Information Update - Intel Xeon 5600 Series Processors
Page 1
... the BIOS and iDRAC firmware for the Intel Xeon 5600 series processor at support.dell.com. M610 - T610 - M710 NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W Intel Xeon 5600 series processors. NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W Intel Xeon X5680 only in the 130 W processor...
... the BIOS and iDRAC firmware for the Intel Xeon 5600 series processor at support.dell.com. M610 - T610 - M710 NOTE: The PowerEdge R410, T410, and R510 systems do not support 130 W Intel Xeon 5600 series processors. NOTE: The modular systems, PowerEdge M610 and M710, support the 130 W Intel Xeon X5680 only in the 130 W processor...
Information Update - Intel Xeon 5600 Series Processors
Page 4
...: Displays the amount of the system setup, the feature can be enabled or disabled using the following BIOS setup options: NOTE: The Dell BIOS Intelligent Turbo Mode is disabled when the turbo mode is detected on an old system board (systems not marked with roman numeral II...Dell BIOS Intelligent Turbo Mode The Dell BIOS Intelligent Turbo Mode feature allows the operating system to set the processor performance in the processor system setup screen. New POST Messages The following are the new POST messages for better power management. When the turbo mode is detected on PowerEdge M610...
...: Displays the amount of the system setup, the feature can be enabled or disabled using the following BIOS setup options: NOTE: The Dell BIOS Intelligent Turbo Mode is disabled when the turbo mode is detected on an old system board (systems not marked with roman numeral II...Dell BIOS Intelligent Turbo Mode The Dell BIOS Intelligent Turbo Mode feature allows the operating system to set the processor performance in the processor system setup screen. New POST Messages The following are the new POST messages for better power management. When the turbo mode is detected on PowerEdge M610...
Information Update - Intel Xeon 5600 Series Processors
Page 10
... DIMM detected on DIMM XX II Intel Xeon 5600 130 W • 在 PowerEdge M610 和 M710 Intel Xeon X5677 130 W ECC 启用 Dell BIOS 智能 Turbo 模式 Dell BIOS 智能 Turbo turbo turbo Processor Settings turbo BIOS turbo Dell BIOS 智能 Turbo 模式。 电源管理 电...
... DIMM detected on DIMM XX II Intel Xeon 5600 130 W • 在 PowerEdge M610 和 M710 Intel Xeon X5677 130 W ECC 启用 Dell BIOS 智能 Turbo 模式 Dell BIOS 智能 Turbo turbo turbo Processor Settings turbo BIOS turbo Dell BIOS 智能 Turbo 模式。 电源管理 电...
Information Update - Intel Xeon 5600 Series Processors
Page 30
Hardware Prefetcher Enabled DCU Streamer Prefetcher (DCU Enabled Data Reuse Enabled DCU HPC HPC POST Intel Xeon 5600 POST 説明 System Memory Size X.X GB, System Memory Speed: XXX MHz, ます。 Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX Intel Xeon 5600 130 W II • PowerEdge M610/M710 で Intel Xeon X5677 130 W 非 ECC
Hardware Prefetcher Enabled DCU Streamer Prefetcher (DCU Enabled Data Reuse Enabled DCU HPC HPC POST Intel Xeon 5600 POST 説明 System Memory Size X.X GB, System Memory Speed: XXX MHz, ます。 Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX Intel Xeon 5600 130 W II • PowerEdge M610/M710 で Intel Xeon X5677 130 W 非 ECC
Information Update - Intel Xeon 5600 Series Processors
Page 36
옵션 Data Reuse Enabled(활성화)) 설명 HPC 새 POST 메시지 다음은 Intel Xeon 5600 POST 메시지 설명 System Memory Size X.X GB, System Memory Speed: XXX MHz, Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX II Intel Xeon 5600 130W • PowerEdge M610 및 M710 에서 Intel Xeon X5677 130W ECC
옵션 Data Reuse Enabled(활성화)) 설명 HPC 새 POST 메시지 다음은 Intel Xeon 5600 POST 메시지 설명 System Memory Size X.X GB, System Memory Speed: XXX MHz, Voltage: 1.5V or 1.35V This CPU power rating is not supported Non-ECC DIMM detected on DIMM XX II Intel Xeon 5600 130W • PowerEdge M610 및 M710 에서 Intel Xeon X5677 130W ECC
Information Update
Page 10
..., M805, or M905 blades. 10 Information Update The PowerEdge M610 and M710 blades require OpenManage systems management software version 6.0.1 or later. Dell™ OpenManage™ Version Requirements The PowerEdge M905 and M805 blades require OpenManage systems management software version 5.4.3 or later. NOTE: OpenManage version 5.4.3 does not support PowerEdge M600 or M605 blades. Blade 8 A1 Integrated...
