Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet
Page 1
...; Wide 1000 V measurement range • True-rms for precise measurement of 8000 V assuring your hands with TL75 test leads, 9 V battery (installed), and manual. Fluke 73, 77, 175, 177 and 179 Digital Multimeters Versatile meters for alkaline. The 170 Series have the features needed to measurement Category III 1000 V and Category IV 600 V. Waveform...
...; Wide 1000 V measurement range • True-rms for precise measurement of 8000 V assuring your hands with TL75 test leads, 9 V battery (installed), and manual. Fluke 73, 77, 175, 177 and 179 Digital Multimeters Versatile meters for alkaline. The 170 Series have the features needed to measurement Category III 1000 V and Category IV 600 V. Waveform...
Fluke Multimeters - Anatomy of a High Quality Meter Application Note
Page 2
... outlets with high-quality, safety-rated accessories. Look for overvoltage installation categories. (50 V/150 V/300 V values not included.) ©2004 Fluke Corporation. Think of a meter and its weakest component. And a system is inactive. A cushioned, over-molded rubber design ensures a strong ...your new equipment. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Overvoltage Installation Category CAT I CAT I - But a failing battery is only as good as you get into an industrial setting, chances are you don't understand. Read the manual! Manuals actually are chock ...
... outlets with high-quality, safety-rated accessories. Look for overvoltage installation categories. (50 V/150 V/300 V values not included.) ©2004 Fluke Corporation. Think of a meter and its weakest component. And a system is inactive. A cushioned, over-molded rubber design ensures a strong ...your new equipment. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Overvoltage Installation Category CAT I CAT I - But a failing battery is only as good as you get into an industrial setting, chances are you don't understand. Read the manual! Manuals actually are chock ...
Fluke Multimeters - Detecting Intermittents Application Note
Page 2
...Series DMMs, can leave the DMM unattended while you will automatically switch to be whatever the ambient value is placed in signals moving to manual range by selecting the desired measurement function and set up to sense when a measured signal becomes unstable and when it . Advanced MIN ...MAX Recording functions The Fluke 189 True-rms Multimeter not only has the standalone MIN MAX AVG Recording feature described above , setup the meter by pressing the RANGE button...
...Series DMMs, can leave the DMM unattended while you will automatically switch to be whatever the ambient value is placed in signals moving to manual range by selecting the desired measurement function and set up to sense when a measured signal becomes unstable and when it . Advanced MIN ...MAX Recording functions The Fluke 189 True-rms Multimeter not only has the standalone MIN MAX AVG Recording feature described above , setup the meter by pressing the RANGE button...
Fluke Precision Multimeters - Understanding Specifications for Precision Multimeters Application Note
Page 2
... 9.9400 9.9600 9.9800 10.0000 10.0200 10.0400 10.0600 10.0800 Figure 1: A normal distribution with simple instruments like the Fluke 5700A or Fluke 9100. Adopting a normal distribution allows us to relate standard deviation to the percentage of readings that a reading will fall out of measurements,... like rulers and measuring cups.) Figure 1 shows a normal distribution curve centered at 10 V. design), not to any input in the DMM service manual. • The calibrator was within 2 standard deviations of the mean 99.7 % of the readings will determine how many standard deviations do we...
... 9.9400 9.9600 9.9800 10.0000 10.0200 10.0400 10.0600 10.0800 Figure 1: A normal distribution with simple instruments like the Fluke 5700A or Fluke 9100. Adopting a normal distribution allows us to relate standard deviation to the percentage of readings that a reading will fall out of measurements,... like rulers and measuring cups.) Figure 1 shows a normal distribution curve centered at 10 V. design), not to any input in the DMM service manual. • The calibrator was within 2 standard deviations of the mean 99.7 % of the readings will determine how many standard deviations do we...
FE 175,177,179 Users Manual
Page 1
Printed in USA. All rights reserved. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation.
Printed in USA. All rights reserved. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation.
FE 175,177,179 Users Manual
Page 3
Table of Contents Title Page Contacting Fluke ...1 "Warning" and "Caution" Statements 1 Unsafe Voltage...1 Test Lead Alert ...1 Battery Saver ("Sleep Mode 2 Terminals ...2 Rotary Switch Positions...2 Display ...3 MIN MAX AVG Recording Mode 4 Display HOLD and AutoHOLD Modes 4 YELLOW Button ...4 Display Backlight (Model 177 and 179 Only 4 Manual Ranging and Autoranging 5 Power-Up Options ...5 Making Basic Measurements...
Table of Contents Title Page Contacting Fluke ...1 "Warning" and "Caution" Statements 1 Unsafe Voltage...1 Test Lead Alert ...1 Battery Saver ("Sleep Mode 2 Terminals ...2 Rotary Switch Positions...2 Display ...3 MIN MAX AVG Recording Mode 4 Display HOLD and AutoHOLD Modes 4 YELLOW Button ...4 Display Backlight (Model 177 and 179 Only 4 Manual Ranging and Autoranging 5 Power-Up Options ...5 Making Basic Measurements...
