Fluke 902 HVAC Clamp Meter Datasheet
Page 1
Fluke 902 True-rms HVAC Clamp Meter Technical Data Heating, ventilation, air conditioning (HVAC) technicians require a service tool that can consistently keep up with True RMS technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their demands. N10140 Use the Fluke 902 to: • Capture flue gas temperatures • Conduct flame rod testing • Measure start and run motor capacitors...
Fluke 902 True-rms HVAC Clamp Meter Technical Data Heating, ventilation, air conditioning (HVAC) technicians require a service tool that can consistently keep up with True RMS technology and a CAT III 600 V rating, the Fluke 902 helps technicians do their demands. N10140 Use the Fluke 902 to: • Capture flue gas temperatures • Conduct flame rod testing • Measure start and run motor capacitors...
Fluke 902 HVAC Clamp Meter Datasheet
Page 2
... 98206 Fluke Europe B.V. All rights reserved. Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp Meter Holster • Rugged fabric holster includes flap for lead storage and built-in belt loop • Also used on Fluke 320 and 330 Series Clamp Meters TL223...
... 98206 Fluke Europe B.V. All rights reserved. Ordering Information Fluke-902 HVAC Clamp Meter Included AA alkaline batteries (2) Users manual (w/safety information) Soft carrying case TL75 Test Leads (1 pair) 80BK Integrated DMM Temperature Probe (1) Optional accessories H3 Clamp Meter Holster • Rugged fabric holster includes flap for lead storage and built-in belt loop • Also used on Fluke 320 and 330 Series Clamp Meters TL223...
FE 902 Users Manual
Page 2
... of purchase. Fluke Corporation P.O. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to extend any other warranty on Fluke's behalf. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. This warranty does not cover fuses, disposable batteries, or damage...
... of purchase. Fluke Corporation P.O. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to extend any other warranty on Fluke's behalf. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. This warranty does not cover fuses, disposable batteries, or damage...
FE 902 Users Manual
Page 3
Table of Contents Title Page Introduction 1 Contacting Fluke 2 Safety Information 3 Symbols 5 Getting Acquainted with the Meter 6 Using the Meter 10 AC and DC Voltage Measurement 10 Resistance and Continuity 11 Microamps µA Measurement 12 Temperature 13 Capacitance 16 AC Current Measurement 16 Backlight 18 MIN MAX Recording Mode 18 Display HOLD 19 Auto Off 19 Maintenance 20 Cleaning the Meter 20 Battery Replacement 21 Specifications 23 Electrical Specifications 23 General Specifications 24 i
Table of Contents Title Page Introduction 1 Contacting Fluke 2 Safety Information 3 Symbols 5 Getting Acquainted with the Meter 6 Using the Meter 10 AC and DC Voltage Measurement 10 Resistance and Continuity 11 Microamps µA Measurement 12 Temperature 13 Capacitance 16 AC Current Measurement 16 Backlight 18 MIN MAX Recording Mode 18 Display HOLD 19 Auto Off 19 Maintenance 20 Cleaning the Meter 20 Battery Replacement 21 Specifications 23 Electrical Specifications 23 General Specifications 24 i
FE 902 Users Manual
Page 5
Display Features 8 3. Battery Replacement 22 iii Temperature Measurement 15 5. List of Figures Figure Title Page 1. 902 HVAC Clamp Meter Features 6 2. Proper AC Current Measurement 17 6. Testing a Flame Rod 13 4. Display Features 9 List of Tables Table Title Page 1. 902 HVAC Clamp Meter Features 7 2.
Display Features 8 3. Battery Replacement 22 iii Temperature Measurement 15 5. List of Figures Figure Title Page 1. 902 HVAC Clamp Meter Features 6 2. Proper AC Current Measurement 17 6. Testing a Flame Rod 13 4. Display Features 9 List of Tables Table Title Page 1. 902 HVAC Clamp Meter Features 7 2.
FE 902 Users Manual
Page 7
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
902 Introduction The Fluke 902 is a hand-held battery-operated HVAC Clamp Meter ("the Meter") that measures: • AC current • DC current (up to 200 µA for flame rod testing) • AC and DC voltages • Capacitance • Resistance • Continuity • Temperature in both Celsius (°C) and Fahrenheit (°F) The Meter comes with: • Two AA alkaline batteries (installed) • Users Manual • Soft carrying case • TL75 Test Leads (one pair) • 80BK Integrated DMM Temperature Probe 1
FE 902 Users Manual
Page 8
Register the Meter at : www.fluke.com. 902 Users Manual Contacting Fluke To contact Fluke, call one of the following telephone numbers: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or visit Fluke's Web site at : http://register.fluke.com 2
Register the Meter at : www.fluke.com. 902 Users Manual Contacting Fluke To contact Fluke, call one of the following telephone numbers: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or visit Fluke's Web site at : http://register.fluke.com 2
FE 902 Users Manual
Page 9
... Clamp Meter Contacting Fluke Safety Information A "XW Warning" statement defines hazardous conditions and actions that could damage the Meter or the equipment under test. The Meter may be rendered. • Never use and follow these instructions: • Read the Users Manual before use the Meter on a circuit with the conductor could result in the Users Manual; XWRead First: Safety Information To ensure safe operation and service...
