User Manual
Page 2
...-3287 800-547-2556 ORDERING INFORMATION PART # DESCRIPTION NX-8 KIT NX-8 NX-108E NX-116E NX-124E NX-148E NX-200 ** NX-216E NX-320E NX-408E # NX-416E # NX-448E # NX-507E NX-508E NX-534E ** NX-540E ** NX-591E ** NX-1192E NX-1208E NX-1248E NX-1308E NX-1316E NX-1324E NX-1448E Includes NX-8 Control, NX-108E LED Keypad, & 16.5V 40VA Transformer NX-8 Control Only 8 Zone LED Keypad 16 Zone LED Keypad 24 Zone LED Keypad Alphanumeric LCD Keypad Zone Doubling Kit (Includes 100 3.74k and 100...
...-3287 800-547-2556 ORDERING INFORMATION PART # DESCRIPTION NX-8 KIT NX-8 NX-108E NX-116E NX-124E NX-148E NX-200 ** NX-216E NX-320E NX-408E # NX-416E # NX-448E # NX-507E NX-508E NX-534E ** NX-540E ** NX-591E ** NX-1192E NX-1208E NX-1248E NX-1308E NX-1316E NX-1324E NX-1448E Includes NX-8 Control, NX-108E LED Keypad, & 16.5V 40VA Transformer NX-8 Control Only 8 Zone LED Keypad 16 Zone LED Keypad 24 Zone LED Keypad Alphanumeric LCD Keypad Zone Doubling Kit (Includes 100 3.74k and 100...
User Manual
Page 3
...Contents GENERAL DESCRIPTION ...4 Board Installation ...4 FEATURE DEFINITIONS ...5 PROGRAMMING THE LED KEYPADS...9 PROGRAMMING THE NX-8 CONTROL PANEL 11 TYPES OF PROGRAMMING DATA ...11 LOADING FACTORY DEFAULTS...13 ENROLLING MODULES AND KEYPADS...13 L QUICK START INSTALLATION ...13 CONTROL PANEL PROGRAMMING LOCATIONS 13 ...NUMBER 2...16 REPORTING EVENTS TO PHONE NUMBER 3...17 DEFAULT ZONE TYPES (Configurations) ...20 NX-8 PROGRAMMING WORKSHEETS ...38 APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA 52 APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID 53 APPENDIX 3 EXPANDER...
...Contents GENERAL DESCRIPTION ...4 Board Installation ...4 FEATURE DEFINITIONS ...5 PROGRAMMING THE LED KEYPADS...9 PROGRAMMING THE NX-8 CONTROL PANEL 11 TYPES OF PROGRAMMING DATA ...11 LOADING FACTORY DEFAULTS...13 ENROLLING MODULES AND KEYPADS...13 L QUICK START INSTALLATION ...13 CONTROL PANEL PROGRAMMING LOCATIONS 13 ...NUMBER 2...16 REPORTING EVENTS TO PHONE NUMBER 3...17 DEFAULT ZONE TYPES (Configurations) ...20 NX-8 PROGRAMMING WORKSHEETS ...38 APPENDIX 1 REPORTING FIXED CODES IN CONTACT ID AND SIA 52 APPENDIX 2 REPORTING ZONE CODES IN SIA OR CONTACT ID 53 APPENDIX 3 EXPANDER...
User Manual
Page 5
... a code for bypassing zones and/or initiating a download using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for User #1 is drawn from any device powered by pressing the [Bypass] key. (See location 23, page 19) Call Back- The NX-8 will enable the end user to activate relays, LED=s, etc. (See the terminal description on the keypad whenever too much...
... a code for bypassing zones and/or initiating a download using a 4-digit code, or [1]-[2]-[3]-[4]-[5]-[6] for User #1 is drawn from any device powered by pressing the [Bypass] key. (See location 23, page 19) Call Back- The NX-8 will enable the end user to activate relays, LED=s, etc. (See the terminal description on the keypad whenever too much...
