Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 15
.... To access the Online Help, click Help on the CMC web interface. • The Chassis Management Controller for PowerEdge FX2/FX2s User's Guide provides information about using the VRTX-related Web interface features. • The Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2/FX2s Version Release Notes provides last-minute updates to the system or documentation or advanced technical...
.... To access the Online Help, click Help on the CMC web interface. • The Chassis Management Controller for PowerEdge FX2/FX2s User's Guide provides information about using the VRTX-related Web interface features. • The Dell Chassis Management Controller (CMC) for Dell PowerEdge FX2/FX2s Version Release Notes provides last-minute updates to the system or documentation or advanced technical...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 18
... for a subcommand arp -- display the networking arp table chassisaction -- modify network configuration properties setractime -- set the chassis name and chassis location sslcertview -- sets the name of the slot in the CMC sslcsrgen -- "?"and "?" Descriptions shown in this...string that contains the special characters, $, ",',`and \. NOTE: An empty string may vary slightly from the CMC testemail -- execute chassis or switch power-up/down/cycle or clrraclog -- setniccfg -- generate a certificate CSR from the descriptions in your racadm session. racadm...
... for a subcommand arp -- display the networking arp table chassisaction -- modify network configuration properties setractime -- set the chassis name and chassis location sslcertview -- sets the name of the slot in the CMC sslcsrgen -- "?"and "?" Descriptions shown in this...string that contains the special characters, $, ",',`and \. NOTE: An empty string may vary slightly from the CMC testemail -- execute chassis or switch power-up/down/cycle or clrraclog -- setniccfg -- generate a certificate CSR from the descriptions in your racadm session. racadm...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 19
... help . display general CMC and system information Usage: racadm getsysinfo [-d] [-c] [-A] [-4] [-6 Valid Options: -d : show CMC information -c : show chassis information -A : do not show headers or labels -4 : show CMC IPv4 information -6 : show CMC IPv6 information help and help Description Synopsis Input Output...must have the Clear Logs Administrator previlege. 19 test CMC SNMP trap notifications -- To clear a chassis log, you to view, export, or clear the chassis log history. getsysinfo getsysinfo -- racadm ? command displays information for the specified object. racadm help...
... help . display general CMC and system information Usage: racadm getsysinfo [-d] [-c] [-A] [-4] [-6 Valid Options: -d : show CMC information -c : show chassis information -A : do not show headers or labels -4 : show CMC IPv4 information -6 : show CMC IPv6 information help and help Description Synopsis Input Output...must have the Clear Logs Administrator previlege. 19 test CMC SNMP trap notifications -- To clear a chassis log, you to view, export, or clear the chassis log history. getsysinfo getsysinfo -- racadm ? command displays information for the specified object. racadm help...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 20
...chassislog view -r "2011-01-02 23:33:40" -e "2011-01-03 00:32:15" • Display all the available records from the active Chassis log: racadm chassislog view -n all • Display the last 25 records from which the records must be provided within double quotes. • -s -... the delimiter. Critical - 3. Updates - Displays events that have occurred before this subcommand. Config • -q - Info NOTE: To view or export the Chassis log, only CMC Login User permission is required. • Display the number of records present in the active log. The severity used to run this...
...chassislog view -r "2011-01-02 23:33:40" -e "2011-01-03 00:32:15" • Display all the available records from the active Chassis log: racadm chassislog view -n all • Display the last 25 records from which the records must be provided within double quotes. • -s -... the delimiter. Critical - 3. Updates - Displays events that have occurred before this subcommand. Config • -q - Info NOTE: To view or export the Chassis log, only CMC Login User permission is required. • Display the number of records present in the active log. The severity used to run this...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 21
... calvin (user password). 21 p -l • -f : Filename of the exported Chassis Log. • -u : Username for NFS or CIFS share) to where the Chassis Log must have the Clear Logs Administrator privilege. To clear the chassis log, you must have the Clear Logs Administrator privilege. chassislog export Description Exports the... be given as domain/username • -p : Password for the remote share to where the file must be exported. • Export the Chassis Log to a remote CIFS share racadm chassislog export -f Mylog.xml -u admin -p mypass -l //10.94.161.103/share • Export the...
