User Manual
Page 5
... Chapter 6: Driver installation 6.1 RAID driver installation 6-1 6.1.1 Creating a RAID driver disk 6-1 6.1.2 Installing the Intel® ICH7R RAID controller driver .... 6-3 6.2 LAN driver installation 6-7 6.2.1 Windows® 2000/2003 Server 6-7 6.2.2 Red Hat® Linux 9.0 6-9 6.3 VGA driver installation 6-11 6.3.1 Windows® 2000 Server 6-11 6.3.2 Windows® 2003 Server 6-12 6.3.3 Red Hat® Linux 9.0 6-12 Appendix: Reference information...
... Chapter 6: Driver installation 6.1 RAID driver installation 6-1 6.1.1 Creating a RAID driver disk 6-1 6.1.2 Installing the Intel® ICH7R RAID controller driver .... 6-3 6.2 LAN driver installation 6-7 6.2.1 Windows® 2000/2003 Server 6-7 6.2.2 Red Hat® Linux 9.0 6-9 6.3 VGA driver installation 6-11 6.3.1 Windows® 2000 Server 6-11 6.3.2 Windows® 2003 Server 6-12 6.3.3 Red Hat® Linux 9.0 6-12 Appendix: Reference information...
User Manual
Page 10
P5MT-M specifications summary CPU Chipset Front Side Bus...x 240-pin DIMM sockets support unbuffered ECC 667/533 MHz DDR2 memory modules Supports 256 MB up to 6 additional ports) ASUS Q-Fan ASUS CrashFree BIOS 2 ASUS MyLogo2™ ASUS EZ FLash AMI BIOS, 8 Mb FWH, Green, PnP, DMI2.0a, ACPI 2.0a, SMBIOS 2.3 1 x PS/2 ...(RJ-45) ports 1 x VGA port 1 x Parallel port (continued on the rear panel, 3 connectors at mid-board for ASUS® Server Management Board ATI® RAGE-XL PCI-based VGA controller Dual Broadcom BCM5721 Gigabit LAN controller (PCI Express 1.0a specifications compliant) Intel...
P5MT-M specifications summary CPU Chipset Front Side Bus...x 240-pin DIMM sockets support unbuffered ECC 667/533 MHz DDR2 memory modules Supports 256 MB up to 6 additional ports) ASUS Q-Fan ASUS CrashFree BIOS 2 ASUS MyLogo2™ ASUS EZ FLash AMI BIOS, 8 Mb FWH, Green, PnP, DMI2.0a, ACPI 2.0a, SMBIOS 2.3 1 x PS/2 ...(RJ-45) ports 1 x VGA port 1 x Parallel port (continued on the rear panel, 3 connectors at mid-board for ASUS® Server Management Board ATI® RAGE-XL PCI-based VGA controller Dual Broadcom BCM5721 Gigabit LAN controller (PCI Express 1.0a specifications compliant) Intel...
User Manual
Page 16
The uniprocessor server chipset integrates EM64T support and four Serial ATA ports enabled through the Serial ATA II interfaces controlled by the Intel® ICH7R. The SATA II ...
The uniprocessor server chipset integrates EM64T support and four Serial ATA ports enabled through the Serial ATA II interfaces controlled by the Intel® ICH7R. The SATA II ...
User Manual
Page 28
...Threading Technology item in the 775-land package with Hyper-Threading Technology. • Hyper-Threading Technology is supported under Windows® XP/2003 Server and Linux 2.4.x (kernel) and later versions only. Notes on this motherboard: 1. To use the Hyper-Threading compiler to Enabled. Close ... motherboard supports Intel® Pentium® 4 CPUs in the BIOS to ensure system stability and performance. • Installing Windows® 2003 Server or later version is set to compile the code. B The CPU fits in BIOS before installing a supported operating system. • For...
...Threading Technology item in the 775-land package with Hyper-Threading Technology. • Hyper-Threading Technology is supported under Windows® XP/2003 Server and Linux 2.4.x (kernel) and later versions only. Notes on this motherboard: 1. To use the Hyper-Threading compiler to Enabled. Close ... motherboard supports Intel® Pentium® 4 CPUs in the BIOS to ensure system stability and performance. • Installing Windows® 2003 Server or later version is set to compile the code. B The CPU fits in BIOS before installing a supported operating system. • For...
User Manual
Page 34
...® XP Professional Windows® XP 64-bit Edition Windows® Server 2003 Web Edition Windows® Server 2003 Standard Edition Windows® Server 2003 Enterprise Edition Windows® Server 2003 Datacenter Edition Windows® Server 2003 Enterprise 64-bit Edition Windows® Server 2003 Datacenter 64-bit Edition Maximum physical memory supported 4 GB 4 GB 8 GB...
