Service Manual
Page 1
Commercial Air Conditioning SERVICE MANUAL MULTI upgrade series Models Indoor: AB09CS1ERA AB12CS1ERA AB18CS1ERA AB24ES1ERA AC12CS1ERA AC18CS1ERA AC24CS1ERA AD09LS1ERA AD12LS1ERA AD18LS1ERA AD24LS1ERA Outdoor: 3U19FS1ERA 4U25HS1ERA 4U30HS1ERA 5U34HS1ERA z DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user z Universal indoor units for multi upgrade series, Unitary smart DC inverter and HAIER DAC split inverter type z High voltage communication, convenient wiring work z Multiple control types z 10℃ constant temperature control z Universal power ...
Commercial Air Conditioning SERVICE MANUAL MULTI upgrade series Models Indoor: AB09CS1ERA AB12CS1ERA AB18CS1ERA AB24ES1ERA AC12CS1ERA AC18CS1ERA AC24CS1ERA AD09LS1ERA AD12LS1ERA AD18LS1ERA AD24LS1ERA Outdoor: 3U19FS1ERA 4U25HS1ERA 4U30HS1ERA 5U34HS1ERA z DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user z Universal indoor units for multi upgrade series, Unitary smart DC inverter and HAIER DAC split inverter type z High voltage communication, convenient wiring work z Multiple control types z 10℃ constant temperature control z Universal power ...
Service Manual
Page 3
... for cool only type, refrigerant is R407C Design edition Product series: S stands for EASY STOCK Product appearance Cooling / Heating capacity,19=19000BTU/h Product type : "B" stands for cassette type, "C" stands for convertible type, "D" stands for duct, "S" stands for wall mounted type, "F" stands for console type, "U" stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Type of Conditioner Cooling Only Air T1 18 ℃~43℃ Heat pump -7℃~43℃ Electricity Heating...
... for cool only type, refrigerant is R407C Design edition Product series: S stands for EASY STOCK Product appearance Cooling / Heating capacity,19=19000BTU/h Product type : "B" stands for cassette type, "C" stands for convertible type, "D" stands for duct, "S" stands for wall mounted type, "F" stands for console type, "U" stands for outdoor of split unit Max. 1 to 3 1.2 Brief Introduction for T1,T2,T3 working condition Type of Conditioner Cooling Only Air T1 18 ℃~43℃ Heat pump -7℃~43℃ Electricity Heating...
Service Manual
Page 4
... upgrade series, unitary smart DC inverter and HAIER DAC split inverter type The indoor units are universal for design, sale, operation, and stock management. EASY STOCK is new concept brought by multiple types: infrared controller, wired controller, central controller. Also, the outdoor is with electronic expansion valve, which belongs to EASY STOCK series. Commercial Air Conditioner 1.4 Product features DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user The outdoor unit adopts DC inverter compressor and motor...
... upgrade series, unitary smart DC inverter and HAIER DAC split inverter type The indoor units are universal for design, sale, operation, and stock management. EASY STOCK is new concept brought by multiple types: infrared controller, wired controller, central controller. Also, the outdoor is with electronic expansion valve, which belongs to EASY STOCK series. Commercial Air Conditioner 1.4 Product features DC inverter technology, high energy efficiency, higher EER A+, energy saving for the user The outdoor unit adopts DC inverter compressor and motor...
Service Manual
Page 5
Commercial Air Conditioner on the operation panel. Central control function, if connected with a weekly timer Universal power supply for 50Hz and 60Hz The multi upgrade series adopts universal power supply for 50Hz and 60Hz, which is convenient for design. Much wider application. 1.5 Product lineup ¾Outdoor unit 220V/1/ (50/60Hz) Connection diagram Picture Max.indoor quantity Cooling capacity(Kbtu) 19 25 30 34 3 4 5 Indoor unit 220V/1/ (50/60Hz) SERIES...
