...Warranty See the Customer Support/Warranty booklet included with Gigabit Uplink (J8762A) ProCurve 600 Redundant and External Power Supply (J8168A) ProCurve 610 External Power Supply (J8169A) ProCurve Switch 2626 (J4900B) ProCurve Switch 2650 (J4899B) Trademark Credits Windows® is subject to your HewlettPackard...herein should be photocopied, reproduced, or translation into another language without notice. Hewlett-Packard assumes no responsibility for HP products and services are set forth in connection with the furnishing, performance, or use or reliability of this ...
...Warranty See the Customer Support/Warranty booklet included with Gigabit Uplink (J8762A) ProCurve 600 Redundant and External Power Supply (J8168A) ProCurve 610 External Power Supply (J8169A) ProCurve Switch 2626 (J4900B) ProCurve Switch 2650 (J4899B) Trademark Credits Windows® is subject to your HewlettPackard...herein should be photocopied, reproduced, or translation into another language without notice. Hewlett-Packard assumes no responsibility for HP products and services are set forth in connection with the furnishing, performance, or use or reliability of this ...
User Manual
Page 9
...Switches also support Redundant Power Supply and Power over Ethernet (PoE) technologies. Use only one (T or M) for each Gigabit port Power Fault hp procurve switch 2626-PWR J8164A PoE Status RPS Act EPS LED Mode FDx Fan Spd Test PoE Reset Clear Spd mode: off = 10 Mbps, flash = ... 13 23 Gig-T Ports 25 M 26 M 12 14 (all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are IEEE Auto MDI/MDI-X) 48 ! ProCurve Switch 2650 (J4899B) ProCurve Switch 2626 (J4900B) ProCurve Switch 2650-PWR (J8165A) hp procurve 1 3 5 7 9 11 13 15 17 19 21 23 Link|Mode 25 27 29...
...Switches also support Redundant Power Supply and Power over Ethernet (PoE) technologies. Use only one (T or M) for each Gigabit port Power Fault hp procurve switch 2626-PWR J8164A PoE Status RPS Act EPS LED Mode FDx Fan Spd Test PoE Reset Clear Spd mode: off = 10 Mbps, flash = ... 13 23 Gig-T Ports 25 M 26 M 12 14 (all 10/100Base-TX ports are HP Auto-MDIX, Gig-T ports are IEEE Auto MDI/MDI-X) 48 ! ProCurve Switch 2650 (J4899B) ProCurve Switch 2626 (J4900B) ProCurve Switch 2650-PWR (J8165A) hp procurve 1 3 5 7 9 11 13 15 17 19 21 23 Link|Mode 25 27 29...
User Manual
Page 10
...AC power supply fail. All of the Switch 2600-PWR ports can be connected to a ProCurve 600 Redundant and External Power Supply (J8168A), hereafter referred to as the 600 RPS/ EPS or a ProCurve 610 External Power Supply, hereafter referred to modify the existing Ethernet infrastructure. The Series 2600PWR Switches...Switch 2650 and 2650-PWR, has 48 auto-sensing 10/100Base-TX RJ45 ports with two dual-personality Gigabit Uplink ports. ■ The Switch 2626 and 2626-PWR, has 24 auto-sensing 10/100Base-TX RJ45 ports with two dual-personality Gigabit Uplink ports. ■ The Switch 2600-8-PWR, has ...
...AC power supply fail. All of the Switch 2600-PWR ports can be connected to a ProCurve 600 Redundant and External Power Supply (J8168A), hereafter referred to as the 600 RPS/ EPS or a ProCurve 610 External Power Supply, hereafter referred to modify the existing Ethernet infrastructure. The Series 2600PWR Switches...Switch 2650 and 2650-PWR, has 48 auto-sensing 10/100Base-TX RJ45 ports with two dual-personality Gigabit Uplink ports. ■ The Switch 2626 and 2626-PWR, has 24 auto-sensing 10/100Base-TX RJ45 ports with two dual-personality Gigabit Uplink ports. ■ The Switch 2600-8-PWR, has ...