FE 175,177,179 Users Manual
Page 4
... they appear damaged, or if the Meter is not operating properly. Read before opening the Meter case or battery door. see manual b Battery (Low battery when shown on the Meter, between the terminals or between any terminal and earth ground. ⇒ Use...IEC 61010-1. 54CJ Conforms to European Union directives F B DC/AC Earth ground Canadian Standards Association T Double insulated Important Information; Meter in this manual or the protection provided by TÜV (Technischer Überwachungs Verein) Product Services ; These voltages pose a shock hazard. ⇒ Replace the...
... they appear damaged, or if the Meter is not operating properly. Read before opening the Meter case or battery door. see manual b Battery (Low battery when shown on the Meter, between the terminals or between any terminal and earth ground. ⇒ Use...IEC 61010-1. 54CJ Conforms to European Union directives F B DC/AC Earth ground Canadian Standards Association T Double insulated Important Information; Meter in this manual or the protection provided by TÜV (Technischer Überwachungs Verein) Product Services ; These voltages pose a shock hazard. ⇒ Replace the...
FE 175,177,179 Users Manual
Page 5
... / DC voltage & current ♦ Diodes ♦ Resistance ♦ Continuity ♦ Voltage & current frequency ♦ Temperature (Model 179 only) ♦ Capacitance Contacting Fluke To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31 402-678-200 in Europe +81-3-3434-0181 in Japan...and actions that the test leads are designed to make a measurement with a 6000-count, 3 3/4-digit display and a bar graph. This manual applies to check that could cause bodily harm or death. These meters meet CAT III and CAT IV IEC 61010 standards. XW Warning Attempting to...
... / DC voltage & current ♦ Diodes ♦ Resistance ♦ Continuity ♦ Voltage & current frequency ♦ Temperature (Model 179 only) ♦ Capacitance Contacting Fluke To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31 402-678-200 in Europe +81-3-3434-0181 in Japan...and actions that the test leads are designed to make a measurement with a 6000-count, 3 3/4-digit display and a bar graph. This manual applies to check that could cause bodily harm or death. These meters meet CAT III and CAT IV IEC 61010 standards. XW Warning Attempting to...
FE 175,177,179 Users Manual
Page 6
... 3.00 mA to 1000 V. Input terminal for AC and DC current measurements to 400 mA (600 mA overload for 2 minutes maximum). Models 175, 177 & 179 Users Manual Battery Saver ("Sleep Mode") The Meter enters the "Sleep mode" and blanks the display if there is no function change or button press for 30..., hold down the YELLOW button while turning the Meter on at 250 Ω. Input terminal for voltage, continuity, resistance, diode, capacitance, frequency, and temperature (Model 179 only) measurements.
... 3.00 mA to 1000 V. Input terminal for AC and DC current measurements to 400 mA (600 mA overload for 2 minutes maximum). Models 175, 177 & 179 Users Manual Battery Saver ("Sleep Mode") The Meter enters the "Sleep mode" and blanks the display if there is no function change or button press for 30..., hold down the YELLOW button while turning the Meter on at 250 Ω. Input terminal for voltage, continuity, resistance, diode, capacitance, frequency, and temperature (Model 179 only) measurements.
FE 175,177,179 Users Manual
Page 7
... 10 15 No. 1 2 OSymbol s h3 K 4 Y 5 6 Amh MAX , MIN, AVG AIK02F.EPS Meaning Continuity test. Display No. mVA, Mke, kHz 8 DC, AC 9 b Direct current, alternating current. Manual Range The user selects the range. 13 ± Bar graph polarity. 14 0L 15 LEAd WThe input out of range. In the capacitance function, too...
... 10 15 No. 1 2 OSymbol s h3 K 4 Y 5 6 Amh MAX , MIN, AVG AIK02F.EPS Meaning Continuity test. Display No. mVA, Mke, kHz 8 DC, AC 9 b Direct current, alternating current. Manual Range The user selects the range. 13 ± Bar graph polarity. 14 0L 15 LEAd WThe input out of range. In the capacitance function, too...
FE 175,177,179 Users Manual
Page 8
.... turns off after 2 minutes. 4 To pause MIN MAX AVG recording without erasing stored values, press HOLD. Models 175, 177 & 179 Users Manual MIN MAX AVG Recording Mode The MIN MAX AVG recording mode captures the minimum and maximum input values, and calculates a running average of... the Display HOLD or AutoHOLD mode to select DC mA, DC A, Hz, temperature (Model 179 only), capacitance, diode test. Note For DC functions, accuracy is live. S Display Backlight (Model 177 and 179 Only) Press to activate AutoHOLD. Unstable or noisy readings will not be captured. lights. ...
