HP t5400 Thin Clients Hardware Reference Guide
Page 29
...176; C per hour or 36° F per minute) 10,000 ft 30,000 ft Power Supply Operating Voltage Range Rated Line Frequency 100-240 VAC 50-60 Hz 100-240 VAC 50-60 Hz Power Output (maximum) 65 W 65 W ENWW 23 allowed rate of change is 457 m per minute...hour or 18° F per minute) Nonoperating 9144 m (max. allowed rate of 3 Km (10,000 ft), with no direct, sustained sunlight. A Specifications Table A-1 HP t5400 Thin Clients Dimensions Width Height (without stand) Height (with altitude derating of change is 38.7° C or 101.6° F) 10-90% 5-95% 10-90% 5-95% Maximum ...
...176; C per hour or 36° F per minute) 10,000 ft 30,000 ft Power Supply Operating Voltage Range Rated Line Frequency 100-240 VAC 50-60 Hz 100-240 VAC 50-60 Hz Power Output (maximum) 65 W 65 W ENWW 23 allowed rate of change is 457 m per minute...hour or 18° F per minute) Nonoperating 9144 m (max. allowed rate of 3 Km (10,000 ft), with no direct, sustained sunlight. A Specifications Table A-1 HP t5400 Thin Clients Dimensions Width Height (without stand) Height (with altitude derating of change is 38.7° C or 101.6° F) 10-90% 5-95% 10-90% 5-95% Maximum ...
HP t5400 Thin Clients Hardware Reference Guide
Page 44
...specifications 23 B battery, replacing 12 C cable lock, installing 25 cable routing slot 3 cautions HP Quick Release 28 mounting thin client 31 static electricity 9 thin client orientation 33, 35 ventilation 35 components front panel 2 keyboard 6 mouse 7 rear panel 3 ...thin client 26 mouse functions 7 N non-supported orientations in a drawer 35 under a monitor 35 O options installing 9 supported 9 orientation horizontal 3 vertical 4 P parallel connector 3 power button location 2 power connector location 3 power LED location 2 power output specifications 23 power supply specifications 23 powered...
...specifications 23 B battery, replacing 12 C cable lock, installing 25 cable routing slot 3 cautions HP Quick Release 28 mounting thin client 31 static electricity 9 thin client orientation 33, 35 ventilation 35 components front panel 2 keyboard 6 mouse 7 rear panel 3 ...thin client 26 mouse functions 7 N non-supported orientations in a drawer 35 under a monitor 35 O options installing 9 supported 9 orientation horizontal 3 vertical 4 P parallel connector 3 power button location 2 power connector location 3 power LED location 2 power output specifications 23 power supply specifications 23 powered...
HP t5400 Thin Clients Hardware Reference Guide
Page 45
...shipping preparation 37 shutting down 9 side access panel replacing 11 specifications altitude 23 dimensions 23 hardware 23 humidity 23 power output 23 power supply 23 rated output current 24 relative humidity 23 temperature 23 thin client 23 weight 23 stand installing 4 removing 5 supported mounting options 28 supported orientations horizontal 33 under monitor stand 33..., installing 1 USB drive options 13 USB ports location 2, 3 V vertical orientation 4, 33 VESA mounting holes 3 VGA connector location 3 W warnings electric shock fire 9 Web sites HP 1 options 1 9, 10, 12, 14 ENWW Index 39
...shipping preparation 37 shutting down 9 side access panel replacing 11 specifications altitude 23 dimensions 23 hardware 23 humidity 23 power output 23 power supply 23 rated output current 24 relative humidity 23 temperature 23 thin client 23 weight 23 stand installing 4 removing 5 supported mounting options 28 supported orientations horizontal 33 under monitor stand 33..., installing 1 USB drive options 13 USB ports location 2, 3 V vertical orientation 4, 33 VESA mounting holes 3 VGA connector location 3 W warnings electric shock fire 9 Web sites HP 1 options 1 9, 10, 12, 14 ENWW Index 39
Troubleshooting Guide: HP t5400 Thin Client
Page 39
...unit is working. Verify that the network is operating and the network cable is working power supply cable and testing it. 4. No link or activity on the top, rear panel of the thin client. client unit. (The network LEDs are located inside the RJ-45 connector on the network ... not light and you know the power supply is good, then re-image the unit. 5. Indicator lights are securely plugged into the thin client unit: ● Power connector ● Keyboard ● Mouse ● Network RJ-45 connector ● Monitor The thin client unit does not power on. 1. If network LEDs still...
...unit is working. Verify that the network is operating and the network cable is working power supply cable and testing it. 4. No link or activity on the top, rear panel of the thin client. client unit. (The network LEDs are located inside the RJ-45 connector on the network ... not light and you know the power supply is good, then re-image the unit. 5. Indicator lights are securely plugged into the thin client unit: ● Power connector ● Keyboard ● Mouse ● Network RJ-45 connector ● Monitor The thin client unit does not power on. 1. If network LEDs still...
Troubleshooting Guide: HP t5400 Thin Client
Page 49
...Video Part 2 continued No Video Part 3 Turn off . Caution: Power is continuous to the system board and power supply even when the power switch is turned off power, disconnect power cord, and open the computer. Replace cover and power cord, then restart computer. Replace components in system one at a time... then clear CMOS by removing and replacing the battery. Video OK, computer starts? Go to the unit, disconnect the power cord from the power source or the unit before beginning disassembly procedures. To prevent damage to next page t5000 Troubleshooting Flow Chart No Video, ...