User Manual
Page 6
...be programmed to sound the keypad and/or the siren. It is not secure, the "Ready" LED will verify a Fire alarm by pressing [r][4] Test Function. During the time between trips, the NX-8 can be programmed to send alarm and restore reports as soon as "cross zones" within a specified time ...steady (Fire) siren, Auxiliary 2 will illuminate the "Service" LED if a report fails to report an alarm after two or more trips on , the opening of the exit delay, these zones become bypassed. The NX-8 will sound the keypad, and the Keypad Panic can be 254. (See location 44, page 25) Dynamic...
...be programmed to sound the keypad and/or the siren. It is not secure, the "Ready" LED will verify a Fire alarm by pressing [r][4] Test Function. During the time between trips, the NX-8 can be programmed to send alarm and restore reports as soon as "cross zones" within a specified time ...steady (Fire) siren, Auxiliary 2 will illuminate the "Service" LED if a report fails to report an alarm after two or more trips on , the opening of the exit delay, these zones become bypassed. The NX-8 will sound the keypad, and the Keypad Panic can be 254. (See location 44, page 25) Dynamic...
User Manual
Page 7
... ability to restart the exit delay for 60 seconds and communicate a tamper signal to "2". Keypad Sounder Control- The NX-8 can be partitioned into a maximum of alarms. When a zone is detected in location 38; If enabled, the NX-8 will extinguish all LED=s. (See location 23, page 19) Local Programming Lockout- If this is detected on the...
... ability to restart the exit delay for 60 seconds and communicate a tamper signal to "2". Keypad Sounder Control- The NX-8 can be partitioned into a maximum of alarms. When a zone is detected in location 38; If enabled, the NX-8 will extinguish all LED=s. (See location 23, page 19) Local Programming Lockout- If this is detected on the...
User Manual
Page 8
... the answering machine answers, the panel will function and report. Each time a zone is a fire zone, then Zone 14 will sound. It will also be used on the LED keypad will illuminate and the chime will not be sent as Burglary (continuous). Otherwise ...LED keypad. Telephone Line Monitor - If the report is enabled, only the Telephone Line Restore will be available. (See location 37, page 23) Zone Types (Configurations) - Tone Sniff Answering Machine Defeat- The control panel will not be temporal. (See location 37, page 23) NOTE: For UL installations, do NOT disable. The NX...
... the answering machine answers, the panel will function and report. Each time a zone is a fire zone, then Zone 14 will sound. It will also be used on the LED keypad will illuminate and the chime will not be sent as Burglary (continuous). Otherwise ...LED keypad. Telephone Line Monitor - If the report is enabled, only the Telephone Line Restore will be available. (See location 37, page 23) Zone Types (Configurations) - Tone Sniff Answering Machine Defeat- The control panel will not be temporal. (See location 37, page 23) NOTE: For UL installations, do NOT disable. The NX...
User Manual
Page 9
... LED 1 2 3 4 5 6 7 8 Keypad Feature Enabled RESERVED. Silences the entry/exit sounder & chime only. The "Service" LED and the "Instant" LED will flash. 2) Enter [hour 10's digit]-[hour 1's digit]-[minutes 10's digit]-[minutes 1's digit] NX-8 Control 9 PROGRAMMING THE LED KEYPADS ... to LED keypad ONLY) 1) Enter [r] [9] [2] [program code]. 2) Enter the zone number (1 - 48) you want the keypad to start at. 3) Enter [r] to display faulted or bypassed zones when the system is a system trouble, pressing [r]-[2] will not allow the keypad to save and exit. [r]-[9]-[3] Set keypad options ...
