Hardware Owner's Manual
Page 3
Contents 1 About Your System 11 Accessing System Features During Startup 11 Front-Panel Features and Indicators 12 Hard-Drive Indicator Patterns 15 Back-Panel Features and Indicators 16 NIC Indicator Codes 18 Power and System Board Indicator Codes 20 Power Supply Indicator Codes 21 BMC Heart Beat LED 22 POST Error Codes 23 Collecting System Event Log for Investigation . . . 23 Other Information You May Need 33 2 Using the System Setup Program 35 Start Menu 35 System Setup Options at Boot 36 Console Redirection 36 Main Menu 37 Main Screen 37 Contents 3
Contents 1 About Your System 11 Accessing System Features During Startup 11 Front-Panel Features and Indicators 12 Hard-Drive Indicator Patterns 15 Back-Panel Features and Indicators 16 NIC Indicator Codes 18 Power and System Board Indicator Codes 20 Power Supply Indicator Codes 21 BMC Heart Beat LED 22 POST Error Codes 23 Collecting System Event Log for Investigation . . . 23 Other Information You May Need 33 2 Using the System Setup Program 35 Start Menu 35 System Setup Options at Boot 36 Console Redirection 36 Main Menu 37 Main Screen 37 Contents 3
Hardware Owner's Manual
Page 20
... System identification indicator Indicator Steady Green Blinks Amber Blinks Green/Amber Steady Blue Blinks Blue Off Condition Power On S0/S1 BMC Critical condition event in Power Off mode S4/S5 BMC Critical condition event in Power On mode S0/S1 IPMI Via Chassis Identify Command On or ID Button Press ID...
... System identification indicator Indicator Steady Green Blinks Amber Blinks Green/Amber Steady Blue Blinks Blue Off Condition Power On S0/S1 BMC Critical condition event in Power Off mode S4/S5 BMC Critical condition event in Power On mode S0/S1 IPMI Via Chassis Identify Command On or ID Button Press ID...
Hardware Owner's Manual
Page 22
Figure 1-15. BMC Heart Beat LED 1 2 1 BMC heart beat LED 2 system board 22 About Your System When BMC firmware is ready, the BMC heart beat LED blinks. BMC Heart Beat LED The system board provides BMC heart beat LED (CR24) for BMC debugs.
Figure 1-15. BMC Heart Beat LED 1 2 1 BMC heart beat LED 2 system board 22 About Your System When BMC firmware is ready, the BMC heart beat LED blinks. BMC Heart Beat LED The system board provides BMC heart beat LED (CR24) for BMC debugs.
Hardware Owner's Manual
Page 23
... power to the system for 10 seconds and restart the system. POST Error Codes Collecting System Event Log for Investigation Error Messages are logged in BMC Cause Corrective Actions 0000h Yes Timer Count Read/Write Error Remove AC power to the system for 10 seconds and restart the system. If the... problem persists, see "Getting Help" on page 143. 000Bh Yes CMOS Memory Size Error Remove AC power to the IP address of the BMC. If the problem persists, see "Getting Help" on page 143. You can be accessed through system BIOS and the...
... power to the system for 10 seconds and restart the system. POST Error Codes Collecting System Event Log for Investigation Error Messages are logged in BMC Cause Corrective Actions 0000h Yes Timer Count Read/Write Error Remove AC power to the system for 10 seconds and restart the system. If the... problem persists, see "Getting Help" on page 143. 000Bh Yes CMOS Memory Size Error Remove AC power to the IP address of the BMC. If the problem persists, see "Getting Help" on page 143. You can be accessed through system BIOS and the...
Hardware Owner's Manual
Page 24
... the problem persists, see "Getting Help" on page 143. 0046h Yes DMAC2 Channel Register Error See "Troubleshooting System Memory" on page 121. Code Log in BMC Cause Corrective Actions 000Ch Yes RAM Read/Write Test Error Remove AC power to the system for 10 seconds and restart the system.
