Information Update
Page 10
... - NOTE: OpenManage version 6.0.1 does not support PowerEdge M600, M605, M805, or M905 blades. 10 Information Update Dell™ OpenManage™ Version Requirements The PowerEdge M905 and M805 blades require OpenManage systems management software version 5.4.3 or later. NOTE: OpenManage version 5.4.3 does not support PowerEdge M600 or M605 blades. The PowerEdge M610 and M710 blades require OpenManage systems...
... - NOTE: OpenManage version 6.0.1 does not support PowerEdge M600, M605, M805, or M905 blades. 10 Information Update Dell™ OpenManage™ Version Requirements The PowerEdge M905 and M805 blades require OpenManage systems management software version 5.4.3 or later. NOTE: OpenManage version 5.4.3 does not support PowerEdge M600 or M605 blades. The PowerEdge M610 and M710 blades require OpenManage systems...
Information Update
Page 11
...add these blades to an M1000e enclosure with your local system. PowerEdge M610 and M710 blades require CMC firmware version 2.0 or later. NOTE: See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on how to the factory default settings.... CMC Firmware Requirements PowerEdge M905 and M805 blades require CMC firmware version 1.2 or later....
...add these blades to an M1000e enclosure with your local system. PowerEdge M610 and M710 blades require CMC firmware version 2.0 or later. NOTE: See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on how to the factory default settings.... CMC Firmware Requirements PowerEdge M905 and M805 blades require CMC firmware version 1.2 or later....
Information Update
Page 21
... and M905 blades support one or two 2.5-inch SAS hard-disk drives. • The PowerEdge M710 blade supports one to four 2.5 inch SAS hard drives. • The PowerEdge M610, M600 and M605 blades support one or two solid-state disk (SSD) hard drives. inch SATA hard drives, one or two 2.5-inch SAS hard...
... and M905 blades support one or two 2.5-inch SAS hard-disk drives. • The PowerEdge M710 blade supports one to four 2.5 inch SAS hard drives. • The PowerEdge M610, M600 and M605 blades support one or two solid-state disk (SSD) hard drives. inch SATA hard drives, one or two 2.5-inch SAS hard...
Information Update
Page 153
• PowerEdge M805 및 M905 1 - 2 개의 2.5 인치 SAS • PowerEdge M710 1 - 4 개의 2.5 인치 SAS • PowerEdge M610, M600 및 M605 1 - 2 개의 2.5 인치 SATA 1 - 2 개의 2.5 인치 SAS 1 - 2 개의 SSD(Solid State Disk 주 : SAS 와 SATA RAID 주 : SATA SATA • RAID 153
• PowerEdge M805 및 M905 1 - 2 개의 2.5 인치 SAS • PowerEdge M710 1 - 4 개의 2.5 인치 SAS • PowerEdge M610, M600 및 M605 1 - 2 개의 2.5 인치 SATA 1 - 2 개의 2.5 인치 SAS 1 - 2 개의 SSD(Solid State Disk 주 : SAS 와 SATA RAID 주 : SATA SATA • RAID 153
User Manual
Page 10
...: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. De-rate maximum allowable dry bulb temperature at 10% to 14.0 lb) Physical - Blades Height Width Depth Weight (maximum) PowerEdge M710HD and M620 Height Width Depth Weight (maximum) PowerEdge M610 Height Width Depth Weight (maximum) 38.5 cm (15.2 inch) 5 cm (2 inch...
...: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. De-rate maximum allowable dry bulb temperature at 10% to 14.0 lb) Physical - Blades Height Width Depth Weight (maximum) PowerEdge M710HD and M620 Height Width Depth Weight (maximum) PowerEdge M610 Height Width Depth Weight (maximum) 38.5 cm (15.2 inch) 5 cm (2 inch...
Hardware Owner's Manual
Page 5
... Navigation Keys 138 System Setup Options 139 Memory Settings Screen 140 Processor Settings Screen 141 SATA Settings Screen (PowerEdge M610, M610x 143 Boot Settings Screen 143 Integrated Devices Screen 144 PCI IRQ Assignments Screen 146 Serial Communication Screen 146 Power Management ...Screen (PowerEdge M915, M910, M710, M710HD, M610 and M610x Only 147 System Security Screen 148 Exit Screen 149 Entering the UEFI Boot Manager 150 UEFI Boot Manager...