... calvin (user password). 21 p -l • -f : Filename of the exported Chassis Log. • -u : Username for NFS or CIFS share) to where the Chassis Log must have the Clear Logs Administrator privilege. To clear the chassis log, you must have the Clear Logs Administrator privilege. chassislog export Description Exports the... be given as domain/username • -p : Password for the remote share to where the file must be exported. • Export the Chassis Log to a remote CIFS share racadm chassislog export -f Mylog.xml -u admin -p mypass -l //10.94.161.103/share • Export the...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 22
...• -u - Module on which can be retrieved using this command. powerdown - (Chassis only) Turns off the chassis. - nongraceshutdown - (Chassis only) Non-gracefully turns off the chassis. - reset - Use the getssninfo command to view a list of the session to ...that can be closed using RACADM getssninfo subcommand. powercycle - chassis - closessn Description Synopsis Input Closes a communication session on the chassis or a server. Session executing this subcommand, you want to 2 • - powerup - (Chassis only) Turns on the specified module. Performs a hard...
...• -u - Module on which can be retrieved using this command. powerdown - (Chassis only) Turns off the chassis. - nongraceshutdown - (Chassis only) Non-gracefully turns off the chassis. - reset - Use the getssninfo command to view a list of the session to ...that can be closed using RACADM getssninfo subcommand. powercycle - chassis - closessn Description Synopsis Input Closes a communication session on the chassis or a server. Session executing this subcommand, you want to 2 • - powerup - (Chassis only) Turns on the specified module. Performs a hard...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 25
... on the server. Specify the value as server or switch. Legal values: For switches, valid passwords are 6 - 32 ASCII characters in length, ranging in the chassis of the following values: - A string representing a valid subnet mask. Use with -a for an individual server, or with -m to all servers • -a - The -s and -d options cannot...
... on the server. Specify the value as server or switch. Legal values: For switches, valid passwords are 6 - 32 ASCII characters in length, ranging in the chassis of the following values: - A string representing a valid subnet mask. Use with -a for an individual server, or with -m to all servers • -a - The -s and -d options cannot...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 28
... feature. Minimum speed for fan is 35% of the SD card used to activate the feature. NOTE: To deactivate FlexAddress features, the chassis must have the Chassis Configuration Administrator privilege. fanoffset Description Synopsis Input Example feature Description Synopsis 28 • Configure the event generation interval and notifications for temperature statistics:... to run at a higher speed than one feature. The information displayed includes feature name, date activated, and the serial number of the maximum. Dell Feature Cards may contain more than the normal speed.
... feature. Minimum speed for fan is 35% of the SD card used to activate the feature. NOTE: To deactivate FlexAddress features, the chassis must have the Chassis Configuration Administrator privilege. fanoffset Description Synopsis Input Example feature Description Synopsis 28 • Configure the event generation interval and notifications for temperature statistics:... to run at a higher speed than one feature. The information displayed includes feature name, date activated, and the serial number of the maximum. Dell Feature Cards may contain more than the normal speed.
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 29
must have the Chassis Configuration Administrator privilege. An example of output is not affected by providing an IP address and optional path. 29 You can: • Check the ...(with -d) ExtendedStorage (with -d or r) Verifies proper SD card installation and displays the SD card status. To use this subcommand, you to update the CMC firmware, chassis infrastructure firmware. racadm featurecard -s -s - Deactivates the feature specified in the CMC cardslot. Any existing ExtendedStorage data will be deactivated. Repair damaged/unformatted ExtendedStorage media. Displays...
must have the Chassis Configuration Administrator privilege. An example of output is not affected by providing an IP address and optional path. 29 You can: • Check the ...(with -d) ExtendedStorage (with -d or r) Verifies proper SD card installation and displays the SD card status. To use this subcommand, you to update the CMC firmware, chassis infrastructure firmware. racadm featurecard -s -s - Deactivates the feature specified in the CMC cardslot. Any existing ExtendedStorage data will be deactivated. Repair damaged/unformatted ExtendedStorage media. Displays...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 30
... if the host system is displayed. • Using Remote RACADM: racadm fwupdate -p -u -d NOTE: iDRAC7 targets are not supported from CMC. The -u option must have the Chassis Configuration Administrator privilege.
... if the host system is displayed. • Using Remote RACADM: racadm fwupdate -p -u -d NOTE: iDRAC7 targets are not supported from CMC. The -u option must have the Chassis Configuration Administrator privilege.
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 32
... to complete. racadm fwupdate -s -m cmc-active Invalid firmware: The uploaded firmware image does not contain A verification signature. NOTE: Currently, these commands are supported only in a chassis. 32 The following table describes the firmware update methods supported for each interface.
