Fluke 375 and 374 Clamp Meter Product Datasheet
Page 1
... on non-linear signals • Frequency measurement to 500 Hz with both jaw and iFlex™ (Fluke 375 only) • Resistance measurement to 60 kΩ (Fluke 375) or 6000 Ω (Fluke 374) with continuity detection • Min, max, average and inrush recording to capture variations automatically •... ability to 600 V and 600 A in noisy electrical environments while providing stable readings With true-rms ac voltage and current measurements, the Fluke 374 and 375 can read up to measure awkward sized conductors and improved wire access • CAT IV 600V, CAT III 1000 V safety ...
... on non-linear signals • Frequency measurement to 500 Hz with both jaw and iFlex™ (Fluke 375 only) • Resistance measurement to 60 kΩ (Fluke 375) or 6000 Ω (Fluke 374) with continuity detection • Min, max, average and inrush recording to capture variations automatically •... ability to 600 V and 600 A in noisy electrical environments while providing stable readings With true-rms ac voltage and current measurements, the Fluke 374 and 375 can read up to measure awkward sized conductors and improved wire access • CAT IV 600V, CAT III 1000 V safety ...
Fluke 375 and 374 Clamp Meter Product Datasheet
Page 2
... you do not need to change switch positions while taking a measurement • Three-year warranty • Soft carrying case Specifications Fluke 374 and 375 AC current via jaw AC current via iFlex™ (optional) DC current AC voltage DC voltage Resistance Frequency (375 ...IV 600 V Models Old model: Fluke 337 New model: Fluke 376 Old model: Fluke 336 New model: Fluke 375 New model: Fluke 374 Old model: Fluke 335 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 334 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 333 New model: Fluke 373 Feature Changes Includes all 337...
... you do not need to change switch positions while taking a measurement • Three-year warranty • Soft carrying case Specifications Fluke 374 and 375 AC current via jaw AC current via iFlex™ (optional) DC current AC voltage DC voltage Resistance Frequency (375 ...IV 600 V Models Old model: Fluke 337 New model: Fluke 376 Old model: Fluke 336 New model: Fluke 375 New model: Fluke 374 Old model: Fluke 335 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 334 New model: Fluke 374 New model: Fluke 373 Old model: Fluke 333 New model: Fluke 373 Feature Changes Includes all 337...
Fluke 374, 375, 376 Users Manual
Page 1
All rights reserved. Printed in China. Specifications are trademarks of their respective companies. 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 © 2010 Fluke Corporation. All product names are subject to change without notice.
All rights reserved. Printed in China. Specifications are trademarks of their respective companies. 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 © 2010 Fluke Corporation. All product names are subject to change without notice.
Fluke 374, 375, 376 Users Manual
Page 5
... Current Probe) that is included with the 376 (optional with the 374 and 375) expands the measurement range to 2500 A ac. The illustrations in this manual show the 376. 1 Introduction XWWarning Read "Safety Information" before you use the Meter. The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and...
... Current Probe) that is included with the 376 (optional with the 374 and 375) expands the measurement range to 2500 A ac. The illustrations in this manual show the 376. 1 Introduction XWWarning Read "Safety Information" before you use the Meter. The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and...
Fluke 374, 375, 376 Users Manual
Page 6
... download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 To register your product, visit http://register.fluke.com. 374, 375, 376 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888...
... download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 To register your product, visit http://register.fluke.com. 374, 375, 376 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888...
Fluke 374, 375, 376 Users Manual
Page 10
... to Fluke's website for the measurement application. • Clean the case and accessories with a damp cloth and mild detergent only. Symbols Symbol Meaning Symbol Meaning B AC (Alternating Current) J Earth ground F DC (Direct Current) Do not dispose of this product as ~ unsorted municipal waste. X Hazardous voltage P Conforms to European Union directives. 6 Table 1. 374...
... to Fluke's website for the measurement application. • Clean the case and accessories with a damp cloth and mild detergent only. Symbols Symbol Meaning Symbol Meaning B AC (Alternating Current) J Earth ground F DC (Direct Current) Do not dispose of this product as ~ unsorted municipal waste. X Hazardous voltage P Conforms to European Union directives. 6 Table 1. 374...