.... turns off after 2 minutes. 4 To pause MIN MAX AVG recording without erasing stored values, press HOLD. Models 175, 177 & 179 Users Manual MIN MAX AVG Recording Mode The MIN MAX AVG recording mode captures the minimum and maximum input values, and calculates a running average of... the Display HOLD or AutoHOLD mode to select DC mA, DC A, Hz, temperature (Model 179 only), capacitance, diode test. Note For DC functions, accuracy is live. S Display Backlight (Model 177 and 179 Only) Press to activate AutoHOLD. Unstable or noisy readings will not be captured. lights. ...
FE 175,177,179 Users Manual
Page 9
.... S Disables automatic 2-minute backlight timeout. (Model 177 and 179 Only) 5 M Disables beeper. B (YELLOW) Disables automatic power-down the button indicated while turning the Meter from OFF to increment the range. Dampens display fluctuations of rapidly changing inputs by digital filtering. To exit Manual Range, press RANGE for 1 second or turn the Meter...
.... S Disables automatic 2-minute backlight timeout. (Model 177 and 179 Only) 5 M Disables beeper. B (YELLOW) Disables automatic power-down the button indicated while turning the Meter from OFF to increment the range. Dampens display fluctuations of rapidly changing inputs by digital filtering. To exit Manual Range, press RANGE for 1 second or turn the Meter...
FE 175,177,179 Users Manual
Page 10
Models 175, 177 & 179 Users Manual Making Basic Measurements The figures on the following pages show how to the Meter, disconnect circuit power and discharge all high-voltage capacitors before XW ...
Models 175, 177 & 179 Users Manual Making Basic Measurements The figures on the following pages show how to the Meter, disconnect circuit power and discharge all high-voltage capacitors before XW ...
FE 175,177,179 Users Manual
Page 12
... • AC current: below 5% of range to earth is why AC voltage and current ranges are plugged into the current terminals. Models 175, 177 & 179 Users Manual XW Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter: • Never attempt to make an in series, turn...
... • AC current: below 5% of range to earth is why AC voltage and current ranges are plugged into the current terminals. Models 175, 177 & 179 Users Manual XW Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter: • Never attempt to make an in series, turn...
FE 175,177,179 Users Manual
Page 13
... for a stable reading. AIK11F.EPS 9 It has an overload indicator ( ) to the right and a polarity indicator (±) to 1 kHz. ⇒ Select progressively lower ranges using manual ranging for all ranges. The trigger level is useful for making peak and null adjustments and for frequencies > 1 kHz. In frequency, the bar graph accurately...
... for a stable reading. AIK11F.EPS 9 It has an overload indicator ( ) to the right and a polarity indicator (±) to 1 kHz. ⇒ Select progressively lower ranges using manual ranging for all ranges. The trigger level is useful for making peak and null adjustments and for frequencies > 1 kHz. In frequency, the bar graph accurately...
FE 175,177,179 Users Manual
Page 14
Do not use abrasives or solvents. XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. Dirt or moisture in the terminals can affect readings. Test fuses as shown below. HOLD MINMAX RANGE 440 mA 11 A
Do not use abrasives or solvents. XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. Dirt or moisture in the terminals can affect readings. Test fuses as shown below. HOLD MINMAX RANGE 440 mA 11 A
FE 175,177,179 Users Manual
Page 16
... is 1.2 % + 2 for measurements to 100 % of range. 2. In the 9999 µF range for all models. 5. Models 175, 177 & 179 Users Manual Function Range 1 Resolution Accuracy ± ( [ % of Reading ] + [ Counts ] ) Model 175 Model 177 Model 179 AC Volts 2,3 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 (45 Hz to 500 Hz) 1.0 % + 3 (45...
... is 1.2 % + 2 for measurements to 100 % of range. 2. In the 9999 µF range for all models. 5. Models 175, 177 & 179 Users Manual Function Range 1 Resolution Accuracy ± ( [ % of Reading ] + [ Counts ] ) Model 175 Model 177 Model 179 AC Volts 2,3 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 (45 Hz to 500 Hz) 1.0 % + 3 (45...
FE 175,177,179 Users Manual
Page 18
.../100 A, 1000 V FAST Fuse Fused, 11 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum 20 A overload for high energy circuits. Models 175, 177 & 179 Users Manual Function Volts AC Volts DC mV/T Overload Protection 1 1000 V RMS 1000 V RMS 1000 V RMS2 Input Impedance (Nominal) > 10 MΩ < 100 pF > 10 MΩ 10...
.../100 A, 1000 V FAST Fuse Fused, 11 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum 20 A overload for high energy circuits. Models 175, 177 & 179 Users Manual Function Volts AC Volts DC mV/T Overload Protection 1 1000 V RMS 1000 V RMS 1000 V RMS2 Input Impedance (Nominal) > 10 MΩ < 100 pF > 10 MΩ 10...