... the problem persists, see "Getting Help" on page 143. 0046h Yes DMAC2 Channel Register Error See "Troubleshooting System Memory" on page 121. Code Log in BMC Cause Corrective Actions 000Ch Yes RAM Read/Write Test Error Remove AC power to the system for 10 seconds and restart the system.
Hardware Owner's Manual
Page 25
... Yes Language Module Error See "Getting Help" on page 143. 005Dh Yes ATA SMART Feature Error See "Getting Help" on page 123. Code Log in BMC Cause Corrective Actions 0047h Yes PMM Memory Allocation Error See "Troubleshooting System Memory" on page 139. See "Jumper Settings" on page 121. See "Jumper Settings...
... Yes Language Module Error See "Getting Help" on page 143. 005Dh Yes ATA SMART Feature Error See "Getting Help" on page 123. Code Log in BMC Cause Corrective Actions 0047h Yes PMM Memory Allocation Error See "Troubleshooting System Memory" on page 139. See "Jumper Settings" on page 121. See "Jumper Settings...
Hardware Owner's Manual
Page 26
... the problem persists, see "Getting Help" on page 143. Remove AC power to the system for 10 seconds and restart the system. Code Log in BMC Cause 0066h Yes HDD 6 Error 0067h Yes HDD 7 Error 0080h Yes 0081h Yes ATAPI 0 Error ATAPI 1 Error 0082h Yes ATAPI 2 Error 0083h Yes ATAPI 3 Error...
... the problem persists, see "Getting Help" on page 143. Remove AC power to the system for 10 seconds and restart the system. Code Log in BMC Cause 0066h Yes HDD 6 Error 0067h Yes HDD 7 Error 0080h Yes 0081h Yes ATAPI 0 Error ATAPI 1 Error 0082h Yes ATAPI 2 Error 0083h Yes ATAPI 3 Error...
Hardware Owner's Manual
Page 27
... Problems" on page 120. Ensure that the processor heat sinks are properly installed. Ensure that the processor heat sinks are properly installed. Code Log in BMC Cause 0086h Yes ATAPI 6 Error 0087h Yes ATAPI 7 Error 0120h Yes CPU1 Thermal Failure due to PROCHOT# 0121h Yes CPU2 Thermal Failure due to PROCHOT...
... Problems" on page 120. Ensure that the processor heat sinks are properly installed. Ensure that the processor heat sinks are properly installed. Code Log in BMC Cause 0086h Yes ATAPI 6 Error 0087h Yes ATAPI 7 Error 0120h Yes CPU1 Thermal Failure due to PROCHOT# 0121h Yes CPU2 Thermal Failure due to PROCHOT...
Hardware Owner's Manual
Page 28
Code Log in BMC Cause 0123h Yes CPU4 Thermal Failure due to the system for 10 seconds and restart the system. Remove AC power to the system for 10 ...
Code Log in BMC Cause 0123h Yes CPU4 Thermal Failure due to the system for 10 seconds and restart the system. Remove AC power to the system for 10 ...
Hardware Owner's Manual
Page 29
... persists, see "Getting Help" on page 143. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in BMC Cause 0162h Yes CPU3 Processor missing microcode 0163h Yes CPU4 Processor missing microcode 0180 Yes CPU 1 stepping no support 0181 Yes CPU 2 stepping no support...
... persists, see "Getting Help" on page 143. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in BMC Cause 0162h Yes CPU3 Processor missing microcode 0163h Yes CPU4 Processor missing microcode 0180 Yes CPU 1 stepping no support 0181 Yes CPU 2 stepping no support...
Hardware Owner's Manual
Page 30
... for 10 seconds and restart the system. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in BMC Cause 0192h Yes L2 cache size mismatch 0193h Yes CPUID, Processor stepping are different 0194h Yes CPUID, Processor stepping are different 0195h Yes Front side...
... for 10 seconds and restart the system. Ensure that your processors match and conform to the type described in the processor technical specifications outlined in BMC Cause 0192h Yes L2 cache size mismatch 0193h Yes CPUID, Processor stepping are different 0194h Yes CPUID, Processor stepping are different 0195h Yes Front side...