..., M805, or M905 blades. 10 Information Update The PowerEdge M610 and M710 blades require OpenManage systems management software version 6.0.1 or later. Dell™ OpenManage™ Version Requirements The PowerEdge M905 and M805 blades require OpenManage systems management software version 5.4.3 or later. NOTE: OpenManage version 5.4.3 does not support PowerEdge M600 or M605 blades. Blade 8 A1 Integrated...
Information Update
Page 11
The following software components are included with an older CMC firmware version, the new blades will retain the current CMC settings. PowerEdge M610 and M710 blades require CMC firmware version 2.0 or later. If you have the option to reset the CMC configuration settings back ...Firmware Update page to update the CMC firmware to an M1000e enclosure with your local system. NOTE: See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on . Information Update 11 During the update process, you add these blades to the latest ...
The following software components are included with an older CMC firmware version, the new blades will retain the current CMC settings. PowerEdge M610 and M710 blades require CMC firmware version 2.0 or later. If you have the option to reset the CMC configuration settings back ...Firmware Update page to update the CMC firmware to an M1000e enclosure with your local system. NOTE: See the latest Dell Chassis Management Controller User's Guide at support.dell.com for complete instructions on . Information Update 11 During the update process, you add these blades to the latest ...
Information Update
Page 21
... immediately lost after the hard drive is powered on Hard Drive Installation • The PowerEdge M805 and M905 blades support one or two 2.5-inch SAS hard-disk drives. • The PowerEdge M710 blade supports one to maintain proper cooling airflow. See the documentation supplied with the... SATA repeater daughter card. NOTE: SAS and SATA hard drives cannot be installed to four 2.5 inch SAS hard drives. • The PowerEdge M610, M600 and M605 blades support one or two solid-state disk (SSD) hard drives. Information Update 21 Updates on , the hard drive automatically...
... immediately lost after the hard drive is powered on Hard Drive Installation • The PowerEdge M805 and M905 blades support one or two 2.5-inch SAS hard-disk drives. • The PowerEdge M710 blade supports one to maintain proper cooling airflow. See the documentation supplied with the... SATA repeater daughter card. NOTE: SAS and SATA hard drives cannot be installed to four 2.5 inch SAS hard drives. • The PowerEdge M610, M600 and M605 blades support one or two solid-state disk (SSD) hard drives. Information Update 21 Updates on , the hard drive automatically...
Information Update
Page 153
• PowerEdge M805 및 M905 1 - 2 개의 2.5 인치 SAS • PowerEdge M710 1 - 4 개의 2.5 인치 SAS • PowerEdge M610, M600 및 M605 1 - 2 개의 2.5 인치 SATA 1 - 2 개의 2.5 인치 SAS 1 - 2 개의 SSD(Solid State Disk 주 : SAS 와 SATA RAID 주 : SATA SATA • RAID 153
• PowerEdge M805 및 M905 1 - 2 개의 2.5 인치 SAS • PowerEdge M710 1 - 4 개의 2.5 인치 SAS • PowerEdge M610, M600 및 M605 1 - 2 개의 2.5 인치 SATA 1 - 2 개의 2.5 인치 SAS 1 - 2 개의 SSD(Solid State Disk 주 : SAS 와 SATA RAID 주 : SATA SATA • RAID 153
Getting Started Guide
Page 15
... card. or Up to two 2.5-inch SSD hard-disk drives support through value RAID or performance RAID storage card. Memory (continued) Maximum RAM PowerEdge M910 PowerEdge M905 PowerEdge M805 PowerEdge M710HD PowerEdge M710 PowerEdge M610, M610x PowerEdge M600, M605 512 GB 192 GB 128 GB 144 GB (dual-rank DIMMs) or 192 GB (quad-rank DIMMs) 192 GB (12...
... card. or Up to two 2.5-inch SSD hard-disk drives support through value RAID or performance RAID storage card. Memory (continued) Maximum RAM PowerEdge M910 PowerEdge M905 PowerEdge M805 PowerEdge M710HD PowerEdge M710 PowerEdge M610, M610x PowerEdge M600, M605 512 GB 192 GB 128 GB 144 GB (dual-rank DIMMs) or 192 GB (quad-rank DIMMs) 192 GB (12...
Dell PowerEdge M1000e Configuration Guide
Page 20
Front Panel Features-PowerEdge M610 1 6 5 4 3 2 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator 20 About Your System Figure 1-12.
Front Panel Features-PowerEdge M610 1 6 5 4 3 2 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator 20 About Your System Figure 1-12.