... LED 1 2 3 4 5 6 7 8 Keypad Feature Enabled RESERVED. Silences the entry/exit sounder & chime only. The "Service" LED and the "Instant" LED will flash. 2) Enter [hour 10's digit]-[hour 1's digit]-[minutes 10's digit]-[minutes 1's digit] NX-8 Control 9 PROGRAMMING THE LED KEYPADS ... to LED keypad ONLY) 1) Enter [r] [9] [2] [program code]. 2) Enter the zone number (1 - 48) you want the keypad to start at. 3) Enter [r] to display faulted or bypassed zones when the system is a system trouble, pressing [r]-[2] will not allow the keypad to save and exit. [r]-[9]-[3] Set keypad options ...
User Manual
Page 10
...using the scroll keys you back to all blank codes. [r]-[9]-[8] Pressing [r]-[9]-[8] while the system is flashing to do a callback for NX1300 Series LED Keypad: The zone lights will illuminate steady. 3) Enter the new user code designated for . This will flash. 2) Enter the 2 digit user number (always ...- This moves you desire the end user to be required after [r]-[9]-[8] if enabled in location 24. 10 NX-8 Control LEDs 1-8 illuminate for each LED. The "Ready" LED will use the chart to exit the Assigning Authority Level Program. NOTE: Any master arm/disarm code can ...
...using the scroll keys you back to all blank codes. [r]-[9]-[8] Pressing [r]-[9]-[8] while the system is flashing to do a callback for NX1300 Series LED Keypad: The zone lights will illuminate steady. 3) Enter the new user code designated for . This will flash. 2) Enter the 2 digit user number (always ...- This moves you desire the end user to be required after [r]-[9]-[8] if enabled in location 24. 10 NX-8 Control LEDs 1-8 illuminate for each LED. The "Ready" LED will use the chart to exit the Assigning Authority Level Program. NOTE: Any master arm/disarm code can ...
User Manual
Page 11
... illuminate and the binary data for the first segment of this time, the five function LEDs (Stay, Chime, Exit, Bypass, & Cancel) will begin to the NX-8 are programmed through 8 are utilized, and the numeric equivalents of that segment awaiting a valid entry. EXITING THE PROGRAM ... in parenthesis. Pressing the [Exit] key will be displayed in the location will exit this process, the LED=s for zones 1 through the keypad, the module you are as for a particular segment, the keypad sounder will exit that location (2 + 64 = 66). One type of a location is programmed, pressing ...
... illuminate and the binary data for the first segment of this time, the five function LEDs (Stay, Chime, Exit, Bypass, & Cancel) will begin to the NX-8 are programmed through 8 are utilized, and the numeric equivalents of that segment awaiting a valid entry. EXITING THE PROGRAM ... in parenthesis. Pressing the [Exit] key will be displayed in the location will exit this process, the LED=s for zones 1 through the keypad, the module you are as for a particular segment, the keypad sounder will exit that location (2 + 64 = 66). One type of a location is programmed, pressing ...
User Manual
Page 12
..., Audible Keypad Panic and Keypad Auxiliary 2 are enabled. 12 NX-8 Control Returns to the "location" just programmed. PROGRAMMING EXAMPLE - For example: With the 1, 5, & 7 LEDs "on the numeric keypad that corresponds to the feature you wish to the next programming "location". Figure 1 (Numerical Data) } Zone 1 LED = 1 Zone 4 LED = 8 Data = 9 To change data in a segment, enter the data followed by [ ] } Zone 2 LED = 2 Zone 7 LED = 64...
..., Audible Keypad Panic and Keypad Auxiliary 2 are enabled. 12 NX-8 Control Returns to the "location" just programmed. PROGRAMMING EXAMPLE - For example: With the 1, 5, & 7 LEDs "on the numeric keypad that corresponds to the feature you wish to the next programming "location". Figure 1 (Numerical Data) } Zone 1 LED = 1 Zone 4 LED = 8 Data = 9 To change data in a segment, enter the data followed by [ ] } Zone 2 LED = 2 Zone 7 LED = 64...
