Fluke 175 Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 175 manuals!
Problems with Fluke 175?

Ask a Question

Fluke 175 Videos

Fluke Multimeter Model 175
Duration: 6:25
Total Views: 968
Fluke Digital Multimeter Overview - 170, 175, 177, 179 Series
Duration: 4:27
Total Views: 49,371
Fluke 175 Digital Multimeter
Duration: :59
Total Views: 3,148

Popular Fluke 175 Manual Pages

Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet - Page 1

... and ventilation problems. They are protected to freeze the measurement display. The Fluke 179 comes with TouchHold® to measurement Category III 1000 V and Category IV 600 V. Battery life: 200 hours typical for maintenance, field service and bench repair. Includes holster and test leads. Waveform Normal sine wave Non True-rms meter Correct True-rms meter Correct Square...
FE 175,177,179 Users Manual - Page 1

Printed in USA. ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation. All rights reserved.
FE 175,177,179 Users Manual - Page 2

... or enforceability of repair/replacement parts if the product purchased in transit. Before making any provision of this warranty is held invalid or unenforceable by use outside of the product's specifications, or normal wear and tear of liability may not apply to that service center, with a description of a defective product purchased through a Fluke authorized sales outlet...
FE 175,177,179 Users Manual - Page 3

... AC and DC Voltage 6 Measuring Resistance ...6 Measuring Capacitance...6 Testing for Continuity...7 Measuring Temperature (Model 179 Only 7 Testing Diodes ...7 Measuring AC or DC Current 8 Understanding AC Zero Input Behavior of True RMS Meters 8 Measuring Frequency...9 Using the Bar Graph...9 Cleaning ...10 Testing the Fuses...10 Replacing the Battery and Fuses 10 Specifications ...11 i
FE 175,177,179 Users Manual - Page 4

...-voltage capacitors before opening the Meter case or battery door. These voltages pose a shock hazard. ⇒ Replace the battery as soon as specified in accordance with voltages above 30 V ac rms, 42 V ac peak, or 60 V dc. N10140 Underwriters Laboratories, Inc. see manual b Battery (Low battery when shown on the Meter, between the terminals or between...
FE 175,177,179 Users Manual - Page 5

... "the Meter") with a test lead in fixed-equipment installations at : register.fluke.com Models 175, 177 & 179 True RMS Multimeters "Warning" and "Caution" Statements A " XWWarning" identifies hazardous conditions and actions that could cause bodily harm or death. Unsafe Voltage To alert you to the presence of danger from the primary supply level (overhead or underground utility service...
FE 175,177,179 Users Manual - Page 6

...-coupled, true RMS, up to 99.99 kHz. To disable the Sleep mode, hold down the YELLOW button while turning the Meter on at 250 Ω. The Sleep mode is displayed. DC ... for 2 minutes maximum) and frequency measurements. Models 175, 177 & 179 Users Manual Battery Saver ("Sleep Mode") The Meter enters the "Sleep mode" and blanks the display if there is no function change or button ...
FE 175,177,179 Users Manual - Page 7

... switch is interrupted. Have Meter serviced. Invalid calibration data. In MIN MAX AVG mode, MIN MAX AVG recording is moved to or from the mA or A position. Low battery. Calibrate Meter. 3 Voltage ≥ 30 V, or voltage overload (OL) Display HOLD is enabled. Display freezes present reading. Then the Meter beeps and displays new reading. Manual Range The user selects the...
FE 175,177,179 Users Manual - Page 8

...displayed. ⇒ ⇒ h h Press MIN MAX to resume normal operation. turns off. ⇒ To exit and erase stored readings, press MIN MAX for 1 second or turn the rotary switch. Models 175, 177 & 179 Users Manual... minutes. 4 Then the Meter beeps and displays the new reading. ⇒...Display Backlight (Model 177 and 179 Only) Press to toggle the backlight on a rotary switch setting...
FE 175,177,179 Users Manual - Page 9

... a Power-Up Option, hold down ("Sleep mode"). R Enables "Smoothing" mode. S Disables automatic 2-minute backlight timeout. (Model 177 and 179 Only) 5 Power-Up Options are cancelled when the Meter is displayed. M Disables beeper. To enter the Manual Range mode, press RANGE. Manual Range is displayed. 1. B (YELLOW) Disables automatic power-down the button indicated while turning the...
FE 175,177,179 Users Manual - Page 10

... live lead; Warning To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all high-voltage capacitors before XW removing the... HOLD MIN MAX RANGE + _ + _ AIK03F.EPS + _ + 6 AIK04F.EPS AIK05F.EPS Models 175, 177 & 179 Users Manual Making Basic Measurements The figures on the following pages show how to the circuit or device, connect the...
FE 175,177,179 Users Manual - Page 12

... of True RMS Meters Unlike averaging meters, which can accurately measure only pure sinewaves, True RMS meters accurately measure distorted waveforms. Calculating True RMS converters require a certain level of 60 mA AC, or 3 mA AC HOLD MINMAX RANGE DC mA + + A CAT CAT AIK08F.EPS 8 They do not affect the specified AC accuracy above 5% of range. Models 175, 177 & 179 Users Manual XW...
FE 175,177,179 Users Manual - Page 14

Test fuses as shown below. HOLD MINMAX RANGE 440 mA 11 A Dirt or moisture in the terminals can affect readings. Models 175, 177 & 179 Users Manual Cleaning Wipe the case with a damp cloth and mild detergent. XW Testing the Fuses Warning To avoid electrical shock or injury, remove the test leads and any input signals before replacing the fuse. Do not use abrasives or solvents.
FE 175,177,179 Users Manual - Page 16

...Models 175, 177 & 179 Users Manual Function Range 1 Resolution Accuracy ± ( [ % of Reading ] + [ Counts ] ) Model 175 Model 177 Model...001 MΩ 0.01 MΩ Meter beeps at < 25 Ω, ... nF 0.01 µF 0.1 µF 1 µF 1.2 % + 2 1.2 % + 2 1.2 % + 2 10 % typical AC Amps 5 (True RMS) (45 Hz to 1 kHz) 60.00 mA 400.0 mA 6.000 A 10.00 A 0.01 mA 0.1 mA 0.001 A 0.01 A 1.5 % +...
FE 175,177,179 Users Manual - Page 18

... short circuit. 660 V for 30 seconds maximum 14 Models 175, 177 & 179 Users Manual Function Volts AC Volts DC mV/T Overload Protection 1 1000 V RMS 1000 V RMS 1000 V RMS2 Input Impedance (Nominal) > 10 M&#...Function mA A Overload Protection Fused, 44/100 A, 1000 V FAST Fuse Fused, 11 A, 1000 V FAST Fuse Overload 600 mA overload for 2 minutes maximum 20 A overload for high energy circuits...

Fluke 175 Reviews

Do you have an experience with the Fluke 175 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 175 Search Terms

The following terms are frequently used to search for Fluke 175 support:

Ask a New Question
Use the box below to post a new question about Fluke 175.
Manuals / Documents
Download any of our Fluke 175 manuals for free!

We have the following 2 documents available for the Fluke 175:
  • FE 175,177,179 Users Manual
  • Fluke 73, 77, 175, 177, and 179 Digital Multimeter Datasheet
Related Items
View other Fluke Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 175 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 175 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.