Haier HB6000VD1M22 Support and Manuals
Get Help and Manuals for this Haier item
This item is in your list!
View All Support Options Below
Free Haier HB6000VD1M22 manuals!
Problems with Haier HB6000VD1M22?
Ask a Question
Free Haier HB6000VD1M22 manuals!
Problems with Haier HB6000VD1M22?
Ask a Question
Popular Haier HB6000VD1M22 Manual Pages
User Manual - Page 1
..., PERSONAL INJURY OR PROPERTY DAMAGE.
FOLLOW ALL LOCAL CODES. IN THE ABSENCE OF LOCAL CODES REFER TO : NATIONAL ELECTRICAL CODE NFPA 70 NFPA 90A & 90B UNIFORM MECHANICAL CODE
READ THESE INSTRUCTIONS COMPLETELY BEFORE ATTEMPTING TO INSTALL OR SERVICE THIS APPLIANCE. MODEL # HB
M20 HB
M22
MODEL # HB
V20 HB
V22
INSTALLATION DATE
The information contained in this booklet is subject...
User Manual - Page 2
...Replacement Parts Source Installation Requirements Air Flow Orientation Horizontal Left-Hand Instructions Refrigerant Tubing Condensate Removal Electrical Connections Thermostat Wiring Orifice Change Circulating Air Duct Blower Performance Start-up Regular Maintenance Model.... This appliance is approved for installation in accordance with published codes.In the absence of substantial fines...
User Manual - Page 4
PHYSICAL DIMENSIONS of 3 Ton
PLASTIC BREAKER COVER
INLET BOTTOM SIDE VIEW ELECTRICAL POWER SUPPLY
SUCTION LINE LIQUID LINE
LOW VOLT SUPPLY
ELECTRICAL POWER SUPPLY
4
User Manual - Page 5
PHYSICAL DIMENSIONS of 4,5 Ton
PLASTIC BREAKER COVER
INLET BOTTOM SIDE VIEW ELECTRICAL POWER SUPPLY
SUCTION LINE LIQUID LINE
LOW VOLT SUPPLY
ELECTRICAL POWER SUPPLY
5
User Manual - Page 6
.... When more than one appliance is designed for service or replacement must be installed in garages, ware houses or other areas where they may generate a glow, spark or flame capable of vehicles. REPLACEMENT PARTS SOURCE Replacement parts are available through local distributors.When ordering replacement parts, give the COMPLETE model and serial numbers shown on a platform when deemed...
User Manual - Page 7
front (see page 6) Important: Remove the horizontal pan when unit is installed in unconditioned i.e. (Garage, Attic ) application, or downflow applications, and install insulation kit on vertical ( donut shape ) drain pan.
*Upflow Discharge *Air Handler is factory ready for Upflow & Horizontal Right Discharge Application for 3*4*5 as shown. *Air ...
User Manual - Page 8
... of the cavity.
6) Replace the J-shape metal bracket or brackets on the vertical drain pan and place the plastic oval gasket on the right lower service panel.
7) The Airhandler can now be leveled and then pitched 1/4" toward drain side. Before setting up flowrator assembly for proper drainage by the installer and placed under the...
User Manual - Page 9
...
The insulation should terminate at the drain pan connection, this trap, in inches, must be supported or routed to insure proper drainage. A "P " trap is coated with oils that can be... will dissolve Styrofoam and certain types of these materials.
REFRIGERANT TUBING
Refrigerant tubing should be installed as to prevent leakage and act as a lubricant. A trap must not contain any ...
User Manual - Page 10
... that kit. Model No.
2 Ton 3 Ton 4 Ton 5 Ton
5 Ton -E
Min. Blower
running Over-current Motor
Ampacity 208/230 FLA
208/230
Blower Motor H.P.
1.2/1.2 15/15
0.9
1/8
2.5/2.5 15/15
2.0
1/3
3.3/3.3 15/15
2.6
1/2
4.4/4.4 15/15
3.5
1/2
5.0/5.0 15/15
4.0
3/4
WARNING A MEANS OF STRAIN RELIEF MUST BE INSTALLED TO THIS APPLIANCE AT THE ELECTRICAL SERVICE ENTRANCE. All pertinent...
User Manual - Page 11
... power supply Respectively Right: Indoor unit power supply.
1
2
SELECT SWITCH
3 4
5
6
OFF FAN ONLY E. R : AC24V
TERMOSTAT
Y : COMPRESSOR
G
O
Y
R
C
G : FAN
O : 4 -WAY VALUE
TO INDOOR
For detailed Thermostat, please connect FAN RELAY
CONTROL
corresponding terminal according to above
control specification. OR
YL
RD
BL
BL
24V
COM
O
YCR
TO OUTDOOR UNIT R,C,Y,O TRANSFORMER...
User Manual - Page 12
...TERMOSTAT
Y : COMPRESSOR
G
Y
R
C
G : FAN
For detailed Thermostat, please connect corresponding terminal according to above control specification. The detailed infor see the following diagram 6.
If need...4
control Environment temperature,
SWITCH
can adopt different power switch
show diagram 5. TO FAN RELAY CONTROL RD
BL
CY TO OUTDOOR UNIT C,Y
RD
BL
24V
COM
TRANSFORMER
Diagram...
User Manual - Page 13
... installed as per local and/or national code.Refer to NFPA 90A & 90B and the National Environmental Systems Contractors Association Manual ...manual.
4) Use a torch to remove the spin closure on the suction line .
5) Use a torch to remove the check valve on the liquid line and press the chip of all supply ducts must be replaced before any tubing connections are made. FOLLOW THESE INSTRUCTIONS...
User Manual - Page 14
...4) Measure the supply temperature. Model
Static Pressure
0.1
CFM
0.15 0.2
2 Ton
High 900 877 856 Middle 630 614 599
0.25 0.3 0.35 0.4 0.5
835 816 795 766 737 585 571 556 536 515
3 Ton
High ------ 1240 1208 1177 ...of water column dry coil w/ filter) 4% reduction for differences encountered in installations. The CFM can allow for wet coil. This can be checked by the following method; (...
User Manual - Page 15
.... A certified service technician should be in a garage or where flammable vapors may cause serious personal injury or death. Unit should perform other physical damage. Drain pans and drain tubing were leak checked with water. Retrun and supply ducts are properly sized and tightened. Unit is cleaned or replaced. Tubing should be installed. Unit...
Haier HB6000VD1M22 Reviews
Do you have an experience with the Haier HB6000VD1M22 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Haier yet.
Earn 750 points for your review!