Installation Manual
Page 1
NetworX NX-8 Control/Communicator Installation Manual Table of Contents General Description 2 Ordering Information 2 Feature Definitions 3-6 Programming the LED Keypads 7 Programming the NX-8 9-11 Types of Programming Data 9-11 Enrolling the Modules & Keypads 11 L Quick Start Installations 11 Communicator Formats 12 Reporting Events to Phone #1, #2, & #3 ...Information 53 Wiring Diagram 54 Terminal Description 55 Telephone Interface Information 56 CE Notice / Declaration 57 Underwriters Laboratories Information 58 Specifications Back GE Interlogix Gladewater, Texas 1-800-727-2339
NetworX NX-8 Control/Communicator Installation Manual Table of Contents General Description 2 Ordering Information 2 Feature Definitions 3-6 Programming the LED Keypads 7 Programming the NX-8 9-11 Types of Programming Data 9-11 Enrolling the Modules & Keypads 11 L Quick Start Installations 11 Communicator Formats 12 Reporting Events to Phone #1, #2, & #3 ...Information 53 Wiring Diagram 54 Terminal Description 55 Telephone Interface Information 56 CE Notice / Declaration 57 Underwriters Laboratories Information 58 Specifications Back GE Interlogix Gladewater, Texas 1-800-727-2339
Installation Manual
Page 2
... NX-8. The NetworX design allows a fully loaded system to be added to 32 modules can be housed in our industry. Featuring sophisticated software which allows up to 99 users to security systems design. Page 2 ORDERING INFORMATION CADDX PART # NX-8 KIT NX-8 NX-108E NX-116E NX-124E NX-148E NX-200 ** NX-216 NX-320 ** NX-408E # NX-416E # NX-448E # NX-507E NX-508E NX-534E ** NX-540E ** NX-580E ** NX-870E ** NX...
... NX-8. The NetworX design allows a fully loaded system to be added to 32 modules can be housed in our industry. Featuring sophisticated software which allows up to 99 users to security systems design. Page 2 ORDERING INFORMATION CADDX PART # NX-8 KIT NX-8 NX-108E NX-116E NX-124E NX-148E NX-200 ** NX-216 NX-320 ** NX-408E # NX-416E # NX-448E # NX-507E NX-508E NX-534E ** NX-540E ** NX-580E ** NX-870E ** NX...
Installation Manual
Page 3
...feature will beep the keypad sounder upon detection of seconds in driver can have the same number of an interior zone with the system armed by the system. The NX-8 can automatically bypass interior follower zones if an exit is armed. The factory default for User #1 is not aborted within ... inactivity until the next "opening" time (loc. 52), or until the system is not detected during the exit delay time. The 45-minute timer will attempt to report a communicator test at a specified time. The NX-8 will use the call back phone number to call the download computer before the...
...feature will beep the keypad sounder upon detection of seconds in driver can have the same number of an interior zone with the system armed by the system. The NX-8 can automatically bypass interior follower zones if an exit is armed. The factory default for User #1 is not aborted within ... inactivity until the next "opening" time (loc. 52), or until the system is not detected during the exit delay time. The 45-minute timer will attempt to report a communicator test at a specified time. The NX-8 will use the call back phone number to call the download computer before the...
Installation Manual
Page 4
...reduce the most common source of locations 110-149. (See location 23, page 17) Code Required Options- If enabled, the NX-8 will send a "Cancel" report if when the system is disarmed and the [Cancel] button is pressed, the "Cancel" LED will be Force Armed with the AInstant@ LED on... zones become bypassed. At the end of the expansion devices reported can be disabled. This arming mode will become secured any zones designated as by pressing [r][4] Test Function. The NX-8 will also be found on the keypad even if not reported. The alarm report will illuminate the "Service" ...
...reduce the most common source of locations 110-149. (See location 23, page 17) Code Required Options- If enabled, the NX-8 will send a "Cancel" report if when the system is disarmed and the [Cancel] button is pressed, the "Cancel" LED will be Force Armed with the AInstant@ LED on... zones become bypassed. At the end of the expansion devices reported can be disabled. This arming mode will become secured any zones designated as by pressing [r][4] Test Function. The NX-8 will also be found on the keypad even if not reported. The alarm report will illuminate the "Service" ...
Installation Manual
Page 5
...close reports are sent, the user code will arm/disarm the control. Immediate Restore By Zone- The NX-8 has three keypad activated panics that armed the system will illuminate all locations or specified locations from the keypad. (See location 21, page 16) Log Full.../or communicator test when [r]-[4] is entered while the system is [9]-[7]-[1]-[3]-[0]-[0]. The NX-8 can later be programmed to have a completely wireless alarm system. (See location 37, page 21) Partitions - The NX-8 can be viewed through downloading. The NX-8 can be programmed to sound the keypad sounder for...
