Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 4
...DiskSuite ...34 Unmirroring disks with DiskSuite ...36 Troubleshooting ...38 Known issues...38 Write cache not flushed on shutdown...38 Solaris stops responding on HP ProLiant DL580 G5 server 38 RAID mode not supported ...39 Kernel Panic after disabling PCI devices in RBSU 39 Network configuration fails during interactive installation 39 iLO... to boot 47 Installation succeeds but no network availability after reboot 47 Additional documentation ...48 Where to go for additional help ...48 HP documentation ...48 Free Software Foundation documentation 48 Intel documentation ...48 Contents 4
...DiskSuite ...34 Unmirroring disks with DiskSuite ...36 Troubleshooting ...38 Known issues...38 Write cache not flushed on shutdown...38 Solaris stops responding on HP ProLiant DL580 G5 server 38 RAID mode not supported ...39 Kernel Panic after disabling PCI devices in RBSU 39 Network configuration fails during interactive installation 39 iLO... to boot 47 Installation succeeds but no network availability after reboot 47 Additional documentation ...48 Where to go for additional help ...48 HP documentation ...48 Free Software Foundation documentation 48 Intel documentation ...48 Contents 4
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 6
... Applicable HP ProLiant servers BL20p G4 BL25p BL25p G2 BL260c G5 BL2x220c G5 BL35p BL45p BL45p G2 BL460c BL460c G6 BL465c BL480c BL490c G6 BL680c G5 BL685c BL685c G5 DL385 G6 DL140 G2 DL145 DL145 G2 DL160 G5 DL165 G5 DL180 G5 DL185 G5 DL360 G4p SCSI DL360 G5 DL360 G6 DL365 DL365 G5 DL370 G6 DL380 G4 DL380 G5 DL380 G6... DL585 G6 DL385 DL385 G2 DL385 G5 DL385 G5p DL580 G3 DL580 G4 DL580 G5 DL585 DL585 G2 DL585 G5 DL785 G5 ML370 G4 ML370 G5 ML370 G6 ML570 G3 ...
... Applicable HP ProLiant servers BL20p G4 BL25p BL25p G2 BL260c G5 BL2x220c G5 BL35p BL45p BL45p G2 BL460c BL460c G6 BL465c BL480c BL490c G6 BL680c G5 BL685c BL685c G5 DL385 G6 DL140 G2 DL145 DL145 G2 DL160 G5 DL165 G5 DL180 G5 DL185 G5 DL360 G4p SCSI DL360 G5 DL360 G6 DL365 DL365 G5 DL370 G6 DL380 G4 DL380 G5 DL380 G6... DL585 G6 DL385 DL385 G2 DL385 G5 DL385 G5p DL580 G3 DL580 G4 DL580 G5 DL585 DL585 G2 DL585 G5 DL785 G5 ML370 G4 ML370 G5 ML370 G6 ML570 G3 ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 38
... command before every shutdown: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will respond poorly if a PCI-Express Controller is configured in Array Accelerator For more Troubleshooting 38 As ... is properly flushed prior to disk on a DL580 G5 server. • OS releases affected-Solaris 10 8/07, 5/08 • Hardware affected-HP ProLiant DL580 G5 • Description-Solaris may be displayed on a ProLiant server running Sun Solaris 10 and configured with a ...
... command before every shutdown: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will respond poorly if a PCI-Express Controller is configured in Array Accelerator For more Troubleshooting 38 As ... is properly flushed prior to disk on a DL580 G5 server. • OS releases affected-Solaris 10 8/07, 5/08 • Hardware affected-HP ProLiant DL580 G5 • Description-Solaris may be displayed on a ProLiant server running Sun Solaris 10 and configured with a ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 39
... network configuration or Solaris is unable to configure network interfaces after rebooting. Troubleshooting 39 HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on HP ProLiant when the SATA controller is fixed with network setup at installation time, and the installation...10 1/06, 6/06, 11/06, and 5/08 • Servers affected-All supported ProLiant servers • Description-There is a known issue with Solaris 10 10/08. Add-on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is complete and the system has ...
... network configuration or Solaris is unable to configure network interfaces after rebooting. Troubleshooting 39 HP ProLiant BL260c G5, BL280c G6 • Description-Cannot install SUN Solaris 10 operating system on HP ProLiant when the SATA controller is fixed with network setup at installation time, and the installation...10 1/06, 6/06, 11/06, and 5/08 • Servers affected-All supported ProLiant servers • Description-There is a known issue with Solaris 10 10/08. Add-on an HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is complete and the system has ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 41
... to attach Broadcom gigabit Ethernet NIC fails to attach. • OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach on Solaris10 8/07, Solaris 10...