... to complete. racadm fwupdate -s -m cmc-active Invalid firmware: The uploaded firmware image does not contain A verification signature. NOTE: Currently, these commands are supported only in a chassis. 32 The following table describes the firmware update methods supported for each interface.
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 33
... for : server-n, where n = 1 to 4 switch-n, where n = 1 to 2 cmc-n, where n = 1 fan-n, where n = 1 to view. Specifies the module whose asset tag you want to 8 ps-n, where n = 1 or 2 chassis Display entire log: racadm getactiveerrors - Synopsis racadm getchassisname 33 racadm getassettag [-m ] -m < module > - Display specific module log: racadm getactiveerrors -m server-1 - racadm getactiveerrors [-s ] [-m ] valid values for : critical...
... for : server-n, where n = 1 to 4 switch-n, where n = 1 to 2 cmc-n, where n = 1 fan-n, where n = 1 to view. Specifies the module whose asset tag you want to 8 ps-n, where n = 1 or 2 chassis Display entire log: racadm getactiveerrors - Synopsis racadm getchassisname 33 racadm getassettag [-m ] -m < module > - Display specific module log: racadm getactiveerrors -m server-1 - racadm getactiveerrors [-s ] [-m ] valid values for : critical...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 35
...with verbose information for a system with multi-slot servers. Only the CMC controls daughtercards. NOTE: Fabric verification for server DCs is performed only when the chassis is on stand-by power, iDRACs on . racadm getdcinfo Group A I/O Type : Gigabit Ethernet Group B I/O Type : PCIe Group C I /O ...module and daughter card configuration information. When the chassis is turned on the server modules remain turned off and thus are unable to report the server's DC fabric type. Example The following example is...
...with verbose information for a system with multi-slot servers. Only the CMC controls daughtercards. NOTE: Fabric verification for server DCs is performed only when the chassis is on stand-by power, iDRACs on . racadm getdcinfo Group A I/O Type : Gigabit Ethernet Group B I/O Type : PCIe Group C I /O ...module and daughter card configuration information. When the chassis is turned on the server modules remain turned off and thus are unable to report the server's DC fabric type. Example The following example is...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 36
... A2 Link Status = 5 = Up = Down Port No A1 Link Status A2 Link Status = 4 = Up = Up getflexaddr Description Displays enabled or disabled status for the entire chassis. If used with -i, the command displays MACs/WWN on a per-slot-basis.
... A2 Link Status = 5 = Up = Down Port No A1 Link Status A2 Link Status = 4 = Up = Up getflexaddr Description Displays enabled or disabled status for the entire chassis. If used with -i, the command displays MACs/WWN on a per-slot-basis.
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 37
Synopsis Input To use this subcommand, you must be from 1 to 4. If the slot is not activated on the chassis, the command displays server-assigned MAC/WWN addresses. racadm getflexaddr -i 1 Slot-1 server presence = Present Slot-1 flexaddress enabled = 1 37 If an external console controls the MAC/...
Synopsis Input To use this subcommand, you must be from 1 to 4. If the slot is not activated on the chassis, the command displays server-assigned MAC/WWN addresses. racadm getflexaddr -i 1 Slot-1 server presence = Present Slot-1 flexaddress enabled = 1 37 If an external console controls the MAC/...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 38
slot1 Controller aidrac slot1 10 GbE - KR A2 00:90:FA: 51:31:E7 00:90:FA: 51:31:E7 00:90:FA: 51:31:E9 00:90:FA: 51:31:EA 10 GbE KR 00:90:FA:51:31:EB F0:1F:AF:88:21:A0(active) F0:1F:AF:88:21:A1(active) F0:1F:AF:88:21:A3(active) 20:01:F0:1F:AF:88:21:A3(active) F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:73(active) F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:75(active) F0:1F:AF:88:22:77(active) F0:1F:AF:88:22:7B(active) F0:1F:AF:88:22:7D(active) F0:1F:AF:88:21:A2(active) F0:1F:AF:88:21:A4(active) 38 KR A1 18:...