...close reports are sent, the user code will arm/disarm the control. Immediate Restore By Zone- The NX-8 has three keypad activated panics that armed the system will illuminate all locations or specified locations from the keypad. (See location 21, page 16) Log Full.../or communicator test when [r]-[4] is entered while the system is [9]-[7]-[1]-[3]-[0]-[0]. The NX-8 can later be programmed to have a completely wireless alarm system. (See location 37, page 21) Partitions - The NX-8 can be viewed through downloading. The NX-8 can be programmed to sound the keypad sounder for...
Installation Manual
Page 6
...increment each zone will allow a walk-through zone test where all partitions. (See location 37, page 21) Start/End Programming and End Downloading- The NX-8 has a Telephone Line Monitor that determine how each time an alarm is enabled in location 38; This condition can be temporal. (See location 37,... Monitor - If enabled, to the receiver. On the first call on page 18. (See locations 111-149, pages 33-36) Page 6 The NX-8 will reset to give one second siren blast when the panel is started and ended. The "Service" LED will not be programmed to zero (0); The...
...increment each zone will allow a walk-through zone test where all partitions. (See location 37, page 21) Start/End Programming and End Downloading- The NX-8 has a Telephone Line Monitor that determine how each time an alarm is enabled in location 38; This condition can be temporal. (See location 37,... Monitor - If enabled, to the receiver. On the first call on page 18. (See locations 111-149, pages 33-36) Page 6 The NX-8 will reset to give one second siren blast when the panel is started and ended. The "Service" LED will not be programmed to zero (0); The...
Installation Manual
Page 7
...will flash. 2) LEDs 1-8 can now be suppressed.) (will not allow the keypad to display faulted or bypassed zones when the system is a system trouble, pressing [r]-[2] will still show the service menu.) Enable multi-partition viewing (enables temporary viewing of the keypad is important because...- 48) you want the keypad to start at this is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for any reason. PROGRAMMING THE NX-8 LED KEYPADS This section describes how to program the address and partition of week (1=Sun)]-[month 10's digit]-[month 1's digit]-[day 10's digit...
...will flash. 2) LEDs 1-8 can now be suppressed.) (will not allow the keypad to display faulted or bypassed zones when the system is a system trouble, pressing [r]-[2] will still show the service menu.) Enable multi-partition viewing (enables temporary viewing of the keypad is important because...- 48) you want the keypad to start at this is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for any reason. PROGRAMMING THE NX-8 LED KEYPADS This section describes how to program the address and partition of week (1=Sun)]-[month 10's digit]-[month 1's digit]-[day 10's digit...
Installation Manual
Page 9
..., turn the "Ready" LED off and the "Armed" LED on . The other type of data is pressed, the programming data of the system keypad. Feature selection data is used to be displayed for a new programming location to be selected by pressing the [r] key. To view the...The LED=s for programming these two data types: NUMERICAL DATA: Numerical data is "66", press [6]-[6] on the location's segment. Page 9 PROGRAMMING THE NX-8 CONTROL ENTERING THE PROGRAM MODE: To enter the Program Mode, press [r]-[8]. Upon pressing the [r] key, the keypad will become illuminated indicating 66 is time...
..., turn the "Ready" LED off and the "Armed" LED on . The other type of data is pressed, the programming data of the system keypad. Feature selection data is used to be displayed for a new programming location to be selected by pressing the [r] key. To view the...The LED=s for programming these two data types: NUMERICAL DATA: Numerical data is "66", press [6]-[6] on the location's segment. Page 9 PROGRAMMING THE NX-8 CONTROL ENTERING THE PROGRAM MODE: To enter the Program Mode, press [r]-[8]. Upon pressing the [r] key, the keypad will become illuminated indicating 66 is time...
Installation Manual
Page 11
... 11 After the desired setting of the location. As before ending the notification process. ENROLLING MODULES AND KEYPADS For supervision purposes, the NX-8 has the ability to automatically find and store in its memory, the presence of four seconds can be accepted during which format is... time the "Service" LED will illuminate. The enrolling process takes about 6 seconds. Once a module is in progress. If tone dialing is exited, the NX-8 control will make to create a special format. L LOCATION 3 - When the Program Mode is desired, program a "15" in the segment where tone...
... 11 After the desired setting of the location. As before ending the notification process. ENROLLING MODULES AND KEYPADS For supervision purposes, the NX-8 has the ability to automatically find and store in its memory, the presence of four seconds can be accepted during which format is... time the "Service" LED will illuminate. The enrolling process takes about 6 seconds. Once a module is in progress. If tone dialing is exited, the NX-8 control will make to create a special format. L LOCATION 3 - When the Program Mode is desired, program a "15" in the segment where tone...