...® XP Professional Windows® XP 64-bit Edition Windows® Server 2003 Web Edition Windows® Server 2003 Standard Edition Windows® Server 2003 Enterprise Edition Windows® Server 2003 Datacenter Edition Windows® Server 2003 Enterprise 64-bit Edition Windows® Server 2003 Datacenter 64-bit Edition Maximum physical memory supported 4 GB 4 GB 8 GB...
User Manual
Page 52
12. P5MT-M ® LAN2 P5MT-M TRPWR connector GND SYS-THEAMAL2 TRPWR1 2-32 Chapter 2: Hardware information Ambient thermal sensor connector (2-pin TRPWR1) If you want additional thermal monitoring, connect the thermal sensor cable with a thermistor (of 1ºK or at 25ºC, B=3435) to this connector. BMC connector (16-pin BMCCONN1) This connector is for an ASUS server management card. +5VSB +5VSB BMC SMBCLK 12CCLK1 PSON# BMC_RST# PWROK PSONEN# P5MT-M ® LAN2 BMCCONN1 P5MT-M BMC connector +5VSB +5VSB BMC SMBDATA 12CDATA1 FP_PWRBTN# BMC_PRESENT# BMC_SMI# GND 13.
12. P5MT-M ® LAN2 P5MT-M TRPWR connector GND SYS-THEAMAL2 TRPWR1 2-32 Chapter 2: Hardware information Ambient thermal sensor connector (2-pin TRPWR1) If you want additional thermal monitoring, connect the thermal sensor cable with a thermistor (of 1ºK or at 25ºC, B=3435) to this connector. BMC connector (16-pin BMCCONN1) This connector is for an ASUS server management card. +5VSB +5VSB BMC SMBCLK 12CCLK1 PSON# BMC_RST# PWROK PSONEN# P5MT-M ® LAN2 BMCCONN1 P5MT-M BMC connector +5VSB +5VSB BMC SMBDATA 12CDATA1 FP_PWRBTN# BMC_PRESENT# BMC_SMI# GND 13.
User Manual
Page 53
...if there is for the locator button. Auxiliary panel connector (20-pin AUX_PANEL1) This connector supports several server system functions. Connect the Locator LED 2 cable to this connector. This button queries the state of ...NC I2C_4_CLK# GND I2C_4_DATA# +5VSB LAN1_LINKACTLED+ LAN1_LINKACTLEDLAN2_LINKACTLEDLAN2_LINKACTLED+ P5MT-M ® LAN2 AUX_PANEL1 PIN1 +5VSB CASEOPEN GND LOCATORLED1+ LOCATORLED1LOCATORBTN# GND LOCATORLED2LOCATORLED2+ P5MT-M Auxiliary panel connector • Chassis Intrusion connector (3-pin CASEOPEN) This lead is no LAN1 connection (e.g. ASUS P5MT-M 2-33
...if there is for the locator button. Auxiliary panel connector (20-pin AUX_PANEL1) This connector supports several server system functions. Connect the Locator LED 2 cable to this connector. This button queries the state of ...NC I2C_4_CLK# GND I2C_4_DATA# +5VSB LAN1_LINKACTLED+ LAN1_LINKACTLEDLAN2_LINKACTLEDLAN2_LINKACTLED+ P5MT-M ® LAN2 AUX_PANEL1 PIN1 +5VSB CASEOPEN GND LOCATORLED1+ LOCATORLED1LOCATORBTN# GND LOCATORLED2LOCATORLED2+ P5MT-M Auxiliary panel connector • Chassis Intrusion connector (3-pin CASEOPEN) This lead is no LAN1 connection (e.g. ASUS P5MT-M 2-33
User Manual
Page 58
... to soft-off mode, depending on the BIOS setting. 3.2 Turning off the computer 3.2.1 Using the OS shut down function If you are using Windows® Server 2003: 1. Click the S t a r t button then select T u r n O f f C o m p u t e r . 2. The power supply should turn off mode regardless of the ... to shut down the computer. 3. Click the S t a r t button then click S h u t D o w n . . . 2. If you are using Windows® Server 2000: 1. Make sure that the S h u t D o w n option button is ON, pressing the power switch for less than four seconds puts the system to sleep mode or...
... to soft-off mode, depending on the BIOS setting. 3.2 Turning off the computer 3.2.1 Using the OS shut down function If you are using Windows® Server 2003: 1. Click the S t a r t button then select T u r n O f f C o m p u t e r . 2. The power supply should turn off mode regardless of the ... to shut down the computer. 3. Click the S t a r t button then click S h u t D o w n . . . 2. If you are using Windows® Server 2000: 1. Make sure that the S h u t D o w n option button is ON, pressing the power switch for less than four seconds puts the system to sleep mode or...
