Fluke 116 Digital Multimeter Datasheet
Page 1
... humidity at 0 % to + 60 °C 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 400 hours typical, without backlight Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between...
... humidity at 0 % to + 60 °C 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 400 hours typical, without backlight Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Actual size R N10140 Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for 1 year after calibration, at operating temperatures of reading ] + [ counts ] ) Maximum voltage between...
Fluke 116 Digital Multimeter Datasheet
Page 2
... ac mV are shorted together. detects opens or shorts of range. Frequency is normal for ac current. Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and...true-rms meters to display non-zero readings when the test leads are disconnected from 1 % to 100 % of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 0.9 % + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Fluke. AC...
... ac mV are shorted together. detects opens or shorts of range. Frequency is normal for ac current. Fluke Corporation 116 HVAC Multimeter with Temperature and Microamps Included TL75 Test Leads, 80BK Integrated Temperature Probe, holster, User's manual and...true-rms meters to display non-zero readings when the test leads are disconnected from 1 % to 100 % of 500 µs or longer. 0.9 % + 2 0.9 % + 1 1.5 % + 2 0.9 % + 2 1.9 % + 2 1.9 % + 2 5 % + 20 10 % + 2 typical 1 % + 102 1 % + 182 Ordering information Fluke-116 HVAC Multimeter with Temperature and Microamps Fluke. AC...
Fluke 116 Users Manual
Page 3
... IV) based on the magnitude of a potentially hazardous voltage, the Y symbol is displayed when the Meter measures a voltage ≥30 V or a voltage overload (OL) condition. Register your Meter at register.fluke.com. True-rms Multimeter Introduction The Fluke Model 116, is unspecified. 1 When making frequency measurements >1 kHz, the Y symbol is a battery-powered, true-rms multimeter...
... IV) based on the magnitude of a potentially hazardous voltage, the Y symbol is displayed when the Meter measures a voltage ≥30 V or a voltage overload (OL) condition. Register your Meter at register.fluke.com. True-rms Multimeter Introduction The Fluke Model 116, is unspecified. 1 When making frequency measurements >1 kHz, the Y symbol is a battery-powered, true-rms multimeter...
Fluke 116 Users Manual
Page 4
...same voltage, category, and amperage ratings as the meter and that have the Meter serviced. • Do not apply more than the rated voltage, as specified in doubt, have been approved by measuring a known voltage. 116 Users Manual Safety Information A "XWWarning" statement ...identifies hazardous conditions and actions that could cause bodily harm or death. A "WCaution" statement identifies conditions and actions that could damage the Meter or the equipment under test. To ...
...same voltage, category, and amperage ratings as the meter and that have the Meter serviced. • Do not apply more than the rated voltage, as specified in doubt, have been approved by measuring a known voltage. 116 Users Manual Safety Information A "XWWarning" statement ...identifies hazardous conditions and actions that could cause bodily harm or death. A "WCaution" statement identifies conditions and actions that could damage the Meter or the equipment under test. To ...
Fluke 116 Users Manual
Page 6
D Y X Unsafe voltage. Display freezes present reading. 4 B R The Meter function is set to Diode Test C O Input is set to Continuity. 116 Users Manual Display 5 4 3 2 1 14 13 6 12 15 7 9 8 10 11 16 eeo02f.eps No. E K Display hold enabled. Symbol Meaning A s The Meter function is a negative value. Measured input voltage ≥ 30 V, or voltage overload condition (OL).
D Y X Unsafe voltage. Display freezes present reading. 4 B R The Meter function is set to Diode Test C O Input is set to Continuity. 116 Users Manual Display 5 4 3 2 1 14 13 6 12 15 7 9 8 10 11 16 eeo02f.eps No. E K Display hold enabled. Symbol Meaning A s The Meter function is a negative value. Measured input voltage ≥ 30 V, or voltage overload condition (OL).
Fluke 116 Users Manual
Page 7
H nµ°F°C mVµA MkΩ kHz Measurement units. The Meter selects the range for the selected range. Auto Auto ranging. N + Bar graph polarity O 0L W The input is measuring voltage or capacitiance with a low input... F M MIN MAX AVG mode enabled. I DC AC Direct current or alternating current J N Battery low warning. Manual Manual ranging. K 610000 mV Indicates the Meter's range selection. User sets the Meter's range. M Auto Volts The Meter is selected. 5 VWX Maximum, minimum, average or present reading displayed G LoZ The...
H nµ°F°C mVµA MkΩ kHz Measurement units. The Meter selects the range for the selected range. Auto Auto ranging. N + Bar graph polarity O 0L W The input is measuring voltage or capacitiance with a low input... F M MIN MAX AVG mode enabled. I DC AC Direct current or alternating current J N Battery low warning. Manual Manual ranging. K 610000 mV Indicates the Meter's range selection. User sets the Meter's range. M Auto Volts The Meter is selected. 5 VWX Maximum, minimum, average or present reading displayed G LoZ The...
