... OR SWITCH...12 10BASE-T Device...13 100BASE-TX Device...13 SWITCH MANAGEMENT CONCEPTS ...14 LOCAL CONSOLE MANAGEMENT ...14 Diagnostic (console) port (RS-232 DCE) ...14 IP ADDRESSES AND SNMP COMMUNITY NAMES...15 TRAPS...15 MIBS...16 PACKET FORWARDING...16 Aging Time ...16 Filtering Database...17 SPANNING TREE ALGORITHM ...17 STA Operation Levels...
... OR SWITCH...12 10BASE-T Device...13 100BASE-TX Device...13 SWITCH MANAGEMENT CONCEPTS ...14 LOCAL CONSOLE MANAGEMENT ...14 Diagnostic (console) port (RS-232 DCE) ...14 IP ADDRESSES AND SNMP COMMUNITY NAMES...15 TRAPS...15 MIBS...16 PACKET FORWARDING...16 Aging Time ...16 Filtering Database...17 SPANNING TREE ALGORITHM ...17 STA Operation Levels...
Product Manual
Page 3
... BY REGISTERED USERS...31 Create/Modify User Accounts ...31 View/Delete User Accounts ...33 SETTING UP THE SWITCH...34 Configuration...34 Configure IP Address ...34 Configure Console ...36 Configure Switch ...37 Configure Ports ...38 Configure Slot1 Module ...40 Configure Slot2 Module ...42 Configure Port ...Save Switch History to TFTP Server...80 SNMP Manager Configuration ...81 SWITCH MONITORING...82 Network Monitoring ...82 Traffic Statistics ...83 Browse Address Table ...89 Browse IGMP Status ...90 Browse GVRP Status ...91 Browse GMRP Status...91 Switch History ...92 RESETTING THE SWITCH...93...
... BY REGISTERED USERS...31 Create/Modify User Accounts ...31 View/Delete User Accounts ...33 SETTING UP THE SWITCH...34 Configuration...34 Configure IP Address ...34 Configure Console ...36 Configure Switch ...37 Configure Ports ...38 Configure Slot1 Module ...40 Configure Slot2 Module ...42 Configure Port ...Save Switch History to TFTP Server...80 SNMP Manager Configuration ...81 SWITCH MONITORING...82 Network Monitoring ...82 Traffic Statistics ...83 Browse Address Table ...89 Browse IGMP Status ...90 Browse GVRP Status ...91 Browse GMRP Status...91 Switch History ...92 RESETTING THE SWITCH...93...
Product Manual
Page 20
... of its configured ports transitions from the Learning state to the Forwarding state, or from the Switch by a bridge soon after its own IP Address, which network managers may receive traps from the Forwarding state to reach the network manager, and vice versa. This implies that software settings... are reconfigured and hardware systems are given certain rights and access in the Switch and set an IP Address for management packets to go through a router to the Blocking state. You can also specify which is used for communication with an SNMP...
... of its configured ports transitions from the Learning state to the Forwarding state, or from the Switch by a bridge soon after its own IP Address, which network managers may receive traps from the Forwarding state to reach the network manager, and vice versa. This implies that software settings... are reconfigured and hardware systems are given certain rights and access in the Switch and set an IP Address for management packets to go through a router to the Blocking state. You can also specify which is used for communication with an SNMP...
Product Manual
Page 21
... is a parameter that you use a third-party vendors' SNMP software to forward packets. Examples of read -only constants are the Switch's IP Address, Spanning Tree Algorithm parameters, and port status. If your software provides functions to browse or modify MIBs, you must know the MIB OIDs... software. Read-only MIBs variables can be retrieved by specifying the MIB's Object-Identity (OID) at either constants that are transmitted to link up. ♦ Port Partition This trap is sent whenever a port is partitioned as an extended Management Information Base. Packet Forwarding The ...