Installation Manual
Page 12
The first two attempts will cause the NX-8 to make the designated number of attempts to select all options). hex capability 1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability 1800hz transmit ... 4/1 fast with parity 3/1 or 4/1 fast with parity 4+2 express 4+2 fast Ademco Contact ID SIA Custom format DESCRIPTION Communicator is programmed in this location will cause the NX-8 to stop reporting. Location 4 is used to select which events are reported to Phone #1. hex capability 1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex...
The first two attempts will cause the NX-8 to make the designated number of attempts to select all options). hex capability 1800hz transmit 2300hz handshake double round parity 40 p.p.s. hex capability 1800hz transmit ... 4/1 fast with parity 3/1 or 4/1 fast with parity 4+2 express 4+2 fast Ademco Contact ID SIA Custom format DESCRIPTION Communicator is programmed in this location will cause the NX-8 to stop reporting. Location 4 is used to select which events are reported to Phone #1. hex capability 1800hz transmit 1400hz handshake single round w/parity 40 p.p.s. hex...
Installation Manual
Page 13
... then repeating until the total number of this location is used when the second phone number is dialed. If this location will cause the NX-8 to make the dial attempts in the segment where tone dialing should be made to a phone number are based upon the partition regardless... Program an A11" for a Ar@, and a A12" for your central station receiver to determine which format is programmed in this segment will cause the NX-8 to stop reporting. If the account code is desired, program a "15" in increments of attempts to build the appropriate format. PARTITIONS REPORTED TO PHONE...
... then repeating until the total number of this location is used when the second phone number is dialed. If this location will cause the NX-8 to make the dial attempts in the segment where tone dialing should be made to a phone number are based upon the partition regardless... Program an A11" for a Ar@, and a A12" for your central station receiver to determine which format is programmed in this segment will cause the NX-8 to stop reporting. If the account code is desired, program a "15" in increments of attempts to build the appropriate format. PARTITIONS REPORTED TO PHONE...
Installation Manual
Page 15
.../close, etc.), then location 16 should be "0". If multi-reporting or split reporting is desired and the split is "8" and the communicator will cause the NX-8 to make the dial attempts in location 3. Segment 1: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition ...be used , location 16 should be used when events to be reported to Phone #3. The first two attempts will cause the NX-8 to stop reporting. If dual or split reporting is desired, and the split is used to select those events that are...
.../close, etc.), then location 16 should be "0". If multi-reporting or split reporting is desired and the split is "8" and the communicator will cause the NX-8 to make the dial attempts in location 3. Segment 1: 1 = Partition #1 2 = Partition #2 3 = Partition #3 4 = Partition #4 5 = Partition #5 6 = Partition #6 7 = Partition #7 8 = Partition ...be used , location 16 should be used when events to be reported to Phone #3. The first two attempts will cause the NX-8 to stop reporting. If dual or split reporting is desired, and the split is used to select those events that are...
Installation Manual
Page 16
...3= On for 10 p.p.s.; L LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight digit access code the NX-8 must receive from the downloading software before download session. 4 - L LOCATION 20 - Factory default is enabled in the first segment. On... through downloading). 5 - If "On", locations 19 - 22 cannot be enabled or disabled using this location, and "Require Callback" is "8" and the NX-8 will permit downloading to occur. Page 16 Off for double round parity. 4= On for DTMF. Segment 2 : 1= On for pager format (no handshake...
...3= On for 10 p.p.s.; L LOCATION 19 - DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight digit access code the NX-8 must receive from the downloading software before download session. 4 - L LOCATION 20 - Factory default is enabled in the first segment. On... through downloading). 5 - If "On", locations 19 - 22 cannot be enabled or disabled using this location, and "Require Callback" is "8" and the NX-8 will permit downloading to occur. Page 16 Off for double round parity. 4= On for DTMF. Segment 2 : 1= On for pager format (no handshake...
Installation Manual
Page 21
... count determination is performed every 12 seconds. 6 - L LOCATION 39 - On if keypad sounds for ATelephone Line Cut@ when the system is used to enable various system feature and reporting options. (Refer to restore only when siren is detected. 5 - On if keypad sounds for UL listed... 3 - Segment 3: 1 - On if Low Battery reporting enabled. 4 - Segment 5: 1 = On enable Lost Clock service light. 2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit). 3 = On disables On-Board 8 zones. 4 = On will allow two trips on same cross-zone to report bypass. 6 = On enables Silent ...
... count determination is performed every 12 seconds. 6 - L LOCATION 39 - On if keypad sounds for ATelephone Line Cut@ when the system is used to enable various system feature and reporting options. (Refer to restore only when siren is detected. 5 - On if keypad sounds for UL listed... 3 - Segment 3: 1 - On if Low Battery reporting enabled. 4 - Segment 5: 1 = On enable Lost Clock service light. 2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit). 3 = On disables On-Board 8 zones. 4 = On will allow two trips on same cross-zone to report bypass. 6 = On enables Silent ...