Hardware Owner's Manual
Page 5
... Keys 128 System Setup Options 129 Memory Settings Screen 130 Processor Settings Screen 131 SATA Settings Screen (PowerEdge M610, M610x 132 Boot Settings Screen 133 Integrated Devices Screen 133 PCI IRQ Assignments Screen 135 Serial Communication Screen 135 Power Management Screen...(PowerEdge M910, M710, M710HD, M610 and M610x Only 136 System Security Screen 137 Exit Screen 138 Entering the UEFI Boot Manager 139 UEFI Boot Manager Screen...
... Keys 128 System Setup Options 129 Memory Settings Screen 130 Processor Settings Screen 131 SATA Settings Screen (PowerEdge M610, M610x 132 Boot Settings Screen 133 Integrated Devices Screen 133 PCI IRQ Assignments Screen 135 Serial Communication Screen 135 Power Management Screen...(PowerEdge M910, M710, M710HD, M610 and M610x Only 136 System Security Screen 137 Exit Screen 138 Entering the UEFI Boot Manager 139 UEFI Boot Manager Screen...
Hardware Owner's Manual
Page 6
... Mezzanine Interface Card . . . . . 196 Installing the Mezzanine Interface Card . . . . . 198 I/O Module Mezzanine Cards 198 Installing a Mezzanine Card 200 Removing a Mezzanine Card 203 6 Contents PowerEdge M710HD . . . . . 176 System Memory - PowerEdge M610/M610x . . . 181 System Memory - 3 Installing Blade Components 145 Recommended Tools 145 Removing and Installing a Blade 145 Removing a Blade 145 Installing a Blade 148 Removing and...
... Mezzanine Interface Card . . . . . 196 Installing the Mezzanine Interface Card . . . . . 198 I/O Module Mezzanine Cards 198 Installing a Mezzanine Card 200 Removing a Mezzanine Card 203 6 Contents PowerEdge M710HD . . . . . 176 System Memory - PowerEdge M610/M610x . . . 181 System Memory - 3 Installing Blade Components 145 Recommended Tools 145 Removing and Installing a Blade 145 Removing a Blade 145 Installing a Blade 148 Removing and...
Hardware Owner's Manual
Page 11
6 Running System Diagnostics 303 Dell PowerEdge Diagnostics 303 System Diagnostics Features 303 When to Use the System Diagnostics 304 Running the System Diagnostics 304 Running the Embedded...PowerEdge M910 Jumper Settings 309 PowerEdge M905 Jumper Settings 310 PowerEdge M805 Jumper Settings 311 PowerEdge M710 Jumper Settings 312 PowerEdge M710HD Jumper Settings 313 PowerEdge M610/M610x Jumper Settings. . . . . 314 PowerEdge M600 Jumper Settings 315 System Board Connectors 316 PowerEdge M910 System Board 316 PowerEdge M905 System Board 318 PowerEdge M805 System Board 320 PowerEdge...
6 Running System Diagnostics 303 Dell PowerEdge Diagnostics 303 System Diagnostics Features 303 When to Use the System Diagnostics 304 Running the System Diagnostics 304 Running the Embedded...PowerEdge M910 Jumper Settings 309 PowerEdge M905 Jumper Settings 310 PowerEdge M805 Jumper Settings 311 PowerEdge M710 Jumper Settings 312 PowerEdge M710HD Jumper Settings 313 PowerEdge M610/M610x Jumper Settings. . . . . 314 PowerEdge M600 Jumper Settings 315 System Board Connectors 316 PowerEdge M910 System Board 316 PowerEdge M905 System Board 318 PowerEdge M805 System Board 320 PowerEdge...
Hardware Owner's Manual
Page 28
Front Panel Features - Figure 1-12. PowerEdge M610 1 6 5 4 3 2 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator 28 About Your System
Front Panel Features - Figure 1-12. PowerEdge M610 1 6 5 4 3 2 1 blade handle release button 2 hard drives (2) 3 blade status/identification indicator 4 USB connectors (2) 5 blade power button 6 blade power indicator 28 About Your System
Hardware Owner's Manual
Page 30
...DVD/CD Drives Each blade has USB ports on page 127). NOTE: These blades support only Dell-branded USB 2.0 drives. You can be horizontal and level to configure the blade. Hard-Drive Features • The PowerEdge M910 blades support up to two 2.5-inch SAS, SATA, or solid-state disk (SSD) ... or mouse. Use the optional external drive storage tray to the system before you to four hot-swappable 2.5-inch SAS hard drives. • The PowerEdge M610, M610x, M600, and M605 blades support one or two 2.5-inch SATA hard drives or one or two hot-swappable 2.5-inch SAS hard drives. • The...
