Dell PowerConnect M8024-k User's Configuration Guide
Page 13
... 244 Device Information 244 System Health 246 System Resources 247 Integrated Cable Test for Copper Cables. . . . . . 248 Optical Transceiver Diagnostics 249 Log Global Settings 251 RAM Log 252 Contents 13
... 244 Device Information 244 System Health 246 System Resources 247 Integrated Cable Test for Copper Cables. . . . . . 248 Optical Transceiver Diagnostics 249 Log Global Settings 251 RAM Log 252 Contents 13
Dell PowerConnect M8024-k User's Configuration Guide
Page 112
Default Settings (Continued) Feature SNMP logging Console logging RAM logging Persistent (FLASH) logging DNS SNMP SNMP Traps Auto Configuration Auto Save Stacking (PCM6220 and PCM6348) Nonstop Forwarding on the Stack (PCM6220 and PCM6348) sFlow ...
Default Settings (Continued) Feature SNMP logging Console logging RAM logging Persistent (FLASH) logging DNS SNMP SNMP Traps Auto Configuration Auto Save Stacking (PCM6220 and PCM6348) Nonstop Forwarding on the Stack (PCM6220 and PCM6348) sFlow ...
Dell PowerConnect M8024-k User's Configuration Guide
Page 240
... Simple Mail Transport Protocol SMTP) server for viewing and storage. • Email - By default, these messages are cleared. When the RAM log file reaches the configured maximum size, the oldest message is deleted from the switch. 240 Monitoring and Logging System Information Messages sent ...accountability. The information the switch provides can be affecting system performance. This collection of log files is added. In addition to the RAM log, you troubleshoot issues that log files are connected to the switch CLI through the console port, messages display to the switch....
... Simple Mail Transport Protocol SMTP) server for viewing and storage. • Email - By default, these messages are cleared. When the RAM log file reaches the configured maximum size, the oldest message is deleted from the switch. 240 Monitoring and Logging System Information Messages sent ...accountability. The information the switch provides can be affecting system performance. This collection of log files is added. In addition to the RAM log, you troubleshoot issues that log files are connected to the switch CLI through the console port, messages display to the switch....
Dell PowerConnect M8024-k User's Configuration Guide
Page 243
Dell recommends that is enabled, and messages are sent to the log file that network administrators deploy a syslog server in the stack forward their network and configure all switches to log messages to the syslog server. Other platforms in their messages to the console (severity level: warning and above), and RAM... recipient email address, log messages with a severity level of emergency and alert are sent immediately with a severity level of switches, the RAM log and persistent log files exist only on a per-stack member basis. • Message - Email alerting is disabled, and no...
Dell recommends that is enabled, and messages are sent to the log file that network administrators deploy a syslog server in the stack forward their network and configure all switches to log messages to the syslog server. Other platforms in their messages to the console (severity level: warning and above), and RAM... recipient email address, log messages with a severity level of emergency and alert are sent immediately with a severity level of switches, the RAM log and persistent log files exist only on a per-stack member basis. • Message - Email alerting is disabled, and no...
Dell PowerConnect M8024-k User's Configuration Guide
Page 251
... lists log messages from being sent to the lowest (Debug). To prevent log messages from the highest severity (Emergency) to the console, RAM log, or flash log file, clear all higher levels are logged to enable other types of messages that are automatically selected. Figure 10...-9. Log Global Settings Use the Global Settings page to enable logging globally, to the console, RAM log, and flash-based log file. To display the Global Settings page, click System → Logs → Global Settings in the Severity...
... lists log messages from being sent to the lowest (Debug). To prevent log messages from the highest severity (Emergency) to the console, RAM log, or flash log file, clear all higher levels are logged to enable other types of messages that are automatically selected. Figure 10...-9. Log Global Settings Use the Global Settings page to enable logging globally, to the console, RAM log, and flash-based log file. To display the Global Settings page, click System → Logs → Global Settings in the Severity...