... Clamp Meter Contacting Fluke Safety Information A "XW Warning" statement defines hazardous conditions and actions that could damage the Meter or the equipment under test. The Meter may be rendered. • Never use and follow these instructions: • Read the Users Manual before use the Meter on a circuit with the conductor could result in the Users Manual; XWRead First: Safety Information To ensure safe operation and service...
FE 902 Users Manual
Page 10
... injury, replace the batteries as soon as the low battery indicator (B) appears. Individual protective equipment must be made until the batteries are changed. • Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1. • Adhere to prevent shock and arc blast injury where hazardous live conductors are exposed. 4 902 Users Manual • Use caution when working with a damp...
... injury, replace the batteries as soon as the low battery indicator (B) appears. Individual protective equipment must be made until the batteries are changed. • Do not hold the Meter anywhere beyond the tactile barrier, see Figure 1. • Adhere to prevent shock and arc blast injury where hazardous live conductors are exposed. 4 902 Users Manual • Use caution when working with a damp...
FE 902 Users Manual
Page 11
... Inspected and licensed by TÜV Product Services 5 X Hazardous voltage. Risk of electric shock. N10140 s Do not dispose of this manual. , May be used on the Meter or in this product as unsorted municipal waste. Conforms to relevant European Union directives J Earth ground F DC (Direct Current) B AC (Alternating Current) ~ ; Important information. Contact Fluke or a qualified recycler for disposal. HVAC...
... Inspected and licensed by TÜV Product Services 5 X Hazardous voltage. Risk of electric shock. N10140 s Do not dispose of this manual. , May be used on the Meter or in this product as unsorted municipal waste. Conforms to relevant European Union directives J Earth ground F DC (Direct Current) B AC (Alternating Current) ~ ; Important information. Contact Fluke or a qualified recycler for disposal. HVAC...
FE 902 Users Manual
Page 15
... voltage C Indicators for minimum and maximum recording mode D Display Hold is active E Volts F Amps °F - Degrees Celsius e - Microfarads DC - HVAC Clamp Meter Getting Acquainted with the Meter Number Table 2. Display Features Indication Battery indicator -The batteries are low and need to possible electric shock or personal injury, replace the batteries as soon as the battery indicator appears. Direct Current AC - Alternating Current 9 XWWarning: To...
... voltage C Indicators for minimum and maximum recording mode D Display Hold is active E Volts F Amps °F - Degrees Celsius e - Microfarads DC - HVAC Clamp Meter Getting Acquainted with the Meter Number Table 2. Display Features Indication Battery indicator -The batteries are low and need to possible electric shock or personal injury, replace the batteries as soon as the battery indicator appears. Direct Current AC - Alternating Current 9 XWWarning: To...
FE 902 Users Manual
Page 16
902 Users Manual Using the Meter AC and DC Voltage Measurement To measure AC or DC voltage: 1. The Meter reading appears on the display. Insert the test leads into the Meter. Press A to . 3. Note When a measured voltage is above 30 V, Zappears on the display. V 2. Turn the rotary switch to choose AC or DC voltage. When the voltage drops below 30 V, Zdisappears. 10 The display reflects the chosen voltage mode. 4. Use the test leads to take the measurement.
902 Users Manual Using the Meter AC and DC Voltage Measurement To measure AC or DC voltage: 1. The Meter reading appears on the display. Insert the test leads into the Meter. Press A to . 3. Note When a measured voltage is above 30 V, Zappears on the display. V 2. Turn the rotary switch to choose AC or DC voltage. When the voltage drops below 30 V, Zdisappears. 10 The display reflects the chosen voltage mode. 4. Use the test leads to take the measurement.
FE 902 Users Manual
Page 18
... rod (refer to the heating unit documentation for HVAC flame rod testing. Turn heating unit on and check the reading on the Meter to G. 4. Turn the heating unit off and locate the wire between the flame sensor probe and control-module wire. 5. Break this connection. 3. Refer to Figure 3): 1. Turn the rotary switch on the Meter. 6. Using alligator clips, connect test leads between the gas-burner...
... rod (refer to the heating unit documentation for HVAC flame rod testing. Turn heating unit on and check the reading on the Meter to G. 4. Turn the heating unit off and locate the wire between the flame sensor probe and control-module wire. 5. Break this connection. 3. Refer to Figure 3): 1. Turn the rotary switch on the Meter. 6. Using alligator clips, connect test leads between the gas-burner...
FE 902 Users Manual
Page 20
The reading appears on the display. Connect the 80BK Integrated DMM Temperature Probe to select °C or °F. Press A to the input jacks noting correct polarity of the probe. 2. Position the probe to earth. 14 XW Warning To avoid possible electric shock DO NOT apply the probe tip to any conductor that is greater than 30 V ac, 42 V peak or 60 V dc to take the measurement. 902 Users Manual 1. Note To meet stated accuracy, the 80BK and Meter must be at the same temperature. The display reflects the chosen temperature mode. 4. Turn the rotary switch to F. 3.
