Installation Instructions
Page 2
...22 ga. 1,800 ft./18 ga. 4000 ft. R Terminate each SuperBus 2000 8Z Input Module is 35 mA. For normally closed circuits, wire the resistor in ...the UltraGard cabinet. mercial applications) R 1/4-inch press-fit reed switch and magnet (not included) for cover tamper R 1/4-inch #6-32 self tapping screws (not included) for com- R Inside a SuperBus module cabinet (60-698). The module..., not at the zone input terminals. Mounting the Module ÁIG"42 To prevent damaging the panel or module, remove the panel AC...
...22 ga. 1,800 ft./18 ga. 4000 ft. R Terminate each SuperBus 2000 8Z Input Module is 35 mA. For normally closed circuits, wire the resistor in ...the UltraGard cabinet. mercial applications) R 1/4-inch press-fit reed switch and magnet (not included) for cover tamper R 1/4-inch #6-32 self tapping screws (not included) for com- R Inside a SuperBus module cabinet (60-698). The module..., not at the zone input terminals. Mounting the Module ÁIG"42 To prevent damaging the panel or module, remove the panel AC...
Installation Instructions
Page 4
... to either fire or burglary applications. ZONE COM ZONE 1 GND (BLK) BUS B (WHT) BUS A (GRN) +12 VDC (RED) ZONE 8 ZONE COMMON ZONE 7 ZONE 6 ZONE COMMON ZONE 5 ZONE 4 ZONE COMMON ZONE 3 ZONE 2 ZONE COMMON ZONE 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TO PANEL TO ZONE SUPERBUS TERMINALS INPUT OR CONNECTOR DEVICE (SEE TABLE) (SHARED COMMONS) 9712G03A.DSF Figure 7. General Module Wiring Table 4. Wire the module to either panel connector.) 4 1 2 3 4 5 6 7 8 9 10...
... to either fire or burglary applications. ZONE COM ZONE 1 GND (BLK) BUS B (WHT) BUS A (GRN) +12 VDC (RED) ZONE 8 ZONE COMMON ZONE 7 ZONE 6 ZONE COMMON ZONE 5 ZONE 4 ZONE COMMON ZONE 3 ZONE 2 ZONE COMMON ZONE 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 TO PANEL TO ZONE SUPERBUS TERMINALS INPUT OR CONNECTOR DEVICE (SEE TABLE) (SHARED COMMONS) 9712G03A.DSF Figure 7. General Module Wiring Table 4. Wire the module to either panel connector.) 4 1 2 3 4 5 6 7 8 9 10...
Installation Instructions
Page 8
... to radio communications. If this equipment in a residential area is encouraged to try to correct the interference by Interactive Technologies, Inc. ITI, Advent, UltraGard, and SuperBus are designed to provide reasonable protection against harmful interference when the equipment is no guarantee that interference will be determined by turning the equipment off... the limits for help. 2266 Second Street North North Saint Paul, MN 55109-2900 T: 651/777-2690 F: 651/779-4890 1-800-777-1415 www.itii.com ©2000 Interlogix™, Inc. These limits are trademarks of Interlogix, Inc.
... to radio communications. If this equipment in a residential area is encouraged to try to correct the interference by Interactive Technologies, Inc. ITI, Advent, UltraGard, and SuperBus are designed to provide reasonable protection against harmful interference when the equipment is no guarantee that interference will be determined by turning the equipment off... the limits for help. 2266 Second Street North North Saint Paul, MN 55109-2900 T: 651/777-2690 F: 651/779-4890 1-800-777-1415 www.itii.com ©2000 Interlogix™, Inc. These limits are trademarks of Interlogix, Inc.