Dell PowerConnect M8024-k User's Configuration Guide
Page 252
To display the RAM Log, click System → Logs → RAM Log in the navigation panel. RAM Log Table 252 Monitoring and Logging System Information Figure 10-10. RAM Log Use the RAM Log page to view information about specific RAM (cache) log entries, including the time the log was entered, the log severity, and a description of the log.
To display the RAM Log, click System → Logs → RAM Log in the navigation panel. RAM Log Table 252 Monitoring and Logging System Information Figure 10-10. RAM Log Use the RAM Log page to view information about specific RAM (cache) log entries, including the time the log was entered, the log severity, and a description of the log.
Dell PowerConnect M8024-k User's Configuration Guide
Page 262
...Logging System Information Disable green mode prior to monitor the PowerConnect M6220/M6348/M8024/M8024-k switch. Displays the total and available RAM space on the port. Command show system show system power show system temperature show memory cpu show process cpu Purpose Display ...Logging (CLI) This section provides information about these commands, see the PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide at support.dell.com/manuals. Displays the power supply status. Running Cable Diagnostics Beginning in Privileged EXEC mode, use to running on the switch. ...
...Logging System Information Disable green mode prior to monitor the PowerConnect M6220/M6348/M8024/M8024-k switch. Displays the total and available RAM space on the port. Command show system show system power show system temperature show memory cpu show process cpu Purpose Display ...Logging (CLI) This section provides information about these commands, see the PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide at support.dell.com/manuals. Displays the power supply status. Running Cable Diagnostics Beginning in Privileged EXEC mode, use to running on the switch. ...
Dell PowerConnect M8024-k User's Configuration Guide
Page 264
... through the console port. • file - logging facility facility- show logging file View information about severity levels, see Table 10-1. clear logging Use to the RAM file (cache). Enables logging to clear messages from the logging buffer. 264 Monitoring and Logging System Information For information about the flash (persistent) log file...
... through the console port. • file - logging facility facility- show logging file View information about severity levels, see Table 10-1. clear logging Use to the RAM file (cache). Enables logging to clear messages from the logging buffer. 264 Monitoring and Logging System Information For information about the flash (persistent) log file...
Dell PowerConnect M8024-k User's Configuration Guide
Page 269
Log messages with a severity level of Notification (level 5) and above are sent locally and what severity level of message is to the RAM (buffered) log. console#configure console(config)#logging audit console(config)#logging cli-command 2 Specify where the logs are sent to be logged. Emergency, Critical, and ...
Log messages with a severity level of Notification (level 5) and above are sent locally and what severity level of message is to the RAM (buffered) log. console#configure console(config)#logging audit console(config)#logging cli-command 2 Specify where the logs are sent to be logged. Emergency, Critical, and ...
Dell PowerConnect M8024-k User's Configuration Guide
Page 270
.../Hostname Port Severity Description 192.168.2.10 514 debugging Syslog Server 5 Verify the local logging configuration and view the log messages stored in the buffer (RAM log). 4 Verify the remote log server configuration.
.../Hostname Port Severity Description 192.168.2.10 514 debugging Syslog Server 5 Verify the local logging configuration and view the log messages stored in the buffer (RAM log). 4 Verify the remote log server configuration.
Dell PowerConnect M8024-k User's Configuration Guide
Page 1241
..., 1129 R RADIUS configuring, 222 contact order, 178 defaults, 180 DiffServ filters, 516 primary and secondary servers, 231 server configuration, 201 server groups, 178 understanding, 176 RAM log, 252 real time clock, 276 redirect, ACL, 545 relay agent, DHCPv6, 1078 relay, DHCP, 919 remote logging, 265 rendezvous point, PIM, 1155 RIP CLI...
