Manual
Page 2
... ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network......11 Network Security ...12 Users ...13 Services ...14 IPMI ...15 Time Setting ...17 Sessions ...18 LDAP ...19 Updates ...20 Utilities ...21 Server...
... ...5 Prerequisites on remote management PC 5 Install Java Tool ...5 Gigabyte Content Management Network Configuration 6 Using the Web UI...8 Gigabyte Content Management System Console Overview 9 Enter Gigabyte Content Management System Console 10 Properties ...10 Configuration ...11 Network......11 Network Security ...12 Users ...13 Services ...14 IPMI ...15 Time Setting ...17 Sessions ...18 LDAP ...19 Updates ...20 Utilities ...21 Server...
Manual
Page 7
Save and Exit. 5. Select Server Management. 3. Define BMC LAN Configuration to enable the console redirection function. 1. The BMC IP Address will appear on the IPv4 Address parameter. 6 Gigabyte Content Management Network Configuration Please follow the instruction to Dynamic or Static. 4. Go to BIOS setup menu. 2.
Save and Exit. 5. Select Server Management. 3. Define BMC LAN Configuration to enable the console redirection function. 1. The BMC IP Address will appear on the IPv4 Address parameter. 6 Gigabyte Content Management Network Configuration Please follow the instruction to Dynamic or Static. 4. Go to BIOS setup menu. 2.
Manual
Page 9
The web server shall support 4 concurrent connections Web-based GUI is supported on the following browsers: Microsoft Windows: • Internet Explorer 8 ~ 12 • Mozilla® Firefox® 2.0 or later Linux: Mozilla Firefox 2.0 or later 8 Using the Web UI The BMC firmware features an embedded web server, enabling users to connect to the BMC using an Internet browser (Microsoft® Internet Explorer™).
The web server shall support 4 concurrent connections Web-based GUI is supported on the following browsers: Microsoft Windows: • Internet Explorer 8 ~ 12 • Mozilla® Firefox® 2.0 or later Linux: Mozilla Firefox 2.0 or later 8 Using the Web UI The BMC firmware features an embedded web server, enabling users to connect to the BMC using an Internet browser (Microsoft® Internet Explorer™).
Manual
Page 10
... browser and type in lower-case characters. Enter the following values: Username: root Password: superuser The default user name and password are in your DHCP server. 2. When you log in , you change the root password. 9 A dialog box prompts you have full administrative powers. It is Intel C20x series chipset, please enter... log in using your identified IP. The IP address can be found using the root user name and password, you to enter Username and Password. 3. Gigabyte Content Management System Console Overview 1.
... browser and type in lower-case characters. Enter the following values: Username: root Password: superuser The default user name and password are in your DHCP server. 2. When you log in , you change the root password. 9 A dialog box prompts you have full administrative powers. It is Intel C20x series chipset, please enter... log in using your identified IP. The IP address can be found using the root user name and password, you to enter Username and Password. 3. Gigabyte Content Management System Console Overview 1.
Manual
Page 15
Services You can configure the web server parameters (such as, HTTP Port Number, HTTPS Port Number, and Timeout) on a remote computer. By default, the timeout is 1800 seconds. When you finish the configuration, click Apply Changes. 14
Services You can configure the web server parameters (such as, HTTP Port Number, HTTPS Port Number, and Timeout) on a remote computer. By default, the timeout is 1800 seconds. When you finish the configuration, click Apply Changes. 14
Manual
Page 18
...Requested Mode) to request an immediate clock set Requested Mode, or Daemon Mode in place. Operation Mode Configures the NTP Mode. Multiple NTP servers may be sent when click the Sync Time Now button. The Daemon Mode runs NTP daemon which sends a NTP request at approximately 5 ...minute intervals. Select Slew mode when you can Disable NTP, set . You can request an immediate clock synchronization with the NTP server; Select Step mode to configure the Network Time acquisition method. request will be specified to adjust the time smoothly over time if there are...
...Requested Mode) to request an immediate clock set Requested Mode, or Daemon Mode in place. Operation Mode Configures the NTP Mode. Multiple NTP servers may be sent when click the Sync Time Now button. The Daemon Mode runs NTP daemon which sends a NTP request at approximately 5 ...minute intervals. Select Slew mode when you can Disable NTP, set . You can request an immediate clock synchronization with the NTP server; Select Step mode to configure the Network Time acquisition method. request will be specified to adjust the time smoothly over time if there are...
Manual
Page 20
Click Apply Changes to access the LDAP server. LDAP LDAP screen allows download user list of LDAP server then create Gigabyte Content Management System Console user account from this list directly. Check the box below to enable LDAP authentication and enter the required information to save your changes. 19
Click Apply Changes to access the LDAP server. LDAP LDAP screen allows download user list of LDAP server then create Gigabyte Content Management System Console user account from this list directly. Check the box below to enable LDAP authentication and enter the required information to save your changes. 19
Manual
Page 23
Additionally you to power on/off/cycle the remote host system. To perform the power control operation, select the operation and click Apply Changes. 22 Server Information Power Control The Power Control allows you can see the remote power status.