User Manual
Page 14
...-personality port have Link and Mode LEDs. overlaid with a slow blink rate on the Port LED View selected. Port LEDs Switch LEDs State Meaning Switch 2626 and Switch 2650 Port LEDs (green - The switch Fault, and Self Test LEDs will blink with the port number) Displays port link information, network activity... active network cable is not receiving link beat or sufficient light • the port has been disabled through the switch console, the web browser interface, ProCurve Manager, or other network management tool. Table 1-2.
...-personality port have Link and Mode LEDs. overlaid with a slow blink rate on the Port LED View selected. Port LEDs Switch LEDs State Meaning Switch 2626 and Switch 2650 Port LEDs (green - The switch Fault, and Self Test LEDs will blink with the port number) Displays port link information, network activity... active network cable is not receiving link beat or sufficient light • the port has been disabled through the switch console, the web browser interface, ProCurve Manager, or other network management tool. Table 1-2.
User Manual
Page 15
For the non-PWR switches, there is a single LED per port. Switch 2626 and Switch 2650 Port LED (one for each port) Port LED View select button and indicator LEDs For the PWR switches, there are embedded in ... step from one view mode to the next. The operation of the switch ports in the port connector. Switch 2626-PWR and 2650-PWR Link LED (port number) Mode LED Power Fault hp procurve 1 3 5 7 switch 2650-PWR 2 1 4 6 8 J8165A PoE Status RPS Act EPS LED Mode FDx Fan Spd Test PoE Reset Clear 2 Spd...
For the non-PWR switches, there is a single LED per port. Switch 2626 and Switch 2650 Port LED (one for each port) Port LED View select button and indicator LEDs For the PWR switches, there are embedded in ... step from one view mode to the next. The operation of the switch ports in the port connector. Switch 2626-PWR and 2650-PWR Link LED (port number) Mode LED Power Fault hp procurve 1 3 5 7 switch 2650-PWR 2 1 4 6 8 J8165A PoE Status RPS Act EPS LED Mode FDx Fan Spd Test PoE Reset Clear 2 Spd...
User Manual
Page 18
... this is not obstructed for proper switch operation ProCurve Switch 2626-PWR and 2650-PWR Console EPS Input HP ProCurve RPS Input 12V 7.5A Console Port EPS Input RPS Input EPS Redundant Input EPS Input Line 50/60 Hz. 100-240 V~ 7.5 A AC power connector ProCurve Switch 2600-8-PWR ProCurve RPS Input Multiple power sources. make sure...
... this is not obstructed for proper switch operation ProCurve Switch 2626-PWR and 2650-PWR Console EPS Input HP ProCurve RPS Input 12V 7.5A Console Port EPS Input RPS Input EPS Redundant Input EPS Input Line 50/60 Hz. 100-240 V~ 7.5 A AC power connector ProCurve Switch 2600-8-PWR ProCurve RPS Input Multiple power sources. make sure...
User Manual
Page 21
...a standard 19-inch telco rack, in a variety of the 2626PWR and 2650-PWR products. 2-1 Installing the Switch 2 Installing the Switch The ProCurve Series 2600 Switches come with an accessory kit that can be attached so the switch can be securely located on a wall. CD ROM and booklet... ■ Console cable ■ Customer Support/Warranty booklet ■ Accessory kits Switches 2626 and 2650 Non-PWR Switches 2626-PWR and and Switch 2600-8-PWR 2650-PWR Kit number 5069-6535 Contains: • two mounting brackets • eight 8-mm M4...
...a standard 19-inch telco rack, in a variety of the 2626PWR and 2650-PWR products. 2-1 Installing the Switch 2 Installing the Switch The ProCurve Series 2600 Switches come with an accessory kit that can be attached so the switch can be securely located on a wall. CD ROM and booklet... ■ Console cable ■ Customer Support/Warranty booklet ■ Accessory kits Switches 2626 and 2650 Non-PWR Switches 2626-PWR and and Switch 2600-8-PWR 2650-PWR Kit number 5069-6535 Contains: • two mounting brackets • eight 8-mm M4...
User Manual
Page 24
...and/or falling over. If the PWR device's supplied power cord does not fit, contact HP. ■ When installing the switch, the AC outlet should be near the switch and should... with the fan vents) facing either downward or upward. ■ Do not wall mount the 2626-PWR or the 2650-PWR switches. The mark is your installation requires a different power cord than...temperature inside the rack near the AC power connectors. ■ Do not install the switch in your ProCurve Series 2600 Switches. Maximum ampere ratings are properly grounded, then use a power cord displaying the mark ...