..., 1129 R RADIUS configuring, 222 contact order, 178 defaults, 180 DiffServ filters, 516 primary and secondary servers, 231 server configuration, 201 server groups, 178 understanding, 176 RAM log, 252 real time clock, 276 redirect, ACL, 545 relay agent, DHCPv6, 1078 relay, DHCP, 919 remote logging, 265 rendezvous point, PIM, 1155 RIP CLI...
Dell PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide
Page 157
... open telnet sessions to PE remote hosts. UE show banner Displays banner information. UE Command Groups 157 show memory cpu Checks the total and available RAM space on the OOB port. PE band show cut-through mode Show the cut-through mode on the switch. show slot Displays information about the...
... open telnet sessions to PE remote hosts. UE show banner Displays banner information. UE Command Groups 157 show memory cpu Checks the total and available RAM space on the OOB port. PE band show cut-through mode Show the cut-through mode on the switch. show slot Displays information about the...
Dell PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide
Page 212
Run flash diagnostics 7 - Delete backup image 9 - Reset the system 10 - Activate Backup Image 12 - Display PCI bus details 4 - Display core info and bus speeds 5 - RAM test 7 - CPLD diagnostics 9 - Switch diagnostics 212 Using the CLI Display operational code vital product data 6 - Restore configuration to factory defaults (delete config files) 11 - Change ...
Run flash diagnostics 7 - Delete backup image 9 - Reset the system 10 - Activate Backup Image 12 - Display PCI bus details 4 - Display core info and bus speeds 5 - RAM test 7 - CPLD diagnostics 9 - Switch diagnostics 212 Using the CLI Display operational code vital product data 6 - Restore configuration to factory defaults (delete config files) 11 - Change ...
Dell PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide
Page 213
...: none Unit Service tag Asset tag 2 89788978 Serial number -- File system test 12 - Upload FRU data through X-Modem and store into FRU 2 - 10 - Comprehensive test (RAM, PCI, FLASH) 13 - Download data through X-Modem and store into FLASH 3 - Format file system 11 -
...: none Unit Service tag Asset tag 2 89788978 Serial number -- File system test 12 - Upload FRU data through X-Modem and store into FRU 2 - 10 - Comprehensive test (RAM, PCI, FLASH) 13 - Download data through X-Modem and store into FLASH 3 - Format file system 11 -
Dell PowerConnect M6220/M6348/M8024/M8024-k CLI Reference Guide
Page 1562
Command Mode Privileged EXEC User Guidelines No specific guidelines. Example console#show memory cpu command to check the total and available RAM space on the switch. IP Address 10.240.4.115 Subnet Mask 255.255.255.0 Default Gateway 10.240.4.1 IPv6 Prefix is FE80::20A:1EFF:FE11:...
Command Mode Privileged EXEC User Guidelines No specific guidelines. Example console#show memory cpu command to check the total and available RAM space on the switch. IP Address 10.240.4.115 Subnet Mask 255.255.255.0 Default Gateway 10.240.4.1 IPv6 Prefix is FE80::20A:1EFF:FE11:...
Fabric Watch Administrator’s Guide
Page 26
... enables you can use the sysMonitor command to another. Fabric Watch supports port movement from , and created for the logical switch to monitor your system's RAM, flash, memory, and CPU. You can specify a switch policy so that define specific health states for information on viewing the current switch policies using the...
... enables you can use the sysMonitor command to another. Fabric Watch supports port movement from , and created for the logical switch to monitor your system's RAM, flash, memory, and CPU. You can specify a switch policy so that define specific health states for information on viewing the current switch policies using the...
Getting Started Guide
Page 15
...) Getting Started With Your System 13 Memory (continued) PowerEdge M710HD PowerEdge M710, M610x, M610, PowerEdge M600 Memory module sockets PowerEdge M915, M910 PowerEdge M905 PowerEdge M805 PowerEdge M710HD, M710 PowerEdge M610x, M610 PowerEdge M605, M600 Memory module capacities PowerEdge M915 PowerEdge M910 PowerEdge M905, M805, PowerEdge M710HD PowerEdge M710, M610x, M610 PowerEdge M605, M600 Minimum RAM PowerEdge M915 PowerEdge M910 PowerEdge M905 DDR3 and DDR3L single-, dual-, and quad...