Fluke 116 Users Manual
Page 8
... error. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be replaced before the Meter will operate. Internal error. B Input terminal for all measurements. The Meter must be repaired before it will operate. 6 116 Users Manual Terminals COM + 2 1 edy01f.eps No. Description A Common (return) terminal for measuring voltage, continuity, resistance...
... error. bAtt CAL Err EEPr Err F11Err Error Messages Battery must be replaced before the Meter will operate. Internal error. B Input terminal for all measurements. The Meter must be repaired before it will operate. 6 116 Users Manual Terminals COM + 2 1 edy01f.eps No. Description A Common (return) terminal for measuring voltage, continuity, resistance...
Fluke 116 Users Manual
Page 10
... maximum input values (ignoring overloads), and calculates a running average of all readings. When a new high or low is detected, the Meter beeps. • Put the Meter in the MIN MAX AVG mode. To exit and return to enter MIN MAX AVG mode. • Mand MAX are displayed and ...(MIN), average (AVG), and present readings. • To pause MIN MAX AVG recording without erasing stored values, press f. 116 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change when you override Autorange and select...
... maximum input values (ignoring overloads), and calculates a running average of all readings. When a new high or low is detected, the Meter beeps. • Put the Meter in the MIN MAX AVG mode. To exit and return to enter MIN MAX AVG mode. • Mand MAX are displayed and ...(MIN), average (AVG), and present readings. • To pause MIN MAX AVG recording without erasing stored values, press f. 116 Users Manual Battery Saver ("Sleep Mode") The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change when you override Autorange and select...
Fluke 116 Users Manual
Page 11
... . 3. True-rms Multimeter Power-Up Options Power-Up Options are canceled when you press qwhile in MIN MAX AVG or Display Hold, the Meter beeps twice, indicating an invalid operation, and the range does not change the range in the following pages show how to make basic measurements....leads to Autorange and Auto is displayed. 1. Manual is displayed when enabled. To exit Manual Range, press q for at least 1 second or turn the Meter off . LCAP is displayed when enabled. See page 14. PoFF is displayed when enabled. Power-Up Options To select a Power-Up Option, hold down...
... . 3. True-rms Multimeter Power-Up Options Power-Up Options are canceled when you press qwhile in MIN MAX AVG or Display Hold, the Meter beeps twice, indicating an invalid operation, and the range does not change the range in the following pages show how to make basic measurements....leads to Autorange and Auto is displayed. 1. Manual is displayed when enabled. To exit Manual Range, press q for at least 1 second or turn the Meter off . LCAP is displayed when enabled. See page 14. PoFF is displayed when enabled. Power-Up Options To select a Power-Up Option, hold down...
Fluke 116 Users Manual
Page 12
For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function. 116 Users Manual Measuring Resistance Testing for Continuity XWWarning eeo04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 eeo06f.eps Note The continuity function works best as a fast, convenient method to check for opens and shorts.
For maximum accuracy in making resistance measurements, use the Meter's resistance (e) function. 116 Users Manual Measuring Resistance Testing for Continuity XWWarning eeo04f.eps To avoid electric shock, injury, or damage to the Meter, disconnect circuit power and discharge all highvoltage capacitors before testing resistance, continuity, diodes, or capacitance. 10 eeo06f.eps Note The continuity function works best as a fast, convenient method to check for opens and shorts.
Fluke 116 Users Manual
Page 13
...DC eeo03f.eps Using Auto Volts Selection With the function switch in the l position, the Meter measures ac plus dc millivolts. edy18f.eps With the function switch in the x position, the Meter automatically selects a dc or ac voltage measurement based on the input applied between the + and... COM jacks. This function also sets the Meter's input impedance to approximately 3 kΩ to reduce the possibility of false...
...DC eeo03f.eps Using Auto Volts Selection With the function switch in the l position, the Meter measures ac plus dc millivolts. edy18f.eps With the function switch in the x position, the Meter automatically selects a dc or ac voltage measurement based on the input applied between the + and... COM jacks. This function also sets the Meter's input impedance to approximately 3 kΩ to reduce the possibility of false...
Fluke 116 Users Manual
Page 14
Turn the function switch to earth is > 600 V. • Use the proper switch position and range for your measurement. 116 Users Manual Measuring AC and DC Current WWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to $. 2. Turn heating unit on and record μA measurement. 12 Flame sensor probe Control Module eeo08f.eps To measure flame rectification circuits: 1. Connect the Meter between the flame sensor probe and the control module. 3.
Turn the function switch to earth is > 600 V. • Use the proper switch position and range for your measurement. 116 Users Manual Measuring AC and DC Current WWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the opencircuit potential to $. 2. Turn heating unit on and record μA measurement. 12 Flame sensor probe Control Module eeo08f.eps To measure flame rectification circuits: 1. Connect the Meter between the flame sensor probe and the control module. 3.