User Manual
Page 99
... and a RAID 1 set , copy first the RAID driver from a hard disk drive included in parallel, interleaved stacks. ASUS P5MT-M 5-1 This RAID configuration provides data protection and increases fault tolerance to section "2. The Intel® Matrix Storage technology supported by...; M a t r i x S t o r a g e. In some instances, a RAID 10 configuration can sustain multiple simultaneous drive failure. 5.1 RAID configurations The server system/motherboard comes with RAID 1 segments whose segments are RAID 1 arrays. Refer to the entire system. If one drive to read and write data in...
... and a RAID 1 set , copy first the RAID driver from a hard disk drive included in parallel, interleaved stacks. ASUS P5MT-M 5-1 This RAID configuration provides data protection and increases fault tolerance to section "2. The Intel® Matrix Storage technology supported by...; M a t r i x S t o r a g e. In some instances, a RAID 10 configuration can sustain multiple simultaneous drive failure. 5.1 RAID configurations The server system/motherboard comes with RAID 1 segments whose segments are RAID 1 arrays. Refer to the entire system. If one drive to read and write data in...
User Manual
Page 103
... . The default value indicates the maximum allowed capacity. 8. Are you sure you want to 128 KB. ASUS P5MT-M 5-5 The available stripe size values range from 4 KB to create this volume? (Y/N): 9. T I P : We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for the RAID 0 array, then...
... . The default value indicates the maximum allowed capacity. 8. Are you sure you want to 128 KB. ASUS P5MT-M 5-5 The available stripe size values range from 4 KB to create this volume? (Y/N): 9. T I P : We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for the RAID 0 array, then...
User Manual
Page 105
... recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used to 128 KB. C r e a t e R A I D L e v e l item is highlighted, press the up /down arrow key to select the stripe size for the RAID 10 array, then press . This screen appears. When the R A I D V o l u m e, then press . ASUS P5MT-M 5-7 Creating a RAID 10 set...
... recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used to 128 KB. C r e a t e R A I D L e v e l item is highlighted, press the up /down arrow key to select the stripe size for the RAID 10 array, then press . This screen appears. When the R A I D V o l u m e, then press . ASUS P5MT-M 5-7 Creating a RAID 10 set...
User Manual
Page 107
... capacity that you want to select. This warning message appears. T I P : We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for the RAID 5 array, then press . ASUS P5MT-M 5-9 A small triangle marks the selected drive. Key in creating the volume. [↑↓]-Previous/Next [SPACE]-Selects...
... capacity that you want to select. This warning message appears. T I P : We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for the RAID 5 array, then press . ASUS P5MT-M 5-9 A small triangle marks the selected drive. Key in creating the volume. [↑↓]-Previous/Next [SPACE]-Selects...
User Manual
Page 115
.... 9. When creating a RAID 1 or a RAID 10 set, select S t r i p e S i z e from the menu, then press . For server systems, we recommend a higher array block size for audio and video editing, we recommend that you use a lower array block size. ASUS P5MT-M 5-17 Select the RAID level from the L o g i c a l D r i v e menu, then press . Key-in the stripe size...
.... 9. When creating a RAID 1 or a RAID 10 set, select S t r i p e S i z e from the menu, then press . For server systems, we recommend a higher array block size for audio and video editing, we recommend that you use a lower array block size. ASUS P5MT-M 5-17 Select the RAID level from the L o g i c a l D r i v e menu, then press . Key-in the stripe size...
User Manual
Page 136
...\Intel\Driver\Makedisk\F6flpy32 The 64-bit OS RAID driver disk for the Intel® ICH7R is located in Windows® 2000/2003 Server environment: 1. Windows® 2000/2003 Server To create a RAID driver disk in : \Drivers\Chipset\ICH\Intel\Driver\Makedisk\F6flpy64 3. Insert a formatted high-density floppy disk to complete the...
...\Intel\Driver\Makedisk\F6flpy32 The 64-bit OS RAID driver disk for the Intel® ICH7R is located in Windows® 2000/2003 Server environment: 1. Windows® 2000/2003 Server To create a RAID driver disk in : \Drivers\Chipset\ICH\Intel\Driver\Makedisk\F6flpy64 3. Insert a formatted high-density floppy disk to complete the...
User Manual
Page 137
... to specify an additional device. ASUS P5MT-M 6-3 Press when the message "P r e s s F 6 i f y o u n e e d t o i n s t a l l a t h i r d p a r t y S C S I o r R A I D d r i v e r . . ." Boot the computer using the Windows® 2000/2003 Server installation CD. appears at the bottom of the screen. 3. 6.1.2 Installing the Intel® ICH7R RAID controller driver Windows® 2000/2003 Server OS During Windows® 2000/2003 Server OS installation To install the...