Hardware Owner's Manual
Page 31
... 43. If the problem persists, see "USB Configuration" on page 114. See "Troubleshooting a USB Device" on page 114. About Your System 31 Code Log in BMC Cause Corrective Actions 0197h Yes Processor speeds mismatched Ensure that your processors match and conform to the type described in the processor technical specifications outlined...
... 43. If the problem persists, see "USB Configuration" on page 114. See "Troubleshooting a USB Device" on page 114. About Your System 31 Code Log in BMC Cause Corrective Actions 0197h Yes Processor speeds mismatched Ensure that your processors match and conform to the type described in the processor technical specifications outlined...
Hardware Owner's Manual
Page 32
...to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 121. F003h No BIOS Update BMC FRU failed Remove AC power to the system for details on page 143. 32 About Your System If the problem persists, see "Getting Help" on... Full Check the SEL for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 121. Code Log in BMC Cause Corrective Actions 8301h No SMBIOS Not Enough Space In See "Troubleshooting F000 System Memory" on page 143. If the problem persists, see "Getting ...
...to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 121. F003h No BIOS Update BMC FRU failed Remove AC power to the system for details on page 143. 32 About Your System If the problem persists, see "Getting Help" on... Full Check the SEL for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 121. Code Log in BMC Cause Corrective Actions 8301h No SMBIOS Not Enough Space In See "Troubleshooting F000 System Memory" on page 143. If the problem persists, see "Getting ...
Hardware Owner's Manual
Page 33
... be included within this document or as a separate document. If the problem persists, see "Getting Help" on support.dell.com/manuals and read the updates first because they often supersede information in BMC Cause Corrective Actions F005h No BIOS Update FRU Internal Area Remove AC power to the system for 10 seconds...
... be included within this document or as a separate document. If the problem persists, see "Getting Help" on support.dell.com/manuals and read the updates first because they often supersede information in BMC Cause Corrective Actions F005h No BIOS Update FRU Internal Area Remove AC power to the system for 10 seconds...
Hardware Owner's Manual
Page 47
... Windows Hardware Error Architecture. Delay Time: Sets AC power recovery delay time between minimum and maximum. The selection of system power on after BMC initiates:. (Immediate default) • Immediate: powers on directly after BMC initiates. • Random: randomly selects time to Power-on or Last State takes 60 seconds for running... BMC initialization after AC Power on . • User define: user selects the time. - Wake on RING function Enables or disables Wake on AC Power Loss ...
... Windows Hardware Error Architecture. Delay Time: Sets AC power recovery delay time between minimum and maximum. The selection of system power on after BMC initiates:. (Immediate default) • Immediate: powers on directly after BMC initiates. • Random: randomly selects time to Power-on or Last State takes 60 seconds for running... BMC initialization after AC Power on . • User define: user selects the time. - Wake on RING function Enables or disables Wake on AC Power Loss ...
Hardware Owner's Manual
Page 48
... version. This item disappears when Remote Access is enabled. Displays NIC2 MAC Address. Displays chassis part number. Displays BMC device ID. Displays BMC firmware version. Make sure the selected port is disabled. Displays chassis serial numbers. Flow Control (None default) Selects...1 MAC Address NIC 2 MAC Address System Part Number System Serial Number Chassis Part Number Chassis Serial Numbers BIOS Version BMC Device ID BMC Firmware Revision FCB Firmware Revision Description Displays server board part number. Displays NIC1 MAC Address. Displays system serial number. Displays...
... version. This item disappears when Remote Access is enabled. Displays NIC2 MAC Address. Displays chassis part number. Displays BMC device ID. Displays BMC firmware version. Make sure the selected port is disabled. Displays chassis serial numbers. Flow Control (None default) Selects...1 MAC Address NIC 2 MAC Address System Part Number System Serial Number Chassis Part Number Chassis Serial Numbers BIOS Version BMC Device ID BMC Firmware Revision FCB Firmware Revision Description Displays server board part number. Displays NIC1 MAC Address. Displays system serial number. Displays...
