FE 1587-1577 Users Manual
Page 21
Err Insulation Multimeters Input Terminals Input Terminals Input terminals are shown in Figure 4 and described in Table 6. 1 3 2 4 Figure 4. CAL Invalid calibration data. Have the Meter serviced. EPPr Err Invalid EEProm data. Calibrate the Meter. Error Messages (cont.) Message Description diSc Meter cannot discharge a capacitor. Input Terminals bav04f.eps 11 Table 5.
Err Insulation Multimeters Input Terminals Input Terminals Input terminals are shown in Figure 4 and described in Table 6. 1 3 2 4 Figure 4. CAL Invalid calibration data. Have the Meter serviced. EPPr Err Invalid EEProm data. Calibrate the Meter. Error Messages (cont.) Message Description diSc Meter cannot discharge a capacitor. Input Terminals bav04f.eps 11 Table 5.
FE 1587-1577 Users Manual
Page 23
... the MIN MAX AVG mode was activated. Display shows PoFF until it detects a new stable reading. The Meter displays Cal and enters Calibration mode when the button is live. Unstable or noisy readings will not be used to determine if a circuit is released. Then the ... the rotary switch to activate AutoHold. Power-Up Options (cont.) Button Description G (Blue) H t Disables automatic power-off ("Sleep mode"). Starts the Calibration mode. Table 7. Sleep mode is also disabled while the Meter is released. Disables the beeper. MIN MAX AVG mode can be captured. The Meter tracks...
... the MIN MAX AVG mode was activated. Display shows PoFF until it detects a new stable reading. The Meter displays Cal and enters Calibration mode when the button is live. Unstable or noisy readings will not be used to determine if a circuit is released. Then the ... the rotary switch to activate AutoHold. Power-Up Options (cont.) Button Description G (Blue) H t Disables automatic power-off ("Sleep mode"). Starts the Calibration mode. Table 7. Sleep mode is also disabled while the Meter is released. Disables the beeper. MIN MAX AVG mode can be captured. The Meter tracks...
FE 1587-1577 Users Manual
Page 41
Input signal crest factor can be up to 3 up to 500 V, decreasing linearly to crest factor Conversions are ac-coupled and calibrated to the rms value of range. Insulation Multimeters Electrical Specifications 1587 and 1587T Low-Pass Filter Voltage Range 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 Hz...
Input signal crest factor can be up to 3 up to 500 V, decreasing linearly to crest factor Conversions are ac-coupled and calibrated to the rms value of range. Insulation Multimeters Electrical Specifications 1587 and 1587T Low-Pass Filter Voltage Range 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 Hz...
FE 1587-1577 Users Manual
Page 43
Conversions are ac-coupled and calibrated to 100 % of sine wave input. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to ... 60 mA [1] 1 kHz bandwidth. Insulation Multimeters Electrical Specifications DC and AC Current Measurement Range AC 45 Hz to crest factor Resolution 0.1 mA 0.01 mA Accuracy 1587 and 1587T ± (% of Rdg+Digits) + (1.5 % + 2) [1] + (1.5 % + 2) [1] Accuracy 1577 ± (% of Rdg+Digits) + (2 % + 2) [1] + (2 % + 2) [1] 0.1 mA 0.01 mA + (0.2 % + 2) + (0.2 % + 2) + (1.0 % + 2) + (1.0 % + 2) Burden Voltage (Typical) 2 mV/mA 2 mV/...
Conversions are ac-coupled and calibrated to 100 % of sine wave input. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to ... 60 mA [1] 1 kHz bandwidth. Insulation Multimeters Electrical Specifications DC and AC Current Measurement Range AC 45 Hz to crest factor Resolution 0.1 mA 0.01 mA Accuracy 1587 and 1587T ± (% of Rdg+Digits) + (1.5 % + 2) [1] + (1.5 % + 2) [1] Accuracy 1577 ± (% of Rdg+Digits) + (2 % + 2) [1] + (2 % + 2) [1] 0.1 mA 0.01 mA + (0.2 % + 2) + (0.2 % + 2) + (1.0 % + 2) + (1.0 % + 2) Burden Voltage (Typical) 2 mV/mA 2 mV/...