... is a parameter that you use a third-party vendors' SNMP software to forward packets. Examples of read -only constants are the Switch's IP Address, Spanning Tree Algorithm parameters, and port status. If your software provides functions to browse or modify MIBs, you must know the MIB OIDs... software. Read-only MIBs variables can be retrieved by specifying the MIB's Object-Identity (OID) at either constants that are transmitted to link up. ♦ Port Partition This trap is sent whenever a port is partitioned as an extended Management Information Base. Packet Forwarding The ...
Product Manual
Page 33
... the same as "s." You can allow you will execute that you use the tab key and backspace key for your Switch, you have set an IP address for moving around console. 4. Please note that can also use of the cursor. 3. Use Save Changes from a Telnet interface. An asterisk "*" indicates a change has been...
... the same as "s." You can allow you will execute that you use the tab key and backspace key for your Switch, you have set an IP address for moving around console. 4. Please note that can also use of the cursor. 3. Use Save Changes from a Telnet interface. An asterisk "*" indicates a change has been...
Product Manual
Page 39
...following menu appears: Figure 6-8. See the next chapter for out-of-band communication. Choose Configure IP Address to access the first item on the network. Configure IP Address The Switch needs to have an IP address assigned to it so that an In-Band network management system or Telnet client can find ... by describing the Configuration, Update Firmware and Configuration Files, Save Changes, and System Utilities menus and their respective sub-menus. The IP Configuration screen allows you to be able to manage the Switch from an SNMP-based Network Management System such as SNMP v1 or ...
...following menu appears: Figure 6-8. See the next chapter for out-of-band communication. Choose Configure IP Address to access the first item on the network. Configure IP Address The Switch needs to have an IP address assigned to it so that an In-Band network management system or Telnet client can find ... by describing the Configuration, Update Firmware and Configuration Files, Save Changes, and System Utilities menus and their respective sub-menus. The IP Configuration screen allows you to be able to manage the Switch from an SNMP-based Network Management System such as SNMP v1 or ...
Product Manual
Page 40
... (represented in this field unchanged. These fields should be sent when the Switch is powered up . ♦ IP Address Determines the IP address used after the Switch has been Reset. This address should get its IP Address settings from the user (Manual), a BOOTP server, or a DHCP server. If Manual is shared by the... be 255.0.0.0 for a Class A network, 255.255.0.0 for a Class B network, and 255.255.255.0 for a Class C network. ♦ Default Gateway IP address that can be accessible outside the current subnet should be of the form xxx.xxx.xxx.xxx, where each xxx is usually the...
... (represented in this field unchanged. These fields should be sent when the Switch is powered up . ♦ IP Address Determines the IP address used after the Switch has been Reset. This address should get its IP Address settings from the user (Manual), a BOOTP server, or a DHCP server. If Manual is shared by the... be 255.0.0.0 for a Class A network, 255.255.0.0 for a Class B network, and 255.255.255.0 for a Class C network. ♦ Default Gateway IP address that can be accessible outside the current subnet should be of the form xxx.xxx.xxx.xxx, where each xxx is usually the...
Product Manual
Page 82
.... Update Firmware and Configuration Files screen After making your TFTP server to be used only if the Firmware Update is set are: ♦ TFTP Server Address The IP address of the runtime image file on the TFTP server for a runtime image file on the TFTP server. ♦ File Name The complete path and...
.... Update Firmware and Configuration Files screen After making your TFTP server to be used only if the Firmware Update is set are: ♦ TFTP Server Address The IP address of the runtime image file on the TFTP server for a runtime image file on the TFTP server. ♦ File Name The complete path and...
Product Manual
Page 84
The fields you can set are: ♦ Destination IP Address The IP address of the device to be Pinged. ♦ Repetitions Amount of the Ping Test screen, you can view the Ping status, including Result, Reply, Time out, ...
The fields you can set are: ♦ Destination IP Address The IP address of the device to be Pinged. ♦ Repetitions Amount of the Ping Test screen, you can view the Ping status, including Result, Reply, Time out, ...
Product Manual
Page 85
... Utilities on the main menu) to begin the saving procedure. Save Settings to TFTP Server screen The fields you can set are: ♦ Server IP Address The IP address of the screen. The result will be displayed in the lower part of the TFTP server where you wish to save the settings for the...