Hardware Owner's Manual
Page 49
... NOTE: When Flow Control is discontinued by pressing . This item disappears when Remote Access is disabled. IPMI Configuration Option Status Of BMC BMC Firmware Revision View BMC System Event Log Description Displays BMC status. Selecting this option and pressing Enter, displays: Total Number Of Entries, SEL Entry Number, SEL Record ID, SEL Record Type... Hyper Terminal on remote side is set to Always) Terminal Type (VT100 default) Selects the target terminal type. But the is discontinued when pressing . Displays BMC Firmware Revision.
... NOTE: When Flow Control is discontinued by pressing . This item disappears when Remote Access is disabled. IPMI Configuration Option Status Of BMC BMC Firmware Revision View BMC System Event Log Description Displays BMC status. Selecting this option and pressing Enter, displays: Total Number Of Entries, SEL Entry Number, SEL Record ID, SEL Record Type... Hyper Terminal on remote side is set to Always) Terminal Type (VT100 default) Selects the target terminal type. But the is discontinued when pressing . Displays BMC Firmware Revision.
Hardware Owner's Manual
Page 50
...NOTE: The default values are dependant on BMC setting IP Address Option IP Address (default value depends on BMC setting) Description Enters IP address in decimal in decimal only). BMC PEF status Displays BMC PEF status. LAN Configuration Option Channel Number (01 default) BMC IP address source (DHCP default) Description ...Enters channel number for SET LAN Config Command. Set BMC NIC (Shared default) Sets the type of XXX.XXX.XXX.XXX (XXX is below 16. NOTE: When BMC IP status is static, IP Address is reset. Proper value is less than 256...
...NOTE: The default values are dependant on BMC setting IP Address Option IP Address (default value depends on BMC setting) Description Enters IP address in decimal in decimal only). BMC PEF status Displays BMC PEF status. LAN Configuration Option Channel Number (01 default) BMC IP address source (DHCP default) Description ...Enters channel number for SET LAN Config Command. Set BMC NIC (Shared default) Sets the type of XXX.XXX.XXX.XXX (XXX is below 16. NOTE: When BMC IP status is static, IP Address is reset. Proper value is less than 256...
Hardware Owner's Manual
Page 51
..., Select [OK] to discard changes and exit, or press N to return to the setup main menu. Subnet Mask Option Subnet Mask (default value depends on BMC setting) Exit Menu Description Enters default Gateway IP in decimal in the form of XXX.XXX.XXX.XXX (XXX is less than 256 and in... you have made without leaving the setup utility Using the System Setup Program 51 Default Gateway IP Option Default Gateway IP (default value depends on BMC setting) Description Enters subnet mask in decimal in the form of XXX.XXX.XXX.XXX (XXX is useful. Select this item and press Enter to...
..., Select [OK] to discard changes and exit, or press N to return to the setup main menu. Subnet Mask Option Subnet Mask (default value depends on BMC setting) Exit Menu Description Enters default Gateway IP in decimal in the form of XXX.XXX.XXX.XXX (XXX is less than 256 and in... you have made without leaving the setup utility Using the System Setup Program 51 Default Gateway IP Option Default Gateway IP (default value depends on BMC setting) Description Enters subnet mask in decimal in the form of XXX.XXX.XXX.XXX (XXX is useful. Select this item and press Enter to...
Hardware Owner's Manual
Page 130
17 expansion slot 19 power button 21 serial port 23 NIC2 connector (RJ45) 25 ID LED 18 BMC debug connector 20 VGA port 22 KVM over IP port 24 NIC1 connector (RJ45) 26 USB port Backplane Connectors 3.5" drives Figure 5-2. Front View of the ...
17 expansion slot 19 power button 21 serial port 23 NIC2 connector (RJ45) 25 ID LED 18 BMC debug connector 20 VGA port 22 KVM over IP port 24 NIC1 connector (RJ45) 26 USB port Backplane Connectors 3.5" drives Figure 5-2. Front View of the ...