... Navigation Keys 138 System Setup Options 139 Memory Settings Screen 140 Processor Settings Screen 141 SATA Settings Screen (PowerEdge M610, M610x 143 Boot Settings Screen 143 Integrated Devices Screen 144 PCI IRQ Assignments Screen 146 Serial Communication Screen 146 Power Management ...Screen (PowerEdge M915, M910, M710, M710HD, M610 and M610x Only 147 System Security Screen 148 Exit Screen 149 Entering the UEFI Boot Manager 150 UEFI Boot Manager...
Hardware Owner's Manual
Page 6
... System Memory - PowerEdge M910 177 System Memory - PowerEdge M610/M610x 199 System Memory - System and Setup Password Features 151 Using the System Password 151 Using the Setup Password 153 3 Installing... 159 Closing the Blade 161 Inside the System 162 System Memory 171 System Memory - PowerEdge M805 184 System Memory - PowerEdge M710HD . . . . . 194 System Memory - PowerEdge M905 181 System Memory - PowerEdge M605 204 System Memory - PowerEdge M710 188 System Memory - PowerEdge M600 210 Installing Memory Modules 213 Removing Memory Modules 214 6 Contents
... System Memory - PowerEdge M910 177 System Memory - PowerEdge M610/M610x 199 System Memory - System and Setup Password Features 151 Using the System Password 151 Using the Setup Password 153 3 Installing... 159 Closing the Blade 161 Inside the System 162 System Memory 171 System Memory - PowerEdge M805 184 System Memory - PowerEdge M710HD . . . . . 194 System Memory - PowerEdge M905 181 System Memory - PowerEdge M605 204 System Memory - PowerEdge M710 188 System Memory - PowerEdge M600 210 Installing Memory Modules 213 Removing Memory Modules 214 6 Contents
Hardware Owner's Manual
Page 13
... Features During Start-up Keystroke Description Enters the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on PowerEdge M610, M610x, M710, M710HD, M910, and M915. Enters System Services, which allows access to the system event log (SEL) and ...Configurator is supported on page 137. Enters PXE boot (if enabled in System Setup program). Enters the SAS Configuration Utility. The Dell USC allows you to access utilities such as embedded system diagnostics. Enters the RAID configuration utility. Boot Mode set to BIOS: Enters...
... Features During Start-up Keystroke Description Enters the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on PowerEdge M610, M610x, M710, M710HD, M910, and M915. Enters System Services, which allows access to the system event log (SEL) and ...Configurator is supported on page 137. Enters PXE boot (if enabled in System Setup program). Enters the SAS Configuration Utility. The Dell USC allows you to access utilities such as embedded system diagnostics. Enters the RAID configuration utility. Boot Mode set to BIOS: Enters...
Hardware Owner's Manual
Page 28
PowerEdge M610 1 6 5 4 3 2 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator 28 About Your System Figure 1-12. Front Panel Features -
PowerEdge M610 1 6 5 4 3 2 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator 28 About Your System Figure 1-12. Front Panel Features -
Hardware Owner's Manual
Page 31
...only if it is installed in the blade. Use the optional external drive storage tray to four hot-swappable 2.5-inch SAS hard drives. • PowerEdge M610, M610x, M600, and M605 support one or two 2.5-inch SATA hard drives or one or two 2.5-inch SAS hard drives. You can be ... or SSD hard drives. • PowerEdge M905 and M805 support one or two hot-swappable 2.5-inch SAS hard drives. • PowerEdge M710HD supports up to connect a USB diskette drive, USB flash drive, USB DVD/CD drive, keyboard, or mouse. NOTE: These blades support only Dell-branded USB 2.0 drives. About Your ...
...only if it is installed in the blade. Use the optional external drive storage tray to four hot-swappable 2.5-inch SAS hard drives. • PowerEdge M610, M610x, M600, and M605 support one or two 2.5-inch SATA hard drives or one or two 2.5-inch SAS hard drives. You can be ... or SSD hard drives. • PowerEdge M905 and M805 support one or two hot-swappable 2.5-inch SAS hard drives. • PowerEdge M710HD supports up to connect a USB diskette drive, USB flash drive, USB DVD/CD drive, keyboard, or mouse. NOTE: These blades support only Dell-branded USB 2.0 drives. About Your ...
Hardware Owner's Manual
Page 139
...integrated devices on the PCI bus, and any installed expansion cards that have keyboards attached. SATA Settings See "SATA Settings Screen (PowerEdge M610, M610x)" on page 144. Using the System Setup Program and UEFI Boot Manager 139 Integrated Devices See "Integrated Devices Screen"...key keyboards). Processor Settings See "Processor Settings Screen" on page 148. Power Management See "Power Management Screen (PowerEdge M915, M910, M710, M710HD, M610 and M610x Only)" on the system configuration. System Setup Options NOTE: The options for host systems that require an IRQ...
