CS300 Silicon Pyranometer
Page 2
... in materials and workmanship under this warranty is incomplete, the product will not process any Campbell Scientific, Inc. is : CAMPBELL SCIENTIFIC, INC. The following contact information is for twelve (12) months from date of the...Campbell Scientific, Inc. Batteries have been subjected to the customer at the customer's expense. Campbell Scientific, Inc. directly. Campbell Scientific will be issued. Products may cause health or safety concerns for a particular purpose. If the form is warranted by Campbell Scientific, Inc. Warranty and Assistance The CS300...
... in materials and workmanship under this warranty is incomplete, the product will not process any Campbell Scientific, Inc. is : CAMPBELL SCIENTIFIC, INC. The following contact information is for twelve (12) months from date of the...Campbell Scientific, Inc. Batteries have been subjected to the customer at the customer's expense. Campbell Scientific, Inc. directly. Campbell Scientific will be issued. Products may cause health or safety concerns for a particular purpose. If the form is warranted by Campbell Scientific, Inc. Warranty and Assistance The CS300...
CS300 Silicon Pyranometer
Page 3
... 4 Tables 4-1. Wiring for Average Flux and Total Flux Density in SI and English Units 5 5-2. CS300 Table of this document. General Description 1 2. Specifications 1 3. Wiring 4 5. Programming 4 5.1 Example Programs 5 5.1.1 CR1000 Example Program 5 5.1.2 CR10X Example Program 6 5.2 Total Solar Radiation 8 6. CM225 Pyranometer Mounting ...Acrobat® bookmarks tab for links to the printed version of Contents PDF viewers note: These page numbers refer to specific sections. 1. Connections to Campbell Scientific Dataloggers 4 5-1. Maintenance and Calibration 8 7.
... 4 Tables 4-1. Wiring for Average Flux and Total Flux Density in SI and English Units 5 5-2. CS300 Table of this document. General Description 1 2. Specifications 1 3. Wiring 4 5. Programming 4 5.1 Example Programs 5 5.1.1 CR1000 Example Program 5 5.1.2 CR10X Example Program 6 5.2 Total Solar Radiation 8 6. CM225 Pyranometer Mounting ...Acrobat® bookmarks tab for links to the printed version of Contents PDF viewers note: These page numbers refer to specific sections. 1. Connections to Campbell Scientific Dataloggers 4 5-1. Maintenance and Calibration 8 7.
CS300 Silicon Pyranometer
Page 8
TABLE 4-1. The voltage signal from the CS300 is measured using Campbell Scientific's Short Cut Program Builder software. Dataloggers that use CRBasic include the CR200(X), CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X). Single-Ended RED Analog Input BLACK Ground/AG 500 to Campbell Scientific Dataloggers Color Red Black Clear Wire Label Signal Signal Reference Shield CR9000(X) CR5000...
TABLE 4-1. The voltage signal from the CS300 is measured using Campbell Scientific's Short Cut Program Builder software. Dataloggers that use CRBasic include the CR200(X), CR800, CR850, CR1000, CR3000, CR5000, and CR9000(X). Single-Ended RED Analog Input BLACK Ground/AG 500 to Campbell Scientific Dataloggers Color Red Black Clear Wire Label Signal Signal Reference Shield CR9000(X) CR5000...
CS300 Silicon Pyranometer
Page 13
...CR200(X) measurements, due to Campbell Scientific, Inc. Disconnect the sensor leads from the datalogger and use a DVM to 1000 Wm-2 radiation. Obtain an RMA number before returning the CS300 to the 0.6 mV CR200(X) resolution and the 0.2 mV/Wm-2 CS300 sensitivity. 9 Verify that... the sensor is correct for recalibration. 7. CS300 Pyranometer Recalibrate the CS300 every three years. No voltage indicates a problem with...
...CR200(X) measurements, due to Campbell Scientific, Inc. Disconnect the sensor leads from the datalogger and use a DVM to 1000 Wm-2 radiation. Obtain an RMA number before returning the CS300 to the 0.6 mV CR200(X) resolution and the 0.2 mV/Wm-2 CS300 sensitivity. 9 Verify that... the sensor is correct for recalibration. 7. CS300 Pyranometer Recalibrate the CS300 every three years. No voltage indicates a problem with...