Question posted by garyelliott204 on May 12th, 2023

Networx Nx-8 Transformer

where can i get a replacement for my old transformer. i found a honeywell 120v 60hz .30a. will it worrk?

Current Answers

Answer #1: Posted by SonuKumar on May 12th, 2023 9:26 AM
This answer was accepted by the poster of the original question.
SonuKumar

Member since:
May 9th, 2021

Points: 16,621,300
1,100
points
It's important to make sure that the replacement transformer you use is compatible with your GE NX-8 system. The Honeywell transformer you mentioned has the correct input voltage and frequency (120V 60Hz), but the amperage is lower (.30A) than what is typically required for the GE NX-8 transformer.

The transformer for the GE NX-8 system typically requires an output voltage of 16.5V AC and an amperage of 1.7A or higher. Therefore, it's important to find a replacement transformer that meets these specifications to ensure proper functioning of the system.

You can try checking with the manufacturer of the GE NX-8 system to see if they sell replacement transformers or if they can recommend a compatible one. Alternatively, you can search for replacement transformers that meet the specifications online or consult with a professional technician who can help you find a suitable replacement.

avaialble at amazon


Please respond to my effort to provide you with the best possible solution by using the "Acceptable Solution" and/or the "Helpful" buttons when the answer has proven to be helpful.

Regards,
Sonu
Your search handyman for all e-support needs!!

Related GE NX-8 Manual Pages

Installation Manual - Page 1

NetworX NX-8 Control/Communicator Installation Manual Table of Contents General Description 2 Ordering Information 2 Feature Definitions 3-6 Programming the LED Keypads 7 Programming the NX-8 9-11 Types of Programming Data 9-11 Enrolling the Modules & Keypads 11 L Quick Start Installations 11 Communicator Formats 12 Reporting Events to Phone #1, #2, & #3 12-15 Default ...
Installation Manual - Page 2

... comprehensive and fast SIA and Contact ID formats. Drawing on our experience in our industry. Featuring sophisticated software which allows up to 99 users to security systems design. GENERAL DESCRIPTION The NetworX NX-8 represents a new approach to interface with 48 zones, 8 partitions, and a host of the...
Installation Manual - Page 3

...the system armed by the system. All codes must be reported to the central station. The NX-8 will attempt to sending an alarm. If closing reports are sent, the user code will ... will extinguish. If enabled, the Cancel and/or Abort features will illuminate the "Service" LED on . The NX-8 will be stopped if a code is drawn from any device powered by pressing the [Bypass] key. (See...
Installation Manual - Page 4

... a specified time before creating an alarm. (See location 40, page 22) This feature is not secure, the "Ready" LED will sound if any entry/exit zone is used, a fault of the earth...button is not disarmed before creating an alarm. Cancel - If enabled, the NX-8 will become secured any zones designated as normal. The NX-8 can be enabled in multiple formats. The number of the exit delay, ...
Installation Manual - Page 5

...audible (sound siren). (See location 23, page 17) Keypad Sounder Control- If enabled, the NX-8 will sound the keypad, and the Keypad Panic can be partitioned into a maximum of eight ... Program" code is [9]-[7]-[1]-[3] when using a 4-digit code or, if the 6-digit option is [9]-[7]-[1]-[3]-[0]-[0]. The NX-8 can be 255. (See location 43, page 22) Quick Arm Feature - If used as they occur...
Installation Manual - Page 6

...are cut. (See location 37, page 21) Silent Exit Option - Siren Blast For Arming- The NX-8 has a ASiren Supervision@ circuit that monitors the voltage and current of a faulted phone line. The...answering machine, two telephone calls must have a Hayes 1200 Smart Modem or a Caddx 1200 module. The NX-8 has a Telephone Line Monitor that will be available. (See location 37, page 21) Zone Types...
Installation Manual - Page 7

... is pressed) Enable Armed Status Suppression (will automatically exit this mode at . 3) Enter [r] to save and exit. [r]-[9]-[3] Set keypad options 1) Enter [r]-[9]-[3] [program code]- PROGRAMMING THE NX-8 LED KEYPADS This section describes how to program the address and partition of week (1=Sun)]-[month 10's digit]-[month 1's digit]-[day 10's digit] [day 1's digit...
Installation Manual - Page 9

...After the last segment of their corresponding manuals. To exit before , you are now ready to the NX-8 are programmed through 8 are utilized, and the numeric equivalents of a location is a valid location... selected by entering its data. Example: 11 (B) or 14 (E). Page 9 To program the NX-8 Control Panel, enter [0]-[#]. If the location entered is programmed, pressing the [r] key will be...
Installation Manual - Page 11

... enter the data and automatically advance to the next segment of eight features associated with the NX-8, when communicating in location 18, to determine which time the "Service" LED will not ...attached to create a special format. L LOCATION 3 - ENROLLING MODULES AND KEYPADS For supervision purposes, the NX-8 has the ability to the data terminal. Program an A11" for a Ar@, and a A12" ...
Installation Manual - Page 12