...DVD/CD Drives Each blade has USB ports on page 127). NOTE: These blades support only Dell-branded USB 2.0 drives. You can be horizontal and level to configure the blade. Hard-Drive Features • The PowerEdge M910 blades support up to two 2.5-inch SAS, SATA, or solid-state disk (SSD) ... or mouse. Use the optional external drive storage tray to the system before you to four hot-swappable 2.5-inch SAS hard drives. • The PowerEdge M610, M610x, M600, and M605 blades support one or two 2.5-inch SATA hard drives or one or two hot-swappable 2.5-inch SAS hard drives. • The...
Hardware Owner's Manual
Page 129
...system configuration. System Setup Options NOTE: The options for host systems that require an IRQ. SATA Settings See "SATA Settings Screen (PowerEdge M610, M610x)" on page 133. Integrated Devices See "Integrated Devices Screen" on page 132. Serial Communication See "Serial Communication Screen" on ...page 136. Power Management See "Power Management Screen (PowerEdge M910, M710, M710HD, M610 and M610x Only)" on page 135. or 102-key keyboards (does not apply to the system. Select Report for the ...
...system configuration. System Setup Options NOTE: The options for host systems that require an IRQ. SATA Settings See "SATA Settings Screen (PowerEdge M610, M610x)" on page 133. Integrated Devices See "Integrated Devices Screen" on page 132. Serial Communication See "Serial Communication Screen" on ...page 136. Power Management See "Power Management Screen (PowerEdge M910, M710, M710HD, M610 and M610x Only)" on page 135. or 102-key keyboards (does not apply to the system. Select Report for the ...
Hardware Owner's Manual
Page 132
... of each processor are enabled. Auto enables BIOS support for the device. 132 Using the System Setup Program and UEFI Boot Manager SATA Settings Screen (PowerEdge M610, M610x) Option Embedded SATA (ATA Mode default) Port A (Auto default) Port B (Auto default) Description ATA Mode enables the integrated SATA controller. Off disables BIOS support for...
... of each processor are enabled. Auto enables BIOS support for the device. 132 Using the System Setup Program and UEFI Boot Manager SATA Settings Screen (PowerEdge M610, M610x) Option Embedded SATA (ATA Mode default) Port A (Auto default) Port B (Auto default) Description ATA Mode enables the integrated SATA controller. Off disables BIOS support for...
Hardware Owner's Manual
Page 181
PowerEdge M610/M610x Your system supports DDR3 registered DIMMs (RDIMMS) or unbuffered DIMMs (UDIMMs). Single-rank, dual-rank, and quadrank RDIMMs are supported. • 1 GB and 2 GB UDIMMs ...: • RDIMMs and UDIMMs cannot be mixed. • Memory modules are supported, for a total of up to 24 GB. PowerEdge M610//M610x To ensure optimal performance of up to 192 GB. Installing Blade Components 181 PowerEdge M610/M610x A1 Channel 2 (A1, A4) A4 A2 A5 Channel 1 (A2, A5) A3 A6 Channel 0 (A3, A6) CPU1 CPU2 Channel...
PowerEdge M610/M610x Your system supports DDR3 registered DIMMs (RDIMMS) or unbuffered DIMMs (UDIMMs). Single-rank, dual-rank, and quadrank RDIMMs are supported. • 1 GB and 2 GB UDIMMs ...: • RDIMMs and UDIMMs cannot be mixed. • Memory modules are supported, for a total of up to 24 GB. PowerEdge M610//M610x To ensure optimal performance of up to 192 GB. Installing Blade Components 181 PowerEdge M610/M610x A1 Channel 2 (A1, A4) A4 A2 A5 Channel 1 (A2, A5) A3 A6 Channel 0 (A3, A6) CPU1 CPU2 Channel...
Hardware Owner's Manual
Page 182
...memory is not installed in channel 2). sockets 3, 6 • Channel 1 - Memory modules must also be enabled in corresponding slots. PowerEdge M610/M610x The system supports memory mirroring if identical memory modules are organized as follows: • Channel 0 - In a mirrored configuration, the total...Three memory channels are assigned to CPU2. sockets B1 through A6 are assigned to CPU1; sockets 2, 5 • Channel 2 - PowerEdge M610/M610x In this configuration, channels 0 and 1 are installed, they operate at the speed of the slowest installed memory modules. • ...
...memory is not installed in channel 2). sockets 3, 6 • Channel 1 - Memory modules must also be enabled in corresponding slots. PowerEdge M610/M610x The system supports memory mirroring if identical memory modules are organized as follows: • Channel 0 - In a mirrored configuration, the total...Three memory channels are assigned to CPU2. sockets B1 through A6 are assigned to CPU1; sockets 2, 5 • Channel 2 - PowerEdge M610/M610x In this configuration, channels 0 and 1 are installed, they operate at the speed of the slowest installed memory modules. • ...