Commercial Air Conditioner on the operation panel. Central control function, if connected with a weekly timer Universal power supply for 50Hz and 60Hz The multi upgrade series adopts universal power supply for 50Hz and 60Hz, which is convenient for design. Much wider application. 1.5 Product lineup ¾Outdoor unit 220V/1/ (50/60Hz) Connection diagram Picture Max.indoor quantity Cooling capacity(Kbtu) 19 25 30 34 3 4 5 Indoor unit 220V/1/ (50/60Hz) SERIES...
Service Manual
Page 6
... current (indoor + outdoor) A / A 11.3 11.3 Power facor(under rating power input) 99% 99% Fuse size (recommended size) A 16 Indoor units number 1~3 Model / Manufacture SNB130FGYMC-L1 / MGC Compressor Oil charge and type Type 500CC, FV 50S Twin Rotary (DC inverter) Winding resistance(at 20℃) Fan type × Number Ω 0.58 Axial × 1 Motor speed r/min Max. 860 Fan system Fan motor model Motor type ARW4403AS DC Outdoor unit Motor output/input power W 55/69 Air-flows (H/M/L) m³/h about 2000 Heat exchanger Type / Diameter Number of...
... current (indoor + outdoor) A / A 11.3 11.3 Power facor(under rating power input) 99% 99% Fuse size (recommended size) A 16 Indoor units number 1~3 Model / Manufacture SNB130FGYMC-L1 / MGC Compressor Oil charge and type Type 500CC, FV 50S Twin Rotary (DC inverter) Winding resistance(at 20℃) Fan type × Number Ω 0.58 Axial × 1 Motor speed r/min Max. 860 Fan system Fan motor model Motor type ARW4403AS DC Outdoor unit Motor output/input power W 55/69 Air-flows (H/M/L) m³/h about 2000 Heat exchanger Type / Diameter Number of...
Service Manual
Page 7
....Running current (indoor + outdoor) A / A 15.2 15.2 Power facor(under rating power input) 99% 99% Fuse size (recommended size) A 25 Indoor units number 2~4 Model / Manufacture TNB220FLHMC-L / MGC Compressor Oil charge and type Type 870CC / FV50S Twin Rotary (DC inverter) Winding resistance(at 20℃) Fan type × Number Ω 0.88 Axial × 1 Motor speed r/min Max. 860 Fan system Fan motor model Motor type EHDS80A100AS DC Outdoor unit Motor output/input power W 100/125 Air-flows (H/M/L) m³/h about 4000 Heat exchanger Type / Diameter Number of...
....Running current (indoor + outdoor) A / A 15.2 15.2 Power facor(under rating power input) 99% 99% Fuse size (recommended size) A 25 Indoor units number 2~4 Model / Manufacture TNB220FLHMC-L / MGC Compressor Oil charge and type Type 870CC / FV50S Twin Rotary (DC inverter) Winding resistance(at 20℃) Fan type × Number Ω 0.88 Axial × 1 Motor speed r/min Max. 860 Fan system Fan motor model Motor type EHDS80A100AS DC Outdoor unit Motor output/input power W 100/125 Air-flows (H/M/L) m³/h about 4000 Heat exchanger Type / Diameter Number of...
Service Manual
Page 8
... capacity Maximum power input (indoor + outdoor) Power source Max.Running current (indoor + outdoor) Power facor(under rating power input) Fuse size (recommended size) Indoor units number W W A W/W W W W W A / A A Cooling Heating 8100 9800 2220 2430 9.7 10.6 3.65 4.03 1500 1800 550 550 9800 10500 3800 3800 1PH, 220-230V~, 50/60Hz 16.5 16.5 99% 99% 25 2~4 Model / Manufacture TNB220FLHMC-L / MGC Compressor Fan system Oil charge and type Type Winding resistance(at 20℃) Fan type × Number Motor speed Fan motor model Motor type Ω...
... capacity Maximum power input (indoor + outdoor) Power source Max.Running current (indoor + outdoor) Power facor(under rating power input) Fuse size (recommended size) Indoor units number W W A W/W W W W W A / A A Cooling Heating 8100 9800 2220 2430 9.7 10.6 3.65 4.03 1500 1800 550 550 9800 10500 3800 3800 1PH, 220-230V~, 50/60Hz 16.5 16.5 99% 99% 25 2~4 Model / Manufacture TNB220FLHMC-L / MGC Compressor Fan system Oil charge and type Type Winding resistance(at 20℃) Fan type × Number Motor speed Fan motor model Motor type Ω...