...) Getting Started With Your System 13 Memory (continued) PowerEdge M710HD PowerEdge M710, M610x, M610, PowerEdge M600 Memory module sockets PowerEdge M915, M910 PowerEdge M905 PowerEdge M805 PowerEdge M710HD, M710 PowerEdge M610x, M610 PowerEdge M605, M600 Memory module capacities PowerEdge M915 PowerEdge M910 PowerEdge M905, M805, PowerEdge M710HD PowerEdge M710, M610x, M610 PowerEdge M605, M600 Minimum RAM PowerEdge M915 PowerEdge M910 PowerEdge M905 DDR3 and DDR3L single-, dual-, and quad...
Getting Started Guide
Page 16
...H200 embedded storage controller. 14 Getting Started With Your System Memory (continued) PowerEdge M805 PowerEdge M710D PowerEdge M710, M610x, M610 PowerEdge M605, M600 Maximum RAM PowerEdge M915 PowerEdge M910 PowerEdge M905 PowerEdge M805 PowerEdge M710HD PowerEdge M710 PowerEdge M610x, M610 PowerEdge M605, M600 4 GB (Four 1 GB memory modules) 4 GB ... GB (Twelve 16 GB RDIMMs); 24 GB (Twelve 2 GB UDIMMs) 64 GB Drives Hard Drives PowerEdge M915, M910 PowerEdge M905, M805 PowerEdge M710HD Up to two 2.5-inch SAS hard drives support through PERC H200 embedded storage controller. Up to ...
...H200 embedded storage controller. 14 Getting Started With Your System Memory (continued) PowerEdge M805 PowerEdge M710D PowerEdge M710, M610x, M610 PowerEdge M605, M600 Maximum RAM PowerEdge M915 PowerEdge M910 PowerEdge M905 PowerEdge M805 PowerEdge M710HD PowerEdge M710 PowerEdge M610x, M610 PowerEdge M605, M600 4 GB (Four 1 GB memory modules) 4 GB ... GB (Twelve 16 GB RDIMMs); 24 GB (Twelve 2 GB UDIMMs) 64 GB Drives Hard Drives PowerEdge M915, M910 PowerEdge M905, M805 PowerEdge M710HD Up to two 2.5-inch SAS hard drives support through PERC H200 embedded storage controller. Up to ...
Hardware Owner's Manual
Page 110
... seconds and restart the system. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. E2014 CMOS RAM failure. CMOS failure. CMOS RAM not functioning properly. E2017 Timer refresh failure. Power cycle AC. Remove AC power to shadow memory. See "Troubleshooting Blade Memory" on page 319...
... seconds and restart the system. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. E2014 CMOS RAM failure. CMOS failure. CMOS RAM not functioning properly. E2017 Timer refresh failure. Power cycle AC. Remove AC power to shadow memory. See "Troubleshooting Blade Memory" on page 319...
Owners Manual
Page 69
... DVD NOTE: DVD devices are data only. 7 Technical Specifications Processor Processor type Memory Architecture Memory module sockets Memory module capacities RDIMMs UDIMMs LRDIMMs Minimum RAM Maximum RAM Drives Hard drives Optical drive Flash drive Connectors Front USB Internal SD One or two Intel Xeon processor E5-2600 product family 1600 MT/s, 1333...
... DVD NOTE: DVD devices are data only. 7 Technical Specifications Processor Processor type Memory Architecture Memory module sockets Memory module capacities RDIMMs UDIMMs LRDIMMs Minimum RAM Maximum RAM Drives Hard drives Optical drive Flash drive Connectors Front USB Internal SD One or two Intel Xeon processor E5-2600 product family 1600 MT/s, 1333...