Additionally you to power on/off/cycle the remote host system. To perform the power control operation, select the operation and click Apply Changes. 22 Server Information Power Control The Power Control allows you can see the remote power status.
Manual
Page 30
SMTP Set E-mail (SMTP) server IP address for sending alert notification to user. Check the SMTP Authentication Enabled box and enter the SMTP IP address, User Name, Password; After you can configure to specify the e-mail address, subject and message in the Email Settings. select the STARTTLS Mode and SASL Mode from the drop-down list. Email Settings If you want the alert to be sent by email, you finish the configuration, click Apply Change to save the settings. When you finish the configuration, click "Apply Changes". 29
SMTP Set E-mail (SMTP) server IP address for sending alert notification to user. Check the SMTP Authentication Enabled box and enter the SMTP IP address, User Name, Password; After you can configure to specify the e-mail address, subject and message in the Email Settings. select the STARTTLS Mode and SASL Mode from the drop-down list. Email Settings If you want the alert to be sent by email, you finish the configuration, click Apply Change to save the settings. When you finish the configuration, click "Apply Changes". 29
Manual
Page 33
Launch Java KVM Client Click Launch Java KVM Client to chapter: KVM Function Description 32 After clicking the button, a console appears as below: For KVM and remote redirection detail function description, please go to launch the redirection console and manage the server remotely.
Launch Java KVM Client Click Launch Java KVM Client to chapter: KVM Function Description 32 After clicking the button, a console appears as below: For KVM and remote redirection detail function description, please go to launch the redirection console and manage the server remotely.
Manual
Page 37
... full screen mode. This menu is large enough to completely display the targets desktop without an extra border or scrollbars. Will switch to the KVM server asking for a reference screen. View Menu Item View → Hide/Show Status Bar View →Refresh View →Full Screen View →Fit Resulting Action...
... full screen mode. This menu is large enough to completely display the targets desktop without an extra border or scrollbars. Will switch to the KVM server asking for a reference screen. View Menu Item View → Hide/Show Status Bar View →Refresh View →Full Screen View →Fit Resulting Action...
Manual
Page 6
Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. BMC command format table Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. GIGA -BYTE TECHNOLOGY CO., LTD. 2. Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
Preparation [1] Get BIOS image file "image.RBU" of target system. [2] Make sure target system BMC is live. [3] Get BMC IP address of target system. [4] Download TFTP service application for Linux client PC (Please users set up their own TFTP server.). [6] Get ipmitool. 2.2. BMC command format table Tftpd64.exe/Tftpd32.exe through BMC Command-line interface 2.1. GIGA -BYTE TECHNOLOGY CO., LTD. 2. Update BIOS through free download). [5] Setup TFTP server for Windows client PC (e.g.
Manual
Page 4
... Mode Options 93 2-3-7-3 PCH SATA Configuration 95 2-3-7-3-1 SATA Mode Options 98 2-3-7-4 USB Configuration 100 2-3-8 Miscellaneous Configuration 101 2-3-9 Server ME Configuration 102 2-3-10 Runtime Error Logging 103 2-3-10-1 Whea Setting...104 2-3-10-2 Memory Error Enabling 105 2-3-10-3 PCI/PCI Error... Enabling 106 2-4 Server Management Menu 107 2-4-1 System Event Log 109 2-4-2 View FRU Information 110 2-4-3 BMC network configuration 111 2-5 Security Menu 112 2-5-1...
... Mode Options 93 2-3-7-3 PCH SATA Configuration 95 2-3-7-3-1 SATA Mode Options 98 2-3-7-4 USB Configuration 100 2-3-8 Miscellaneous Configuration 101 2-3-9 Server ME Configuration 102 2-3-10 Runtime Error Logging 103 2-3-10-1 Whea Setting...104 2-3-10-2 Memory Error Enabling 105 2-3-10-3 PCI/PCI Error... Enabling 106 2-4 Server Management Menu 107 2-4-1 System Event Log 109 2-4-2 View FRU Information 110 2-4-3 BMC network configuration 111 2-5 Security Menu 112 2-5-1...
Manual
Page 19
Video Port The video in port allows connect to video in, which can also apply to this port for server management. RJ-45 LAN Ports (Gigabit Ethernet LAN Ports) The Gigabit Ethernet LAN port provides Internet connection at up to 1 Gbps data rate.... idenfication function. Hardware Installation - 19 - 1-5 Back Panel Connectors PS/2 Keyboard/Mouse Port Coonnect a PS/2 keyboard or mouse to video loop thru function. KVM Server Management 10/100/1000 MbpsLAN Port (Dedicated LAN Port) The LAN port provides Internet connection with data transfer speeds of the LAN port LEDs. Serial...
