Campbell Scientific 4WPB100 Support and Manuals

Get Help and Manuals for this Campbell Scientific item

View All Support Options Below
Free Campbell Scientific 4WPB100 manuals!
Problems with Campbell Scientific 4WPB100?

Ask a Question

Popular Campbell Scientific 4WPB100 Manual Pages

4WPB100, 4WPB1K PRT Terminal Input Modules - Page 1

HLG AG L H L AG H 4WPB100, 4WPB1K PRT Bridge Terminal Input Modules Revision: 12/06 Copyright © 1996-2006 Campbell Scientific, Inc.
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 2

...this number clearly on the outside of the problem, an RMA number will return such products by Campbell Scientific, Inc. Affiliate companies handle repairs for special, indirect, incidental, or consequential damages. CAMPBELL SCIENTIFIC, INC. is : CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC.'s obligation under normal use and service for twelve (12) months from defects in lieu...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 3

... numbers refer to Campbell Scientific Dataloggers..3 4-1. PRT in 4WPB1000 Based on Maximum Temperature and Input Voltage Range 3 4-2. Circuit Schematic 2 3-1. Wiring for 100 Ohm PRT in 4WPB100 Based on Maximum Temperature and Input Voltage Range 4 i 4WPB100, 4WPB1K Table of this document. Terminal Input Module 1 2-1. Excitation Voltage for links to specific sections. 1. Wiring...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 5

...for resistive bridge measurements, voltage dividers, and precision current shunts. Terminal Input Module 2. Specifications Current limiting 10 kOhm Resistor Tolerance @ 25 °C ±5% Power ...rating ±0.01% 4 ppm/°C 8 ppm/°C 0.25 W 1 The 4WPB100 and 4WPB1K are used to provide completion resistors for 4 wire half bridge measurements of 100 Ohm and 1...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 6

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules Vx HI LO HI LO GND 10k 5% H Rf Rf = 100 , 1k 0.01% L Rs GND ... 2; Circuit Schematic 3. The black excitation wire is connected to the next differential channel. Datalogger Ex1 1H 1L AG or 2H 2L 4WPB100 L G PRT FIGURE 3-1. The dashed lines in Figure 2-1 indicate the sensor wiring. When making 4 wire half bridge measurements, the...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 7

... 832 1664 790 1581 3 4WPB100, 4WPB1K PRT Bridge Terminal Input Modules TABLE 3-1. 4WPB100/4WPB1K Connections to the maximum ...Instruction 9 (used with CR10(X), 21X, and CR7). The result of maximum temperature and the input voltage ranges used with the different dataloggers. The excitation voltages used were chosen with the first measurement range not set to Campbell Scientific...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 10

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 4.3 CR7 1: Full Bridge w/mv Excit (P9) 1: 1 Reps 2: 3 ± 15 mV Slow Range 3: 3 ± 15 mV Slow Range 4: 1 In Card 5: 1 DIFF Channel 6: 1 Ex Card 7: 1 Ex Channel 8: 1 ...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 11

... allows the use of the four wire half bridge Instruction is: V2 V1 the voltage drop is kept to...a minimum. This insures that noise in the excitation leads. 4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 4.5 CR1000 'CR1000 Series Datalogger Public Rs_R0, Temp_C DataTable (...to be made on signal noise and that allow one set of wires to measure the PRT. Because the fixed resistor...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 12

...error of Rf/R0 is greatest. Thus, a multiplier of 0.05 °C at 125 °C. The fixed resistor must be 2.102 V to 2.1 volts (e.g., if the 10 kOhm resistor is : V2 = I ⋅ Rs = Rs V1 I ⋅ R f R f 8 For example, if it is decided to set...33 °C at 60 °C. 4WPB100, 4WPB1K PRT Bridge Terminal Input Modules The RTD Instruction (16) computes the temperature (°C)...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 13

...calibration, connect the PRT to the datalogger and program the datalogger to Ro/Rf since Rs=Ro. 4WPB100, 4WPB1K PRT Bridge Terminal Input Modules With the PRT at 0 °C, Rs=Ro. By making a measurement with the 4 wire ..., which is equal to measure the PRT with the PRT in an ice bath, errors in an ice bath (@ 0°C; Thus, the above result becomes Ro/Rf, the reciprocal of the bridge ...
4WPB100, 4WPB1K PRT Terminal Input Modules - Page 14

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules This is a blank page. 10

Campbell Scientific 4WPB100 Reviews

Do you have an experience with the Campbell Scientific 4WPB100 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific 4WPB100 Search Terms

The following terms are frequently used to search for Campbell Scientific 4WPB100 support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific 4WPB100.
Manuals / Documents
Download any of our Campbell Scientific 4WPB100 manuals for free!

We have the following 1 documents available for the Campbell Scientific 4WPB100:
  • 4WPB100, 4WPB1K PRT Terminal Input Modules
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific 4WPB100 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific 4WPB100 user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.