Fluke 116 Users Manual
Page 16
...range annunciator indicate the AC voltage present. 3. AC Voltage Frequency Hz Hz V The Meter measures the frequency of a signal by counting the number of the measured signal is turned off . 116 Users Manual Measuring Frequency XWWarning To avoid electrical shock, disregard the bar graph for ...frequencies >1 kHz. Frequency works with ghost voltage, hold qwhile turning on the Meter to turn the frequency measurement function on cables with ...
...range annunciator indicate the AC voltage present. 3. AC Voltage Frequency Hz Hz V The Meter measures the frequency of a signal by counting the number of the measured signal is turned off . 116 Users Manual Measuring Frequency XWWarning To avoid electrical shock, disregard the bar graph for ...frequencies >1 kHz. Frequency works with ghost voltage, hold qwhile turning on the Meter to turn the frequency measurement function on cables with ...
Fluke 116 Users Manual
Page 17
... 600 μA The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to a Fluke catalog or contact your current probe. Make sure the Meter has the correct function, AC or DC, selected for your local Fluke representative for compatible current clamps. Refer to measure currents that...
... 600 μA The millivolt and voltage function of the Meter can be used with an optional mV/A output Current Probe to a Fluke catalog or contact your current probe. Make sure the Meter has the correct function, AC or DC, selected for your local Fluke representative for compatible current clamps. Refer to measure currents that...
Fluke 116 Users Manual
Page 18
... graph and range annunciator indicates the underlying voltage up to the full-scale value of −30 V turns on an analog meter. Maintenance Maintenance of the Meter consists of the scale. 116 Users Manual Using the Bargraph The bar graph is disabled when measuring capacitance and temperature. It has an overload indicator (>) to...
... graph and range annunciator indicates the underlying voltage up to the full-scale value of −30 V turns on an analog meter. Maintenance Maintenance of the Meter consists of the scale. 116 Users Manual Using the Bargraph The bar graph is disabled when measuring capacitance and temperature. It has an overload indicator (>) to...
Fluke 116 Users Manual
Page 19
...to clean the case top or lens/window. Dirt or moisture in the terminals can affect readings. 17 Remove the test leads from the Meter before opening the case or battery door. True-rms Multimeter Cleaning The battery fits inside the battery door, which is then inserted into ...Do not use abrasives, isopropyl alcohol, or solvents to lift the door slightly. 4. XWWarning To avoid shock, injury, or damage to the Meter, remove test leads from the Meter. 2. To remove the battery door for battery replacement: 1. Install and tighten battery door screw. Do not attempt to separate it is fully...
...to clean the case top or lens/window. Dirt or moisture in the terminals can affect readings. 17 Remove the test leads from the Meter before opening the case or battery door. True-rms Multimeter Cleaning The battery fits inside the battery door, which is then inserted into ...Do not use abrasives, isopropyl alcohol, or solvents to lift the door slightly. 4. XWWarning To avoid shock, injury, or damage to the Meter, remove test leads from the Meter. 2. To remove the battery door for battery replacement: 1. Install and tighten battery door screw. Do not attempt to separate it is fully...
Fluke 116 Users Manual
Page 20
Extended specifications are available at www.Fluke.com. Maximum voltage between any terminal...40 °C to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 Battery Life Alkaline: 400 hours typical, without backlight Safety Compliances Complies with... 2nd Edition for 1 year after calibration, at operating temperatures of 18 °C to 90 %. 116 Users Manual General Specifications Accuracy is specified for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 Certifications ...
Extended specifications are available at www.Fluke.com. Maximum voltage between any terminal...40 °C to + 60 °C Temperature Coefficient 0.1 x (specified accuracy)/°C (28 °C) Operating Altitude 2,000 meters Battery 9 Volt Alkaline, NEDA 1604A / IEC 6LR61 Battery Life Alkaline: 400 hours typical, without backlight Safety Compliances Complies with... 2nd Edition for 1 year after calibration, at operating temperatures of 18 °C to 90 %. 116 Users Manual General Specifications Accuracy is specified for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 Certifications ...
Fluke 116 Users Manual
Page 23
... μA are dc-coupled. [2] Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. [3] Frequency is normal for this and other true-rms meters to 50 kHz. 21 For volts and μA, crest factor of ≤3 at full scale. True-rms Multimeter General Specifications Table 1 Accuracy Specifications (cont.) Function...
... μA are dc-coupled. [2] Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. [3] Frequency is normal for this and other true-rms meters to 50 kHz. 21 For volts and μA, crest factor of ≤3 at full scale. True-rms Multimeter General Specifications Table 1 Accuracy Specifications (cont.) Function...