...integrated devices on the PCI bus, and any installed expansion cards that have keyboards attached. SATA Settings See "SATA Settings Screen (PowerEdge M610, M610x)" on page 144. Using the System Setup Program and UEFI Boot Manager 139 Integrated Devices See "Integrated Devices Screen"...key keyboards). Processor Settings See "Processor Settings Screen" on page 148. Power Management See "Power Management Screen (PowerEdge M915, M910, M710, M710HD, M610 and M610x Only)" on the system configuration. System Setup Options NOTE: The options for host systems that require an IRQ...
Hardware Owner's Manual
Page 143
... processor(s) can operate in the idle state. Off disables the controller. Setting this (PowerEdge M915, M910, field to BIOS allows compatibility with non-UEFI M710, M710HD, M610, operating systems. and M610x) NOTE: Setting this option to UEFI. SATA Settings Screen (PowerEdge M610, M610x) Option Embedded SATA (ATA Mode default) Port A (Auto default) Port B (Auto...
... processor(s) can operate in the idle state. Off disables the controller. Setting this (PowerEdge M915, M910, field to BIOS allows compatibility with non-UEFI M710, M710HD, M610, operating systems. and M610x) NOTE: Setting this option to UEFI. SATA Settings Screen (PowerEdge M610, M610x) Option Embedded SATA (ATA Mode default) Port A (Auto default) Port B (Auto...
Hardware Owner's Manual
Page 199
...A5, A6, A7, A8, A9, B1, B2, B3, B4, B5, B6, B7, B8, B9 Independent 288 GB channel System Memory - PowerEdge M610/M610x Your system supports DDR3 registered DIMMs (RDIMMS) or unbuffered DIMMs (UDIMMs). Twelve memory sockets are located on the system board, allowing for the ...GB. Single-rank, dual-rank, and quadrank RDIMMs are supported. • 1 GB and 2 GB UDIMMs are supported, for a total of PowerEdge M710HD Memory Configurations (continued) Total Physical Memory 288 GB Memory Modules Memory Module Processors Memory - Installing Blade Components 199 Examples of up to 24 ...
...A5, A6, A7, A8, A9, B1, B2, B3, B4, B5, B6, B7, B8, B9 Independent 288 GB channel System Memory - PowerEdge M610/M610x Your system supports DDR3 registered DIMMs (RDIMMS) or unbuffered DIMMs (UDIMMs). Twelve memory sockets are located on the system board, allowing for the ...GB. Single-rank, dual-rank, and quadrank RDIMMs are supported. • 1 GB and 2 GB UDIMMs are supported, for a total of PowerEdge M710HD Memory Configurations (continued) Total Physical Memory 288 GB Memory Modules Memory Module Processors Memory - Installing Blade Components 199 Examples of up to 24 ...
Hardware Owner's Manual
Page 200
PowerEdge M610/M610x To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: • RDIMMs and UDIMMs cannot be mixed. ... supported. • If memory modules with different speeds are installed, they operate at the speed of the slowest installed memory modules. 200 Installing Blade Components PowerEdge M610/M610x A1 Channel 2 (A1, A4) A4 A2 A5 Channel 1 (A2, A5) A3 A6 Channel 0 (A3, A6) CPU1 CPU2 Channel 0 (B3, B6) B6 B3 Channel 1 (B2...
PowerEdge M610/M610x To ensure optimal performance of your system, observe the following general guidelines when configuring your system memory: • RDIMMs and UDIMMs cannot be mixed. ... supported. • If memory modules with different speeds are installed, they operate at the speed of the slowest installed memory modules. 200 Installing Blade Components PowerEdge M610/M610x A1 Channel 2 (A1, A4) A4 A2 A5 Channel 1 (A2, A5) A3 A6 Channel 0 (A3, A6) CPU1 CPU2 Channel 0 (B3, B6) B6 B3 Channel 1 (B2...
Hardware Owner's Manual
Page 201
... The system supports memory mirroring if identical memory modules are installed in channel 0 and channel 1 (memory is one 128-bit channel. PowerEdge M610/M610x In this configuration, channels 0 and 1 are combined to CPU2. The channels are organized as follows: • Channel 0 - sockets 2, 5 • Channel 2 - Advanced ECC Mode Support - ...
... The system supports memory mirroring if identical memory modules are installed in channel 0 and channel 1 (memory is one 128-bit channel. PowerEdge M610/M610x In this configuration, channels 0 and 1 are combined to CPU2. The channels are organized as follows: • Channel 0 - sockets 2, 5 • Channel 2 - Advanced ECC Mode Support - ...
