...An electronic device that data is passed through it. local bus - LAN on a circuit board with a traditional expansion bus. A signal that lights up when a current is about to be sent to or received by a peripheral device travels by wiring dedicated specifically to run much faster ... grams. kHz - KVM refers to the processor. Local area network. A LAN is displayed and for which the keyboard and mouse are used. Light-emitting diode. Meter(s). Milliampere(s). 4 The wire connects the pins and creates a circuit, providing a simple and reversible method of the system from ...
...An electronic device that data is passed through it. local bus - LAN on a circuit board with a traditional expansion bus. A signal that lights up when a current is about to be sent to or received by a peripheral device travels by wiring dedicated specifically to run much faster ... grams. kHz - KVM refers to the processor. Local area network. A LAN is displayed and for which the keyboard and mouse are used. Light-emitting diode. Meter(s). Milliampere(s). 4 The wire connects the pins and creates a circuit, providing a simple and reversible method of the system from ...
Glossary
Page 45
... = 1024 KB - Kilobyte 1 KB = 1024 Kbps - Liquid crystal display LED - InfiniBand IP - Kilogram 1 kg = 1000 kHz - Local area network LAN LAN LCD - Low voltage differential m - Light-emitting diode LGA - Kilobytes per second KBps - Keyboard/video/mouse KVM LAN - Milliampere 45 LAN on motherboard。 LVD - Internet Protocol version 6。 IPX - Internet...
... = 1024 KB - Kilobyte 1 KB = 1024 Kbps - Liquid crystal display LED - InfiniBand IP - Kilogram 1 kg = 1000 kHz - Local area network LAN LAN LCD - Low voltage differential m - Light-emitting diode LGA - Kilobytes per second KBps - Keyboard/video/mouse KVM LAN - Milliampere 45 LAN on motherboard。 LVD - Internet Protocol version 6。 IPX - Internet...
CLI Guide
Page 201
... address, and the subnet mask address. To turn on or turned off the Service Action Allowed indicator light, set this parameter to on the Service Action Allowed indicator light, set this parameter are listed in the Syntax Element Statement Data table that follows. Script Commands 201 ...number of bytes, and the values to support this parameter to off . The address format for whether the Service Action Allowed indicator light is (0-FFFF):(0-FFFF):(0-FFFF):(0- FFFF). To turn off the remote login feature, set this parameter to TRUE. To turn off . To ...
... address, and the subnet mask address. To turn on or turned off the Service Action Allowed indicator light, set this parameter to on the Service Action Allowed indicator light, set this parameter are listed in the Syntax Element Statement Data table that follows. Script Commands 201 ...number of bytes, and the values to support this parameter to off . The address format for whether the Service Action Allowed indicator light is (0-FFFF):(0-FFFF):(0-FFFF):(0- FFFF). To turn off the remote login feature, set this parameter to TRUE. To turn off . To ...
CLI Guide
Page 251
...the identifier number in square brackets ([ ]). Run the stop physicalDiskChannel blink command to turn off the indicator light on the expansion enclosure. Use the stop physicalDisk blink command to turn off the indicator lights on the physical disk. Enclose the enclosure ID value and the slot ID value in square brackets ([... disk. Script Commands 251 Valid values for the identifier number are connected to a specific physical disk port by turning on an indicator light on the indicator lights for the expansion enclosure that you want Channel to find.
...the identifier number in square brackets ([ ]). Run the stop physicalDiskChannel blink command to turn off the indicator light on the expansion enclosure. Use the stop physicalDisk blink command to turn off the indicator lights on the physical disk. Enclose the enclosure ID value and the slot ID value in square brackets ([... disk. Script Commands 251 Valid values for the identifier number are connected to a specific physical disk port by turning on an indicator light on the indicator lights for the expansion enclosure that you want Channel to find.
CLI Guide
Page 257
... turned on by the start physicalDiskChannel blink command. Syntax stop enclosure blink Parameters None. Stop Physical Disk Channel Blink This command turns off the indicator lights on the expansion enclosures that were turned on by the start physicalDisk blink command. Stop Disk Group Blink This command turns off the indicator LED...
... turned on by the start physicalDiskChannel blink command. Syntax stop enclosure blink Parameters None. Stop Physical Disk Channel Blink This command turns off the indicator lights on the expansion enclosures that were turned on by the start physicalDisk blink command. Stop Disk Group Blink This command turns off the indicator LED...
CLI Guide
Page 259
... virtualDisk or virtualDisks Description Name of an iSCSI session Syntax stop storageArray blink Parameters None. Stop Storage Array Blink This command turns off the indicator lights on the storage array that were turned on -write operation. Stop Storage Array iSCSI Session This command forces the termination of the virtual disk for...
... virtualDisk or virtualDisks Description Name of an iSCSI session Syntax stop storageArray blink Parameters None. Stop Storage Array Blink This command turns off the indicator lights on the storage array that were turned on -write operation. Stop Storage Array iSCSI Session This command forces the termination of the virtual disk for...
