Compaq ProLiant 6400R Servers
Page 17
...cable assembly b) 10-position power cable assembly c) 12-position power cable assembly d) Hard drive power cable assembly e) Left cable fan assembly 1 f) Left cable fan assembly 2 g) Right cable fan assembly h) Rear cable fan assembly 26 Miscellaneous signal cable kit * 101953-001 a) PCI cable assembly b) Diskette drive cable assembly c) Miscellaneous signal cable ... parts map * 101977-002 OPTIONS 34 Power supply blank cover * 122641-001 * Not shown ** For earlier 500-MHz models of the ProLiant 6400R server with a single rear CPU fan, instead of the external rear system...
...cable assembly b) 10-position power cable assembly c) 12-position power cable assembly d) Hard drive power cable assembly e) Left cable fan assembly 1 f) Left cable fan assembly 2 g) Right cable fan assembly h) Rear cable fan assembly 26 Miscellaneous signal cable kit * 101953-001 a) PCI cable assembly b) Diskette drive cable assembly c) Miscellaneous signal cable ... parts map * 101977-002 OPTIONS 34 Power supply blank cover * 122641-001 * Not shown ** For earlier 500-MHz models of the ProLiant 6400R server with a single rear CPU fan, instead of the external rear system...
Compaq ProLiant 6400R Servers
Page 26
..." in Chapter 4. If the LED indicator is green, then the fan is working properly. CAUTION: Leave failed or failing fans connected to the system until they can be replaced. 1 2 43 56 Figure 2-5. Removal and Replacement Procedures 2-9 Hot-Plug Fans ProLiant 6400R servers ship with six, redundant hot-plug fans. Figure 2-5 and Table 2-1 show the hot-plug...
..." in Chapter 4. If the LED indicator is green, then the fan is working properly. CAUTION: Leave failed or failing fans connected to the system until they can be replaced. 1 2 43 56 Figure 2-5. Removal and Replacement Procedures 2-9 Hot-Plug Fans ProLiant 6400R servers ship with six, redundant hot-plug fans. Figure 2-5 and Table 2-1 show the hot-plug...
Compaq ProLiant 6400R Servers
Page 29
...LED indicator is green, the fan is amber, the fan has failed. From the back of the server, loosen the captive thumbscrew located at the top of the Ultra2 SCSI simplex board. 2 To remove an external rear hot-plug redundant CPU fan, 1. 2-12 Compaq ProLiant 6400R Maintenance and Service Guide External ...Rear Hot-Plug Redundant System Fan Assembly IMPORTANT: It is not necessary to turn off the server to replace the external ...
...LED indicator is green, the fan is amber, the fan has failed. From the back of the server, loosen the captive thumbscrew located at the top of the Ultra2 SCSI simplex board. 2 To remove an external rear hot-plug redundant CPU fan, 1. 2-12 Compaq ProLiant 6400R Maintenance and Service Guide External ...Rear Hot-Plug Redundant System Fan Assembly IMPORTANT: It is not necessary to turn off the server to replace the external ...
Compaq ProLiant 6400R Servers
Page 39
2-22 Compaq ProLiant 6400R Maintenance and Service Guide Diskette Drive Cable Figure 2-18. Folding and routing diagram of the diskette drive cable with the diskette drive signal extension cable External Fan Cable Figure 2-19. Folding and routing diagram of the external fan cable NOTE: The fan cable folding and routing diagram is identical for the external rear hot-plug redundant CPU fan or the external rear hot-plug redundant system fan assembly.
2-22 Compaq ProLiant 6400R Maintenance and Service Guide Diskette Drive Cable Figure 2-18. Folding and routing diagram of the diskette drive cable with the diskette drive signal extension cable External Fan Cable Figure 2-19. Folding and routing diagram of the external fan cable NOTE: The fan cable folding and routing diagram is identical for the external rear hot-plug redundant CPU fan or the external rear hot-plug redundant system fan assembly.
Compaq ProLiant 6400R Servers
Page 133
.... NOTE: The following figure and table show the external rear hot-plug redundant CPU fan. 4 Chapter Connectors, Switches, and LED Indicators This chapter provides connector, switch, and LED information for Compaq ProLiant 6400R servers. Connectors This section contains graphics and tables depicting connector locations on the rear panel, system board, peripheral board, power backplane board...
