Page 15
... SNMPv2c Work 24-5 SNMPv1 and SNMPv2c Default Configuration 24-6 Configuring SNMPv1 and SNMPv2c from an NMS 24-6 Configuring SNMPv1 and SNMPv2c from the CLI 24-6 SNMPv1 and SNMPv2c Enhancements in Software Release 7.5(1) 24-8 Understanding SNMPv3 24-11 Benefits of SNMPv3 24-11 SNMP Entity 24-11 Configuring SNMPv3 from an NMS 24-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration...
... SNMPv2c Work 24-5 SNMPv1 and SNMPv2c Default Configuration 24-6 Configuring SNMPv1 and SNMPv2c from an NMS 24-6 Configuring SNMPv1 and SNMPv2c from the CLI 24-6 SNMPv1 and SNMPv2c Enhancements in Software Release 7.5(1) 24-8 Understanding SNMPv3 24-11 Benefits of SNMPv3 24-11 SNMP Entity 24-11 Configuring SNMPv3 from an NMS 24-14 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration...
Software Guide
Page 16
Contents Configuring SNMPv3 from the CLI 24-14 Using CiscoWorks2000 24-17 25 C H A P T E R Configuring RMON 25-1 Understanding How RMON Works 25-1 Enabling RMON 25-2 Viewing RMON Data 25-2 Supported RMON and RMON2 MIB Objects 25-2 26 C H A P T ... Requirements 26-8 Understanding How RSPAN Works 26-8 RSPAN Configuration Guidelines 26-9 Configuring RSPAN 26-10 RSPAN Configuration Examples 26-13 27 C H A P T E R Administering the Switch 27-1 Setting the System Name and System Prompt 27-1 Configuring the System Name and Prompt 27-2 Setting the System Contact and Location 27-3 Setting the...
Contents Configuring SNMPv3 from the CLI 24-14 Using CiscoWorks2000 24-17 25 C H A P T E R Configuring RMON 25-1 Understanding How RMON Works 25-1 Enabling RMON 25-2 Viewing RMON Data 25-2 Supported RMON and RMON2 MIB Objects 25-2 26 C H A P T ... Requirements 26-8 Understanding How RSPAN Works 26-8 RSPAN Configuration Guidelines 26-9 Configuring RSPAN 26-10 RSPAN Configuration Examples 26-13 27 C H A P T E R Administering the Switch 27-1 Setting the System Name and System Prompt 27-1 Configuring the System Name and Prompt 27-2 Setting the System Contact and Location 27-3 Setting the...
Software Guide
Page 24
... Protocol (GVRP) on the switch. Configuring SNMP Describes how to configure Inter-Switch Link (ISL) and IEEE 802.1Q VLAN trunks on Fast Ethernet and Gigabit Ethernet ports. xxiv Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 ... 24 Chapter 25 Chapter 26 Title Description Configuring VTP Describes how to configure Remote Monitoring (RMON) on the switch. Configuring Multicast Services Describes how to configure unicast flood blocking on the switch. Configuring Unicast Flood Blocking Describes how to configure Cisco...
... Protocol (GVRP) on the switch. Configuring SNMP Describes how to configure Inter-Switch Link (ISL) and IEEE 802.1Q VLAN trunks on Fast Ethernet and Gigabit Ethernet ports. xxiv Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 ... 24 Chapter 25 Chapter 26 Title Description Configuring VTP Describes how to configure Remote Monitoring (RMON) on the switch. Configuring Multicast Services Describes how to configure unicast flood blocking on the switch. Configuring Unicast Flood Blocking Describes how to configure Cisco...
Software Guide
Page 42
...you specify a MAC address, which you can also configure IP aliases on the switch, which must be six hexadecimal numbers separated by hyphens, as shown in this example: 00-00-0c-24-d2-fe Specifying IP Addresses, Host Names, and IP Aliases Some commands require an... IP address, IP host name, or IP alias. For information on the switch, you can be designated in place of IP addresses. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-...
...you specify a MAC address, which you can also configure IP aliases on the switch, which must be six hexadecimal numbers separated by hyphens, as shown in this example: 00-00-0c-24-d2-fe Specifying IP Addresses, Host Names, and IP Aliases Some commands require an... IP address, IP host name, or IP alias. For information on the switch, you can be designated in place of IP addresses. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-...
Software Guide
Page 43
...: . 33: . 34: . 35: . 36: . 37: . 38: . 39: . 8: . 16: . 24: . 32: . 40: . 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 2-9 WS-X4012 bootrom version 4.5(1), built on the Catalyst 4912G, the Catalyst 2948G, and the Catalyst 2980G switches are in 5 seconds. enet console port: . switch port 2: . switch bandwidth: . switch port 10: . Chapter 2 Using the Command-Line Interface ROM...
...: . 33: . 34: . 35: . 36: . 37: . 38: . 39: . 8: . 16: . 24: . 32: . 40: . 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 2-9 WS-X4012 bootrom version 4.5(1), built on the Catalyst 4912G, the Catalyst 2948G, and the Catalyst 2980G switches are in 5 seconds. enet console port: . switch port 2: . switch bandwidth: . switch port 10: . Chapter 2 Using the Command-Line Interface ROM...
Software Guide
Page 63
...have not disabled the port), the port status is shown as errdisable. This feature is 30 to 86,400 seconds (30 seconds to 24 hours). Console> (enable) This example shows how to set the errdisable timeout interval to 450 seconds: Console> (enable) set errdisable-timeout...enable or disable errdisable timeout for any ports are reenabled when the global timer times out. Console>(enable) 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 4-7 If so, only those ports that have been put in errdisable state due to causes other...
...have not disabled the port), the port status is shown as errdisable. This feature is 30 to 86,400 seconds (30 seconds to 24 hours). Console> (enable) This example shows how to set the errdisable timeout interval to 450 seconds: Console> (enable) set errdisable-timeout...enable or disable errdisable timeout for any ports are reenabled when the global timer times out. Console>(enable) 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 4-7 If so, only those ports that have been put in errdisable state due to causes other...
Software Guide
Page 64
... 2 ms 3 gateway_a.company.com (173.16.1.201) 6 ms 3 ms 3 ms 4 somehost.company.com (10.1.2.3) 3 ms * 2 ms Console> (enable) Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 4-8 78-15486-01 Configuring Ethernet and Fast Ethernet Ports Chapter 4 Configuring Ethernet and Fast Ethernet... Ping a remote host that will be enabled at the next timeout: Port ErrDisable Reason 3/1 udld 3/8 bpdu-guard 6/5 udld 7/24 duplex-mismatch Console> (enable) Checking Ethernet and Fast Ethernet Port Connectivity Note For more detailed information on the...
... 2 ms 3 gateway_a.company.com (173.16.1.201) 6 ms 3 ms 3 ms 4 somehost.company.com (10.1.2.3) 3 ms * 2 ms Console> (enable) Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 4-8 78-15486-01 Configuring Ethernet and Fast Ethernet Ports Chapter 4 Configuring Ethernet and Fast Ethernet... Ping a remote host that will be enabled at the next timeout: Port ErrDisable Reason 3/1 udld 3/8 bpdu-guard 6/5 udld 7/24 duplex-mismatch Console> (enable) Checking Ethernet and Fast Ethernet Port Connectivity Note For more detailed information on the...
Software Guide
Page 68
... are segmented into groups of bandwidth. Table 5-4 lists the uplink module port IDs for Module WS-X4424-GB-RJ45 1, 2, 3, 4 5, 6, 7, 8 9, 10, 11, 12 13, 14, 15, 16 17, 18, 19, 20 21, 22, 23, 24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 5-4 78-15486-01 The average bandwidth that clients and servers...
... are segmented into groups of bandwidth. Table 5-4 lists the uplink module port IDs for Module WS-X4424-GB-RJ45 1, 2, 3, 4 5, 6, 7, 8 9, 10, 11, 12 13, 14, 15, 16 17, 18, 19, 20 21, 22, 23, 24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 5-4 78-15486-01 The average bandwidth that clients and servers...
Software Guide
Page 69
... inbound buffer is small, the default (and recommended) flow-control configuration for Module WS-X4448-GB-LX 1, 3, 5, 7, 9, 11, 13, 15 2, 4, 6, 8, 10, 17, 19, 21, 12, 14, 16 23, 25, 27, 29, 31 18, 20, 22, 24, 26, 28, 30, 32 33, 35, 37, 39, 41, 43,... ports has a buffer for module WS-X4448-GB-LX. These configurations are grouped for incoming frames to allow connected devices to the switch through a two-port Gigabit EtherChannel trunk link providing 2-Gbps bandwidth. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 5-5 ...
... inbound buffer is small, the default (and recommended) flow-control configuration for Module WS-X4448-GB-LX 1, 3, 5, 7, 9, 11, 13, 15 2, 4, 6, 8, 10, 17, 19, 21, 12, 14, 16 23, 25, 27, 29, 31 18, 20, 22, 24, 26, 28, 30, 32 33, 35, 37, 39, 41, 43,... ports has a buffer for module WS-X4448-GB-LX. These configurations are grouped for incoming frames to allow connected devices to the switch through a two-port Gigabit EtherChannel trunk link providing 2-Gbps bandwidth. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 5-5 ...
Software Guide
Page 119
...priority values: 0, 4096, 8192, 12,288, 16,384, 20,480, 24,576, 28,672, 32,768, 36,864, 40,960, 45,056, 49,152, 53,248, 57,344, or 61,440. When the switch is in PVST+ mode with the system ID extension (that value. Chapter 7...default PVST+ configuration. To set spantree priority bridge_ID_priority [vlan] show spantree [vlan] [active] 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 7-23 The switch creates the bridge ID priority by combining the VLAN bridge priority with MAC address reduction enabled, you can enter ...
...priority values: 0, 4096, 8192, 12,288, 16,384, 20,480, 24,576, 28,672, 32,768, 36,864, 40,960, 45,056, 49,152, 53,248, 57,344, or 61,440. When the switch is in PVST+ mode with the system ID extension (that value. Chapter 7...default PVST+ configuration. To set spantree priority bridge_ID_priority [vlan] show spantree [vlan] [active] 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 7-23 The switch creates the bridge ID priority by combining the VLAN bridge priority with MAC address reduction enabled, you can enter ...
Software Guide
Page 120
... Vlan Port-State Cost Prio Portfast Channel_id 1/1 1 not-connected 4 32 disabled 0 1/2 1 not-connected 4 32 disabled 0 2/1 1 not-connected 100 32 disabled 0 2/2 1 not-connected 100 32 disabled 0 7-24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01
... Vlan Port-State Cost Prio Portfast Channel_id 1/1 1 not-connected 4 32 disabled 0 1/2 1 not-connected 4 32 disabled 0 2/1 1 not-connected 100 32 disabled 0 2/2 1 not-connected 100 32 disabled 0 7-24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01
Software Guide
Page 128
... Cost Designated Root Port VLANs mapped: 00-05-31-40-64-00 32769 (root priority:32768, sys ID ext:1) 20000 1/1 1,74 7-32 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Configuring the MISTP Bridge ID Priority You can set spantree mode mistp PVST+ database cleaned up...set 16 possible bridge priority values: 0, 4096, 8192, 12,288, 16,384, 20,480, 24,576, 28,672, 32,768, 36,864, 40,960, 45,056, 49,152, 53,248, 57,344, and 61,440. The switch combines the bridge priority value with the system ID extension (the ID of the MISTP...
... Cost Designated Root Port VLANs mapped: 00-05-31-40-64-00 32769 (root priority:32768, sys ID ext:1) 20000 1/1 1,74 7-32 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Configuring the MISTP Bridge ID Priority You can set spantree mode mistp PVST+ database cleaned up...set 16 possible bridge priority values: 0, 4096, 8192, 12,288, 16,384, 20,480, 24,576, 28,672, 32,768, 36,864, 40,960, 45,056, 49,152, 53,248, 57,344, and 61,440. The switch combines the bridge priority value with the system ID extension (the ID of the MISTP...
Software Guide
Page 137
...-instance for VLANs 22 and 24: Console> (enable) set spantree root secondary 22,24 dia 5 hello 1 VLANs 22,24 bridge priority set to 1 second. The reconfiguration delay depends on page 7-44. To do so, you must reduce the value of end stations. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release...
...-instance for VLANs 22 and 24: Console> (enable) set spantree root secondary 22,24 dia 5 hello 1 VLANs 22,24 bridge priority set to 1 second. The reconfiguration delay depends on page 7-44. To do so, you must reduce the value of end stations. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release...
Software Guide
Page 146
... instance, perform this task in MST mode. Command set spantree priority bridge_priority mst [instance] show spantree mst config Current (NVRAM) MST Region Configuration: Configuration Name:cisco Revision:1 Instance VLANs IST 1,51-4094 1 2-20 2 21-30 3 31-40 4 41-50 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 -...8192, 12,288, 16,384, 20,480, 24,576, 28,672, 32,768, 36,864, 40,960, 45,056, 49,152, 53,248, 57,344, and 61,440. Console> (enable) 7-50 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Console...
... instance, perform this task in MST mode. Command set spantree priority bridge_priority mst [instance] show spantree mst config Current (NVRAM) MST Region Configuration: Configuration Name:cisco Revision:1 Instance VLANs IST 1,51-4094 1 2-20 2 21-30 3 31-40 4 41-50 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 -...8192, 12,288, 16,384, 20,480, 24,576, 28,672, 32,768, 36,864, 40,960, 45,056, 49,152, 53,248, 57,344, and 61,440. Console> (enable) 7-50 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Console...
Software Guide
Page 154
...26:05 8/20 4111 113913 Tue Nov 21 2000, 06:26:05 8/22 113917 113917 Tue Nov 21 2000, 06:26:05 8/24 4110 113922 Tue Nov 21 2000, 06:26:05 8/26 113926 113926 Tue Nov 21 2000, 06:26:05 8/28 4111 113931 ...shows the output of connected spanning tree ports by vlan VLAN Blocking Listening Learning Forwarding STP Active 1 6 4 2 0 12 7-58 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Portfast bpdu-filter disabled for bridge. Configuring Spanning Tree BPDU Skewing Chapter 7 Configuring Spanning Tree...
...26:05 8/20 4111 113913 Tue Nov 21 2000, 06:26:05 8/22 113917 113917 Tue Nov 21 2000, 06:26:05 8/24 4110 113922 Tue Nov 21 2000, 06:26:05 8/26 113926 113926 Tue Nov 21 2000, 06:26:05 8/28 4111 113931 ...shows the output of connected spanning tree ports by vlan VLAN Blocking Listening Learning Forwarding STP Active 1 6 4 2 0 12 7-58 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Portfast bpdu-filter disabled for bridge. Configuring Spanning Tree BPDU Skewing Chapter 7 Configuring Spanning Tree...
Software Guide
Page 200
... in privileged mode: Step 1 Step 2 Step 3 Step 4 Task Define the VTP domain name. Console> (enable) show vtp domain 9-24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 To configure the switch as using the above example without specifying the vlan keyword results in the same configuration as a VTP version...
... in privileged mode: Step 1 Step 2 Step 3 Step 4 Task Define the VTP domain name. Console> (enable) show vtp domain 9-24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 To configure the switch as using the above example without specifying the vlan keyword results in the same configuration as a VTP version...
Software Guide
Page 230
Configuring Private VLANs Chapter 10 Configuring VLANs 10-24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01
Configuring Private VLANs Chapter 10 Configuring VLANs 10-24 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01
Software Guide
Page 271
...Timers(milliseconds) Join = 200 Leave = 600 LeaveAll = 10000 Port based GVRP Configuration: Port GVRP Status Registration 2/1-2,3/1-8,7/1-24,8/1-24 Enabled Normal GVRP Participants running on page 13-2. Console> Enabling GVRP on Individual 802.1Q Trunk Ports Note You...the configuration. GVRP dynamic VLAN creation is currently enabled on the switch. set gvrp enable GVRP enabled Console> (enable) show gvrp configuration 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 13-3 However, in privileged mode:...
...Timers(milliseconds) Join = 200 Leave = 600 LeaveAll = 10000 Port based GVRP Configuration: Port GVRP Status Registration 2/1-2,3/1-8,7/1-24,8/1-24 Enabled Normal GVRP Participants running on page 13-2. Console> Enabling GVRP on Individual 802.1Q Trunk Ports Note You...the configuration. GVRP dynamic VLAN creation is currently enabled on the switch. set gvrp enable GVRP enabled Console> (enable) show gvrp configuration 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 13-3 However, in privileged mode:...
Software Guide
Page 274
...) set gvrp applicant active 4/2-3,4/9-10,4/12-24 Applicant was set a timer value that does not support per-VLAN STP, configure the GVRP active applicant state on the port. Console> (enable) Use the normal keyword to return to 350 ms. 13-6 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01...
...) set gvrp applicant active 4/2-3,4/9-10,4/12-24 Applicant was set a timer value that does not support per-VLAN STP, configure the GVRP active applicant state on the port. Console> (enable) Use the normal keyword to return to 350 ms. 13-6 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01...
Software Guide
Page 297
..., GVRP uses the same timers.) You can modify the default GARP timer values on the switch. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 15-13 Console> (enable) show gmrp configuration Global GMRP Configuration...port 2/10. Chapter 15 Configuring Multicast Services Configuring GMRP Enabled Normal Enabled Fixed Console> (enable) Disabled Disabled 1/1-4 2/1-9,2/11-48 3/1-24 5/1 2/10 Setting Forbidden Registration Mode Configuring a port in privileged mode: Step 1 Step 2 Task Configure forbidden registration on a...
..., GVRP uses the same timers.) You can modify the default GARP timer values on the switch. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 15-13 Console> (enable) show gmrp configuration Global GMRP Configuration...port 2/10. Chapter 15 Configuring Multicast Services Configuring GMRP Enabled Normal Enabled Fixed Console> (enable) Disabled Disabled 1/1-4 2/1-9,2/11-48 3/1-24 5/1 2/10 Setting Forbidden Registration Mode Configuring a port in privileged mode: Step 1 Step 2 Task Configure forbidden registration on a...