Fluke 902 HVAC Clamp Meter Datasheet
Page 2
Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp Meter Holster • Rugged fabric holster includes flap for lead storage and built-in belt loop • Also used on Fluke 320 and 330...
Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp Meter Holster • Rugged fabric holster includes flap for lead storage and built-in belt loop • Also used on Fluke 320 and 330...
FE 902 Users Manual
Page 1
Printed in China. All product names are trademarks of their respective companies. ® 902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 © 2006-2007 Fluke Corporation. All rights reserved.
Printed in China. All product names are trademarks of their respective companies. ® 902 HVAC Clamp Meter Users Manual PN 2547887 May 2006 Rev. 1, 3/07 © 2006-2007 Fluke Corporation. All rights reserved.
FE 902 Users Manual
Page 7
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
FE 902 Users Manual
Page 8
902 Users Manual Contacting Fluke To contact Fluke, call one of the following telephone numbers: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or visit Fluke's Web site at : http://register.fluke.com 2 Register the Meter at : www.fluke.com.
902 Users Manual Contacting Fluke To contact Fluke, call one of the following telephone numbers: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or visit Fluke's Web site at : http://register.fluke.com 2 Register the Meter at : www.fluke.com.
FE 902 Users Manual
Page 9
XWRead First: Safety Information To ensure safe operation and service of the Meter, follow these instructions: • Read the Users Manual before use the Meter or test leads if they look damaged. • Use extreme caution when working alone so assistance can be damaged. • Never ... damage the Meter or the equipment under test. A "W Caution" statement identifies conditions and actions that could cause bodily harm or death. HVAC Clamp Meter Contacting Fluke Safety Information A "XW Warning" statement defines hazardous conditions and actions that could result in the Users...
XWRead First: Safety Information To ensure safe operation and service of the Meter, follow these instructions: • Read the Users Manual before use the Meter or test leads if they look damaged. • Use extreme caution when working alone so assistance can be damaged. • Never ... damage the Meter or the equipment under test. A "W Caution" statement identifies conditions and actions that could cause bodily harm or death. HVAC Clamp Meter Contacting Fluke Safety Information A "XW Warning" statement defines hazardous conditions and actions that could result in the Users...
FE 902 Users Manual
Page 10
Individual protective equipment must be made until the batteries are exposed. 4 902 Users Manual • Use caution when working with a damp cloth and mild detergent only. Such voltages pose a shock hazard. • Clean the case with voltages above 60 V ...
Individual protective equipment must be made until the batteries are exposed. 4 902 Users Manual • Use caution when working with a damp cloth and mild detergent only. Such voltages pose a shock hazard. • Clean the case with voltages above 60 V ...
FE 902 Users Manual
Page 11
See Users Manual. Contact Fluke or a qualified recycler for disposal. Risk of electric shock. Conforms to relevant European Union directives J Earth ground F DC (Direct Current) B AC (Alternating Current) ~ ; N10140 s Do not dispose of this manual. , May be used on the Meter or in this product as unsorted municipal waste. X Hazardous voltage. T Double insulation B Battery...
See Users Manual. Contact Fluke or a qualified recycler for disposal. Risk of electric shock. Conforms to relevant European Union directives J Earth ground F DC (Direct Current) B AC (Alternating Current) ~ ; N10140 s Do not dispose of this manual. , May be used on the Meter or in this product as unsorted municipal waste. X Hazardous voltage. T Double insulation B Battery...
FE 902 Users Manual
Page 12
COM CAT µAV 600V efu0001.eps Figure 1. 902 HVAC Clamp Meter Features 6 902 Users Manual Getting Acquainted with the Meter Refer to Figures 1 and 2 and Tables 1 and 2 to become more acquainted with the Meter's features.
COM CAT µAV 600V efu0001.eps Figure 1. 902 HVAC Clamp Meter Features 6 902 Users Manual Getting Acquainted with the Meter Refer to Figures 1 and 2 and Tables 1 and 2 to become more acquainted with the Meter's features.
FE 902 Users Manual
Page 16
Insert the test leads into the Meter. Turn the rotary switch to take the measurement. The Meter reading appears on the display. V 2. When the voltage drops below 30 V, Zdisappears. 10 902 Users Manual Using the Meter AC and DC Voltage Measurement To measure AC or DC voltage: 1. Use the test leads to . 3. Note When a measured voltage is above 30 V, Zappears on the display. The display reflects the chosen voltage mode. 4. Press A to choose AC or DC voltage.
