Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 4
...disks with DiskSuite ...36 Troubleshooting ...38 Known issues...38 Write cache not flushed on shutdown...38 Solaris stops responding on HP ProLiant DL580 G5 server 38 RAID mode not supported ...39 Kernel Panic after disabling PCI devices in RBSU 39 Network configuration fails during interactive ... Deployment Pack job fails ...45 Installation terminates prematurely ...46 JumpStart reverts to interactive configuration 46 Installation succeeds but server fails to boot 47 Installation succeeds but no network availability after reboot 47 Additional documentation ...48 Where to go for additional...
...disks with DiskSuite ...36 Troubleshooting ...38 Known issues...38 Write cache not flushed on shutdown...38 Solaris stops responding on HP ProLiant DL580 G5 server 38 RAID mode not supported ...39 Kernel Panic after disabling PCI devices in RBSU 39 Network configuration fails during interactive ... Deployment Pack job fails ...45 Installation terminates prematurely ...46 JumpStart reverts to interactive configuration 46 Installation succeeds but server fails to boot 47 Installation succeeds but no network availability after reboot 47 Additional documentation ...48 Where to go for additional...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 6
...1 Applicable HP ProLiant servers BL20p G4 BL25p BL25p G2 BL260c G5 BL2x220c G5 BL35p BL45p BL45p G2 BL460c BL460c G6 BL465c BL480c BL490c G6 BL680c G5 BL685c BL685c G5 DL385 G6 DL140 G2 DL145 DL145 G2 DL160 G5 DL165 G5 DL180 G5 DL185 G5 DL360 G4p SCSI DL360 G5 DL360 G6 DL365 DL365 G5 DL370 G6 DL380 G4 DL380 G5 DL380 G6... DL585 G6 DL385 DL385 G2 DL385 G5 DL385 G5p DL580 G3 DL580 G4 DL580 G5 DL585 DL585 G2 DL585 G5 DL785 G5 ML370 G4 ML370 G5 ML370 G6 ML570 G3 ...
...1 Applicable HP ProLiant servers BL20p G4 BL25p BL25p G2 BL260c G5 BL2x220c G5 BL35p BL45p BL45p G2 BL460c BL460c G6 BL465c BL480c BL490c G6 BL680c G5 BL685c BL685c G5 DL385 G6 DL140 G2 DL145 DL145 G2 DL160 G5 DL165 G5 DL180 G5 DL185 G5 DL360 G4p SCSI DL360 G5 DL360 G6 DL365 DL365 G5 DL370 G6 DL380 G4 DL380 G5 DL380 G6... DL585 G6 DL385 DL385 G2 DL385 G5 DL385 G5p DL580 G3 DL580 G4 DL580 G5 DL585 DL585 G2 DL585 G5 DL785 G5 ML370 G4 ML370 G5 ML370 G6 ML570 G3 ...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 38
...see "Basic troubleshooting techniques." Known issues The following error message may be displayed on a DL580 G5 server. • OS releases affected-Solaris 10 8/07, 5/08 • Hardware affected-HP ProLiant DL580 G5 • Description-Solaris may stop responding, or will not respond properly during deployment if a...: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will respond poorly if a PCI-Express Controller is configured in PCIExpress slots 1, 2, 4, 5, 7, or 8 on...
...see "Basic troubleshooting techniques." Known issues The following error message may be displayed on a DL580 G5 server. • OS releases affected-Solaris 10 8/07, 5/08 • Hardware affected-HP ProLiant DL580 G5 • Description-Solaris may stop responding, or will not respond properly during deployment if a...: # swap -d Optionally, shutdown the system using these commands: # init 0 # halt Solaris stops responding on HP ProLiant DL580 G5 server Solaris may stop responding, or will respond poorly if a PCI-Express Controller is configured in PCIExpress slots 1, 2, 4, 5, 7, or 8 on...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 39
...HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is fixed with network setup at installation time, and the installation might cause Solaris to stop responding, halt due to kernel panic, or produce other undesirable behavior. • Workaround-Unless otherwise indicated, HP... does not support using ROM-Based Setup Utility (RBSU). • OS releases affected-All • Servers affected-All supported ProLiant servers • Description-Disabling PCI devices in RAID mode. Network...
...HP ProLiant BL260c G5 or BL280c G6 blade server when the SATA controller is fixed with network setup at installation time, and the installation might cause Solaris to stop responding, halt due to kernel panic, or produce other undesirable behavior. • Workaround-Unless otherwise indicated, HP... does not support using ROM-Based Setup Utility (RBSU). • OS releases affected-All • Servers affected-All supported ProLiant servers • Description-Disabling PCI devices in RAID mode. Network...
Sun Solaris 10 Deployment Guide for HP ProLiant Servers
Page 41
... bcme fails to attach Broadcom gigabit Ethernet NIC fails to attach. • OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach on Solaris10 8/07, Solaris...
... bcme fails to attach Broadcom gigabit Ethernet NIC fails to attach. • OS releases affected-Solaris 10 8/07, 5/08, 10/08 • Servers affected-HP ProLiant BL685c, BL685c G5, BL680c, BL480c, BL260c G5 • Description-The Broadcom NetXtreme Gigabit Ethernet Driver (BRCMbcme) v10.4.5 or later successfully installs but fails to attach on Solaris10 8/07, Solaris...
HP ProLiant DL785 G5 and G6 Servers - Maintenance and Service Guide, Seventh Edition
Page 82
..., and processors installed 2 one hard drive, three power supplies, and four processor cells installed 3 IMPORTANT: To ensure the ProLiant DL785 G5 Server has sufficient power during POST to high-line power or low-line power. Specification Value Rated input frequency 47- 63 Hz ...line (200 - 240 V) ac server configuration. at 3 P.S.U. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in this low-line configuration as sufficient using the ProLiant DL785 G5 power calculator at http:// h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls...
..., and processors installed 2 one hard drive, three power supplies, and four processor cells installed 3 IMPORTANT: To ensure the ProLiant DL785 G5 Server has sufficient power during POST to high-line power or low-line power. Specification Value Rated input frequency 47- 63 Hz ...line (200 - 240 V) ac server configuration. at 3 P.S.U. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in this low-line configuration as sufficient using the ProLiant DL785 G5 power calculator at http:// h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls...