Optical Drive and Library SCSI-2 Command Reference
Page 16
... Descriptor 2-144 Table 2-130. Numerical List of Data Transfer Elements 3-23 Table 3-25. Send Diagnostic Command CDB 3-35 xv Inquiry Command CDB 3-14 Table 3-12. Firmware Information Page 3-17 Table 3-17. Reserve Command CDB 3-18 Table 3-18. Receive Diagnostic Results Command CDB 3-33 Table 3-30. Tables Table 2-129. Alphabetical List of...
... Descriptor 2-144 Table 2-130. Numerical List of Data Transfer Elements 3-23 Table 3-25. Send Diagnostic Command CDB 3-35 xv Inquiry Command CDB 3-14 Table 3-12. Firmware Information Page 3-17 Table 3-17. Reserve Command CDB 3-18 Table 3-18. Receive Diagnostic Results Command CDB 3-33 Table 3-30. Tables Table 2-129. Alphabetical List of...
Optical Drive and Library SCSI-2 Command Reference
Page 66
... Sense Length (33H)a 5-6 Reserved (0) 7 RelAdr WBus32 WBus16 Sync Linked Rsvd Cmd SftRe (1) (0) (0) (1) (1) (0) Que (1) (0) 8-15 Vendor Identification "HP~~~~~~" (ASCII)b 16-31 Product Identification "C1113J ASCII)b ("C1113F~~~~~~~~~~" for 2.6 Gbyte capacity drives) 32-35 Product Revision Level (Current firmware version in ASCII) 36-39 Manufacturing Date Code (Current ASCII data) 40-49 Serial Number (Current...
... Sense Length (33H)a 5-6 Reserved (0) 7 RelAdr WBus32 WBus16 Sync Linked Rsvd Cmd SftRe (1) (0) (0) (1) (1) (0) Que (1) (0) 8-15 Vendor Identification "HP~~~~~~" (ASCII)b 16-31 Product Identification "C1113J ASCII)b ("C1113F~~~~~~~~~~" for 2.6 Gbyte capacity drives) 32-35 Product Revision Level (Current firmware version in ASCII) 36-39 Manufacturing Date Code (Current ASCII data) 40-49 Serial Number (Current...
Optical Drive and Library SCSI-2 Command Reference
Page 67
... SCSI selection, the Peripheral Qualifier field is always 33H. This field is set 00H, (Direct Access Device). CmdQue The Command queuing bit of the current firmware to the RESET condition with the hard RESET. 2-30 Chapter 2 If Direct Access Inquiry Response (DAIR) has been enabled, the Peripheral Device Type field is...
... SCSI selection, the Peripheral Qualifier field is always 33H. This field is set 00H, (Direct Access Device). CmdQue The Command queuing bit of the current firmware to the RESET condition with the hard RESET. 2-30 Chapter 2 If Direct Access Inquiry Response (DAIR) has been enabled, the Peripheral Device Type field is...
Optical Drive and Library SCSI-2 Command Reference
Page 202
...Jukebox SCSI-2 Commands Table 3-12 Vital Product Data Page Codes Page Code Description 0 80H C0H Supported vital product data pages Unit serial number Firmware information page Table 3-13 Inquiry Command Data Standard Inquiry Data Format Byte 7 6 5 4 3 2 1 0 0 Peripheral Qualifier (0) Peripheral... (2) 3 AENC TrmIOP Reserved (0) (0) (0) Response Data Format (2) 4 Additional Length (1FH) 5-7 Reserved (0) 8-15 Vendor Identification (HP) 16-31 Product Identification 32-35 Product Revision Level RMB Removable medium bit. When this bit is set to X3131- 199x.
...Jukebox SCSI-2 Commands Table 3-12 Vital Product Data Page Codes Page Code Description 0 80H C0H Supported vital product data pages Unit serial number Firmware information page Table 3-13 Inquiry Command Data Standard Inquiry Data Format Byte 7 6 5 4 3 2 1 0 0 Peripheral Qualifier (0) Peripheral... (2) 3 AENC TrmIOP Reserved (0) (0) (0) Response Data Format (2) 4 Additional Length (1FH) 5-7 Reserved (0) 8-15 Vendor Identification (HP) 16-31 Product Identification 32-35 Product Revision Level RMB Removable medium bit. When this bit is set to X3131- 199x.