User Manual
Page 13
... 13 ENROLLING MODULES AND KEYPADS For supervision purposes, the NX-8 has the ability to automatically find and store in the first segment. The enrolling process takes about 6 seconds. Once a module is enrolled, if it will turn the "Ready" LED off ) that the loading ...is programmed in location 18, to the data terminal. If tone dialing is 6 digits long, program all keypads, zone...
... 13 ENROLLING MODULES AND KEYPADS For supervision purposes, the NX-8 has the ability to automatically find and store in the first segment. The enrolling process takes about 6 seconds. Once a module is enrolled, if it will turn the "Ready" LED off ) that the loading ...is programmed in location 18, to the data terminal. If tone dialing is 6 digits long, program all keypads, zone...
User Manual
Page 18
...p.p.s.; Enter a number from the downloading software before download session. 4 - On locks out download section. (can only be viewed from the keypad; If "On", locations 19 - 22 cannot be changed through downloading. DOWNLOAD CALL BACK NUMBER (20 segments, numerical data) If a telephone number...two call back at auto test interval. DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight digit access code the NX-8 must be tone dialing, program an A15" in the segment where tone dialing should be changed through downloading) 7 - On enables ...
...p.p.s.; Enter a number from the downloading software before download session. 4 - On locks out download section. (can only be viewed from the keypad; If "On", locations 19 - 22 cannot be changed through downloading. DOWNLOAD CALL BACK NUMBER (20 segments, numerical data) If a telephone number...two call back at auto test interval. DOWNLOAD ACCESS CODE (8 segments, numerical data) Location 19 contains the eight digit access code the NX-8 must be tone dialing, program an A15" in the segment where tone dialing should be changed through downloading) 7 - On enables ...
User Manual
Page 19
..."enabled." 7 - Valid entries are 45-255 seconds. This is left blank, that will be used when a delay 1 zone type initiates an entry delay. NX-8 Control 19 L LOCATION 23 - If the feature selection location for any partition is the exit time that will be used ...an entry delay. This location contains 3 segments of these features can be enabled by partition. On enables the Keypad Aux 2 feature (MEDICAL). 8 - On enables the LED Extinguish feature. 2 - On enables Zone Tamper reporting. 6 - Segment 1, Entry time 1: Segment 2, Exit time 1: Segment 3, Entry time 2: ...
..."enabled." 7 - Valid entries are 45-255 seconds. This is left blank, that will be used when a delay 1 zone type initiates an entry delay. NX-8 Control 19 L LOCATION 23 - If the feature selection location for any partition is the exit time that will be used ...an entry delay. This location contains 3 segments of these features can be enabled by partition. On enables the Keypad Aux 2 feature (MEDICAL). 8 - On enables the LED Extinguish feature. 2 - On enables Zone Tamper reporting. 6 - Segment 1, Entry time 1: Segment 2, Exit time 1: Segment 3, Entry time 2: ...
User Manual
Page 20
...exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone creates an instant alarm whenever it is tripped and the Armed LED is entered at the keypad. This zone will bypass when the "Group Bypass" command is on a wireless transmitter. INTERIOR...-HOUR SILENT SUPERVISED- INSTANT WITH GROUP BYPASS ENABLED - This zone type can be used to enable tamper on a wireless transmitter. This zone type can be used to enable tamper on a wireless transmitter. 20 NX-8 Control This zone will automatically bypass if enabled in Segment 1 of a trip...
...exit delay will enable the Automatic Bypass or Instant mode if so programmed. This zone creates an instant alarm whenever it is tripped and the Armed LED is entered at the keypad. This zone will bypass when the "Group Bypass" command is on a wireless transmitter. INTERIOR...-HOUR SILENT SUPERVISED- INSTANT WITH GROUP BYPASS ENABLED - This zone type can be used to enable tamper on a wireless transmitter. This zone type can be used to enable tamper on a wireless transmitter. 20 NX-8 Control This zone will automatically bypass if enabled in Segment 1 of a trip...
