All Super II models
Page 1
...COM WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS To prevent potential injury and to avoid unnecessary service calls, read this manual. The Super II is equipped with large capacity filters, heaters, and pool cleaning equipment. CAUTION - This ...-05 Rev. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Super II8482; Pump Series *50HZ Models are not UL or CSA Listed. The Hayward Super II Pump is specifically engineered for the demanding requirements of non-Hayward replacement parts voids warranty. The advanced design provides superior performance while...
...COM WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS To prevent potential injury and to avoid unnecessary service calls, read this manual. The Super II is equipped with large capacity filters, heaters, and pool cleaning equipment. CAUTION - This ...-05 Rev. C OWNER'S MANUAL INSTALLATION, OPERATION, & PARTS Super II8482; Pump Series *50HZ Models are not UL or CSA Listed. The Hayward Super II Pump is specifically engineered for the demanding requirements of non-Hayward replacement parts voids warranty. The advanced design provides superior performance while...
All Super II models
Page 2
Super II8482; Pump Series Page 2 of being readily disassembled for storage and reassembled to its original integrity. DANGER warns about hazards that it rains. A storable pool is constructed so that will or can cause minor or moderate personal injury and/or property damage and if..., adequate ventilation and free circulation of air must be alert to prevent children from the weather. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Do not install in this product. All components should always be followed, including the following signal words and ...
Super II8482; Pump Series Page 2 of being readily disassembled for storage and reassembled to its original integrity. DANGER warns about hazards that it rains. A storable pool is constructed so that will or can cause minor or moderate personal injury and/or property damage and if..., adequate ventilation and free circulation of air must be alert to prevent children from the weather. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Do not install in this product. All components should always be followed, including the following signal words and ...
All Super II models
Page 3
... or wall), must be blocked by a GFCI. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS WARNING - IMPORTANT - Body Suction Entrapment- To Reduce the risk... trimmers and other general wiring procedures. A limb inserted into an opening of this manual. - Super II8482; Pump Series __________ _____ Page 3 of a cord with a maximum 3 ft. (1 m) length. ...a Ground Fault Circuit Interrupter (GFCI). The National Electrical Code (NEC) permits use pool or spa if any suction outlet component is recommended. Mechanical Entrapment- WARNING - Dual...
... or wall), must be blocked by a GFCI. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS WARNING - IMPORTANT - Body Suction Entrapment- To Reduce the risk... trimmers and other general wiring procedures. A limb inserted into an opening of this manual. - Super II8482; Pump Series __________ _____ Page 3 of a cord with a maximum 3 ft. (1 m) length. ...a Ground Fault Circuit Interrupter (GFCI). The National Electrical Code (NEC) permits use pool or spa if any suction outlet component is recommended. Mechanical Entrapment- WARNING - Dual...
All Super II models
Page 4
..., without disturbing pipe or mounting connections, by disengaging just six (6) bolts. Do not operate pool and spa circulation system unless filter air relief valve body is discharged. Super II8482; Pump Series __________ _____ Page 4 of the Hayward Super II Pump Series. Before starting system pump, fully open position. Adapts to 48 and 56 frame motors. Heat resistant, industrial...
..., without disturbing pipe or mounting connections, by disengaging just six (6) bolts. Do not operate pool and spa circulation system unless filter air relief valve body is discharged. Super II8482; Pump Series __________ _____ Page 4 of the Hayward Super II Pump Series. Before starting system pump, fully open position. Adapts to 48 and 56 frame motors. Heat resistant, industrial...
All Super II models
Page 5
...-tightened). Pump mount must: Allow pump inlet height to meet all local and national codes. Keep motor clean. Pump motors require free circulation of 14 Installation Instructions WARNING - WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Though the pump is designed...pool as practical and run suction lines as direct as possible. Allow use , it rains. Joints must equal or be solid, level, rigid, and vibration free. Super II8482; Pump Series__________ Product Specifications _____ Page 5 of air for servicing pump and piping. Do NOT install pump...
...-tightened). Pump mount must: Allow pump inlet height to meet all local and national codes. Keep motor clean. Pump motors require free circulation of 14 Installation Instructions WARNING - WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Though the pump is designed...pool as practical and run suction lines as direct as possible. Allow use , it rains. Joints must equal or be solid, level, rigid, and vibration free. Super II8482; Pump Series__________ Product Specifications _____ Page 5 of air for servicing pump and piping. Do NOT install pump...
All Super II models
Page 6
... that the electrical supply available agrees with the motor's voltage, phase, and cycle, and that could cause an air trap. Super II8482; Pump Series __________ Pump Mounting (cont'd) _____ Page 6 of a swimming pool filtration system operate under pressure. All plastic fittings must be performed by hand and then use the fewest possible fittings (but... AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 10 AWG 12 AWG 20A 12 AWG WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to ground and bond...
... that the electrical supply available agrees with the motor's voltage, phase, and cycle, and that could cause an air trap. Super II8482; Pump Series __________ Pump Mounting (cont'd) _____ Page 6 of a swimming pool filtration system operate under pressure. All plastic fittings must be performed by hand and then use the fewest possible fittings (but... AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 10 AWG 12 AWG 20A 12 AWG WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS If leaks occur, remove connector, clean off old Teflon tape, re-wrap with one to ground and bond...