...and/or falling over. If the PWR device's supplied power cord does not fit, contact HP. ■ When installing the switch, the AC outlet should be near the switch and should... with the fan vents) facing either downward or upward. ■ Do not wall mount the 2626-PWR or the 2650-PWR switches. The mark is your installation requires a different power cord than...temperature inside the rack near the AC power connectors. ■ Do not install the switch in your ProCurve Series 2600 Switches. Maximum ampere ratings are properly grounded, then use a power cord displaying the mark ...
User Manual
Page 29
... for the switch's current requirements. They are no voltage range settings required. If the PWR device's supplied power cord does not fit, contact HP. 2-9 The switch automatically adjusts to the power connector The Series 2600 Switches do not have a power switch. If your country. For safety,... power cord is working properly by plugging it into a properly grounded electrical outlet. 2626 and 2650 non-PWR switches Console Connect power cord to the power connector 2626 PWR and 2650 PWR switches Console EPS Input HP ProCurve RPS Input 12V 7.5A Line 50/60 Hz. 100-240 V~ 7.5 A Connect...
... for the switch's current requirements. They are no voltage range settings required. If the PWR device's supplied power cord does not fit, contact HP. 2-9 The switch automatically adjusts to the power connector The Series 2600 Switches do not have a power switch. If your country. For safety,... power cord is working properly by plugging it into a properly grounded electrical outlet. 2626 and 2650 non-PWR switches Console Connect power cord to the power connector 2626 PWR and 2650 PWR switches Console EPS Input HP ProCurve RPS Input 12V 7.5A Line 50/60 Hz. 100-240 V~ 7.5 A Connect...
User Manual
Page 102
Safety and EMC Regulatory Statements C-10 products only. J4900A, J4900B Accessories: J4858A, J4859A, J4860A Regulatory Model Number: RSVLC-0204 conforms to ISO/IEC Guide 22 and EN45014 Manufacturer's Name: Hewlett-Packard Company Manufacturer's Address: 8000 ... Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. declares that the product: Product Name: HP ProCurve Switch 2650, HP ProCurve Switch 2626 Model Numbers: J4899A, J4899B;
Safety and EMC Regulatory Statements C-10 products only. J4900A, J4900B Accessories: J4858A, J4859A, J4860A Regulatory Model Number: RSVLC-0204 conforms to ISO/IEC Guide 22 and EN45014 Manufacturer's Name: Hewlett-Packard Company Manufacturer's Address: 8000 ... Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. declares that the product: Product Name: HP ProCurve Switch 2650, HP ProCurve Switch 2626 Model Numbers: J4899A, J4899B;
User Manual
Page 103
...Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. 1) J8169A for use with ProCurve Switch 2626-PWR, 2650-PWR, and RSVLC-0302 Tested with Hewlett-Packard Co. Roseville, July 28, 2005 Mike Avery, Regulatory Engineering...GmbH, Department TRE, Herrenberger Strasse 140, D-71034 Böblingen (FAX:+49-7031-14-3143). declares that the product: Product Name: ProCurve Switch 2626-PWR ProCurve Switch 2650-PWR ProCurve Switch 2600-8-PWR Model Number: J8164A, J8165A, J8762A, J8169A1 Accessories: J4858A, J4859A, J4860A, J8168A. Harmonics EN 61000-3-3 +A1 ...
...Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE marking accordingly. 1) J8169A for use with ProCurve Switch 2626-PWR, 2650-PWR, and RSVLC-0302 Tested with Hewlett-Packard Co. Roseville, July 28, 2005 Mike Avery, Regulatory Engineering...GmbH, Department TRE, Herrenberger Strasse 140, D-71034 Böblingen (FAX:+49-7031-14-3143). declares that the product: Product Name: ProCurve Switch 2626-PWR ProCurve Switch 2650-PWR ProCurve Switch 2600-8-PWR Model Number: J8164A, J8165A, J8762A, J8169A1 Accessories: J4858A, J4859A, J4860A, J8168A. Harmonics EN 61000-3-3 +A1 ...