Optical Drive and Library SCSI-2 Command Reference
Page 203
... Vital Product Data Pages Byte 7 6 5 4 3 2 1 0 0 Peripheral Qualifier (0) Peripheral Device Type (08H) 1 Page Code (0) 2 Reserved (0) 3 Page Length (03H) 4 0 (this page) 5 80H (Unit Serial Number Page) 6 C0H (Firmware Information Page - Vendor Identification All unused bytes are filled with a blank space. (ASCII) Product Identification String All unused bytes are not supported.
... Vital Product Data Pages Byte 7 6 5 4 3 2 1 0 0 Peripheral Qualifier (0) Peripheral Device Type (08H) 1 Page Code (0) 2 Reserved (0) 3 Page Length (03H) 4 0 (this page) 5 80H (Unit Serial Number Page) 6 C0H (Firmware Information Page - Vendor Identification All unused bytes are filled with a blank space. (ASCII) Product Identification String All unused bytes are not supported.
Optical Drive and Library SCSI-2 Command Reference
Page 279
... to the encoder was too long 48 Unexpected sequence of the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware sequence occurred in the ODC chip 50 Asynchronous interrupt of the DSP was detected 51 Unexpected ID value was detected 52 Both unexpected and expected...
... to the encoder was too long 48 Unexpected sequence of the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware sequence occurred in the ODC chip 50 Asynchronous interrupt of the DSP was detected 51 Unexpected ID value was detected 52 Both unexpected and expected...
Optical Drive and Library SCSI-2 Command Reference
Page 281
... to the encoder was too long 48 Unexpected sequence of the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware sequence occurred in the ODC chip 50 Asynchronous interrupt of the DSP was detected 51 Unexpected ID value was detected 52 Both unexpected and expected...
... to the encoder was too long 48 Unexpected sequence of the error correction occurred 4E Unexpected interrupt was detected in the ODC chip 4F Unexpected firmware sequence occurred in the ODC chip 50 Asynchronous interrupt of the DSP was detected 51 Unexpected ID value was detected 52 Both unexpected and expected...
Optical Drive and Library SCSI-2 Command Reference
Page 291
Description AC This sense key shall be corrected manually Firmware download needed (boot code) Download checksum error Move error (Check additional sense bytes) (Table B-6 on page B-14) Invalid parameter list length Unsupported command Invalid address - (...
Description AC This sense key shall be corrected manually Firmware download needed (boot code) Download checksum error Move error (Check additional sense bytes) (Table B-6 on page B-14) Invalid parameter list length Unsupported command Invalid address - (...
Optical Drive and Library SCSI-2 Command Reference
Page 309
Autochanger Error Codes Hardware Error Codes Table B-8 Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code (hex.) Failure Description JUKEBOX CONTROLLER PCA ERROR CODES 00 No error 01 ROM checksum error 03 RAM test ... test error 05 Controlled area of RAM checksum error a 06 Illegal interrupt encountered by microprocessor 07 Illegal CPU exception encountered by microprocessor 09 Firmware error SCSI INTERFACE-SPECIFIC ERROR CODES 0B SCSI controller register error 0C SCSI controller IC's RAM failed 0D SCSI controller message error 0E SCSI...
Autochanger Error Codes Hardware Error Codes Table B-8 Hardware Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code (hex.) Failure Description JUKEBOX CONTROLLER PCA ERROR CODES 00 No error 01 ROM checksum error 03 RAM test ... test error 05 Controlled area of RAM checksum error a 06 Illegal interrupt encountered by microprocessor 07 Illegal CPU exception encountered by microprocessor 09 Firmware error SCSI INTERFACE-SPECIFIC ERROR CODES 0B SCSI controller register error 0C SCSI controller IC's RAM failed 0D SCSI controller message error 0E SCSI...
Optical Drive and Library SCSI-2 Command Reference
Page 319
...Failure Description (hex.) 00 No error 01 Vertical over voltage exceeded limit set by firmware 02 Vertical over force exceeded limit set by firmware 03 Vertical servo error 04 Vertical timeout 05 Vertical open path 06 Vertical closed path... 0A Plunge over voltage exceeded limit set by firmware 0B Plunge over force exceeded limit set by firmware 0C Plunge servo error 0D Plunge timeout 0E Plunge open path 0F Plunge closed... (See Table 3-45 on page 3-47.) For all models EXCEPT 40fx, 80ex, 125ex, and 220mx. B-32 Appendix B Runtime.
