EMC PowerEdge Servers Troubleshooting Guide
Page 8
... the Location column in the search box. NOTE: To locate the product name and model, see the Dell OpenManage Server Administrator User's Guide. Additional documentation resources for iDRAC. On the Product Support page, click Manuals & documents. • Using search engines: ○ Type the name and version of your system. Configuring your system...
... the Location column in the search box. NOTE: To locate the product name and model, see the Dell OpenManage Server Administrator User's Guide. Additional documentation resources for iDRAC. On the Product Support page, click Manuals & documents. • Using search engines: ○ Type the name and version of your system. Configuring your system...
EMC PowerEdge Servers Troubleshooting Guide
Page 21
... Chkdsk /r or format your hard drive and reinstall your systems Owners Manual at both ends of the data 1. Repeat the PSA diagnostics. 4.... is desktop. 3. Running diagnostics 21 timeout waiting for your optical drive to the system board. 3. Check www.dell.com/ support for a firmware update for Drive Self Test to the system board. 3. Update to the latest...0150 replaced 2000-0141 Hard Drive - Reseat the drive, reseat the data cable and power connection at www.dell.com/ poweredgemanuals. 4. For more information, see your operating system. 3. PSA 1000-0148 ePSA 2000-0148 ...
... Chkdsk /r or format your hard drive and reinstall your systems Owners Manual at both ends of the data 1. Repeat the PSA diagnostics. 4.... is desktop. 3. Running diagnostics 21 timeout waiting for your optical drive to the system board. 3. Check www.dell.com/ support for a firmware update for Drive Self Test to the system board. 3. Update to the latest...0150 replaced 2000-0141 Hard Drive - Reseat the drive, reseat the data cable and power connection at www.dell.com/ poweredgemanuals. 4. For more information, see your operating system. 3. PSA 1000-0148 ePSA 2000-0148 ...
EMC PowerEdge Servers Troubleshooting Guide
Page 55
Checking hard drive status in the Dell EMC PowerEdge Servers Troubleshooting Guide. PERC Configuration Utility VD Mgmt screen ...and transitioned to import the foreign configuration. 7. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to open PERC BIOS Configuration Utility. Figure 13. Reseat the controller card. ...4. Press Ctrl + R during the POST process to perform a manual rebuild of multiple physical disks. 8. Troubleshooting hardware issues 55 Reseat the Drives and ensure that all...
Checking hard drive status in the Dell EMC PowerEdge Servers Troubleshooting Guide. PERC Configuration Utility VD Mgmt screen ...and transitioned to import the foreign configuration. 7. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to open PERC BIOS Configuration Utility. Figure 13. Reseat the controller card. ...4. Press Ctrl + R during the POST process to perform a manual rebuild of multiple physical disks. 8. Troubleshooting hardware issues 55 Reseat the Drives and ensure that all...
EMC PowerEdge Servers Troubleshooting Guide
Page 58
... transitioned to import the foreign configuration. 7. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to servicing that the interface cable is not covered by Dell is securely connected to the optical drive and to a cable pull or power loss situation, ...the virtual disk is imported in cabling or connection and could involve the loss of multiple physical disks. Damage due to perform a manual rebuild of data. Run...
... transitioned to import the foreign configuration. 7. You can also use the BIOS Configuration Utility or Dell OpenManage storage management application to servicing that the interface cable is not covered by Dell is securely connected to the optical drive and to a cable pull or power loss situation, ...the virtual disk is imported in cabling or connection and could involve the loss of multiple physical disks. Damage due to perform a manual rebuild of data. Run...
EMC PowerEdge Servers Troubleshooting Guide
Page 60
... NOTE: After installing a power supply unit, allow several interfaces. If the problem persists, see Lifecycle Controller User's Guide available at www.dell.com/ poweredgemanuals. RAID volumes can be created using Lifecycle controller. For example, loose power cables. 2. If you have a redundant power...indicator does not glow when the power button is displayed. 60 Troubleshooting hardware issues Plug in the Installation and Service Manual available at www.dell.com/idracmanuals . 2. Ensure that the system board is working properly. Reseat the power supply unit. For more ...
... NOTE: After installing a power supply unit, allow several interfaces. If the problem persists, see Lifecycle Controller User's Guide available at www.dell.com/ poweredgemanuals. RAID volumes can be created using Lifecycle controller. For example, loose power cables. 2. If you have a redundant power...indicator does not glow when the power button is displayed. 60 Troubleshooting hardware issues Plug in the Installation and Service Manual available at www.dell.com/idracmanuals . 2. Ensure that the system board is working properly. Reseat the power supply unit. For more ...