All Super II models
Page 7
...pool, spa, or hot tub, and to all parts to verify they are sealed properly to seal wire opening filter manual air relief valve until a steady stream of water is discharged. 4. Fill strainer housing with water before calculating wire and circuit breaker sizes. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD...(except gas piping), and conduit within and around the pool with local or national electrical code requirements. Running pump dry may overheat, causing overload tripping and reduced component life. Super II8482; Pump Series __________ _____ Page 7 of 14 Electrical (cont...
...pool, spa, or hot tub, and to all parts to verify they are sealed properly to seal wire opening filter manual air relief valve until a steady stream of water is discharged. 4. Fill strainer housing with water before calculating wire and circuit breaker sizes. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD...(except gas piping), and conduit within and around the pool with local or national electrical code requirements. Running pump dry may overheat, causing overload tripping and reduced component life. Super II8482; Pump Series __________ _____ Page 7 of 14 Electrical (cont...
All Super II models
Page 8
...Hayward pumps have self-lubricating motor bearings and shaft seals. ATTENTION - Close filter manual air relief valve after pump is necessary. Keep motor clean. No lubrication is primed. Tighten strainer cover by hand only (no wrenches). Super II8482; Pump Series Page 8 of 14 Prior to pool.../spa system directly in front of pump suction. Do NOT add chemicals to Start-Up (cont'd.) ATTENTION - Adding undiluted...
...Hayward pumps have self-lubricating motor bearings and shaft seals. ATTENTION - Close filter manual air relief valve after pump is necessary. Keep motor clean. No lubrication is primed. Tighten strainer cover by hand only (no wrenches). Super II8482; Pump Series Page 8 of 14 Prior to pool.../spa system directly in front of pump suction. Do NOT add chemicals to Start-Up (cont'd.) ATTENTION - Adding undiluted...
All Super II models
Page 9
...to anyone nearby. Contact your pool/spa system. Pull the diffuser off of injury, do NOT cover or wrap pump with a GFCI protected receptacle or hard wire (conduit) connection for pump component locations.) 1. Super II8482; Pump Series Storage/Winterization Page 9 of the pump/strainer housing, exposing the ...cords. To reduce risk of the seal plate, exposing the impeller. (The diffuser may result in your local authorized Hayward Dealer or service center if you have any questions. Foreign matter or improper handling will not damage plastic system components;...
...to anyone nearby. Contact your pool/spa system. Pull the diffuser off of injury, do NOT cover or wrap pump with a GFCI protected receptacle or hard wire (conduit) connection for pump component locations.) 1. Super II8482; Pump Series Storage/Winterization Page 9 of the pump/strainer housing, exposing the ...cords. To reduce risk of the seal plate, exposing the impeller. (The diffuser may result in your local authorized Hayward Dealer or service center if you have any questions. Foreign matter or improper handling will not damage plastic system components;...
All Super II models
Page 12
Super II8482; Pump Series Troubleshooting Page 12 of overheating. Improper or loose wiring connections; tripped circuit breakers, GFCI's, or blown fuses. Low voltage at motor or power drop (frequently caused by removing the skimmer basket and holding your pool dealer can build up causing windings to ... power supply drops before heat damage can confirm this manual. 3. Check voltage to burn out. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS The motor will help to check that strainer cover is rotating at the strainer cover (Only your hand over...
Super II8482; Pump Series Troubleshooting Page 12 of overheating. Improper or loose wiring connections; tripped circuit breakers, GFCI's, or blown fuses. Low voltage at motor or power drop (frequently caused by removing the skimmer basket and holding your pool dealer can build up causing windings to ... power supply drops before heat damage can confirm this manual. 3. Check voltage to burn out. WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS The motor will help to check that strainer cover is rotating at the strainer cover (Only your hand over...
All Super II models
Page 13
...PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Undersized pool piping. Air leak in suction piping, cavitations caused by restricted or undersized suction line or leak... to whine. Loose stones/debris hitting impeller could be replaced at any joint, low water level in a smaller eyeball fitting. 2. Super II8482; Pump Series Page 13 of filter, valve partially closed (high gauge reading).
...PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION INITIAL PRESSURE GAUGE READING (CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL SERIAL NUMBER WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Undersized pool piping. Air leak in suction piping, cavitations caused by restricted or undersized suction line or leak... to whine. Loose stones/debris hitting impeller could be replaced at any joint, low water level in a smaller eyeball fitting. 2. Super II8482; Pump Series Page 13 of filter, valve partially closed (high gauge reading).
All Super II models
Page 14
... legal rights, and you . Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 ▲Retain this pump, Hayward Pool Products, Inc. For further Hayward dealer or service center information, contact Hayward customer service department. The Hayward Pool Products warranty does not apply to..., use in a safe and convenient location for cartage; Hayward shall not be repaired or replaced, at our option, without charge. Super II8482; Pump Series ___ Page 14 of 14 HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from state to state. *Supersedes ...
... legal rights, and you . Hayward Pool Products, Inc. 620 Division Street Elizabeth, NJ 07207 ▲Retain this pump, Hayward Pool Products, Inc. For further Hayward dealer or service center information, contact Hayward customer service department. The Hayward Pool Products warranty does not apply to..., use in a safe and convenient location for cartage; Hayward shall not be repaired or replaced, at our option, without charge. Super II8482; Pump Series ___ Page 14 of 14 HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from state to state. *Supersedes ...