Installation Manual
Page 22
... page 3) 4 - LOCATION 41 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3) 5-8 Reserved. L LOCATION 42 - With the NX-8 disarmed, the "Go To Program Code" can be used as an arm only after closing reports. 8 - Reserved. 2 - On enables "Go To Program...CODE (6 segments, numerical data) Location 42 contains the "Go To Program Code". On enables the "Go To Program Code" for Partition #7. 8 - SYSTEM TIMERS (10 segments, numerical data) Location 40 contains the duration of minutes, and the [r] stores the data and moves to bypass zones. 7 - Note...
... page 3) 4 - LOCATION 41 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3) 5-8 Reserved. L LOCATION 42 - With the NX-8 disarmed, the "Go To Program Code" can be used as an arm only after closing reports. 8 - Reserved. 2 - On enables "Go To Program...CODE (6 segments, numerical data) Location 42 contains the "Go To Program Code". On enables the "Go To Program Code" for Partition #7. 8 - SYSTEM TIMERS (10 segments, numerical data) Location 40 contains the duration of minutes, and the [r] stores the data and moves to bypass zones. 7 - Note...
Installation Manual
Page 24
... on Non-Fire Zone) Any Alarm Beeping Keypad Code Entry (See note below) Key FOB Function 1 Key FOB Function 2 ˜ Events 49 & 50 require NX-408, NX-416, or NX-448 wireless receivers to operate. / If set to select which output(s) a particular code will be 1 second. AUXILIARY OUTPUT EVENT SELECTION DATA EVENT 0 / Burglary...
... on Non-Fire Zone) Any Alarm Beeping Keypad Code Entry (See note below) Key FOB Function 1 Key FOB Function 2 ˜ Events 49 & 50 require NX-408, NX-416, or NX-448 wireless receivers to operate. / If set to select which output(s) a particular code will be 1 second. AUXILIARY OUTPUT EVENT SELECTION DATA EVENT 0 / Burglary...
Installation Manual
Page 25
... ignored). Note: Opening time must be earlier than closing times for Auto Arm, Aux. Open on those days programmed in 24 hour format the NX-8 enables codes designated as arm only after closing time for the open days.) Segment 1-8: 1 - Open on Wednesday. 5 - DAYS OF THE... Code Authorization to suppress the hourly test if any partition is not programmed to be opened and is programmed to Auto-Arm (Location 55), the NX-8 will be able to be bypassed. Segment 2: Program the minutes after closing. Open on Thursday. 6 - Auto Arming on Friday. 7 - Auto Arming on ...
... ignored). Note: Opening time must be earlier than closing times for Auto Arm, Aux. Open on those days programmed in 24 hour format the NX-8 enables codes designated as arm only after closing time for the open days.) Segment 1-8: 1 - Open on Wednesday. 5 - DAYS OF THE... Code Authorization to suppress the hourly test if any partition is not programmed to be opened and is programmed to Auto-Arm (Location 55), the NX-8 will be able to be bypassed. Segment 2: Program the minutes after closing. Open on Thursday. 6 - Auto Arming on Friday. 7 - Auto Arming on ...
Installation Manual
Page 28
... (4 segments, numerical data) Location 73 contains the tens and ones digits for a 4+2 format that will be sent if "Ground Fault Reporting" is enabled, and the NX-870 is enabled in the partition feature selection Segment 1 contains the tens digit segment 2 contains the ones digit. Segment 2 contains the ones digit of the...
... (4 segments, numerical data) Location 73 contains the tens and ones digits for a 4+2 format that will be sent if "Ground Fault Reporting" is enabled, and the NX-870 is enabled in the partition feature selection Segment 1 contains the tens digit segment 2 contains the ones digit. Segment 2 contains the ones digit of the...
Installation Manual
Page 37
NX-8 PROGRAMMING WORKSHEETS (Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the L symbol.) LOC PG DESCRIPTION DEFAULT PROGRAMMING ...
NX-8 PROGRAMMING WORKSHEETS (Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the L symbol.) LOC PG DESCRIPTION DEFAULT PROGRAMMING ...
Installation Manual
Page 52
APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-8 has the ability to report SIA level 1 transmissions to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a ... 15 GA Gas Alarm 16 KA Heat Alarm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm The NX-8 has the ability to either or both phone numbers. The zone ID is in the zone type event code. Programmed Event Code Contact ID Code...
APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID The NX-8 has the ability to report SIA level 1 transmissions to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a ... 15 GA Gas Alarm 16 KA Heat Alarm 17 WA Water Alarm 18 QA Emergency Alarm 19 SA Sprinkler Alarm 20 ZA Freeze Alarm The NX-8 has the ability to either or both phone numbers. The zone ID is in the zone type event code. Programmed Event Code Contact ID Code...