Insert the test leads into the Meter. Turn the rotary switch to take the measurement. The Meter reading appears on the display. V 2. When the voltage drops below 30 V, Zdisappears. 10 902 Users Manual Using the Meter AC and DC Voltage Measurement To measure AC or DC voltage: 1. Use the test leads to . 3. Note When a measured voltage is above 30 V, Zappears on the display. The display reflects the chosen voltage mode. 4. Press A to choose AC or DC voltage.
FE 902 Users Manual
Page 18
To test a heating system flame rod (refer to the heating unit documentation for HVAC flame rod testing. Refer to Figure 3): 1. 902 Users Manual Microamps µA Measurement The µA dc (G) function on the Meter. 6. Using alligator clips, connect test leads between the gas-burner controller and the flame rod. 2. ...
To test a heating system flame rod (refer to the heating unit documentation for HVAC flame rod testing. Refer to Figure 3): 1. 902 Users Manual Microamps µA Measurement The µA dc (G) function on the Meter. 6. Using alligator clips, connect test leads between the gas-burner controller and the flame rod. 2. ...
FE 902 Users Manual
Page 20
Turn the rotary switch to the input jacks noting correct polarity of the probe. 2. The reading appears on the display. Connect the 80BK Integrated DMM Temperature Probe to F. 3. Press A to earth. 14 The display reflects the chosen temperature mode. 4. XW Warning To avoid possible electric shock DO NOT apply the probe tip to any conductor that is greater than 30 V ac, 42 V peak or 60 V dc to select °C or °F. Position the probe to take the measurement. Note To meet stated accuracy, the 80BK and Meter must be at the same temperature. 902 Users Manual 1.
Turn the rotary switch to the input jacks noting correct polarity of the probe. 2. The reading appears on the display. Connect the 80BK Integrated DMM Temperature Probe to F. 3. Press A to earth. 14 The display reflects the chosen temperature mode. 4. XW Warning To avoid possible electric shock DO NOT apply the probe tip to any conductor that is greater than 30 V ac, 42 V peak or 60 V dc to select °C or °F. Position the probe to take the measurement. Note To meet stated accuracy, the 80BK and Meter must be at the same temperature. 902 Users Manual 1.
FE 902 Users Manual
Page 22
... properly seated within the jaws, below the horizontal line located on the clamp. When measuring AC current, it is displayed while the capacitor discharges. 902 Users Manual Capacitance Turn off circuit power, then disconnect and discharge the capacitor before making current measurements. • Do not hold the Meter anywhere beyond the tactile...
... properly seated within the jaws, below the horizontal line located on the clamp. When measuring AC current, it is displayed while the capacitor discharges. 902 Users Manual Capacitance Turn off circuit power, then disconnect and discharge the capacitor before making current measurements. • Do not hold the Meter anywhere beyond the tactile...
FE 902 Users Manual
Page 24
... range. 2. Press Jto step through the minimum (MIN) and present readings. 4. When a new high or low is displayed. 3. Press Jto enter MIN MAX Mode. 902 Users Manual Backlight Press C to toggle the backlight on . MIN MAX Recording Mode The MIN MAX recording mode captures the minimum and maximum input values. K is displayed...
... range. 2. Press Jto step through the minimum (MIN) and present readings. 4. When a new high or low is displayed. 3. Press Jto enter MIN MAX Mode. 902 Users Manual Backlight Press C to toggle the backlight on . MIN MAX Recording Mode The MIN MAX recording mode captures the minimum and maximum input values. K is displayed...
FE 902 Users Manual
Page 26
902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning. Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. These solutions will react with a damp cloth and mild detergent. 20 W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning. Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. These solutions will react with a damp cloth and mild detergent. 20 W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
FE 902 Users Manual
Page 30
902 Users Manual General Specifications Operating Temperature -10 °C to +50 °C Storage Temperature -40 °C to +60 °C Operating Humidity Non condensing (< 10 °C) 90 % RH (10 ...
902 Users Manual General Specifications Operating Temperature -10 °C to +50 °C Storage Temperature -40 °C to +60 °C Operating Humidity Non condensing (< 10 °C) 90 % RH (10 ...