... to specify an additional device. ASUS P5MT-M 6-3 Press when the message "P r e s s F 6 i f y o u n e e d t o i n s t a l l a t h i r d p a r t y S C S I o r R A I D d r i v e r . . ." Boot the computer using the Windows® 2000/2003 Server installation CD. appears at the bottom of the screen. 3. 6.1.2 Installing the Intel® ICH7R RAID controller driver Windows® 2000/2003 Server OS During Windows® 2000/2003 Server OS installation To install the...
User Manual
Page 139
... to install the drivers. ASUS P5MT-M 6-5 Click C a n c e l. 3. Click N e x t. 8. When found, click N e x t to the floppy disk drive. 9. The wizard searches the RAID controller drivers. Restart the computer, then log on an existing Windows® 2000/2003 Server OS: 1. Right-click the... r i v e r button. 7. The U p g r a d e D e v i c e D r i v e r W i z a r d window appears. To an existing Windows® 2000/2003 Server OS To install the Intel® ICH7R RAID controller driver on with A d m i n i s t r a t o r privileges. 2. Right-click the M y C o m p u t e r icon on the...
... to install the drivers. ASUS P5MT-M 6-5 Click C a n c e l. 3. Click N e x t. 8. When found, click N e x t to the floppy disk drive. 9. The wizard searches the RAID controller drivers. Restart the computer, then log on an existing Windows® 2000/2003 Server OS: 1. Right-click the... r i v e r button. 7. The U p g r a d e D e v i c e D r i v e r W i z a r d window appears. To an existing Windows® 2000/2003 Server OS To install the Intel® ICH7R RAID controller driver on with A d m i n i s t r a t o r privileges. 2. Right-click the M y C o m p u t e r icon on the...
User Manual
Page 141
... the Broadcom® Gigabit LAN controller drivers. 6.2.1 Windows® 2000/2003 Server To install the Broadcom® Gigabit LAN controller driver on a Windows® 2000/2003 Server OS: 1. 6.2 LAN driver installation This section provides instructions on how to ...begin installation. Click C a n c e l to close this window. • If A u t o r u n is enabled in your computer. • Windows® automatically detects the LAN controllers and displays a New Hardware Found window. ASUS P5MT...
... the Broadcom® Gigabit LAN controller drivers. 6.2.1 Windows® 2000/2003 Server To install the Broadcom® Gigabit LAN controller driver on a Windows® 2000/2003 Server OS: 1. 6.2 LAN driver installation This section provides instructions on how to ...begin installation. Click C a n c e l to close this window. • If A u t o r u n is enabled in your computer. • Windows® automatically detects the LAN controllers and displays a New Hardware Found window. ASUS P5MT...
User Manual
Page 145
... detects the LAN controller and displays a N e w H a r d w a r e F o u n d window. Click C a n c e l to the optical drive. Click N e x t. ASUS P5MT-M 6-11 The support CD automatically displays the D r i v e r s menu if Autorun is enabled in your computer. Click the item ATI Rage XL Display Driver from the... Drivers menu. 4. Follow screen instructions to manually install the ATI® RAGE XL VGA driver on a Windows® 2000 Server operating system. Restart the computer, then log on with A d m i n i s t r a t o r privileges. 2. 6.3 VGA driver...
... detects the LAN controller and displays a N e w H a r d w a r e F o u n d window. Click C a n c e l to the optical drive. Click N e x t. ASUS P5MT-M 6-11 The support CD automatically displays the D r i v e r s menu if Autorun is enabled in your computer. Click the item ATI Rage XL Display Driver from the... Drivers menu. 4. Follow screen instructions to manually install the ATI® RAGE XL VGA driver on a Windows® 2000 Server operating system. Restart the computer, then log on with A d m i n i s t r a t o r privileges. 2. 6.3 VGA driver...
User Manual
Page 146
... system installation. Verifying the VGA driver installation To verify if the ATI® RAGE XL VGA drivers are properly installed in a Windows® 2000/2003 Server operating system: 1. Click O K when finished. 6.3.3 Red Hat® Linux 9.0 The Red Hat® Linux 9.0 (2.4.x kernels) operating system automatically recognizes the ATI® RAGE XL VGA...
... system installation. Verifying the VGA driver installation To verify if the ATI® RAGE XL VGA drivers are properly installed in a Windows® 2000/2003 Server operating system: 1. Click O K when finished. 6.3.3 Red Hat® Linux 9.0 The Red Hat® Linux 9.0 (2.4.x kernels) operating system automatically recognizes the ATI® RAGE XL VGA...