Hardware Owner's Manual
Page 202
...A3 One Independent 6 GB channel Four 2 GB UDIMMs A2, A3, B2, B3 Two Mirroring 4 GB 202 Installing Blade Components Table 3-10. PowerEdge M610/M610x In this mode, all three channels are populated with identical memory modules. This mode permits a larger total memory capacity, but does not ...support the reliability features of PowerEdge M610/M610x Memory Configurations Total Physical Memory 1 GB 2 GB 2 GB 4 GB 4 GB 4 GB 4 GB 6 GB 6 GB 8 GB Memory Modules ...
...A3 One Independent 6 GB channel Four 2 GB UDIMMs A2, A3, B2, B3 Two Mirroring 4 GB 202 Installing Blade Components Table 3-10. PowerEdge M610/M610x In this mode, all three channels are populated with identical memory modules. This mode permits a larger total memory capacity, but does not ...support the reliability features of PowerEdge M610/M610x Memory Configurations Total Physical Memory 1 GB 2 GB 2 GB 4 GB 4 GB 4 GB 4 GB 6 GB 6 GB 8 GB Memory Modules ...
Hardware Owner's Manual
Page 203
Examples of PowerEdge M610/M610x Memory Configurations (continued) Total Physical Memory 8 GB 8 GB 8 GB 12 GB 12 GB 16 GB 16 GB 24 GB 24 GB 32 GB 32 ...
Examples of PowerEdge M610/M610x Memory Configurations (continued) Total Physical Memory 8 GB 8 GB 8 GB 12 GB 12 GB 16 GB 16 GB 24 GB 24 GB 32 GB 32 ...
Hardware Owner's Manual
Page 204
... to a maximum of 16 GB (single processor) or 32 GB (dual processors) by installing 667 or 800 MHz registered DDR2 memory modules in sets of PowerEdge M610/M610x Memory Configurations (continued) Total Physical Memory 96 GB 128 GB 128 GB 192 GB Memory Modules Memory Module Processors Memory - Table 3-10.
... to a maximum of 16 GB (single processor) or 32 GB (dual processors) by installing 667 or 800 MHz registered DDR2 memory modules in sets of PowerEdge M610/M610x Memory Configurations (continued) Total Physical Memory 96 GB 128 GB 128 GB 192 GB Memory Modules Memory Module Processors Memory - Table 3-10.
Hardware Owner's Manual
Page 219
...slot C supports Fabric C. x8 PCIe Gen 1 and x4 PCIe Gen 2 cards are supported. x8 PCIe Gen 1 and x8 PCIe Gen 2 cards are supported. • PowerEdge M610 supports two SFF or one SFF card and one LFF mezzanine card. See Figure 3-24 or Figure 3-25. This card must match the fabric type... installed in I /O module bays C1 and C2. • Mezzanine card slot B supports Fabric B. x8 PCIe Gen 1 and x4 PCIe Gen 2 cards are supported. • PowerEdge M605 and M600 support two LFF x8 PCIe Gen 1 mezzanine cards. See "Opening the Blade" on page 159. 3 Open the mezzanine card latch by pressing...
...slot C supports Fabric C. x8 PCIe Gen 1 and x4 PCIe Gen 2 cards are supported. x8 PCIe Gen 1 and x8 PCIe Gen 2 cards are supported. • PowerEdge M610 supports two SFF or one SFF card and one LFF mezzanine card. See Figure 3-24 or Figure 3-25. This card must match the fabric type... installed in I /O module bays C1 and C2. • Mezzanine card slot B supports Fabric B. x8 PCIe Gen 1 and x4 PCIe Gen 2 cards are supported. • PowerEdge M605 and M600 support two LFF x8 PCIe Gen 1 mezzanine cards. See "Opening the Blade" on page 159. 3 Open the mezzanine card latch by pressing...
Hardware Owner's Manual
Page 230
Figure 3-32. Removing or Installing the RAID Battery (PowerEdge M610/M610x Only) 1 2 3 4 5 1 RAID battery cable 3 tabs (3) 5 storage controller card 2 RAID battery 4 metal standoffs (3) 230 Installing Blade Components
Figure 3-32. Removing or Installing the RAID Battery (PowerEdge M610/M610x Only) 1 2 3 4 5 1 RAID battery cable 3 tabs (3) 5 storage controller card 2 RAID battery 4 metal standoffs (3) 230 Installing Blade Components