Service Manual
Page 9
... 50/60Hz Max.Running current (indoor + outdoor) A / A 17.4 17.4 Power facor(under rating power input) Fuse size (recommended size) 99% 99% A 30 Indoor units number 2~5 Model / Manufacture TNB220FLHMC-L / MGC Compressor Oil charge and type Type 870CC / FV50S Twin Rotary (DC inverter) Winding resistance(at 20 ℃) Fan type × Number Ω 0.88 Axial × 1 Fan system Motor speed Fan motor model Motor type r/min Max. 900 EHDS80A100AS DC Outdoor unit Motor output/input power Air-flows (H/M/L) Heat exchanger Type / Diameter Number of 5U34HS1ERA+3*AS09CS1ERA...
... 50/60Hz Max.Running current (indoor + outdoor) A / A 17.4 17.4 Power facor(under rating power input) Fuse size (recommended size) 99% 99% A 30 Indoor units number 2~5 Model / Manufacture TNB220FLHMC-L / MGC Compressor Oil charge and type Type 870CC / FV50S Twin Rotary (DC inverter) Winding resistance(at 20 ℃) Fan type × Number Ω 0.88 Axial × 1 Fan system Motor speed Fan motor model Motor type r/min Max. 900 EHDS80A100AS DC Outdoor unit Motor output/input power Air-flows (H/M/L) Heat exchanger Type / Diameter Number of 5U34HS1ERA+3*AS09CS1ERA...
Service Manual
Page 10
...;mm 570×570×260 718×680×380 Drainage pipe (material , I.D./O.D.) mm PVC 26/32 Control type (Remote /wired) Remote or Wired Fresh air hole dimension mm 56 Electricity Heater kW NONE Noise level (H-M-L) dB(A) 40/36/32 Weight (Net / Shipping) kg / kg 17/20 Panel model (color) PB-700IB(WHITE) PIPING Panel Dimension External (L×W×H) mm×mm×mm...
...;mm 570×570×260 718×680×380 Drainage pipe (material , I.D./O.D.) mm PVC 26/32 Control type (Remote /wired) Remote or Wired Fresh air hole dimension mm 56 Electricity Heater kW NONE Noise level (H-M-L) dB(A) 40/36/32 Weight (Net / Shipping) kg / kg 17/20 Panel model (color) PB-700IB(WHITE) PIPING Panel Dimension External (L×W×H) mm×mm×mm...
Service Manual
Page 11
...;265 20/24 wired Fresh air hole dimension Electricity Heater Noise level (H-M-L) Weight (Net / Shipping) Refrigerant Type Pipe Liquid Gas Connecting Method mm kW dB(A) kg / kg mm mm NONE NONE 37/34/31 14/16 R410A φ6.35(1/4) φ9.52(3/8) flared PIPING Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB...
...;265 20/24 wired Fresh air hole dimension Electricity Heater Noise level (H-M-L) Weight (Net / Shipping) Refrigerant Type Pipe Liquid Gas Connecting Method mm kW dB(A) kg / kg mm mm NONE NONE 37/34/31 14/16 R410A φ6.35(1/4) φ9.52(3/8) flared PIPING Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB...
Service Manual
Page 12
... 570×570×260 718×680×380 Drainage pipe (material , I.D./O.D.) mm PVC 26/32 Control type (Remote /wired) Remote, YR-HD Fresh air hole dimension mm 56 Electricity Heater kW NONE Noise level (H-M-L) dB(A) 40/36/32 Weight (Net / Shipping) kg / kg 18.5/23 Panel model (color) PB-700IB(WHITE) PIPING Panel Dimension External (L×W×H) mm×mm×mm...
... 570×570×260 718×680×380 Drainage pipe (material , I.D./O.D.) mm PVC 26/32 Control type (Remote /wired) Remote, YR-HD Fresh air hole dimension mm 56 Electricity Heater kW NONE Noise level (H-M-L) dB(A) 40/36/32 Weight (Net / Shipping) kg / kg 18.5/23 Panel model (color) PB-700IB(WHITE) PIPING Panel Dimension External (L×W×H) mm×mm×mm...