...Failure Description (hex.) 00 No error 01 Vertical over voltage exceeded limit set by firmware 02 Vertical over force exceeded limit set by firmware 03 Vertical servo error 04 Vertical timeout 05 Vertical open path 06 Vertical closed path... 0A Plunge over voltage exceeded limit set by firmware 0B Plunge over force exceeded limit set by firmware 0C Plunge servo error 0D Plunge timeout 0E Plunge open path 0F Plunge closed... (See Table 3-45 on page 3-47.) For all models EXCEPT 40fx, 80ex, 125ex, and 220mx. B-32 Appendix B Runtime.
Optical Drive and Library SCSI-2 Command Reference
Page 323
Picker motor drive voltage exceeded limit set by firmware. Carriage motor force exceeded limit set by firmware. Picker motor overcurrent detected by firmware. Picker motor force exceeded limit set by firmware. Picker motor measured voltage less than expected. Low power supply during motion. Cartridge ...-Move Error Codes Micro-Move Error Codes Error Code Failure Description (hex.) 6E Test failed Micro-Move Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code (hex.) 0 1 2 3 4 5 6 7 8 9 A B C D E 10 11 Description No error Carriage motor drive ...
Picker motor drive voltage exceeded limit set by firmware. Carriage motor force exceeded limit set by firmware. Picker motor overcurrent detected by firmware. Picker motor force exceeded limit set by firmware. Picker motor measured voltage less than expected. Low power supply during motion. Cartridge ...-Move Error Codes Micro-Move Error Codes Error Code Failure Description (hex.) 6E Test failed Micro-Move Error Codes (For the 40fx, 80ex, 125ex, and 220mx models ONLY) Error Code (hex.) 0 1 2 3 4 5 6 7 8 9 A B C D E 10 11 Description No error Carriage motor drive ...
HP SureStore 220mx Optical Jukebox User's Guide
Page 59
Press ENTER. If your jukebox has two optical drives, you select any log except 4 (drive cartridge loads), the log information displays immediately. Description 1 Firmware revision of the jukebox 4 Total cartridge loads for Drive 1 information. Press NEXT until INFO * appears in the display. 1. If you can press ENTER for the ...
Press ENTER. If your jukebox has two optical drives, you select any log except 4 (drive cartridge loads), the log information displays immediately. Description 1 Firmware revision of the jukebox 4 Total cartridge loads for Drive 1 information. Press NEXT until INFO * appears in the display. 1. If you can press ENTER for the ...
16/24-Slot Jukebox Troubleshooting
Page 1
... from the factory is removed. Select the optical drive in drive. CAUTION: NEVERUSEACUSTOMER'S DISK OR A DISK CONTAINING USABLE DATA FOR THE FOLLOWING TEST. Download latest firmware. 3. Check for obstructions in vertical path, on picker and in question by clicking on carriage - Invalid test configuration - run Test 15. run Test 16, then...
... from the factory is removed. Select the optical drive in drive. CAUTION: NEVERUSEACUSTOMER'S DISK OR A DISK CONTAINING USABLE DATA FOR THE FOLLOWING TEST. Download latest firmware. 3. Check for obstructions in vertical path, on picker and in question by clicking on carriage - Invalid test configuration - run Test 15. run Test 16, then...
16/24-Slot Jukebox Troubleshooting
Page 2
...C1113F C1113F C1113F C1113F C1113J C1113J C1113J C1113J NOTE: Product ID need not match actual product number. Check that drive and jukebox firmware are part of the information returned when performing an inquiry command or scan of receiving a defective replacement part is intermittent, check... PCA to aid troubleshooting The recommended procedure is probably not necessary. NO See Note A Note A Check: 1. Update drive and jukebox controller firmware, if necessary. Connect laptop to Jukebox and scan bus or reboot host computer to view SCSI IDs YES Display shows "TESTING" NO then ...
...C1113F C1113F C1113F C1113F C1113J C1113J C1113J C1113J NOTE: Product ID need not match actual product number. Check that drive and jukebox firmware are part of the information returned when performing an inquiry command or scan of receiving a defective replacement part is intermittent, check... PCA to aid troubleshooting The recommended procedure is probably not necessary. NO See Note A Note A Check: 1. Update drive and jukebox controller firmware, if necessary. Connect laptop to Jukebox and scan bus or reboot host computer to view SCSI IDs YES Display shows "TESTING" NO then ...