Video Port The video in port allows connect to video in, which can also apply to this port for server management. RJ-45 LAN Ports (Gigabit Ethernet LAN Ports) The Gigabit Ethernet LAN port provides Internet connection at up to 1 Gbps data rate.... idenfication function. Hardware Installation - 19 - 1-5 Back Panel Connectors PS/2 Keyboard/Mouse Port Coonnect a PS/2 keyboard or mouse to video loop thru function. KVM Server Management 10/100/1000 MbpsLAN Port (Dedicated LAN Port) The LAN port provides Internet connection with data transfer speeds of the LAN port LEDs. Serial...
Manual
Page 27
... Pin Hardware Installation - 27 - Pin No. For purchasing the optional USB bracket, please contact the local dealer. Typically, the HBA is a storage controller located inside a server, desktop, rack or workstation computer that interfaces with Hard disk drives (HDDs) to USB 3.0 specification.
... Pin Hardware Installation - 27 - Pin No. For purchasing the optional USB bracket, please contact the local dealer. Typically, the HBA is a storage controller located inside a server, desktop, rack or workstation computer that interfaces with Hard disk drives (HDDs) to USB 3.0 specification.
Manual
Page 41
...; Intel RC Setup This setup page includes all the submenu options for configuration of processor, network, North Bridge, South Bridge, and System event logs. Server Management Server additional features enabled/disabled setup menus. Security Change, set, or disable supervisor and user password. A supervisor password allows you to restrict access to...
...; Intel RC Setup This setup page includes all the submenu options for configuration of processor, network, North Bridge, South Bridge, and System event logs. Server Management Server additional features enabled/disabled setup menus. Security Change, set, or disable supervisor and user password. A supervisor password allows you to restrict access to...
Manual
Page 49
...: VT100/LINUX/XTERMR6/SCO/ESCN/VT400. Default setting is Always Enable. BIOS Setup Legacy OS Redirection Resolution (Note) On Legacy OS, the number of a Windows Server OS through a serial port.
...: VT100/LINUX/XTERMR6/SCO/ESCN/VT400. Default setting is Always Enable. BIOS Setup Legacy OS Redirection Resolution (Note) On Legacy OS, the number of a Windows Server OS through a serial port.
Manual
Page 102
ME Firmware Status #1/#2 Display ME Firmware status information. MCTP Bus Owner Configure MCTP Bus Owner. Current State (for ME Firmware) Display ME Firmware status error code. BIOS Setup - 102 - Recovery Firmware Version Display Recovery Firmware Version information. Error Code (for ME Firmware) Display ME Firmware current status information. 2-3-9 Server ME Configuration Greneral ME Configuration Operational Firmware Version Display Operational Firmware Version information. ME Firmware Features Display ME Firmware features information.
ME Firmware Status #1/#2 Display ME Firmware status information. MCTP Bus Owner Configure MCTP Bus Owner. Current State (for ME Firmware) Display ME Firmware status error code. BIOS Setup - 102 - Recovery Firmware Version Display Recovery Firmware Version information. Error Code (for ME Firmware) Display ME Firmware current status information. 2-3-9 Server ME Configuration Greneral ME Configuration Operational Firmware Version Display Operational Firmware Version information. ME Firmware Features Display ME Firmware features information.
Manual
Page 107
... is configurable when OS Watchdog Timer is Do Nothing. Options available: Do Nothing/Reset/Power Down. OS Wtd Timer Policy Configure OS Watchdog Timer Policy. 2-4 Server Management Menu FRB-2 Timer Enable/Disable FRB-2 timer (POST timer). Default setting is set to Enabled. Options available: Enabled/Disabled. Please note that this item...
... is configurable when OS Watchdog Timer is Do Nothing. Options available: Do Nothing/Reset/Power Down. OS Wtd Timer Policy Configure OS Watchdog Timer Policy. 2-4 Server Management Menu FRB-2 Timer Enable/Disable FRB-2 timer (POST timer). Default setting is set to Enabled. Options available: Enabled/Disabled. Please note that this item...
Manual
Page 116
Boot Option Priorities Boot Option #1/#2/#3#4 Press Enter to set the drive priority during POST. By default, the server searches for setup activation key. 65535(0xFFFF) means indefinite waiting." USB device BIOS Setup - 116 - Default setting is not bootable. Network device. 4. Boot Configuration Setup ...
Boot Option Priorities Boot Option #1/#2/#3#4 Press Enter to set the drive priority during POST. By default, the server searches for setup activation key. 65535(0xFFFF) means indefinite waiting." USB device BIOS Setup - 116 - Default setting is not bootable. Network device. 4. Boot Configuration Setup ...