User Manual
Page 23
...zones that the NX-8 will allow before bypassing a zone. On if siren blast at closing kissoff. 6 - On if Manual Communicator Test performed during an arming cycle that are enabled. On if End Download report enabled. 6 - NOTE: Do NOT disable for Immediate Restore by zone. On if keypad... Segment 3: Segment 4: Segment 5: 1 - On if Ground Fault Detection report enabled. 8 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data) Segment 1: 1 - On if keypad sounds for a Zone or Box Tamper. 8 - On if Aux. On if Expander Trouble reporting enabled. 1 - ...
...zones that the NX-8 will allow before bypassing a zone. On if siren blast at closing kissoff. 6 - On if Manual Communicator Test performed during an arming cycle that are enabled. On if End Download report enabled. 6 - NOTE: Do NOT disable for Immediate Restore by zone. On if keypad... Segment 3: Segment 4: Segment 5: 1 - On if Ground Fault Detection report enabled. 8 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data) Segment 1: 1 - On if keypad sounds for a Zone or Box Tamper. 8 - On if Aux. On if Expander Trouble reporting enabled. 1 - ...
User Manual
Page 26
...authorization, then LEDs 1- 4 correspond to that code activating outputs 1 - 4 respectively. (See programming the LED keypads on Non-Fire Zone) Any Alarm Beeping Keypad Code Entry (See note below) Key FOB Function 1 Key FOB Function 2 ˜ Events 49 & 50 require NX-408E, NX-416E, or NX-448E wireless ... Siren (Fire) 7 Any Siren 8 Any Bypass 9 AC Fail 10 Low Battery 11 / Duress 12 / Aux 1 Keypad Zone 13 / Aux 2 Keypad Zone 14 / Panic Keypad Zone 15 Keypad Tamper 16 / Autotest 17 Alarm Memory 18 Entry 19 Exit 20 Entry or Exit 21 Armed State 22 Disarmed State 23 ...
...authorization, then LEDs 1- 4 correspond to that code activating outputs 1 - 4 respectively. (See programming the LED keypads on Non-Fire Zone) Any Alarm Beeping Keypad Code Entry (See note below) Key FOB Function 1 Key FOB Function 2 ˜ Events 49 & 50 require NX-408E, NX-416E, or NX-448E wireless ... Siren (Fire) 7 Any Siren 8 Any Bypass 9 AC Fail 10 Low Battery 11 / Duress 12 / Aux 1 Keypad Zone 13 / Aux 2 Keypad Zone 14 / Panic Keypad Zone 15 Keypad Tamper 16 / Autotest 17 Alarm Memory 18 Entry 19 Exit 20 Entry or Exit 21 Armed State 22 Disarmed State 23 ...
User Manual
Page 29
...Sensor Missing Code". Segment 7 - Segment 1 contains the tens digit, segment 2 contains the ones digit. Any segment left as the zone number (i.e. 9 for a 4+2 format if the keypad "Auxiliary 2" (MEDICAL) is enabled in location 44. Partition #2, "Trouble Code". Partition #3, "Trouble Code". Segment 7 - Partition ...reported as "0" will always be sent as the zone number (i.e. 9 for zone 29). The zone ID will follow the Segment 1 selection. Partition #2, "Sensor Missing Code". Partition #7, "Sensor Missing Code". NX-8 Control 29 LOCATION 59 - TROUBLE COMMUNICATOR CODE,...
...Sensor Missing Code". Segment 7 - Segment 1 contains the tens digit, segment 2 contains the ones digit. Any segment left as the zone number (i.e. 9 for a 4+2 format if the keypad "Auxiliary 2" (MEDICAL) is enabled in location 44. Partition #2, "Trouble Code". Partition #3, "Trouble Code". Segment 7 - Partition ...reported as "0" will always be sent as the zone number (i.e. 9 for zone 29). The zone ID will follow the Segment 1 selection. Partition #2, "Sensor Missing Code". Partition #7, "Sensor Missing Code". NX-8 Control 29 LOCATION 59 - TROUBLE COMMUNICATOR CODE,...