slot1 Controller aidrac slot1 10 GbE - KR A2 00:90:FA: 51:31:E7 00:90:FA: 51:31:E7 00:90:FA: 51:31:E9 00:90:FA: 51:31:EA 10 GbE KR 00:90:FA:51:31:EB F0:1F:AF:88:21:A0(active) F0:1F:AF:88:21:A1(active) F0:1F:AF:88:21:A3(active) 20:01:F0:1F:AF:88:21:A3(active) F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:73(active) F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:75(active) 20:01:F0:1F:AF:88:22:75(active) F0:1F:AF:88:22:77(active) F0:1F:AF:88:22:7B(active) F0:1F:AF:88:22:7D(active) F0:1F:AF:88:21:A2(active) F0:1F:AF:88:21:A4(active) 38 KR A1 18:...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 39
NOTE: The fabric type may be any supported I /O modules on the chassis. The value 3 indicates the protocol type. getioinfo Description Synopsis Displays general information about the I /O fabric type, such as Ethernet, Fiber Channel, and Infiniband. To use ...
NOTE: The fabric type may be any supported I /O modules on the chassis. The value 3 indicates the protocol type. getioinfo Description Synopsis Displays general information about the I /O fabric type, such as Ethernet, Fiber Channel, and Infiniband. To use ...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 40
... the Type column indicate the protocols of the following: • server-n where n=1 or 4 • switch-n where n=1 or 2 • chassis • CMC active For CMC: • racadm getled -m server-4 server-4 Blinking • racadm getled -m chassis server-4 Not blinking • racadm getled -m server-1 server-1 ON • racadm getled -m server-1 server-1 Extension(1) getmacaddress Description Displays...
... the Type column indicate the protocols of the following: • server-n where n=1 or 4 • switch-n where n=1 or 2 • chassis • CMC active For CMC: • racadm getled -m server-4 server-4 Blinking • racadm getled -m chassis server-4 Not blinking • racadm getled -m server-1 server-1 ON • racadm getled -m server-1 server-1 Extension(1) getmacaddress Description Displays...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 41
... iSCSI MACs for all LOMs or mezzanine cards. Displays the extra MACs (Ethernet or iSCSI) for a particular slot, then the chassis-assigned MAC/WWN address is enabled for servers with -m option. • -a - When FlexAddress is displayed. • -c- IO-Identity ... specified server if used with additional LOM MACs and must have the CMC Login User privilege. • racadm getmacaddress • racadm getmacaddress -m chassis • racadm getmacaddress -m switch- • racadm getmacaddress [-m ] [-t iscsi] [-x] • racadm getmacaddress [-a] • racadm getmacaddress -c...
... iSCSI MACs for all LOMs or mezzanine cards. Displays the extra MACs (Ethernet or iSCSI) for a particular slot, then the chassis-assigned MAC/WWN address is enabled for servers with -m option. • -a - When FlexAddress is displayed. • -c- IO-Identity ... specified server if used with additional LOM MACs and must have the CMC Login User privilege. • racadm getmacaddress • racadm getmacaddress -m chassis • racadm getmacaddress -m switch- • racadm getmacaddress [-m ] [-t iscsi] [-x] • racadm getmacaddress [-a] • racadm getmacaddress -c...
Dell PowerEdge FX2 and FX2s Enclosure Owners Manual
Page 42
... getmacaddress -m server-1 -x 42 racadm getmacaddress -c flexaddress • Displays the MAC/WWN addresses for all • Displays the chassis assigned WWN/MAC address. racadm getmacaddress -m chassis CMC Present N/A 74:86:7A:D5:33: N/A 44 Displays the MAC address for switch -1 racadm getmacaddress -m switch-1 Switch...:DB:88:3E: 01:84 F8:DB:88:3E: 02:72 F8:DB:88:3E: 01:EC Not Installed Display extra MACs for chassis. racadm getmacaddress -c all LOMs or mezzanine cards. • Displays the user-defined MAC and WWN address. - racadm getmacaddress -c io-...
... getmacaddress -m server-1 -x 42 racadm getmacaddress -c flexaddress • Displays the MAC/WWN addresses for all • Displays the chassis assigned WWN/MAC address. racadm getmacaddress -m chassis CMC Present N/A 74:86:7A:D5:33: N/A 44 Displays the MAC address for switch -1 racadm getmacaddress -m switch-1 Switch...:DB:88:3E: 01:84 F8:DB:88:3E: 02:72 F8:DB:88:3E: 01:EC Not Installed Display extra MACs for chassis. racadm getmacaddress -c all LOMs or mezzanine cards. • Displays the user-defined MAC and WWN address. - racadm getmacaddress -c io-...