... to attach Broadcom gigabit Ethernet NIC fails to attach. • OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach on Solaris10 8/07, Solaris 10...
HP ProLiant DL785 G5 and G6 Servers - Maintenance and Service Guide, Seventh Edition
Page 17
... 395911-001 DVD drive, 8/24x 395910-001 11 Processor options Heatsink kit, DL785 G5 AH233-2127A AMD Opteron 8360SE 2.5 GHz 105W 448202-001 replacement kit (G5) AMD Opterton 8358SE 2.4 GHz 105W 448202-002 replacement kit (G5) Spare part number Customer self repair (Chapter 1 (page 7)) 441830-001 ... 397928-001 491101-001 448407-001 448406-001 Mandatory1 Mandatory1 Mandatory1 Optional2 Optional2 Optional2 System components 17 Check the HP Partsurfer website, http://partsurfer.hp.com/, to ensure you have the latest part numbers associated with this server. IMPORTANT: The list of part...
... 395911-001 DVD drive, 8/24x 395910-001 11 Processor options Heatsink kit, DL785 G5 AH233-2127A AMD Opteron 8360SE 2.5 GHz 105W 448202-001 replacement kit (G5) AMD Opterton 8358SE 2.4 GHz 105W 448202-002 replacement kit (G5) Spare part number Customer self repair (Chapter 1 (page 7)) 441830-001 ... 397928-001 491101-001 448407-001 448406-001 Mandatory1 Mandatory1 Mandatory1 Optional2 Optional2 Optional2 System components 17 Check the HP Partsurfer website, http://partsurfer.hp.com/, to ensure you have the latest part numbers associated with this server. IMPORTANT: The list of part...
HP ProLiant DL785 G5 and G6 Servers - Maintenance and Service Guide, Seventh Edition
Page 18
... GHz 75W replacement kit (G5) 448208-001 AMD Opteron 8354 2.2 GHz 75W replacement kit (G5) 448208-002 AMD Opteron 8384 2.7 GHz 75W replacement kit (G5) 509498-001 AMD Opteron 8380 2.5 GHz 75W replacement kit (G5) 500540-001 AMD Opteron 8378 2.4 GHz 75W replacement kit (G5) 500539-001 AMD Opteron 8376... 8393 SE 3.1 GHz 105W 535363-001 replacement kit (G5) AMD Opteron 8389 2.9 GHz 75W replacement kit (G5) 530520-003 AMD Opteron 8387 2.8 GHz 75W replacement kit (G5) 530520-002 AMD Opteron 8381 HE 2.5 GHz 55W 530531-002 replacement kit (G5) AMD Opteron 8425 HE 2.1 GHz (G6) 539686-001...
... GHz 75W replacement kit (G5) 448208-001 AMD Opteron 8354 2.2 GHz 75W replacement kit (G5) 448208-002 AMD Opteron 8384 2.7 GHz 75W replacement kit (G5) 509498-001 AMD Opteron 8380 2.5 GHz 75W replacement kit (G5) 500540-001 AMD Opteron 8378 2.4 GHz 75W replacement kit (G5) 500539-001 AMD Opteron 8376... 8393 SE 3.1 GHz 105W 535363-001 replacement kit (G5) AMD Opteron 8389 2.9 GHz 75W replacement kit (G5) 530520-003 AMD Opteron 8387 2.8 GHz 75W replacement kit (G5) 530520-002 AMD Opteron 8381 HE 2.5 GHz 55W 530531-002 replacement kit (G5) AMD Opteron 8425 HE 2.1 GHz (G6) 539686-001...
HP ProLiant DL785 G5 and G6 Servers - Maintenance and Service Guide, Seventh Edition
Page 82
...2 one hard drive, three power supplies, and four processor cells installed 3 IMPORTANT: To ensure the ProLiant DL785 G5 Server has sufficient power during normal operation, a server configured with HP supported high powered graphics cards rated at low-line power with a large amount of memory, hard drives,...at100 V ac 14A at http:// h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls. If a you wish to RBSU. If the power solution is plugged into low-line power. at 3 P.S.U. At POST, the ProLiant DL785 G5 server automatically detects whether the power supplies are...
...2 one hard drive, three power supplies, and four processor cells installed 3 IMPORTANT: To ensure the ProLiant DL785 G5 Server has sufficient power during normal operation, a server configured with HP supported high powered graphics cards rated at low-line power with a large amount of memory, hard drives,...at100 V ac 14A at http:// h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls. If a you wish to RBSU. If the power solution is plugged into low-line power. at 3 P.S.U. At POST, the ProLiant DL785 G5 server automatically detects whether the power supplies are...