...p.p.s. If dual or split reporting is desired, and the split is programmed in this segment, it will cause the NX-8 to make the dial attempts in Segment 2 of "0". EVENTS REPORTED TO PHONE # 1 (2 segments, feature selection...be left at the factory default of this segment will cause the NX-8 to Phone #1. Segment 2- hex capability 1800hz transmit 1400hz handshake single round w/parity 40...
Installation Manual - Page 13

...segments, numerical data) Segment 1, Dial attempts: Segment 1 of two. If this segment will cause the NX-8 to make the designated number of attempts to Phone #1 before ending the notification process. Segment 2, Phone...Backup Control: Programming a "0" in Segment 2 of this segment, it will cause the NX-8 to Phone #2 before setting the "Fail To Communicate" condition and stop trying to...
Installation Manual - Page 15

... used, location 16 should be "0". LOCATION 17 - If this location will cause the NX-8 to make the same number of "0". If dual or split reporting is based on ...which events are reported to Phone #3. Programming a "1" in Segment 1 is "8" and the communicator will cause the NX-8 to Phone #2, then repeating until the total number of two. EVENTS REPORTED TO PHONE #3 (2 segments, feature...
Installation Manual - Page 16

...will answer on page 3) Segment 1: 1 - L LOCATION 22 - If tone dialing is "8" and the NX-8 will hang up for 1800hz transmit; Page 16 Off for 1900hz. 2= On for DTMF. Segment 2 :... handshake; DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight digit access code the NX-8 must be changed through downloading) 6 - L LOCATION 21 - If "On", locations 19 - 22...
Installation Manual - Page 21

... 38 contains the number of trips during an arming cycle that are enabled. Segment 5: 1 = On enable Lost Clock service light. 2 = On enables Zone Doubling (requires NX-200 Zone Doubling Kit). 3 = On disables On-Board 8 zones. 4 = On will allow two trips on Fire. On if Fail To Communicate report enabled. 2 -
Installation Manual - Page 22

... Code" for Partition #5. 6 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3) 4 - If this option is enabled in minutes 1-255 minutes. With the NX-8 disarmed, the "Go To Program Code" can be used to be ignored. On enables "Go To Program Code" as a master arm/disarm code (can be...
Installation Manual - Page 55

...wiring diagram for a two-wire smoke detector using a 680 Ω E.O.L. approved transformer. Connect to 1 amp total current when added together. Connect positive wire of zone ...2500 WHEN CONNECTED TO NX-8 Wire Gauge 24 20 18 16 14 WHEN CONNECTED TO NX-320 Wire Gauge ...of devices (keypads + expanders) is positive. NETWORX KEYPAD MAXIMUM WIRE RUN (Note: These numbers are limited to 50mA...
Installation Manual - Page 57

... of Conformity Manufacturer's Name: Caddx Controls Manufacturer's Address: 1420 North Main Street Gladewater TX 75647 EU Representative: Interlogix Europe Product Identification Product: Model: Brand: NetworX NX-8 CADDX R&TTE Directive See EMC and LVD tests below EMC Directive EN50081-1 EN50130-4 EN55022 EN60950 EN61000-3-2 EN61000-3-3 LVD Directive EN 60950: 1999-4 3rd edition Means...
Installation Manual - Page 58

... 9000 - 2,12; For Canadian installations, the class II transformer secure tab shall not be set to 400 mA. ! The NetworX NX-8 panel is necessary to 140 mA. ! The keyswitch option...so on UL listed systems. ! FBI - For example, interior protection is needed for Home Health applications and each keypad must be disabled. ! MINIMUM SYSTEM CONFIGURATIONS FOR UL INSTALLATIONS ...
Installation Manual - Page 59

... will be positioned opposite the first (grooved edge up) and placed in the grooves of the modules. A screwdriver should connect this device to secure it in place. Replace only with the half-moon protrusion fits into the smaller hole (from the unit. 2. Installing the battery backwards may cause damage to tighten the...
Installation Manual - Page 61

... BUILT-IN SIREN DRIVER LOOP RESPONSE OPERATING TEMPERATURE LED KEYPAD Current Draw Zones Normal w/o Sounder Dimensions NX-148 LCD KEYPAD Current Draw w/o Sounder Dimensions METAL ENCLOSURE DIMENSION SHIPPING WEIGHT 16.5 VAC 25, 40, or 50 VA Transformer 12 VDC Regulated 500 mA 12 VDC Regulated 1 AMP 12 VDC Regulated 2 AMPS + Control Panel...

Similar Questions

Ge Networx Nx 148e Security System
Just bought a foreclosed home & it has two security system panels, one on each level. I do not k...
(Posted by Meadowsa 10 years ago)
Nx8v2?
How can I get a programming manual for a NX8V2?
(Posted by dkma1alarms 11 years ago)
Where Do The Resistors Go On An Nx-8 Unit?
Have a simple setup, two doors plus a motion detect. No fire or smoke detectors. Am confused as to...
(Posted by arlenpar 13 years ago)
Ask a New Question
Use the box below to post a new question about this GE product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

GE Manuals

Find free GE NX-8 - Security NetworX System manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

GE Reviews

View thousands of GE user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete GE customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed GE customer service rankings, employee comments and much more from our sister site.

GE Recalls

Find comprehensive GE recall information updated hourly on RecallOwl.com.