External Sounder Connections - ADEMCO WAVE2EX). The control panel supports up to terminals 9, 13, and 14, respectively. If not using these devices, they must be connected to the K10145X10 transformer, ...
Make External Sounder Connections - ADEMCO WAVE2EX). The control panel supports up to terminals 9, 13, and 14, respectively. If not using these devices, they must be connected to the K10145X10 transformer, ...
Installation Guide
Page 12
... (K10145CN in Canada) AC Transformer to 300 feet Wire Gauge #20 #18 #16 Use only the provided ADEMCO K10145X10 or K10145CN Transformer. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to fully charge. Note: Rechargeable... batteries may take up to 48-hours to stop the beeping). LYNXR-2 Series Installation and Setup Guide AC Power and Backup Battery The system is supervised for connection and for wire gauge and length. Install battery retainer. 6. After all wiring connections have been made . Do ...
... (K10145CN in Canada) AC Transformer to 300 feet Wire Gauge #20 #18 #16 Use only the provided ADEMCO K10145X10 or K10145CN Transformer. In addition, the system will beep once every 45 seconds to audibly indicate a low battery condition (press any key to fully charge. Note: Rechargeable... batteries may take up to 48-hours to stop the beeping). LYNXR-2 Series Installation and Setup Guide AC Power and Backup Battery The system is supervised for connection and for wire gauge and length. Install battery retainer. 6. After all wiring connections have been made . Do ...
Installation Guide
Page 26
...92. (2) If Option 5 is selected a 10-digit account number must be entered in Fields ✻43 or ✻44. (3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must be programmed in Field ✻40. If the Call Waiting Cancel feature is enabled, make sure to program different options... in order to allow the pulse dialer time to the central station when used . (For an explanation of these formats, see the System Communication section of the control panel with Central stations reporting. Note: PABX number and operation of this will prevent successful communication to operate....
...92. (2) If Option 5 is selected a 10-digit account number must be entered in Fields ✻43 or ✻44. (3) Option 5 or 7 (ADEMCO Contact ID® Reporting) must be programmed in Field ✻40. If the Call Waiting Cancel feature is enabled, make sure to program different options... in order to allow the pulse dialer time to the central station when used . (For an explanation of these formats, see the System Communication section of the control panel with Central stations reporting. Note: PABX number and operation of this will prevent successful communication to operate....
Installation Guide
Page 30
...be entered if reporting formats other than Contact ID ® are always enabled. If the system is disarmed (or timeout occurs). The keypad will display "EA (EXIT ALARM)," and the alarm sounding will contain the zone number and error code 374 (Trouble-Exit Error). If Contact ID® ... Setup Guide Data Field Descriptions With an Expanded or 4+2 Format: Enter codes in this field. If the system is disarmed (or timeout occurs). If the selection is manually bypassed. - 30 - With ADEMCO Contact ID® Reporting: Enter a digit in this field will be sent when a zone is not...
...be entered if reporting formats other than Contact ID ® are always enabled. If the system is disarmed (or timeout occurs). The keypad will display "EA (EXIT ALARM)," and the alarm sounding will contain the zone number and error code 374 (Trouble-Exit Error). If Contact ID® ... Setup Guide Data Field Descriptions With an Expanded or 4+2 Format: Enter codes in this field. If the system is disarmed (or timeout occurs). If the selection is manually bypassed. - 30 - With ADEMCO Contact ID® Reporting: Enter a digit in this field will be sent when a zone is not...
Installation Guide
Page 53
... (depending on the call . Site-Initiated Remote Programming: The installer or subscriber initiates the call the subscriber, make connection, and download all security system functions (for nonpayment for Windows (at times of the call back number. Flexible Callback: If enabled in an owned... from your office to the Internet, as follows: • Arm the system in communication with 4 position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24 Plus FAX96, or an Ademco CIA Modem or via the phone lines using Remote Programming, the LYNXR-2 ...
... (depending on the call . Site-Initiated Remote Programming: The installer or subscriber initiates the call the subscriber, make connection, and download all security system functions (for nonpayment for Windows (at times of the call back number. Flexible Callback: If enabled in an owned... from your office to the Internet, as follows: • Arm the system in communication with 4 position DIP switch] internal style), a HAYES brand Optima 336 external, a HAYES brand Optima 24 Plus FAX96, or an Ademco CIA Modem or via the phone lines using Remote Programming, the LYNXR-2 ...