EMC PowerEdge Servers Troubleshooting Guide
Page 62
... During bootup, press Ctrl + R when prompted by checking the physical disk state. You can use the BIOS Configuration Utility or Dell OpenManage storage management application to the controller. If the physical disk state is displayed by default. 62 Troubleshooting hardware issues If you have... been added to perform a manual rebuild of Hard Drives RAID 1 2 RAID 5 6 RAID 10 6 RAID 5 24 RAID 10 24 7.2 K rpm 12 Gbps SAS Hard ...
... During bootup, press Ctrl + R when prompted by checking the physical disk state. You can use the BIOS Configuration Utility or Dell OpenManage storage management application to the controller. If the physical disk state is displayed by default. 62 Troubleshooting hardware issues If you have... been added to perform a manual rebuild of Hard Drives RAID 1 2 RAID 5 6 RAID 10 6 RAID 5 24 RAID 10 24 7.2 K rpm 12 Gbps SAS Hard ...
EMC PowerEdge Servers Troubleshooting Guide
Page 72
.... Copy MegaSAS.log to datastore by using command:cp /opt/lsi/perccli/MegaSAS.log /vmfs/volumes/datastore1/ 9. For slot information, see the server Owner's Manual at www.dell.com/poweredgemanuals. NOTE: Create boot virtual disk only from a disk drive populated across slots 0-3 of the system. Steps 1. Log file in Datastore Browser Now...
.... Copy MegaSAS.log to datastore by using command:cp /opt/lsi/perccli/MegaSAS.log /vmfs/volumes/datastore1/ 9. For slot information, see the server Owner's Manual at www.dell.com/poweredgemanuals. NOTE: Create boot virtual disk only from a disk drive populated across slots 0-3 of the system. Steps 1. Log file in Datastore Browser Now...
EMC PowerEdge Servers Troubleshooting Guide
Page 78
...; Disabled - Initiates the Patrol Read task. NOTE: For more information on the controller in Auto mode, see your controller documentation. • Manual - If the system reboots while Patrol Read is applicable only for disks used as a hot spare. • The physical disk is included ...dedicated hot spare. Patrol Read does not run time and result. When the Patrol Read task is finished. Setting the mode to Manual does not initiate the Patrol Read task. Initiates the Patrol Read task. Memory channels (continued) Property Dedicated Hot Spare Definition Displays ...
...; Disabled - Initiates the Patrol Read task. NOTE: For more information on the controller in Auto mode, see your controller documentation. • Manual - If the system reboots while Patrol Read is applicable only for disks used as a hot spare. • The physical disk is included ...dedicated hot spare. Patrol Read does not run time and result. When the Patrol Read task is finished. Setting the mode to Manual does not initiate the Patrol Read task. Initiates the Patrol Read task. Memory channels (continued) Property Dedicated Hot Spare Definition Displays ...
EMC PowerEdge Servers Troubleshooting Guide
Page 84
... DRAM memory, which is utilized when the server is RAID punctured. 84 Troubleshooting hardware issues RAID puncture A RAID puncture is a feature of Dell PowerEdge RAID Controller (PERC) designed to allow the controller to restore the redundancy of the array despite the loss of RAID puncture Without the RAID... the battery to a rebuilding drive. • Double Fault does not exist (Data is propagated (copied) to a fully functional condition. To perform a manual Learn Cycle, select Start Learn Cycle from the Battery Tasks drop-down menu in OpenManage Server Administrator should have...
... DRAM memory, which is utilized when the server is RAID punctured. 84 Troubleshooting hardware issues RAID puncture A RAID puncture is a feature of Dell PowerEdge RAID Controller (PERC) designed to allow the controller to restore the redundancy of the array despite the loss of RAID puncture Without the RAID... the battery to a rebuilding drive. • Double Fault does not exist (Data is propagated (copied) to a fully functional condition. To perform a manual Learn Cycle, select Start Learn Cycle from the Battery Tasks drop-down menu in OpenManage Server Administrator should have...
EMC PowerEdge Servers Troubleshooting Guide
Page 92
... physical disk that fails in the virtual disk), then use the Assign and Unassign Dedicated Hot Spare. You should be assigned and unassigned manually. If you do not have installed the latest version of Server Administrator. NOTE: When deleting virtual disks, all assigned dedicated hot spares ... software issues When a physical disk that is part of a disk group is displayed. You can also assign more information, see the Dell EMC OpenManage Software Support Matrix available on the support site. Executing this task on the global hot spare, it replaces any of the following...
... physical disk that fails in the virtual disk), then use the Assign and Unassign Dedicated Hot Spare. You should be assigned and unassigned manually. If you do not have installed the latest version of Server Administrator. NOTE: When deleting virtual disks, all assigned dedicated hot spares ... software issues When a physical disk that is part of a disk group is displayed. You can also assign more information, see the Dell EMC OpenManage Software Support Matrix available on the support site. Executing this task on the global hot spare, it replaces any of the following...