Service Manual
Page 13
...×mm Package (L×W×H) mm×mm×mm Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater kW Noise level (H-M-L) dB(A) Weight (Net / Shipping) kg / kg Refrigerant Type Pipe Liquid Gas mm mm Connecting Method 1100/1025/825 0.09 650/550/450 inner grooved pipe/φ7 0.20 2-7 990×655×199 1150×750×...
...×mm Package (L×W×H) mm×mm×mm Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater kW Noise level (H-M-L) dB(A) Weight (Net / Shipping) kg / kg Refrigerant Type Pipe Liquid Gas mm mm Connecting Method 1100/1025/825 0.09 650/550/450 inner grooved pipe/φ7 0.20 2-7 990×655×199 1150×750×...
Service Manual
Page 14
... 20/24 wired, YR-E14 Fresh air hole dimension Electricity Heater Noise level (H-M-L) Weight (Net / Shipping) Refrigerant Type Pipe Liquid Gas Connecting Method mm kW dB(A) kg / kg mm mm NONE NONE 37/34/31 14/16 R410A φ6.35(1/4) φ9.52(3/8) flared PIPING Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃...
... 20/24 wired, YR-E14 Fresh air hole dimension Electricity Heater Noise level (H-M-L) Weight (Net / Shipping) Refrigerant Type Pipe Liquid Gas Connecting Method mm kW dB(A) kg / kg mm mm NONE NONE 37/34/31 14/16 R410A φ6.35(1/4) φ9.52(3/8) flared PIPING Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃...
Service Manual
Page 15
...;mm×mm Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater kW Noise level (H-M-L) dB(A) Weight (Net / Shipping) kg / kg Panel model (color) PIPING Panel Dimension External (L×W×H) mm×mm×mm Package (L×W×H) mm×mm×mm Weight (Net / Shipping) kg / kg Refrigerant Type Pipe Liquid Gas mm mm Connecting Method AB18CS1ERA cooling heating 5.0(1.8--5.8) 5.2(2.0---6.5) 0.71 / 1.8 1PH...
...;mm×mm Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Fresh air hole dimension mm Electricity Heater kW Noise level (H-M-L) dB(A) Weight (Net / Shipping) kg / kg Panel model (color) PIPING Panel Dimension External (L×W×H) mm×mm×mm Package (L×W×H) mm×mm×mm Weight (Net / Shipping) kg / kg Refrigerant Type Pipe Liquid Gas mm mm Connecting Method AB18CS1ERA cooling heating 5.0(1.8--5.8) 5.2(2.0---6.5) 0.71 / 1.8 1PH...
Service Manual
Page 17
...-60HZ Type × Number centrifugal fan X 2 Fan Speed(H-M-L) Fan motor output power r/min kW 700±30 / 540±30 / 400±30 50 Air-flow(H-M-L) m³/h 850/780/600 Static pressure Pa 25 Indoor unit Type / Diameter mm inner grooved pipe/φ7 Heat exchanger Total Area m² 0.34 Temp. scope ℃ 2-7 Dimension External (L×W×H) Package (L×W×H) Drainage pipe (material , I.D./O.D.) Control type (Remote /wired) mm...
...-60HZ Type × Number centrifugal fan X 2 Fan Speed(H-M-L) Fan motor output power r/min kW 700±30 / 540±30 / 400±30 50 Air-flow(H-M-L) m³/h 850/780/600 Static pressure Pa 25 Indoor unit Type / Diameter mm inner grooved pipe/φ7 Heat exchanger Total Area m² 0.34 Temp. scope ℃ 2-7 Dimension External (L×W×H) Package (L×W×H) Drainage pipe (material , I.D./O.D.) Control type (Remote /wired) mm...
Service Manual
Page 19
...*750*300 Drainage pipe (material , I.D./O.D.) mm PVC 18/20 Control type (Remote /wired) remote, YR-HD Noise level (H-M-L) dB(A) 48/46/44 Weight (Net / Shipping) kg / kg 28.3/34.3 Refrigerant Type R410A PIPING Pipe Liquid Gas mm mm 9.52 15.88 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB...
