Command Line Interface Guide
Page 414
...: RS1 System location: System MAC Address: 00:00:b0:00:00:00 Sys Object ID: 1.3.6.1.4.1.674.10895.3020 PowerConnect 5400 Type: Main Power Supply ok Status Redundant Power ok Supply Status: Fan 1 Status: OK Fan 2 Status: OK console> set system The set system {iscsi | dva} • iscsi - The device supports iscsi and ACL...
...: RS1 System location: System MAC Address: 00:00:b0:00:00:00 Sys Object ID: 1.3.6.1.4.1.674.10895.3020 PowerConnect 5400 Type: Main Power Supply ok Status Redundant Power ok Supply Status: Fan 1 Status: OK Fan 2 Status: OK console> set system The set system {iscsi | dva} • iscsi - The device supports iscsi and ACL...
User's Guide
Page 27
... 2-4. The port is operating in the SFP port, the SFP port is active, unless the copper connector of the Base-T port of links, power supplies, fans, and system diagnostics. Physical Dimensions The device has the following table: Table 2-1. Speed/link/activity is indicated on the right LED. If both RJ-45...
... 2-4. The port is operating in the SFP port, the SFP port is active, unless the copper connector of the Base-T port of links, power supplies, fans, and system diagnostics. Physical Dimensions The device has the following table: Table 2-1. Speed/link/activity is indicated on the right LED. If both RJ-45...
User's Guide
Page 28
... system LEDs. When the SFP port is connected, the Duplex LED on the left side of the front panel, provide information about the power supplies, fans, thermal conditions, and diagnostics. System LEDs The system LEDs, located on the corresponding copper Combo port is currently down. System LEDs 28 Hardware Description SFP...
... system LEDs. When the SFP port is connected, the Duplex LED on the left side of the front panel, provide information about the power supplies, fans, thermal conditions, and diagnostics. System LEDs The system LEDs, located on the corresponding copper Combo port is currently down. System LEDs 28 Hardware Description SFP...
User's Guide
Page 29
... sharing. The main power supply is too high. The system temperature is not currently operating. Table 2-3. System LED Indications LED Diagnostics (DIAG) Fan (FAN) Redundant Power Supply (RPS) Main Power Supply (PWR) Temperature (TEMP) Color Green Flashing Green Static Red Static Green Static Red Static Green ...RPS unit. The redundant power supply is normal. One or more information on LEDs, see "LED Definitions" on page 27. For more fans are not operating. Hardware Components Power Supplies The device has an internal power supply unit (AC unit) and a connector to connect the ...
... sharing. The main power supply is too high. The system temperature is not currently operating. Table 2-3. System LED Indications LED Diagnostics (DIAG) Fan (FAN) Redundant Power Supply (RPS) Main Power Supply (PWR) Temperature (TEMP) Color Green Flashing Green Static Red Static Green Static Red Static Green ...RPS unit. The redundant power supply is normal. One or more information on LEDs, see "LED Definitions" on page 27. For more fans are not operating. Hardware Components Power Supplies The device has an internal power supply unit (AC unit) and a connector to connect the ...
User's Guide
Page 30
... status can be verified by observing the LEDs that indicate if there is possible with power supplied from this unit only. Operation is a faulty fan. DC Power Supply Unit An external DC power supply unit is used as a redundant power supply unit. No configuration is required. RPS600 connector type ...the front panel and indicates whether the AC unit is connected to 5V DC at 5A, 12V DC at 3A. Ventilation System The device uses a fan system for cooling. The unit automatically senses the available voltage rating (110 or 220V) and no setting is required. AC Power Supply Unit The ...
... status can be verified by observing the LEDs that indicate if there is possible with power supplied from this unit only. Operation is a faulty fan. DC Power Supply Unit An external DC power supply unit is used as a redundant power supply unit. No configuration is required. RPS600 connector type ...the front panel and indicates whether the AC unit is connected to 5V DC at 5A, 12V DC at 3A. Ventilation System The device uses a fan system for cooling. The unit automatically senses the available voltage rating (110 or 220V) and no setting is required. AC Power Supply Unit The ...