The reading appears on the display. Connect the 80BK Integrated DMM Temperature Probe to select °C or °F. Press A to the input jacks noting correct polarity of the probe. 2. Position the probe to earth. 14 XW Warning To avoid possible electric shock DO NOT apply the probe tip to any conductor that is greater than 30 V ac, 42 V peak or 60 V dc to take the measurement. 902 Users Manual 1. Note To meet stated accuracy, the 80BK and Meter must be at the same temperature. The display reflects the chosen temperature mode. 4. Turn the rotary switch to F. 3.
FE 902 Users Manual
Page 22
... necessary that currents moving in different directions will cancel each other out, so one wire must be properly seated within the jaws, below the horizontal line located on the clamp. The wire being measured should be sure to AC current (K). Turn the Meter's rotary switch to capacitance (L). 902 Users Manual Capacitance Turn off circuit power, then disconnect and discharge the capacitor...
... necessary that currents moving in different directions will cancel each other out, so one wire must be properly seated within the jaws, below the horizontal line located on the clamp. The wire being measured should be sure to AC current (K). Turn the Meter's rotary switch to capacitance (L). 902 Users Manual Capacitance Turn off circuit power, then disconnect and discharge the capacitor...
FE 902 Users Manual
Page 24
... backlight automatically turns off . Press Jto step through the minimum (MIN) and present readings. 4. When a new high or low is displayed. 5. To exit and erase stored readings, press Jfor at least two seconds. 18 MAX is displayed and the highest reading detected since entering MIN MAX is displayed. 3. To resume MIN MAX recording, press I . 902 Users Manual Backlight Press...
... backlight automatically turns off . Press Jto step through the minimum (MIN) and present readings. 4. When a new high or low is displayed. 5. To exit and erase stored readings, press Jfor at least two seconds. 18 MAX is displayed and the highest reading detected since entering MIN MAX is displayed. 3. To resume MIN MAX recording, press I . 902 Users Manual Backlight Press...
FE 902 Users Manual
Page 25
... the user. Auto Off is captured. His displayed and the reading is disabled during Min Max mode. In the Display HOLD mode, the Meter freezes the display. The Meter also beeps every 4 seconds and Hflashes to normal operation, press I. To disable Auto Off, hold J when turning the Meter on for the Meter to restart. Auto Off The Meter automatically turns off after 20 minutes. HVAC Clamp Meter Using the Meter Display...
... the user. Auto Off is captured. His displayed and the reading is disabled during Min Max mode. In the Display HOLD mode, the Meter freezes the display. The Meter also beeps every 4 seconds and Hflashes to normal operation, press I. To disable Auto Off, hold J when turning the Meter on for the Meter to restart. Auto Off The Meter automatically turns off after 20 minutes. HVAC Clamp Meter Using the Meter Display...
FE 902 Users Manual
Page 26
W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning. Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning. These solutions will react with a damp cloth and mild detergent. 20 902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter.
W Caution To avoid damaging the Meter, do not use aromatic hydrocarbons or chlorinated solvents for cleaning. Clean the instrument case with the plastics used in this manual should be performed only by qualified personnel. Cleaning the Meter XWWarning To avoid electrical shock, remove any input signals before cleaning. These solutions will react with a damp cloth and mild detergent. 20 902 Users Manual Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in the Meter.
FE 902 Users Manual
Page 27
... to the case bottom and tighten the screw. 21 Disconnect the test leads before replacing the batteries. Turn the rotary switch to possible electric shock or personal injury, replace the batteries as soon as the low battery indicator (B) appears. HVAC Clamp Meter Maintenance Battery Replacement XWWarning To avoid false readings that could lead to "OFF" and remove the test leads...
... to the case bottom and tighten the screw. 21 Disconnect the test leads before replacing the batteries. Turn the rotary switch to possible electric shock or personal injury, replace the batteries as soon as the low battery indicator (B) appears. HVAC Clamp Meter Maintenance Battery Replacement XWWarning To avoid false readings that could lead to "OFF" and remove the test leads...
FE 902 Users Manual
Page 31
Size (H X W X L) Weight Design Standards and Compliance Agency Approvals Over-voltage Category HVAC Clamp Meter Specifications 9.1 x 3.8 x 1.7 inches (240 x 80 x 40 mm) 1.1 lb (310 g) IEC 61010, IEC 61010-2032,CE P ) ; s N10140 600 V, CAT III per IEC 1010-1 Power Requirements CAT III equipment is designed to protect against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. Two AA Batteries, NEDA 15 A, IEC LR6 25
Size (H X W X L) Weight Design Standards and Compliance Agency Approvals Over-voltage Category HVAC Clamp Meter Specifications 9.1 x 3.8 x 1.7 inches (240 x 80 x 40 mm) 1.1 lb (310 g) IEC 61010, IEC 61010-2032,CE P ) ; s N10140 600 V, CAT III per IEC 1010-1 Power Requirements CAT III equipment is designed to protect against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. Two AA Batteries, NEDA 15 A, IEC LR6 25