Installation Guide
Page 62
...cps) DTMF (10 cps) 1400Hz 1400Hz Under 3 seconds Under 3 seconds Report Code Formats 3+1 and 4+1 Standard Formats 3+1 and 4+1 Expanded Formats 4+2 Format ADEMCO Contact ID® Reporting Format Comprise a 3- (or 4-) digit subscriber number and a single digit report code (e.g. Comprise a 3- (or 4-) digit subscriber...subscriber number, 1-digit event qualifier ("new" or "restore"), 3-digit event code, and 3-digit zone number, user number, or system status number (see the following chart defines the (handshake/kissoff) frequencies that the panel supports, and the different formats that the ...
...cps) DTMF (10 cps) 1400Hz 1400Hz Under 3 seconds Under 3 seconds Report Code Formats 3+1 and 4+1 Standard Formats 3+1 and 4+1 Expanded Formats 4+2 Format ADEMCO Contact ID® Reporting Format Comprise a 3- (or 4-) digit subscriber number and a single digit report code (e.g. Comprise a 3- (or 4-) digit subscriber...subscriber number, 1-digit event qualifier ("new" or "restore"), 3-digit event code, and 3-digit zone number, user number, or system status number (see the following chart defines the (handshake/kissoff) frequencies that the panel supports, and the different formats that the ...
Installation Guide
Page 64
...is sent after two CODE + OFF (only if physically restored) - 64 - System status messages (AC Loss, Walk Test, etc.) contain zeroes in the event log upon occurrence, but are not reported: 305 = System Reset 627 = Keypad Program Mode Entry (2) LRR/IP Communications Module Low Battery ...and Low Battery restore reports are sent real time. LYNXR-2 Series Installation and Setup Guide System Communication ADEMCO Contact ID...
...is sent after two CODE + OFF (only if physically restored) - 64 - System status messages (AC Loss, Walk Test, etc.) contain zeroes in the event log upon occurrence, but are not reported: 305 = System Reset 627 = Keypad Program Mode Entry (2) LRR/IP Communications Module Low Battery ...and Low Battery restore reports are sent real time. LYNXR-2 Series Installation and Setup Guide System Communication ADEMCO Contact ID...
Installation Guide
Page 83
...Ademco express 26, 86 Ademco low speed 26, 86 Alarm bell timeout 68, 70 Alarm output 5 Alarm restore codes 68, 70 Alarm sounder 86 Alarmnet radio and internet communication devices..........9 Arm away/stay report code 68, 70 Arm-away 20 Armed system test 61 Arm-stay 20 Assign (or change) a secondary security..., 52 D Data encryption 53 Data field 17 Daylight savings time start/end 68, 70 Default master code 69, 71 Delete a secondary security code 55 Delete zone parameters confirmation 38, 39, 40 Desktop mounting 6 Dip switches 14 Disable local sounder 8 Disarm 20, 60 Download ...
...Ademco express 26, 86 Ademco low speed 26, 86 Alarm bell timeout 68, 70 Alarm output 5 Alarm restore codes 68, 70 Alarm sounder 86 Alarmnet radio and internet communication devices..........9 Arm away/stay report code 68, 70 Arm-away 20 Armed system test 61 Arm-stay 20 Assign (or change) a secondary security..., 52 D Data encryption 53 Data field 17 Daylight savings time start/end 68, 70 Default master code 69, 71 Delete a secondary security code 55 Delete zone parameters confirmation 38, 39, 40 Desktop mounting 6 Dip switches 14 Disable local sounder 8 Disarm 20, 60 Download ...
Installation Guide
Page 86
... Equivalence: 0.6B FCC Registration No.: 5GBUSA-25623-AL-E - 86 - LYNXR-2 Series Installation and Setup Guide Specifications LYNXR-2 Series Security Controls 1. Radionics/SESCOA, 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Electrical: VOLTAGE INPUT: 9VAC from plug-in 25VA transformer. ADEMCO Low Speed, 10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.
... Equivalence: 0.6B FCC Registration No.: 5GBUSA-25623-AL-E - 86 - LYNXR-2 Series Installation and Setup Guide Specifications LYNXR-2 Series Security Controls 1. Radionics/SESCOA, 20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Electrical: VOLTAGE INPUT: 9VAC from plug-in 25VA transformer. ADEMCO Low Speed, 10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.