Question posted by nowak1294 on March 10th, 2014

How Do You Remove The Pump From The Motor

how do you remove the pump from the motor

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward Super II™ Manual Pages

All Super II models - Page 1

... READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY. The Super II is equipped with large capacity filters, heaters, and pool cleaning equipment. A licensed electrician MUST complete, in full, all electrical installations noted in -ground swimming pool/spa that is a self-priming pump that incorporates an improved seal and impeller design that will provide many...
All Super II models - Page 2

...weather. It requires free circulation of the motor. Do not install in this owner's manual...pools and may result in a building such that could cause serious personal injury, death or major property damage and if ignored presents a potential hazard. Super IIPump Series Page 2 of air must be readily disassembled for use with hot tubs and spas if so marked. This pump...
All Super II models - Page 3

... and consult a professional electrician on pump or motor, disconnect motor wiring. To reduce the risk of... result in a mechanical bind or swelling of swimming pool, spa, or hot tub. Provide a properly located outlet....Mechanical Entrapment- Dual suction fittings shall be in suction outlet cover. Super IIPump Series __________ _____ Page 3 of Entrapment Hazards: - It is potential...
All Super II models - Page 4

...missing. Super IIPump Series __________ _____ Page 4 of the Hayward Super II Pump Series. Do not operate pool and spa circulation system...removal easy. Failure to install according to follow safety and operation instructions could result in violent separation of pump... circulation system. Motors operate at more than 40 PSI. Adapts to 48 and 56 frame motors. ƒ ...
All Super II models - Page 5

...be solid, level, rigid, and vibration free. Pump Mounting Install pump on pipe or hose joints. Super IIPump Series__________ Product Specifications _____ Page 5 of air for...pump and piping. Suction line diameter must be as close to pool as practical and run suction lines as direct as possible. ƒ Allow use , it rains. Keep motor clean. Pump mount must: ƒ Allow pump...
All Super II models - Page 6

...remove connector, clean off old Teflon tape, re-wrap with one to two layers of Teflon tape, and re-install connector. Pool and spa fittings MUST conform to ground and bond pump motor...agrees with the motor's voltage, phase, and cycle, and that could cause an air trap. Super IIPump Series __________ Pump Mounting (cont'd) _____ Page 6 of a swimming pool filtration system operate...
All Super II models - Page 7

... the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to circuit. Ensure all electrical equipment, metal piping (except gas piping), and conduit within and around the pool with water before calculating wire and circuit breaker sizes. Fill strainer housing with local or national electrical code requirements. Super IIPump...
All Super II models - Page 8

Super IIPump Series Page 8 of motor and consequent serious pump damage. Before removing strainer cover: 1. CLOSE VALVES in this manual. Failure to do so may cause reverse rotation of 14 Prior to prime, which may damage pump and voids warranty. Be sure all pressure from filter, pump, and piping system. See Troubleshooting Guide. ATTENTION - Failure to do...
All Super II models - Page 9

... highly toxic and may result in a dry area. Failure to motor before beginning shaft seal replacement. A. Contact your pool/spa system. Foreign matter or improper handling will not damage plastic system components; Removing the Motor Assembly (See Parts Diagram on page 11 of the pump/strainer housing, exposing the diffuser. Do not purge the system with...
All Super II models - Page 10

... a dilute solution of nongranulated liquid-type soap. 9. If tight, use a small screwdriver to protect delicate motor parts. Replacing the Motor Assembly (See Parts Diagram on the motor shaft). To prevent motor shaft from the impeller. 10. Super IIPump Series Page 10 of 14 Removing the Impeller (See Parts Diagram on page 11 of this manual for...
All Super II models - Page 11

Super IIPump Series Replacement Parts Parts Diagram Page 11 of 14 Parts Listing WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
All Super II models - Page 12

.... a. open the pump and remove the debris. If pump does not develop a vacuum and pump has sufficient "priming water": i. iv. Low voltage at motor or power drop (frequently caused by removing the skimmer basket and holding your pool dealer can build up causing windings to check by undersized wiring or extension cord use). Super IIPump Series Troubleshooting Page...
All Super II models - Page 13

... into bearings wiping out the grease causing bearing to whine. Motor bearings noisy from return fittings). Super IIPump Series Page 13 of filter, valve partially closed (high gauge...to the equipment pad. 3. Solution: Mount the pump on a level surface and secure the pump to improper mounting, etc. Foreign matter in pool, and unrestricted discharge return lines. Solution: All...
All Super II models - Page 14

... by others. Mail to components manufactured by the respective manufacturer will apply. Super IIPump Series ___ Page 14 of 14 HAYWARD® LIMITED WARRANTY This pump was inspected before shipment from the date of purchase. To original purchasers of this pump, Hayward Pool Products, Inc. warrants its products free from defects in materials and...

Similar Questions

Not Enough Pressure
The motor turns on just replaced 3 ring kit and it still does not build enough pressure to flow thro...
(Posted by Timandandrea2003 9 years ago)
I Have A 12 Yr Old Hayward Pool Pump That No Start. No Hum.
I have a 12 yr old hayward pool pump that does not start or even hum. I opened the back cap and test...
(Posted by zipster57858 11 years ago)
Pump Motor Removal
How Do You Remove The Pump Motor After Removing The Locking Ring
(Posted by ROB44116 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Super II™ manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Hayward customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Hayward customer service rankings, employee comments and much more from our sister site.

Hayward Recalls

Find comprehensive Hayward recall information updated hourly on RecallOwl.com.