.... NOTE: The following figure and table show the external rear hot-plug redundant CPU fan. 4 Chapter Connectors, Switches, and LED Indicators This chapter provides connector, switch, and LED information for Compaq ProLiant 6400R servers. Connectors This section contains graphics and tables depicting connector locations on the rear panel, system board, peripheral board, power backplane board...
Compaq ProLiant 6400R Servers
Page 139
... maintenance configuration switchbank (SW1) is located on 123456 Figure 4-6. Location and default setting for ProLiant servers with a single rear CPU fan have this switch in the On position. The following figure shows the location and default switch settings for the ProLiant 6400R server maintenance configuration switchbank for the maintenance configuration switch (SW1) Table 4-6 Maintenance Configuration...
... maintenance configuration switchbank (SW1) is located on 123456 Figure 4-6. Location and default setting for ProLiant servers with a single rear CPU fan have this switch in the On position. The following figure shows the location and default switch settings for the ProLiant 6400R server maintenance configuration switchbank for the maintenance configuration switch (SW1) Table 4-6 Maintenance Configuration...
Compaq ProLiant 6400R Servers
Page 142
4-10 Compaq ProLiant 6400R Maintenance and Service Guide Hot-Plug Fan LED Indicators The following figure and table show the location of the hot-plug fans and LEDs, and give the hot-plug fan locations. 2 1 7 6 43 5 Figure 4-9. Hot-plug fan and LED locations Table 4-9 Hot-Plug Fan and LED Locations Item Description Primary I/O fan Secondary I/O fan Primary CPU fan Secondary CPU fan External hot-plug redundant system fan Fan status LED Primary and secondary external hot-plug redundant system fan
4-10 Compaq ProLiant 6400R Maintenance and Service Guide Hot-Plug Fan LED Indicators The following figure and table show the location of the hot-plug fans and LEDs, and give the hot-plug fan locations. 2 1 7 6 43 5 Figure 4-9. Hot-plug fan and LED locations Table 4-9 Hot-Plug Fan and LED Locations Item Description Primary I/O fan Secondary I/O fan Primary CPU fan Secondary CPU fan External hot-plug redundant system fan Fan status LED Primary and secondary external hot-plug redundant system fan
Compaq ProLiant 6400R Servers
Page 161
...configured 3-35 located in special video slot 3-35 reported POST error 3-35 restarted with a signature of zero 3-36 CPU Fan (Fan X) failure detected 3-11 CPU Fan controller not responding 3-11 Current SCSI bus cable configuration is not recommended 3-11 Current System ROM is corrupt 3-7, ... Battery Charge Low 3-19 Array Accelerator Battery Depleted 3-19 Array Accelerator Configuration Error 3-19 Array Accelerator Not Responding 3-19 6 Compaq ProLiant 6400R Maintenance and Service Guide Data in use by expand operation 3-34 Board not attached 3-35 Cache Accelerator Slot X Initialization Failed ...
...configured 3-35 located in special video slot 3-35 reported POST error 3-35 restarted with a signature of zero 3-36 CPU Fan (Fan X) failure detected 3-11 CPU Fan controller not responding 3-11 Current SCSI bus cable configuration is not recommended 3-11 Current System ROM is corrupt 3-7, ... Battery Charge Low 3-19 Array Accelerator Battery Depleted 3-19 Array Accelerator Configuration Error 3-19 Array Accelerator Not Responding 3-19 6 Compaq ProLiant 6400R Maintenance and Service Guide Data in use by expand operation 3-34 Board not attached 3-35 Cache Accelerator Slot X Initialization Failed ...
Compaq ProLiant 6400R Setup and Installation Guide
Page 16
...expansion boards without requiring, but still compatible with only two CPU fans running. PCI Hot Plug device drivers and operating system support, however, are six total I/O expansion slots. System Fans The Compaq ProLiant 6400R server includes hot-plug, redundant fans that provide high-level thermal protection throughout your entire system.... slot is for modem use only. The system prompts you to replace the failed fan and enables the hot-plug secondary or redundant CPU fan to enable the PCI Hot Plug. All fans run at the server without powering down the server. A next-generation PCI Hot...