HP SureStore 1200mx/2200mx Optical Jukebox User's Guide
Page 63
After you wish to access displays and then press ENTER. (A "*" indicates that identifies the type of firmware used in this password are more selections beneath the displayed choice.) 5. Enter the administration password. Press NEXT until INFO * displays... Instructions for entering this chapter. 3. Information Logs Log Name Description REVISION JUKEBOX * product # SN # FW TYPE ## DRIVES # SLOTS # Jukebox firmware version number. Code that there are in "Entering the Administration Menu Password" in the unit. Press NEXT until the name of available storage slots in...
After you wish to access displays and then press ENTER. (A "*" indicates that identifies the type of firmware used in this password are more selections beneath the displayed choice.) 5. Enter the administration password. Press NEXT until INFO * displays... Instructions for entering this chapter. 3. Information Logs Log Name Description REVISION JUKEBOX * product # SN # FW TYPE ## DRIVES # SLOTS # Jukebox firmware version number. Code that there are in "Entering the Administration Menu Password" in the unit. Press NEXT until the name of available storage slots in...
HP SureStore 1200mx/2200mx Optical Jukebox User's Guide
Page 64
... next five rows. MOVES FLIPS XLATES ROTATES DRIVE LOADS * DRIVE # DRIVE FW * D# REV x.xx Total moves and move attempts by the disk transport mechanism. Drive firmware revision code. "D#" is the drive number and x.xx is the drive number. HOURS Number of unrecoverable errors (commands that did not successfully complete).
... next five rows. MOVES FLIPS XLATES ROTATES DRIVE LOADS * DRIVE # DRIVE FW * D# REV x.xx Total moves and move attempts by the disk transport mechanism. Drive firmware revision code. "D#" is the drive number and x.xx is the drive number. HOURS Number of unrecoverable errors (commands that did not successfully complete).
HP SureStore 1200mx/2200mx Optical Jukebox User's Guide
Page 92
... a SCSI Bus A Brief Overview of SCSI To use this form of addressing, however, the jukebox application software, the SCSI bus drivers and the host adapter firmware all have to provide more stable termination.
... a SCSI Bus A Brief Overview of SCSI To use this form of addressing, however, the jukebox application software, the SCSI bus drivers and the host adapter firmware all have to provide more stable termination.
HP SureStore 300mx/600mx/700mx Optical Jukebox User's Guide
Page 56
.... Press NEXT until INFO * displays, and then press ENTER. 4. Information Logs Log Name Description REVISION JUKEBOX * product # SN # FW TYPE ## DRIVES # SLOTS # Jukebox firmware version number. Instructions for entering this password are described in this chapter. 3. Start with READY in the unit. Press ENTER to READY. Number of drives... viewing log information, press CANCEL to return to select the information described in the unit. 3- 22 Chapter 3 Product identification string Serial number of firmware used in the jukebox operating logs by using the INFO * menu.
.... Press NEXT until INFO * displays, and then press ENTER. 4. Information Logs Log Name Description REVISION JUKEBOX * product # SN # FW TYPE ## DRIVES # SLOTS # Jukebox firmware version number. Instructions for entering this password are described in this chapter. 3. Start with READY in the unit. Press ENTER to READY. Number of drives... viewing log information, press CANCEL to return to select the information described in the unit. 3- 22 Chapter 3 Product identification string Serial number of firmware used in the jukebox operating logs by using the INFO * menu.
HP SureStore 300mx/600mx/700mx Optical Jukebox User's Guide
Page 57
... in the rows following RECOVERY ERROR * in this selection. DRIVE FW * Press ENTER to select the logs under this table.) Chapter 3 3-23 D# REV x.xx Drive firmware revision code. Returns either NO HARD ENTRIES or ENTRY #. (There may be multiple hard error numbers.) Press ENTER to view the log for the drive...
... in the rows following RECOVERY ERROR * in this selection. DRIVE FW * Press ENTER to select the logs under this table.) Chapter 3 3-23 D# REV x.xx Drive firmware revision code. Returns either NO HARD ENTRIES or ENTRY #. (There may be multiple hard error numbers.) Press ENTER to view the log for the drive...
HP SureStore 300mx/600mx/700mx Optical Jukebox User's Guide
Page 85
... a SCSI Bus A Brief Overview of SCSI To use this form of addressing, however, the jukebox application software, the SCSI bus drivers and the host adapter firmware all have to support this mode of the physical bus. These terminators may be placed at ID 6. Active termination is a resistor network. The following diagram...
... a SCSI Bus A Brief Overview of SCSI To use this form of addressing, however, the jukebox application software, the SCSI bus drivers and the host adapter firmware all have to support this mode of the physical bus. These terminators may be placed at ID 6. Active termination is a resistor network. The following diagram...