User's Guide
Page 70
The following is an example of the CLI commands: Console (config)# hostname dell Console (config)# snmp-server contact Dell_Tech_Supp Console (config)# snmp-server location New_York Console... set 13:32:00 7 Dec 2004 Console> show clock 13:32:00 (UTC+0) Dec 7 2004 No time source DELL Switch# show system System Description: System Up Time (days,hour:min:sec): System Contact: System Name: System Location: ...f4:00:01 1.3.6.1.4.1.674.10895.3000 Type: Main Power Supply Status ok PowerConnect 5400 Redundant Power Supply Status: ok FAN 1 Status: OK FAN 2 Status: OK 70 Configuring System Information
The following is an example of the CLI commands: Console (config)# hostname dell Console (config)# snmp-server contact Dell_Tech_Supp Console (config)# snmp-server location New_York Console... set 13:32:00 7 Dec 2004 Console> show clock 13:32:00 (UTC+0) Dec 7 2004 No time source DELL Switch# show system System Description: System Up Time (days,hour:min:sec): System Contact: System Name: System Location: ...f4:00:01 1.3.6.1.4.1.674.10895.3000 Type: Main Power Supply Status ok PowerConnect 5400 Redundant Power Supply Status: ok FAN 1 Status: OK FAN 2 Status: OK 70 Configuring System Information
User's Guide
Page 77
...Description Displays system information. Figure 6-4. Not Present - The possible field values are not operating normally for the specified unit. • Fan - Configuring System Information 77 To open the System Health page, click System→ General→ Health in the System Health page...System Health • Power Supply Status - The main power supply is not present for the specified unit. - The device fan status. Viewing System Health Information The System Health page shows physical device hardware information. Not Present - Viewing System Health Information Using...
...Description Displays system information. Figure 6-4. Not Present - The possible field values are not operating normally for the specified unit. • Fan - Configuring System Information 77 To open the System Health page, click System→ General→ Health in the System Health page...System Health • Power Supply Status - The main power supply is not present for the specified unit. - The device fan status. Viewing System Health Information The System Health page shows physical device hardware information. Not Present - Viewing System Health Information Using...
User's Guide
Page 78
DELL Switch# show system System Description: System Up Time (days,hour:min:sec): System Contact: System Name: System Location: System MAC Address: Sys Object ID: Type: PowerConnect 5400 Power Supply Main Redundant Status -------OK OK FAN 1 2 Status -------OK OK DELL Switch# Ethernet Routing Switch 0,00:04:17 spk DELL Switch R&D 00:10:b5:f4:00:01 1.3.6.1.4.1.674.10895.3000 78 Configuring System Information
DELL Switch# show system System Description: System Up Time (days,hour:min:sec): System Contact: System Name: System Location: System MAC Address: Sys Object ID: Type: PowerConnect 5400 Power Supply Main Redundant Status -------OK OK FAN 1 2 Status -------OK OK DELL Switch# Ethernet Routing Switch 0,00:04:17 spk DELL Switch R&D 00:10:b5:f4:00:01 1.3.6.1.4.1.674.10895.3000 78 Configuring System Information
User's Guide
Page 428
Table 10-4. Physical Device Specifications Feature Unit Size Ventilation Specification • 19" Width • 1U Height Two fans per unit. Table 10-3. Device Memory Specifications Memory Type CPU DRAM Flash Memory Packet Buffer Memory Amount 64MB 16MB 2Mb 428 Device Specifications Operating Conditions ...
Table 10-4. Physical Device Specifications Feature Unit Size Ventilation Specification • 19" Width • 1U Height Two fans per unit. Table 10-3. Device Memory Specifications Memory Type CPU DRAM Flash Memory Packet Buffer Memory Amount 64MB 16MB 2Mb 428 Device Specifications Operating Conditions ...