EMC PowerEdge Servers Troubleshooting Guide
Page 99
... connect to iDRAC port through a switch You can use WMI protocol for all servers. NOTE: For more information, see the iDRAC manuals at will. Guidance on connecting to iDRAC, see Build and Deploy Remote Desktop Services NOTE: Provide the correct Microsoft Windows version while purchasing... small or complex as you can increase and decrease Remote Desktop Web Access, Gateway, Connection Broker and Session Host servers at www.dell.com/idracmanuals Lifecycle Controller is not recognizing USB in SNMP Configuration page. • To disable SNMP discovery uncheck the Enable SNMP discovery...
... connect to iDRAC port through a switch You can use WMI protocol for all servers. NOTE: For more information, see the iDRAC manuals at will. Guidance on connecting to iDRAC, see Build and Deploy Remote Desktop Services NOTE: Provide the correct Microsoft Windows version while purchasing... small or complex as you can increase and decrease Remote Desktop Web Access, Gateway, Connection Broker and Session Host servers at www.dell.com/idracmanuals Lifecycle Controller is not recognizing USB in SNMP Configuration page. • To disable SNMP discovery uncheck the Enable SNMP discovery...
EMC PowerEdge Servers Troubleshooting Guide
Page 103
...power is not fully drained. Read and follow the safety instructions that the server is displayed, which indicates that are shipped with your system's Owner's Manual at POST during a reboot. NOTE: When removing or replacing parts, always turn off the server, remove the power cord, and wait for ten...only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by your system. NOTE: Ensure that is not authorized by Dell is a series of -date, or the server needs a reboot for the iDRAc to the first boot device. Either the system BIOS is ...
...power is not fully drained. Read and follow the safety instructions that the server is displayed, which indicates that are shipped with your system's Owner's Manual at POST during a reboot. NOTE: When removing or replacing parts, always turn off the server, remove the power cord, and wait for ten...only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by your system. NOTE: Ensure that is not authorized by Dell is a series of -date, or the server needs a reboot for the iDRAc to the first boot device. Either the system BIOS is ...
EMC PowerEdge Servers Troubleshooting Guide
Page 104
... PSU1, CPU1, memory module in A1 slot. For tower servers, the minimum to discharge. If you identify the defective part, contact Dell Technical Support with information about the defective part. b. a. Migrating to POST the server. Disconnect all cables from the server and attempt ... CPU1, and memory module in A1 slot, and the default riser without expansion cards. For more information , see your system's Owner's manual at qrl.dell.com. 2. b. If the server completes the POST, turn off the server. Disconnect the hard drives, optical drives, and tape drives ...
... PSU1, CPU1, memory module in A1 slot. For tower servers, the minimum to discharge. If you identify the defective part, contact Dell Technical Support with information about the defective part. b. a. Migrating to POST the server. Disconnect all cables from the server and attempt ... CPU1, and memory module in A1 slot, and the default riser without expansion cards. For more information , see your system's Owner's manual at qrl.dell.com. 2. b. If the server completes the POST, turn off the server. Disconnect the hard drives, optical drives, and tape drives ...
EMC PowerEdge Servers Troubleshooting Guide
Page 108
... Before installing the OS, ensure that Load Legacy Option Rom on the Integrated Device Settings screen is set to Disable. To avoid removing the hardware manually, you can also disable the PCIe slots in UEFI mode after installing the OS 3. Resolution In the BIOS configuration utility, ensure that there are ...2016 with an error message Cause This issue occurs when the size of -box drivers for USB 3.0, and are no add-on devices installed on PowerEdge Servers fail at www.dell.com/support. 2. Restart the system. 4. NOTE: By default, the USB 3.0 option is set to Enable.
... Before installing the OS, ensure that Load Legacy Option Rom on the Integrated Device Settings screen is set to Disable. To avoid removing the hardware manually, you can also disable the PCIe slots in UEFI mode after installing the OS 3. Resolution In the BIOS configuration utility, ensure that there are ...2016 with an error message Cause This issue occurs when the size of -box drivers for USB 3.0, and are no add-on devices installed on PowerEdge Servers fail at www.dell.com/support. 2. Restart the system. 4. NOTE: By default, the USB 3.0 option is set to Enable.
EMC PowerEdge Servers Troubleshooting Guide
Page 111
...be in a protected state. The vSphere CLI is added to attain the protected state. For some PowerEdge systems with AMD 6300 series processor, VMs configured with Fault Tolerance (FT) might not be unable ...shuts down. Provide a reason for download from the inventory. Configuration backup and restore procedures Dell EMC recommends that you back up your VMware ESXi configuration after you want to back ...• You have already imported the vSphere CLI to meet storage requirements. You must manually power on an ESXi host. The backup and restore steps are given in the Maintenance ...