... Utilities on the main menu) to begin the saving procedure. Save Settings to TFTP Server screen The fields you can set are: ♦ Server IP Address The IP address of the screen. The result will be displayed in the lower part of the TFTP server where you wish to save the settings for the...
Product Manual
Page 86
... SNMP traps to four different network management hosts. If the Switch receives a request with the community name settings you can set are: ♦ Server IP Address The IP address of characters used for the file. The Switch allows traps to be located. ♦ File Name The complete path and filename on or when a system...
... SNMP traps to four different network management hosts. If the Switch receives a request with the community name settings you can set are: ♦ Server IP Address The IP address of characters used for the file. The Switch allows traps to be located. ♦ File Name The complete path and filename on or when a system...
Product Manual
Page 87
An entry can be included on the Switch. Network Monitoring The Network Monitoring menu offers six items, Traffic Statistics, Browse Address Table, Browse IGMP Status, Browse GVRP Status, Browse GMRP Status, and Switch History. 82 Using the Console Interface Switch Monitoring The...set: ♦ SNMP Community String The community string that the community member can be disabled by changing its status to Invalid. ♦ IP Address The IP address of network traffic. Any station not privy to this community name entry is Valid or Invalid. 24-port NWay Ethernet Switch User's Guide ...
An entry can be included on the Switch. Network Monitoring The Network Monitoring menu offers six items, Traffic Statistics, Browse Address Table, Browse IGMP Status, Browse GVRP Status, Browse GMRP Status, and Switch History. 82 Using the Console Interface Switch Monitoring The...set: ♦ SNMP Community String The community string that the community member can be disabled by changing its status to Invalid. ♦ IP Address The IP address of network traffic. Any station not privy to this community name entry is Valid or Invalid. 24-port NWay Ethernet Switch User's Guide ...
Product Manual
Page 95
... Group Management Protocol (IGMP). The fields displayed are defined as follows: ♦ IGMP Snooping Indicates whether IGMP snooping is a read-only Browse Address Table that contains Port, MAC Address, Learned status, and the VLAN number of the multicast group being displayed. 90 Using the Console Interface Browse IGMP Status The Browse IGMP... Status function allows you to recognize IGMP queries and reports sent between IGMP queries. ♦ VLAN The selected VLAN. ♦ Multicast Group The Multicast IP address of the Multicast group being displayed. ♦ MAC...
... Group Management Protocol (IGMP). The fields displayed are defined as follows: ♦ IGMP Snooping Indicates whether IGMP snooping is a read-only Browse Address Table that contains Port, MAC Address, Learned status, and the VLAN number of the multicast group being displayed. 90 Using the Console Interface Browse IGMP Status The Browse IGMP... Status function allows you to recognize IGMP queries and reports sent between IGMP queries. ♦ VLAN The selected VLAN. ♦ Multicast Group The Multicast IP address of the Multicast group being displayed. ♦ MAC...
Product Manual
Page 99
... enabled/disabled settings of ports, security settings, etc.) will be absolutely certain that this is done, all of the Switch's settings stored in the Configure IP Address menu. 24-port NWay Ethernet Switch User's Guide Figure 6-65. Restart System screen Factory Reset Before performing a factory reset, be erased and restored to do...
... enabled/disabled settings of ports, security settings, etc.) will be absolutely certain that this is done, all of the Switch's settings stored in the Configure IP Address menu. 24-port NWay Ethernet Switch User's Guide Figure 6-65. Restart System screen Factory Reset Before performing a factory reset, be erased and restored to do...
Product Manual
Page 101
...to access the same internal switching software and configure it to the IP address you have defined for your Switch is to Load Panel: 96 Web-Based Network Management In the page that opens, click on the Login to DES-3225G Web-based Management button: This opens the main page in the ...console program. A Web browser is a program which allows a person to read something like: http://123.123.123.123, where the numbers 123 represent the IP address of the Switch. This should read ...
