Fluke 289 Digital Multimeter Product Datasheet
Page 2
... intermittent problems or profiling loads 0.025 % basic dc accuracy allows you can graphically view logged readings on motor drives, in the field • Field upgradeable and expandable meter lets you make accurate voltage and frequency measurements on -board help screens • ... 50 ohm range with built-in the most demanding industrial settings. FlukeView Forms software compatible with 1 milliohm resolution, 10 mA source current "i" button provides instant on nonenergized motor. The Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture includes all the advanced...
... intermittent problems or profiling loads 0.025 % basic dc accuracy allows you can graphically view logged readings on motor drives, in the field • Field upgradeable and expandable meter lets you make accurate voltage and frequency measurements on -board help screens • ... 50 ohm range with built-in the most demanding industrial settings. FlukeView Forms software compatible with 1 milliohm resolution, 10 mA source current "i" button provides instant on nonenergized motor. The Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture includes all the advanced...
Fluke 287 and 289 Multimeter Users Manual
Page 5
... Setting Display Contrast 47 Setting the Meter's Language 47 Setting Date and Time 48 Setting Backlight and Auto Off Timeouts 48 Setting a Custom dBm Reference 48 Disabling and Enabling the Beeper 48 Enabling and Disabling the Smoothing Mode 49 Using Other Setup Options 49 Using Memory ...49 Storing Individual Measurement Data 49 Naming Saved Data 49 Viewing...
... Setting Display Contrast 47 Setting the Meter's Language 47 Setting Date and Time 48 Setting Backlight and Auto Off Timeouts 48 Setting a Custom dBm Reference 48 Disabling and Enabling the Beeper 48 Enabling and Disabling the Smoothing Mode 49 Using Other Setup Options 49 Using Memory ...49 Storing Individual Measurement Data 49 Naming Saved Data 49 Viewing...
Fluke 287 and 289 Multimeter Users Manual
Page 23
Controlling the Backlight If viewing the display becomes difficult in the highest range, at which point the range switches to indicate the Meter is 5 minutes. The default timeout is still collecting data. Note You cannot use a fixed range. In autorange, the Meter selects the lowest range to ...the righthand end of the bar graph, as the range indicator. Each additional press of R sets the Meter to enter the autoranging mode. recording mode, the time period is enabled. The Meter displays a message if the battery level will continue to flash to the lowest range. Pressing ...
Controlling the Backlight If viewing the display becomes difficult in the highest range, at which point the range switches to indicate the Meter is 5 minutes. The default timeout is still collecting data. Note You cannot use a fixed range. In autorange, the Meter selects the lowest range to ...the righthand end of the bar graph, as the range indicator. Each additional press of R sets the Meter to enter the autoranging mode. recording mode, the time period is enabled. The Meter displays a message if the battery level will continue to flash to the lowest range. Pressing ...
Fluke 287 and 289 Multimeter Users Manual
Page 29
...to allow saving the collected data. To extend battery life during peak record, the Meter enters a battery-saver mode after a period of time set for more information on the battery saver mode. See the "Setting Backlight and Auto Off Timeouts" section for the Auto Off feature. The summary ...information in the display freezes and the softkeys change function to be ended by pressing the softkey labeled Stop. Peak capture can be continued at this point. When viewing saved records, ...
...to allow saving the collected data. To extend battery life during peak record, the Meter enters a battery-saver mode after a period of time set for more information on the battery saver mode. See the "Setting Backlight and Auto Off Timeouts" section for the Auto Off feature. The summary ...information in the display freezes and the softkeys change function to be ended by pressing the softkey labeled Stop. Peak capture can be continued at this point. When viewing saved records, ...
Fluke 287 and 289 Multimeter Users Manual
Page 62
287/289 Users Manual softkeys labeled Prev and Next to select an item for... percentage of the value measured at the start of the measured signal and can be viewed through the Meter's Viewing Trend Data function. See the "Setting the Event Threshold Value" section later in less than one of the record. Each...default AutoHold threshold is made up a record can be caused by the activity of the record. Recording Measurement Data The Meter's record feature collects measurement information over the record's duration. A recording session is 4% of one second. Each record ...
287/289 Users Manual softkeys labeled Prev and Next to select an item for... percentage of the value measured at the start of the measured signal and can be viewed through the Meter's Viewing Trend Data function. See the "Setting the Event Threshold Value" section later in less than one of the record. Each...default AutoHold threshold is made up a record can be caused by the activity of the record. Recording Measurement Data The Meter's record feature collects measurement information over the record's duration. A recording session is 4% of one second. Each record ...
Fluke 287 and 289 Multimeter Users Manual
Page 64
... of recorded events is low. The maximum number of the battery level before pressing the Close softkey, the data is set to save the recording session, view the trend data (see the "Viewing Trend Data" section), or close the recording session. Starting a Recording Session Once the variables are...but the event counter continues to advance to move the menu selector next to scroll through the event threshold 54 values. 287/289 Users Manual The Meter allocates memory in the display and the green LED surrounding the power button (O) flashes. With the desired value selected, press ...
... of recorded events is low. The maximum number of the battery level before pressing the Close softkey, the data is set to save the recording session, view the trend data (see the "Viewing Trend Data" section), or close the recording session. Starting a Recording Session Once the variables are...but the event counter continues to advance to move the menu selector next to scroll through the event threshold 54 values. 287/289 Users Manual The Meter allocates memory in the display and the green LED surrounding the power button (O) flashes. With the desired value selected, press ...