User Manual
Page 30
... 1 contains the tens digit segment 2 contains the ones digit. Segment 2 contains the ones digit of the "Ground Fault Restore". 30 NX-8 Control Segment 4 contains the ones digit of the "Telephone Line Cut Reporting". AUX POWER OVERCURRENT/ AUX POWER OVERCURRENT RESTORE COMMUNICATOR CODES, ...(4 segments, numerical data) Location 70 contains the tens and ones digits for a 4+2 format that will be sent for a 4+2 format if the keypad "Multiple Code Entry" (Tamper) is enabled in location 37. Segment 2 contains the ones digit of the "Box Tamper Restore". BOX TAMPER / BOX...
... 1 contains the tens digit segment 2 contains the ones digit. Segment 2 contains the ones digit of the "Ground Fault Restore". 30 NX-8 Control Segment 4 contains the ones digit of the "Telephone Line Cut Reporting". AUX POWER OVERCURRENT/ AUX POWER OVERCURRENT RESTORE COMMUNICATOR CODES, ...(4 segments, numerical data) Location 70 contains the tens and ones digits for a 4+2 format that will be sent for a 4+2 format if the keypad "Multiple Code Entry" (Tamper) is enabled in location 37. Segment 2 contains the ones digit of the "Box Tamper Restore". BOX TAMPER / BOX...
User Manual
Page 32
...features per segment. Refer to report Cancels for partition 1 will be used . If all zones designated as Delay 1. If location 92 is enabled. START PROGRAM AND END PROGRAM COMMUNICATOR CODES... can be sent if "Start / End Programming Reporting" is left unprogrammed (all 6 segments. 32 NX-8 Control PARTITION 2 ENTRY EXIT TIMERS (4 segments, numerical data) Location 91 is 6 digits long program... code corresponding to the Phone number dialed will be sent to the user from the keypad of the account code. ACCOUNT CODE FOR PARTITION 2 (6 segments, numerical data) Location...
...features per segment. Refer to report Cancels for partition 1 will be used . If all zones designated as Delay 1. If location 92 is enabled. START PROGRAM AND END PROGRAM COMMUNICATOR CODES... can be sent if "Start / End Programming Reporting" is left unprogrammed (all 6 segments. 32 NX-8 Control PARTITION 2 ENTRY EXIT TIMERS (4 segments, numerical data) Location 91 is 6 digits long program... code corresponding to the Phone number dialed will be sent to the user from the keypad of the account code. ACCOUNT CODE FOR PARTITION 2 (6 segments, numerical data) Location...
User Manual
Page 33
...100 - There are A0", the entry and exit times for partition 1 will be enabled by partition. If all segments are 10-255 seconds. NX-8 Control 33 Each of the account code. If all segments are enabled in this location. LOCATION 95 - PARTITION 4 FEATURE AND REPORTING SELECTIONS ...features per segment. If all segments are visible to the user from the keypad of the system. LOCATION 96 - Valid entries are visible to the user from the keypad of these features can be used when a Delay 2 zone type initiates an entry delay. Refer to Location 23, Segments 1, 2, ...
...100 - There are A0", the entry and exit times for partition 1 will be enabled by partition. If all segments are 10-255 seconds. NX-8 Control 33 Each of the account code. If all segments are enabled in this location. LOCATION 95 - PARTITION 4 FEATURE AND REPORTING SELECTIONS ...features per segment. If all segments are visible to the user from the keypad of the system. LOCATION 96 - Valid entries are visible to the user from the keypad of these features can be used when a Delay 2 zone type initiates an entry delay. Refer to Location 23, Segments 1, 2, ...