...to access the same internal switching software and configure it to the IP address you have defined for your Switch is to Load Panel: 96 Web-Based Network Management In the page that opens, click on the Login to DES-3225G Web-based Management button: This opens the main page in the ...console program. A Web browser is a program which allows a person to read something like: http://123.123.123.123, where the numbers 123 represent the IP address of the Switch. This should read ...
Product Manual
Page 103
.... Once you do not need to configure any IP parameters because a BOOTP server automatically assigns IP configuration parameters to determine whether the Switch should get its IP Address settings: Manual, BOOTP, and DHCP. ♦ MAC Address The Ethernet address for the device. If you enable DHCP, a...request will be sent when the Switch is used to the Switch. The information is described as the physical address ♦ IP Address The host address for how the Switch receives its IP Address settings from the user (Manual), a BOOTP server, or a DHCP server. Also known as follows: ...
.... Once you do not need to configure any IP parameters because a BOOTP server automatically assigns IP configuration parameters to determine whether the Switch should get its IP Address settings: Manual, BOOTP, and DHCP. ♦ MAC Address The Ethernet address for the device. If you enable DHCP, a...request will be sent when the Switch is used to the Switch. The information is described as the physical address ♦ IP Address The host address for how the Switch receives its IP Address settings from the user (Manual), a BOOTP server, or a DHCP server. Also known as follows: ...
Product Manual
Page 129
... each section. Traps and Community Strings 24-port NWay Ethernet Switch User's Guide Figure 7-26. The Community Strings information is described as follows: ♦ IP Address The IP address of Read-Only or Read-Write using the SNMP community name. ♦ Status Option to set the trap receiving station to Valid or Invalid. Traps...
... each section. Traps and Community Strings 24-port NWay Ethernet Switch User's Guide Figure 7-26. The Community Strings information is described as follows: ♦ IP Address The IP address of Read-Only or Read-Write using the SNMP community name. ♦ Status Option to set the trap receiving station to Valid or Invalid. Traps...
Product Manual
Page 149
... Network or SLIP. Determines whether the new firmware code should be obtained through the Ethernet network or through the console port. ♦ TFTP Server Address The IP address of the file which holds the new firmware code on the TFTP server. 144 Web-Based Network Management Update Firmware window To update firmware, fill...
... Network or SLIP. Determines whether the new firmware code should be obtained through the Ethernet network or through the console port. ♦ TFTP Server Address The IP address of the file which holds the new firmware code on the TFTP server. 144 Web-Based Network Management Update Firmware window To update firmware, fill...
Product Manual
Page 150
...-Based Network Management 145 Determines whether the configuration file should be obtained through the Ethernet network or through the console port. ♦ TFTP Server Address is The IP address of the TFTP server where the configuration file is. ♦ File Download Determines whether or not the Switch should download its configuration file the...
...-Based Network Management 145 Determines whether the configuration file should be obtained through the Ethernet network or through the console port. ♦ TFTP Server Address is The IP address of the TFTP server where the configuration file is. ♦ File Download Determines whether or not the Switch should download its configuration file the...
Product Manual
Page 151
Save Settings to TFTP Server window To save settings to TFTP Server 24-port NWay Ethernet Switch User's Guide Figure 7-47. Save Settings to a file on the TFTP server. ♦ Last Upload Status Read-only field displays the most recent upload activity. 146 Web-Based Network Management The information is described as follows: ♦ TFTP Server Address is The IP address of the TFTP server where the setting file will be saved. ♦ File Name The path and file name for the settings file on your TFTP server, fill the fields in above and then click Upload now.
Save Settings to TFTP Server window To save settings to TFTP Server 24-port NWay Ethernet Switch User's Guide Figure 7-47. Save Settings to a file on the TFTP server. ♦ Last Upload Status Read-only field displays the most recent upload activity. 146 Web-Based Network Management The information is described as follows: ♦ TFTP Server Address is The IP address of the TFTP server where the setting file will be saved. ♦ File Name The path and file name for the settings file on your TFTP server, fill the fields in above and then click Upload now.