...expansion boards without requiring, but still compatible with only two CPU fans running. PCI Hot Plug device drivers and operating system support, however, are six total I/O expansion slots. System Fans The Compaq ProLiant 6400R server includes hot-plug, redundant fans that provide high-level thermal protection throughout your entire system.... slot is for modem use only. The system prompts you to replace the failed fan and enables the hot-plug secondary or redundant CPU fan to enable the PCI Hot Plug. All fans run at the server without powering down the server. A next-generation PCI Hot...
Compaq ProLiant 6400R Setup and Installation Guide
Page 83
Hot-plug fan LED indicators Table 3-11 Hot-Plug Fan LEDs Fan Description I/O fan LED I/O fan LED Primary CPU fan and secondary CPU fan LED Primary or secondary external system fan LED Primary and secondary external system fan LED LED Indication No light Green light Amber light Table 3-12 Hot-Plug Fan LED Status Status Power is not applied to the fan Power is applied to the fan, and the fan is functional Fan has failed 3-30 Compaq ProLiant 6400R Setup and Installation Guide 2. Verify the status of the fans by noting the LEDs at the fan location. 2 1 5 4 3 Figure 3-26.
Hot-plug fan LED indicators Table 3-11 Hot-Plug Fan LEDs Fan Description I/O fan LED I/O fan LED Primary CPU fan and secondary CPU fan LED Primary or secondary external system fan LED Primary and secondary external system fan LED LED Indication No light Green light Amber light Table 3-12 Hot-Plug Fan LED Status Status Power is not applied to the fan Power is applied to the fan, and the fan is functional Fan has failed 3-30 Compaq ProLiant 6400R Setup and Installation Guide 2. Verify the status of the fans by noting the LEDs at the fan location. 2 1 5 4 3 Figure 3-26.
Compaq ProLiant 6400R Setup and Installation Guide
Page 85
Installing a hot-plug external rear CPU fan 3. Installing a hot-plug fan 2 2 1 Figure 3-29. 3-32 Compaq ProLiant 6400R Setup and Installation Guide 2 1 Figure 3-28. Replace the top access panel to complete the installation.
Installing a hot-plug external rear CPU fan 3. Installing a hot-plug fan 2 2 1 Figure 3-29. 3-32 Compaq ProLiant 6400R Setup and Installation Guide 2 1 Figure 3-28. Replace the top access panel to complete the installation.
Compaq ProLiant 6400R Setup and Installation Guide
Page 134
...Compaq Integrated Remote Console (IRC) 1-9 Compaq Management CD 7-2 Compaq NC Fast Ethernet Dual 10/100 Network Interface Controller 1-3 Compaq Operating System Utilities 1-8 Compaq Optional Installation Service 2-1 Compaq ProLiant Storage System 1-10 Compaq Remote Insight 1-1 Compaq Smart Array Controller 1-7 Compaq SmartStart 1-7 Compaq Survey Utility 1-9 viewing IML 4-3 Compaq System Configuration Utility 7-1 Compaq...6-2 controllers 1-10 Dual Channel 10/100 Autosensing Ethernet NIC 1-1 controllers, SCSI 6-3 CPU fans 1-3 D DAAD 1-8 data loss 3-23 default configuration 2-24 overview 2-24 device...
...Compaq Integrated Remote Console (IRC) 1-9 Compaq Management CD 7-2 Compaq NC Fast Ethernet Dual 10/100 Network Interface Controller 1-3 Compaq Operating System Utilities 1-8 Compaq Optional Installation Service 2-1 Compaq ProLiant Storage System 1-10 Compaq Remote Insight 1-1 Compaq Smart Array Controller 1-7 Compaq SmartStart 1-7 Compaq Survey Utility 1-9 viewing IML 4-3 Compaq System Configuration Utility 7-1 Compaq...6-2 controllers 1-10 Dual Channel 10/100 Autosensing Ethernet NIC 1-1 controllers, SCSI 6-3 CPU fans 1-3 D DAAD 1-8 data loss 3-23 default configuration 2-24 overview 2-24 device...