...*750*300 Drainage pipe (material , I.D./O.D.) mm PVC 18/20 Control type (Remote /wired) remote, YR-HD Noise level (H-M-L) dB(A) 48/46/44 Weight (Net / Shipping) kg / kg 28.3/34.3 Refrigerant Type R410A PIPING Pipe Liquid Gas mm mm 9.52 15.88 Connecting Method flared Norminal condition: indoor temperature (cooling): 27℃DB/19℃WB, indoor temperature (heating): 20℃DB Outdoor temperature(cooling): 35℃DB/24℃WB, outdoor temperature(heating): 7℃DB...
Service Manual
Page 20
... Indoor unit Type / Diameter mm Heat exchanger Total Area m² Temp. It is a sound pressure noise level. -20- scope ℃ Dimension External Package (L×W×H) (L×W×H) mm×mm×mm mm×mm×mm Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Noise level (H-M-L) dB(A) Weight (Net / Shipping) kg / kg Refrigerant Type PIPING Pipe Liquid Gas mm mm Connecting Method AD24LS1ERA cooling...
... Indoor unit Type / Diameter mm Heat exchanger Total Area m² Temp. It is a sound pressure noise level. -20- scope ℃ Dimension External Package (L×W×H) (L×W×H) mm×mm×mm mm×mm×mm Drainage pipe (material , I.D./O.D.) mm Control type (Remote /wired) Noise level (H-M-L) dB(A) Weight (Net / Shipping) kg / kg Refrigerant Type PIPING Pipe Liquid Gas mm mm Connecting Method AD24LS1ERA cooling...
Service Manual
Page 47
... other similar qualified person.The connecting cable must use special circuit , and wiring by wire cover. Wiring method of outdoor unit: Power line Remove the repair board of orbicular terminals For the connection wire with orbicular terminals, its wiring method is incorrect. Communication wire of air conditioner or the unit can not operate. 3. After connection, fasten wire cover B to its previous state. The wire cover shall press on the end of the terminal...
... other similar qualified person.The connecting cable must use special circuit , and wiring by wire cover. Wiring method of outdoor unit: Power line Remove the repair board of orbicular terminals For the connection wire with orbicular terminals, its wiring method is incorrect. Communication wire of air conditioner or the unit can not operate. 3. After connection, fasten wire cover B to its previous state. The wire cover shall press on the end of the terminal...
Service Manual
Page 49
... piping work; 2) Correct wiring work; 3) Correct match of indoor and outdoor unit; 4) Proper recharge of wiring error. CN2 CN3 Switch on the indoor unit or pipes, this number is indoor and outdoor communication error. Then power off the unit and power on again, the system will enter the operation of the wiring will be shown by , the unit starts for about how to read the LED display, refer to operate through the instruction manual. Please kindly explain to our customers...
... piping work; 2) Correct wiring work; 3) Correct match of indoor and outdoor unit; 4) Proper recharge of wiring error. CN2 CN3 Switch on the indoor unit or pipes, this number is indoor and outdoor communication error. Then power off the unit and power on again, the system will enter the operation of the wiring will be shown by , the unit starts for about how to read the LED display, refer to operate through the instruction manual. Please kindly explain to our customers...
Service Manual
Page 55
... indoor and outdoor units and install positively so that they cannot reach the unit. Under ceiling Indoor unit Decide the mounting position with the customer as follows: Left INDOOR UNIT (1) Install the indoor unit level on a strong wall, floor, ceiling which is not subject to vibration. (2) The inlet and outlet ports should not be obstructed: the air should be able to blow all over the room. (3) Install the unit near heat...
... indoor and outdoor units and install positively so that they cannot reach the unit. Under ceiling Indoor unit Decide the mounting position with the customer as follows: Left INDOOR UNIT (1) Install the indoor unit level on a strong wall, floor, ceiling which is not subject to vibration. (2) The inlet and outlet ports should not be obstructed: the air should be able to blow all over the room. (3) Install the unit near heat...