...Video Part 2 continued No Video Part 3 Turn off . Caution: Power is continuous to the system board and power supply even when the power switch is turned off power, disconnect power cord, and open the computer. Replace cover and power cord, then restart computer. Replace components in system one at a time... then clear CMOS by removing and replacing the battery. Video OK, computer starts? Go to the unit, disconnect the power cord from the power source or the unit before beginning disassembly procedures. To prevent damage to next page t5000 Troubleshooting Flow Chart No Video, ...
Troubleshooting Guide: HP t5400 Thin Client
Page 50
No Video, Part 4 No Video Part 3 continued No Video Part 4 Restart computer Caution: Power is continuous to the unit, disconnect the power cord from the power source or the unit before beginning disassembly procedures. Yes Turn off . Yes Have the unit serviced. Note: Refer to the Warranty ... for coverage information. 42 Chapter 4 Diagnostics and Troubleshooting See codes No or beeps? To prevent damage to the system board and power supply even when the power switch is turned off the computer and disconnect power. Replace components in system one at a time starting with Flash.
No Video, Part 4 No Video Part 3 continued No Video Part 4 Restart computer Caution: Power is continuous to the unit, disconnect the power cord from the power source or the unit before beginning disassembly procedures. Yes Turn off . Yes Have the unit serviced. Note: Refer to the Warranty ... for coverage information. 42 Chapter 4 Diagnostics and Troubleshooting See codes No or beeps? To prevent damage to the system board and power supply even when the power switch is turned off the computer and disconnect power. Replace components in system one at a time starting with Flash.
Troubleshooting Guide: HP t5400 Thin Client
Page 51
...keyboards, not USB. Ensure the monitor is plugged in. ROM failure. Troubleshooting 43 To prevent damage to the system board and power supply even when the power switch is turned off . Video controller not present or incorrectly initialized. Error Messages Error Messages Beeps, CPU or Keyboard Lights, ...or POST error messages Caution: Power is continuous to the unit, disconnect the power cord from the HP Web site at: http://www.hp.com/products Notes: Short (S) and long (L) beeps will only function on . Power LED glows green. LEDs will only be heard if ...
...keyboards, not USB. Ensure the monitor is plugged in. ROM failure. Troubleshooting 43 To prevent damage to the system board and power supply even when the power switch is turned off . Video controller not present or incorrectly initialized. Error Messages Error Messages Beeps, CPU or Keyboard Lights, ...or POST error messages Caution: Power is continuous to the unit, disconnect the power cord from the HP Web site at: http://www.hp.com/products Notes: Short (S) and long (L) beeps will only function on . Power LED glows green. LEDs will only be heard if ...
Troubleshooting Guide: HP t5400 Thin Client
Page 74
Table F-1 HP t5400 Thin Clients (continued) Power Supply Operating Voltage Range Rated Line Frequency Power Output (maximum) Rated Output Current (maximum) Output Voltage 100-240 VAC 50-60 Hz 65 W 3.42 A +19 V DC 100-240 VAC 50-60 Hz 65 W 3.42 A +19 V DC 66 Appendix F Specifications
Table F-1 HP t5400 Thin Clients (continued) Power Supply Operating Voltage Range Rated Line Frequency Power Output (maximum) Rated Output Current (maximum) Output Voltage 100-240 VAC 50-60 Hz 65 W 3.42 A +19 V DC 100-240 VAC 50-60 Hz 65 W 3.42 A +19 V DC 66 Appendix F Specifications
Troubleshooting Guide: HP t5400 Thin Client
Page 75
... systems 1 options installing 8 supported 8 orientation horizontal 5 vertical 6 P parallel connector 4 POST error messages 29 power and IDE flash activity LEDs 27 power button location 3 power connector location 4 power LED location 3 power output specifications 66 power supply specifications 66 power-on diagnostic tests 28 power-on sequence 28 powered serial ports locations 12 system board jumpers 12 preventing electrostatic damage 64 product...
... systems 1 options installing 8 supported 8 orientation horizontal 5 vertical 6 P parallel connector 4 POST error messages 29 power and IDE flash activity LEDs 27 power button location 3 power connector location 4 power LED location 3 power output specifications 66 power supply specifications 66 power-on diagnostic tests 28 power-on sequence 28 powered serial ports locations 12 system board jumpers 12 preventing electrostatic damage 64 product...
Troubleshooting Guide: HP t5400 Thin Client
Page 76
... Task Actions 26 shutting down 8 side access panel replacing 10 specifications altitude 65 dimensions 65 hardware 65 humidity 65 power output 66 power supply 66 rated output current 66 relative humidity 65 temperature 65 thin client 65 weight 65 stand installing 6 removing 7 troubleshooting 31 U updating a BIOS 62 USB drive options 11 USB ports location 3, 4 V vertical...
... Task Actions 26 shutting down 8 side access panel replacing 10 specifications altitude 65 dimensions 65 hardware 65 humidity 65 power output 66 power supply 66 rated output current 66 relative humidity 65 temperature 65 thin client 65 weight 65 stand installing 6 removing 7 troubleshooting 31 U updating a BIOS 62 USB drive options 11 USB ports location 3, 4 V vertical...