...be in a protected state. The vSphere CLI is added to attain the protected state. For some PowerEdge systems with AMD 6300 series processor, VMs configured with Fault Tolerance (FT) might not be unable ...shuts down. Provide a reason for download from the inventory. Configuration backup and restore procedures Dell EMC recommends that you back up your VMware ESXi configuration after you want to back ...• You have already imported the vSphere CLI to meet storage requirements. You must manually power on an ESXi host. The backup and restore steps are given in the Maintenance ...
EMC PowerEdge Servers Troubleshooting Guide
Page 114
... 17. Repurpose or Retire System Repurpose or Retire System 24. Export Server Profile Using USB Drive USB Drive 7. Dell LifecC - Backup Server Profile LC - Unattended Installation Using USB OS Deployment - Manual Install method 26. Firmware Update Using FTP LC Firmware Update Using FTP Server Server 4. Deploying an Operating System using Lifecycle Controller...
... 17. Repurpose or Retire System Repurpose or Retire System 24. Export Server Profile Using USB Drive USB Drive 7. Dell LifecC - Backup Server Profile LC - Unattended Installation Using USB OS Deployment - Manual Install method 26. Firmware Update Using FTP LC Firmware Update Using FTP Server Server 4. Deploying an Operating System using Lifecycle Controller...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 6
... operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview Supported PowerEdge systems The following operating systems: • Microsoft ○... operating systems and driver installation instructions, see the Drivers and Downloads section at www.dell.com/operatingsystemmanuals. For specific operating system service pack requirements, see the operating system documentation at www...
... operating systems The BOSS-S1 card supports the following PowerEdge systems support the BOSS-S1 adapter card: • PowerEdge C4140 • PowerEdge C6525 • PowerEdge R240 • PowerEdge R340 • PowerEdge R440 • PowerEdge R540 6 Overview Supported PowerEdge systems The following operating systems: • Microsoft ○... operating systems and driver installation instructions, see the Drivers and Downloads section at www.dell.com/operatingsystemmanuals. For specific operating system service pack requirements, see the operating system documentation at www...
EMC Boot Optimized Server Storage-S1 Users Guide
Page 22
... displayed. Click Controller information. 2. Click Create RAID Configuration. 3. Click Next. 5. A virtual disk is an available target device. Click Delete RAID configuration. 3. RAID rebuild You can manually rebuild a degraded virtual disk. Clear configuration operation does not affect any data on the virtual disk. 1. Enter the BOSS-S1 configuration utility. See Entering the...
... displayed. Click Controller information. 2. Click Create RAID Configuration. 3. Click Next. 5. A virtual disk is an available target device. Click Delete RAID configuration. 3. RAID rebuild You can manually rebuild a degraded virtual disk. Clear configuration operation does not affect any data on the virtual disk. 1. Enter the BOSS-S1 configuration utility. See Entering the...
EMC PowerEdge RAID Controller S140 Users Guide
Page 11
... Utility. NOTE: Ensure that configures and maintains RAID disk groups and virtual disks. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the Lifecycle Controller User's Guide at www.dell.com/idracmanuals. This is also known as Ctrl+R, and is supported. RAID configurations on page 38...BIOS Configuration Utility - See Setting the NVMe PCIe SSDs to SATA NOTE: Only Dell - This storage management application is not supported in iDRAC, see the OpenManage Storage Management User's Guide at dell.com/manuals. inch small form factor and NVMe PCIe SSD adapter. • DVD drives ...
... Utility. NOTE: Ensure that configures and maintains RAID disk groups and virtual disks. inch SFF and PowerEdge NVMe PCIe SSD adapter, see the Lifecycle Controller User's Guide at www.dell.com/idracmanuals. This is also known as Ctrl+R, and is supported. RAID configurations on page 38...BIOS Configuration Utility - See Setting the NVMe PCIe SSDs to SATA NOTE: Only Dell - This storage management application is not supported in iDRAC, see the OpenManage Storage Management User's Guide at dell.com/manuals. inch small form factor and NVMe PCIe SSD adapter. • DVD drives ...
EMC PowerEdge RAID Controller S140 Users Guide
Page 12
... blinks continuously while there are part of the PERC S140. CAUTION: Do not attempt disk roaming during online capacity expansion (OCE). Hot-swapping is the manual replacement of the same drive type (HDD, SSD or NVMe PCIe SSD). NOTE: Disk hot-swapping is supported only in OS mode. NOTE: When hot...
... blinks continuously while there are part of the PERC S140. CAUTION: Do not attempt disk roaming during online capacity expansion (OCE). Hot-swapping is the manual replacement of the same drive type (HDD, SSD or NVMe PCIe SSD). NOTE: Disk hot-swapping is supported only in OS mode. NOTE: When hot...