Owner's Manual
Page 25
...amber when the enclosure is either in a fault state or the hosts are not using the preferred path to the enclosure. Figure 2-3. The power LED lights green when at least one power supply is on. Blinks blue when a host server is identifying the enclosure or when the system identification button is... reset. Front-Bezel Features and Indicators 1 2 3 Item Indicator, Button, or Icon Connector 1 Enclosure status LED 2 Power LED Description The enclosure status LED lights when the enclosure power is supplying power to a virtual disk. Planning: About Your Storage Array 25
...amber when the enclosure is either in a fault state or the hosts are not using the preferred path to the enclosure. Figure 2-3. The power LED lights green when at least one power supply is on. Blinks blue when a host server is identifying the enclosure or when the system identification button is... reset. Front-Bezel Features and Indicators 1 2 3 Item Indicator, Button, or Icon Connector 1 Enclosure status LED 2 Power LED Description The enclosure status LED lights when the enclosure power is supplying power to a virtual disk. Planning: About Your Storage Array 25
Owner's Manual
Page 30
...the DC output voltage is detected. If this LED is off , it indicates either there is no fault condition is present. 3 AC power The LED lights green when the AC input voltage is not within the limit. If this connector. 5 Power switches (2) The power switch controls the power supply output to...limit. If this LED is off, it indicates that the DC output voltage are not within the limit. 2 Power supply/cooling fan fault The LED lights amber when the DC output voltage is not within the limit or a fault with the fan is within the limit. 4 Power connector Connect the external...
...the DC output voltage is detected. If this LED is off , it indicates either there is no fault condition is present. 3 AC power The LED lights green when the AC input voltage is not within the limit. If this connector. 5 Power switches (2) The power switch controls the power supply output to...limit. If this LED is off, it indicates that the DC output voltage are not within the limit. 2 Power supply/cooling fan fault The LED lights amber when the DC output voltage is not within the limit or a fault with the fan is within the limit. 4 Power connector Connect the external...
Owner's Manual
Page 33
... LED flashes on 1Gbps LED connection. Planning: RAID Controller Modules 33 Off when battery backup unit is down. 12 Controller fault LED Lights amber when controller fault detected. Off when all four links are connected. Off when 1Gbps link is operating normally. 16 Password reset switch... three links are disconnected. Item Component Function 8 SAS OUT port link/fault LED Lights green when all links in the port are disconnected or cable is disconnected. 9 iSCSI IN port link Lights green when ethernet connection at 1Gbps LED established. Off when controller is not turned ...
... LED flashes on 1Gbps LED connection. Planning: RAID Controller Modules 33 Off when battery backup unit is down. 12 Controller fault LED Lights amber when controller fault detected. Off when all four links are connected. Off when 1Gbps link is operating normally. 16 Password reset switch... three links are disconnected. Item Component Function 8 SAS OUT port link/fault LED Lights green when all links in the port are disconnected or cable is disconnected. 9 iSCSI IN port link Lights green when ethernet connection at 1Gbps LED established. Off when controller is not turned ...
Owner's Manual
Page 34
...MD1200 Series expansion enclosures attached to Write Through for all virtual disks. These thresholds cannot be changed. 34 Planning: RAID Controller Modules Lights green when ethernet connection is not active. For information on removing and installing the BBU, see "RAID Controller Module Backup Battery Unit..." on the state of a power outage. If the battery is operating at 1000 Mbps. Lights amber when ethernet connection is missing or does not have sufficient charge, the controller flushes the cache and sets the write cache attribute...
...MD1200 Series expansion enclosures attached to Write Through for all virtual disks. These thresholds cannot be changed. 34 Planning: RAID Controller Modules Lights green when ethernet connection is not active. For information on removing and installing the BBU, see "RAID Controller Module Backup Battery Unit..." on the state of a power outage. If the battery is operating at 1000 Mbps. Lights amber when ethernet connection is missing or does not have sufficient charge, the controller flushes the cache and sets the write cache attribute...
Owner's Manual
Page 232
... might want to use the storage array profile as an aid during recovery or as problems are sent to the appropriate destinations • Hardware indicator lights The status icons return to a text file.
... might want to use the storage array profile as an aid during recovery or as problems are sent to the appropriate destinations • Hardware indicator lights The status icons return to a text file.
Deployment Guide
Page 24
...the RAID controller module firmware and NVSRAM to the storage array. b Turn off the host systems attached to the latest versions available at support.dell.com. b Turn on the expansion enclosure(s). In the Enterprise Management Window (EMW), Click Tools Upgrade RAID Controller Module Firmware. 4 ...; If the status LEDs light solid amber, the storage array is still coming online. • If the status LEDs are blinking amber, there is online and ready, turn off the storage array. a Install the software and driver package included on the PowerVault MD3200i Series resource media.
...the RAID controller module firmware and NVSRAM to the storage array. b Turn off the host systems attached to the latest versions available at support.dell.com. b Turn on the expansion enclosure(s). In the Enterprise Management Window (EMW), Click Tools Upgrade RAID Controller Module Firmware. 4 ...; If the status LEDs light solid amber, the storage array is still coming online. • If the status LEDs are blinking amber, there is online and ready, turn off the storage array. a Install the software and driver package included on the PowerVault MD3200i Series resource media.
Deployment Guide
Page 25
... at support.dell.com/manuals. b Turn on the expansion enclosure(s). Expanding With New PowerVault MD1200 Series Expansion Enclosures Perform the following steps to attach new PowerVault MD1200 series expansion enclosures to a PowerVault MD3200i Series storage array: 1 Before adding the expansion enclosure(s), ensure that can be viewed using MDSM. • If the status LEDs light solid blue...
... at support.dell.com/manuals. b Turn on the expansion enclosure(s). Expanding With New PowerVault MD1200 Series Expansion Enclosures Perform the following steps to attach new PowerVault MD1200 series expansion enclosures to a PowerVault MD3200i Series storage array: 1 Before adding the expansion enclosure(s), ensure that can be viewed using MDSM. • If the status LEDs light solid blue...